HomeMy WebLinkAboutTrussREVIE ' P
All-o c 1-71 d
PACK TO
b
4
TYPICAL 7' SETBA
CORNERSET LABEL
AND SPACING
SHINGLE
RO
fHEEL,411-3,l----
0
e
PLUM
Reviewed
IDkw Code
comPiall'"
Universal own
cJCWr�
F
NOTED
NULTI-PLY GIRDER CONNECTION.
ALL PLIES SWILL BE FASTEND TOGETHER (BELTS. NAILS. MID III? SCREWS)
PRIOR TO INSULATION AND BEFORE ANY LOADS ARE APPLIED PER THE
SUPPLIED ENIMAZERI4G SFEEM
NITM
DO NOT CDT 13R ALTER TRUSSES WITHOIT CONSENT [F THIS OFFICE BACK
CHARGES WILL NOT BE ACCEPTED WITHWT PRIOR WRITTEN APPROVAL BY MR
SERVICE DEPART)ENT'AT CARPFMER CONTRACTORS CF AWMCA. M
877-M-9487
NOTE.
ALL BEARING WALLS MUST BE ABMMTELY DESIGNED TO CARRY THE LOADS
DPOSED BY THE TRUSS OR TRUSSES, AND MUST BE IPLACE AND IN SERVICE
BEFORE THE TRUSSES ARE SET IN ORDER TO AV® REPAIRS.
Labeled End Mark
Total Truss Quantity = 69. Z—
THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT.
General Notes
1) N¢dmd lop daM pa d
2) fa bWwom to open id+ yi.
wen slhonr
3) � gaff Ir 14• MC. w1:m Was%
4) Pw T— Phi b A" BCS-B1 -w=&5m
pumwad X-koc N *Auld be plond at a
mmdm n 1poriq 15' DC mm Dn opa4 tm
the *
�7ff bvL�m �xh
Pkae Mier to BC9-Bt for aN a"llad buft
ROOF LOADING SCHEDULE
TCLL 20 PSF
BCLL = Z Sr
BCDL SO PSF
TOTAL = 37 PSF
DURATION - 1.25 %
WIND SPD/TYPE= 160
ENCLOSED
BLDG EXPOSURE = C
USAGE = RESIDENTIAL. CAT II
WIND IMPORTANCE FACTOR=1
UPLIFTS BASED ON= 9.2 PSF
DESIGN CRPI'ERIA
FBC 2017
TPI 2014
Tnus member deliFn & cemetlm pieta
the deigned l*lhU E 7-IO and matiimum
fora from both cemponems and eladdmgs
and main wind force resisting systems.
•'lbe. truss h..b—reviewed m mrty an.
additional ION psfm -ron—A baaomchord We
load.
FLOOR LOADING SCHEDUL
TCLL = PSF
TCDL - PSF
BCDL a PSF
TOTAL = PSF
ROOF DESIGNED FOR
SHINGLE
ALL REACI70NS AND UPIWPB
ARE SHOWN ON ENGUMMMUNG10
WALL KEY
08'-8"
DESCRIPTION INIT. DATE
w m Id .m ha rmM
tasl to sse rev n oNm WA mans
am own vruv nm s 4rmss
m tw rcv yr oar Irm anaas
ten oan �n, w tsw m W 7n
oa to ttr mnlvs
tra vrlowt Wmar R asnn
tsa ta,ato 1'N sans uoser wr�v
IDAO/ DESCRIPTION INrr. DATE
n to trt uvnru
Q LRAM PIN= WT ]Mal
NCARPENTER
CONTRACTORS
OF AMERICA
3900 AVENUE M N. W.
WINTER HAVEN FLORIDA 33880
PHOM (BOO) 959-8806
FAX. C863) 294-2488
BUILDER D.R. HORTON STATEIEIDE
PROJECTCRiDDfSUIE
MODEL 1672/ARLA/4LAB
CCA PROJ/MODEL/ALT
7AIS/ 320/1571D
ALT DESC
OTC 3325 TROMY CM=
LOT 77 BLOCK
DESIGNER
RFS
PAGE
1
DATE
3 17
��128
�NN333988L
lc 4 "=1'
s..
