Loading...
HomeMy WebLinkAboutHealth Dept Final Approval OPLICATION #:AP1243261 x +� STATE OF FLORIDA J 2— PERMIT #:56-SF-1687678 ti DEPARTMENT OF HEALTH DOCUMENT #:F11124661 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:06/08/2016 FEE PAID:400.00 RECEIPT #:56-PID-2968279 APPLICANT: Standard Pacific of Florida FP, Inc AGENT: The Milcor Group, Inc. PROPERTY ADDRESS: 3050 NW Radcliffe Way Palm City, FL 34990 LOT: 14 BLOCK: SUBDIVISION: Riverbend ID#: 4425 703 0019 000 1 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS ( ] [01] TANK SIZE [1] 1050.00 [2] 483.00 [ ] [271 SURFACE WATER 100 FT [ ] (021 TANK MATERIAL Concrete [ ] (281 DITCHES FT [ 1 [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [041 MULTI-CHAMBERED [ Y N ] [ ] (30) PUBLIC WELLS FT ( ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ l [061 LEGEND 1. 28-015-08SC3 2. 70-143-54SC4 [ ] [321 POTABLE WATER 75 FT [ ] (071 WATERTIGHT [ ] (33] BUILDING FOUNDATIONS 6 FT [ ] [08] LEVEL [ ] (34] PROPERTY LINES 5 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 849 [21 SQFT [ ] [36] DRAINFIELD COVER [ l (111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 5.00 2. [ l (38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 07/18/2017 [ ] [141 DRAINLINE SLOPE [ l [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 16.00 [ l [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS 1.00 [ l [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ l [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR Brian Davis(Brian Davis Sept [ ] [231 FILL TEXTURE [ ] (481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] (25) AREA REPLACED [ ] [491 TANK PUMPED [ ] [26] REPLACEMENT MATERIAL, [ ] [501 TANK CRUSHED S FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 05/03/2017 DISAPPROVED ] ' Environmental Specialist II Bri Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APpROVED / DISAPPROVED ] : t. Lucie CHD DATE: 07/18/2017 (Explanation of Violations on following page) Environmental Specialist II Brian gram(ENVIRONMENTAL HEALTH)DH 4016, 08/09 (Obsoletes all previous editions which may not be used) RECEIVED JUL 2� 20172 of 3 Incorporated: 64E-6.003, FAC g EH Database v 1.0.1 AP1243261 EID1687678 &PLICATION #:AP1243261 STATE OF FLORIDA PERMIT #:56-SF-1687678 ? "{ DEPARTMENT OF HEALTH DOCUMENT #:F11124661 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ,y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE pAID:06/08/2016 0 FEE PAID:400.00 RECEIPT #:56-PID-2968279 Violation Number Comment Comments The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated flow of 640 gpd. 1050gal+483gal STs in series. 540 gal (70-143-54SC4) DT. liberty 1/3hp pump. 5x15 chamber long trench DF. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system and alarm check. Final system approved. Contractor, builder, and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1243261 EID1687670