REFER M
PAO( FOR
CONNECOOFL
0
r-m
TYPICAL 7' SETBF
CORNERSET LABEI
AND SPACING
Reviewed for Code
Compliance
oj Universal Engineering
Sciences
NOTE,
MtLTI-PLY GIRDER CONNECTION.
ALL PLIES SHALL BE FASMID TOGETHER (BOLTS, NAILS, MID OR SCREWS)
PRIOR TII INSTALATH N AND BEFORE ANY LOADS ARE APPLIED. PER THE
SUPPLIED ENGINEERING SHEETS
HATE,
DO HOT CUT OR ALTER TRUSSES WITHOUT CONSENT OF THIS OFFICE BACK
CHARGES WILL NOT BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL BY OUR
SERVICE DEPARTMENT AT CARPENTER CONTRACTORS OF A)ERICA, INC
877-293-9487
NOTEa
ALL BEARING WALLS MUST BE ADEQUATELY DESIGNED TO CARRY THE LOADS
IMPOSED BY THE TRUSS OR TRUSSES, AND MUST BE I PLACE AND IN SERVICE
BEFORE THE TRUSSES ARE SET IN ORDER TO AVOID REPA02A
Labeled End Mark
Total Truss Quantity = 69.
THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT.
General Notes
1) a pwdd dvd trose®, flat baess Ord Bat
9M- hate Des top died paaGY pied t -
m gr be Totaled in Side up.
2) Al huger in be Sinpwa HllSI6 udm a0nrtiae
aced.
3) Al tnm ryodig is 24 O.0 udeaf atim im
noted
4) Pa Tnm PAW koftle BG9-BI mmunadoTm
pemmet X-bead dndd be pbmd at a
mm. spuig 15' OG a— On apu4 to
be aepmIed at a aauni a d 20' betnem mch
X-brace Wamdaat the abuctum
Phu: adar to BC9-B1 for eery aaad'nod W.*g
ddML
ROOF LOADING SCHEDULE
TCLL = 20 PSF
TCDL = 7 PSF
BCLL = • PSF
BCDL = 10 PSF
TOTAL = 37 PSF
DURATION = 1.25 %
WIND SPD/TYPF 160
ENCLOSED
BLDG EXPOSURE = C
USAGE = RESIDENTIAL CAT H
NAND IMPORTANCE FACTOR= 1
UPLIFTS BASED ON- 9.2 PSF
DESIGN CRPPERIA
FBC 2017
TPI 2014
Truss member deli�m 8: mnnmmc plates
desi� ed for ASCE 7-10 and mmamum
forces lrom both mmpoamts, and claddings
and main wind force resisting systems.
• These wsses Lave Lem reviewed to carry m
additional 109 psf nonaoncmraa bottom chord live
load
FLOOR LOADING SCHEDUL
TCLL = PSF
TCDL = PSF
BCDL = PSF
TOTAL = PSF
ROOF DESIGNED FOR
SHINGLE
ALL REACTIONS AND UPLIFTS
ARE SHOWN ON ENGINEERING
WALL KEY
0 W-B"
® 0
rLmi
DEsmi-nON NIT. DATE
tie iz a a tie erwn�
nu w tie a ory ry >s va tw vuna
s rmuvn vrrn nears tra arena
tars raaw aav vaw m r art
s tar ra r an vies am �
tea as aes
wit anam�M—e ws
wi M190 IR.V SitRa11 a/1n9�
i
s
s
�
CARPENTER
C CONTRACTORS
OF A M E R I C A
MO AVENUE 0. N. W.
WINTER HAVEN FLORIDA 33880
PHONE,
(800, 959-11806
FAXr <fd63) 294-2488
BUILDER D.R. HORTON STATEWIDE
PROJECT CREE[6IDE
MODEL 1672/ARIA/4EAB
CCA PROJ/MODEL/ALT
7A5/ 320/167ED
ALT DESC
OTC 3325 TRINITY CDR
LOT 77 BLOCK
DESIGNER
RFS
PAGE
1
DATE
3 29 17
'1333986L
1A4 "=1'
f-,
Builder:
Project:
Model/Building:
Lot Alt:
ENGINEERING PACKAGE
7A5/320 CREEKSIDE � �� � ��
[i6ED
k
Lot: __..r_.� Block: ' Unit:.w_
Address: 3325 TRINITY CIR
.........:................... ................................ ..................................................................
....
JobNumber: N333986
Revision Date: New Load #: RG01
CARPENTER CONTRACTORS OF AMERICA, INC
3900 AVENUE G. N.W.
WINTER HAVEN, FLORIDA 33880
PH (800) 959-8806 FAX (941) 294-7934
[p
Reviewed for Code
Unive(mPliance
�a� Eng
Sciencea�n��
ALPINE
March 13,20.19 AN rrwc6mpAw
Mr. Bob: Michaelis
Carpenter Contractors of Amdricia,lnid.
-3900 Avenue G, Northwest
-
Wiht6t HEfveh,FL 33880-620.1
Re: Alternative: 1h s'taillationa for a single ply carried truss with a width less than the hanger width_gnd.
wood, blocking to: achieve full design load value for face -mounted: hanger _attachment * O*ft a* one: ply
supporting girder (Reference Mail WA3M2).-.
Dear Bob,:
:Fot.a single ply carried truss ''with- 'a width leiss than the hanger width you ca,nJhstqjl.:a. prefabricated jack
sob truss: for wood.filler b.1.6ckihgi The chord: sizes;:-chordgrades, and AlPirb:-,cbhhect6r.pIat6(S) to -
be the. sairrieas the single ply--carned truss. The Prefabricated jack d;!b* truss. (*):Will have a. minimum
pit6h-:of-V1Z, The single ply carried Jength of 48�'and WRI.have a minimum I.russ shall have.a. reaction of
3,.500'# or - leS�s'.'At'tadh'prefab6ctit-c�d.j'ack:�scab truss. with:. two (2)'roWs�.'of'0.1'28"x3,O"'Gun Nails at*2'
O-C, Pee row, staggered 1 ":(See FigU06 I bel6W). P16ase'tefer to the' Simpson Strong. -Tie Catalog C'-'C''
2Q1..:.9, page 2I� 'P* Pigpre:�3� for more Information,
-
Figilre 'I
For-asingle'-pl'y— Me'rAhat requires wood blocking to,odhiom-Aill design load Value for face -mounted
9
hangers attach onewood-block to the back face of the single: ply girder with the same size.and
dradeasAhe bottom.- Chord. Of the. single ply girder. The.-Wodd: block length to be such thatthe wood
blocking --extends to eachadjacentpanel points and bottom -chord intersections): h. wood
block (*)-- with two: -'.(2)-rows -of 0*.128'.x3.i7'Gun Nails at'0`0,0.. per .raw,.staggered, 3.0" applied to. the
67660orum Drive Suite. 305, Orlando, IFL 312821 - (000)'521-9106 - *(868).,422786*85
mwmalpineft.com
Pr
ALPINE
AaN rtvK
single ply -girder face, with an additional (20) 0,128, O'Gun Nails jA:each panel ppfint'app d
out X� .He to 'the,
Wood. No& face ($60 ibelow). Wi�r to the �Simpson .Wohg-T.ie:Catalog C-C..'201 9j
-page 216,. Fig.Ure. 1 for more irifortnati6n.
Figure Z,
.. ..... ... . . ......... .. .. ... ......... .. .... .. ... .... .... .......... .. . . ........ ...
The -application of preafabrimated Jack scab truss for Wood fille'rblocking :or wood blocking to, achieve full.
design load value for face -mounted h4ngprp Must be :approved by thehardware manufacil
Ail edge -and end distances, andtpai6ing for'all nail connections must be sufficient to'OreV66t.tplittihg of
'Wood..
If I can.be of any further assistance, -or if you have anyquestions. please7give me a call.. .
41.
-Aer U" .XfZ
. % Am-:': : �� .
'STATE (IF
Chief Engineer
Alpine-ari. M. Gor6poiny
Engineering Popartment.
Orlando; FL
[VIV
6750 Forum DdV&. SUJ iteC306',:O'r1afid6.. FL.3282.1 - (800).521-.9790 - (863) 422-8685
Pm
iY
ALPINE
M1!WCOW_1MY
April 26,,:2019,
Mr. Bob Michaelis
Carpenter CoMmictors of Atnerida, Inc.
39.0.0 Ave.nueQ, Northwest
Winter Haven, FL 33880-6201
Dear. Bob,.
R6'- Stro'n'Oback bridging: on fbbftrutset.
I understand Aheeaissofti6 condom over our feborbtnendati6nsf6r:strob back-bridgin'' on roof
9 g trusses:
.8iiongback bridging for roof trusses is n.ot.a...r.e.q.uire.m,ent'..of:A.NSI=TPI 2014 nor is it U a requiremenfothe
Building Component -Safety, Information- (BCSI), But strongback bridging
on roof :trusses is
recommended, by Carpenter Cdhtradtdrs of. America: -Str6higback bridging serves the:. following two _
functions:.
One, bridging aligns the bottom chords after they are- set :so.. they are u.niform along the ceiling
fine I and h Os- rvi.ea i i y
inG k' .. w—i ceiling so , c 16,iit�
Twoibrid.gingredu.ces-e6liativdd&fle.cti'on.6fadiabeht-tr'Ussds::
Strongback b(idgingAo6s: hot;pr6Vent or reduce overall indiVidual deflection, especially any rootrUss6f § * ' s.
deftqq
.. .. ....... ........ .. (i n g. nj qrqthan 1/4 inch,
.......... .. ..
StrongbaqX- bridging in roof trusses does not servei'.as :temporary be permanent bracing �and is not
or .share design loads, -between i(Usses. Consequently, , -rip dos . 1 . do load' have`intended to .distribute.
dh§tn' UiO y s
been accounted for -With this. detail and continuous. s'tr6hgbac k.bddgiho should . . * hotbb -att' ached between
common and girder '.trusses-.. The. use :of strongback bridging shall not. interfere with other, d
gi. psga .
considerations as specified :by (116 Engkieer' f R c or Building,Desig r.
.6 Ord C). 6 1 Me
The bUter-ofids of 'Siroogbackbridging shall be aftochedjo a wall or anothersecure end. restraint; or
a.s.specified:by the Engineer of Record 6r.thd Building.D6sidri6r.
Strofigback bridging 'shall be -'a. minimum of 2j.(6 ftordinai LUmbor- oriented With the d' epth vortical.. Attach
with (3) fd pqMrpon nails (P. 126Tx1T) nailsat: each intersecting 'member: When extending the
strdn k bacbridging overlap by at a.mini mur n of . two trusses. The jocat im Q f
9the.. tr n . ack bridging
.9
maybe: specified .Oy'the -Truss Manufacturer-,. Engirie&r of Record, or Building Designer. Please rofd�.-;to-
kSj "St-rongback! P :MBR-18ki.014 deta�iil for more information. The graphidl
.ng tpvisions' O.r.to Alpine:
urpose shoWh (FigUrie-1) is fb*rg.eno-rid.illustrAt,ivO!'p- only.
Fbrum Drive:S . ulte 305, Orl6ndo, FL 3282 T- (800) 521-9790i - (863)422"8685
WWW.WoineitW.com.'
ALPINEA.Mur-.-
I X v U L- t.1*1 JL L- `,Iv . I .:. -) )
Fi gure.l.,
If I..c;ain be of any further assistance or -if you have any questions; please give. me a call.
William. H. Knck. O.'E*
ChiefEngiOper
Alpirlo an 11W Company
mpany
Engineerihg'136p5ttmeht
-()tl6n,do: FL V82.1.
676.0. - Forum Drive Suite.365, Od6n'd6, FL 32821 -; (800). 521-9.790 - (8153).4224685'
W",alp'in.eJtwxorn**
MO
AN ffWMMPAW
13723 ft"*rt Oche
SU110 MO
Marylaw HOfOhf&,Mo 83043
S.TRONGBACK BRIDGING RECOMMENDATIONS
IN,- All scab -.on blocks shall. be: .-m. -minimum,
BUTT STRONGBACK
BRIDG . ING TOGET14ER 'stress graded lumber*.',
M-.-AU..strongback bridging .and bracing shall be:
m1n1hum 8x'6 '.Stress' graded. 1.uHbL-4,.1
Oi-The .04rppse� of sirondbaqk- brid6lhols -t 0
op load sharing e
10'! ATTACH SCAB WITH 10d;BDVGUN.. Individual i S,:
devel 0 between I vidua truss
ROWS' AT 'resf&Wnri In 'an overall Increase I +k
NOTE, IN LIEU IF SPLICING AS"SHOWN,
LAP'1TR13NGBACK-'9RIDWNG HERDERS
Fak:AT LEAST 1314E TRU=:;SP4C1NG
STR13NGBACK BRIDGING SPLICE DETAIL
GING ATTACHMENT A"L T*-.E**RN*A
�A IF
stifPneisr.pf, the. floor. -systemi 2x6*
stronoback brldglng�, PoMt1oh0d- As. -:!�,hoWh in
ditalls, Is recommended at. 101 =C".O.C. (Max;)
iw--Th!�- terms: 'bridging' :OnC(:"bt�-Qdh"`
mls,�akenly . �u are. sometimes
sed"Interchangeably. `Tnaclhg.�� Is. an
Impgrturit ;structural r�equlretnen-t. of any rLo&-
or roof system, Refe)-' the. Truss.'De8igh
-D "L 'uW,'Om nts -for
..r.q;*Ing (TD.M. fbi.,,� -the. ..bracing r .q e
each IndIVIdIUM truss co.m ent, 'Bridging;'
porticutarly, "strongback'Tornidging' 1:s. q:.. g'4'
recommiehdatJoh for a -truss system to help
con -trot vlbratlon. In: addition;. to aiding.. In the:
d1str1b tion of point toads )pi�tw.e&6 adjacent
M
-stro -to reduce
truss, nqba,�k� �rl�qlnq serves%
bounce. Or at lon 'rOsJultlng, from
t moving point tqqdtj:.sUch as footsteps.
The Performance of all floor systems -are
enhanced . by. the. Insto'Lliatloh strong6ai�k
bridging and -therdfori�Ai�. s.t.r6ngty recommended
nded
by Alpine,
For additional information rebardleig strongbo
bridging, refei.- -t"* -'BiOS*j'(B Itolin'
P u g Component
Safity, Information).
Mmj i
No. 70861.
STATE. F
> 12 Ofl
PL:
PSI"' I
DL'
zPSF I
D L
PV
L A
PSF
FAC,,
. --I
1.00
S
IF �SHOSINtl
�t���r�.��'��: 41AL w�r�t�Ir�S MORE
1 S.'R E 0 V.45.0
..Qt `4C. t * . TEq • �,,: kk, i ':Q 1 `.' TC': ID E? `1 = LR t 0 i Ci 1 i1 lV. MA'T�€ AL._
AT* i ,ASS' 2-TRUSS .S•.•
SZE -AJPPMQPRTA.TR,': �4:i T� tal ipl '3 � ` 7;�:.i� 9� 1� .A. PLAT158 AND.:
WHEA: DATA j x :.: HtlfCt :: A: i IiS�: t 3 L Elggt:
�•t��a ;;��3siitt ta�w'�� � �si�I ���?1 rta,�,e�.: `�j..' • ���t�' ` � �TQ•. q� 5�t��L�Ep'
u'':rXis#�0K"°Ti:i�'�6!'7c' i'k FiE1t'0�1..
,... err ��;►3.C. ������ �Q•�rir�f f':k'�lnye'��' -. .. .. ..
o :r bri�k� .apt1
•.''. _
• �-.a-+.n-.k-.ri."°'.'...."', ..:,g ., ....rr..y....m..rn.i�,..::. i+i� �..,:.�,r::oa.u.�^.r-' �;•••_--:.:n-�;- '•d�,:w-.a at:r++::=„—•—. ;:.:LL' �`-t %=:'^� .ti'*M:_'�."":. ' ,
;
n fii�•.
... . • ;;L7 : _ �+, � -- ��'�: dui, y .
vu 7 �u aaaaloraayoqA po( IGv.S-4snpU�ags•aan .Y]¢S (e.�a•}w{d;•.aa qdl fwrril Ir'M. SiNId,Y StOCOOW'AiID4Ps3
XyW r��,{Y,G DNIJ1YdS 154415 qaM ata4i pV9 a0od saiau (wauaC iAaf 714 aas ugiouJo/YI uoL dOJ enpo 1u0111181 eacet
Naas I Idl/ISNY Jad JaANM %WM ayi JO AUMuodwa >t ..mian.�s Al JOJ
Ogrv�p q.(} Jo asn Puv 1411R*4p- pll w-w ugiap V1, .wi A aMr�t I V.,.
Puq+,ralord Ja rauo;draav s pnM -04.wp xjIi . 04am a0od AoAo� x 6*9.w w.lv8 1-lowy
'a4dd( a puny J (Shc/1SNY �H 4 +: ey} plTq a} Ia voo diApv�7 �M; Pa Ni 1,N16dWm NW nv
yyss t� Ja Jo a eauvu.ro uaa ssn o a�n o Aur -0 v� r
ua�J ual}vinap .cuv raj alglsuodcsJ aq ;o nays •auI o+p s;uauadud3 Wpyn[ ALI /a uo1gHP v '4MdIY
%uvl;lsod a;old prvpuo;s aa1 i-Voll a0ulAVOP o; u+Jae �J 1'
.aspu wit !sa1uel fnoiaa ;u(ar ay} uo puv 0Aag9 UA045 ■o ugHsotl PUG ssn+} Jo �---�' j aavd ipve a; sa}vld jmy 'elgvai do sv -0I[ .a a( -Ct st�{;7of i Jad pollvpl Ou(avuq #A04 11r4e � Jam' •••���� �IIJJJ
sgaA Jo }I.NaJ;reJ Ivan}vl }wuouJd Jai ways OV01%wo•l •QM%aa 14 P4Pv ;v Aluadoad v anvy nays
KOIQ�IHJd3d eM21Q p 104� uai}oq ppuv oul vat's Io ae}an4;s peyao;}v JhaedoJd anvy 11vys ppaoya aot'sgaual(;o Pe;ou swppyyl�
IS'JC Jad OgovJq ua.+adW.4 rplAead Ilo4r s.lenv;sul •suo1punJ ada4i Oupjah led o} Jgad saq;avJd
WIVOT 3111Q J i �•aaa D o puc :IdLe q'";} w4,0 Aj.A0s ou.Jed%.aa WAPlmo ISoc Ja Welipa i•ai® wi ■alla
alll is I �dRs '04"4 roupoalAW W a•na auaagKs cptfs i sassnaL
NIVd3N N3gW3W 3M saa„v1sM< l Na�IAYYk(4anSIWJi o°LMMO UIUNN TW AAa,roJ 4HY ILL aaYM NICHMAa"ilNwaadNr,1�
•awn NM, 1lo:-a [ 6up-odS WON
pa Ja v3.g Moa a I-Jl' - .IagwaW 9xZ
pa.Ja66o:�S moa alc(noQ - .AagwaW yxe aon }uo J3 = 0
ISIInN <u1w 'aE x rSUVO) xog POT aoo3 ){ovg =
,Ja66v�.s
f—
e aauow tt, + 0 + O + O + 0
� un 4H
O + O -I- O + 0 +
� lvold�tll--
s
tf
aau0�slq �
w+LRuIN s
#0999
#9609
#0829
#9919
9xZ
p.Joqe .Jo qaM
#Skt,V
#OLOV
##OVSE
#09*C
l,xZ
p,104e ,Jo qaM.
#92L9
#Sz2S
#009-�
#36E,
r2b
gxZ
p.JoHo ,Jo qaM
#SE8E
#SOSE
#Sb0£
#SL62
i?x2
pu093 -+o qaM
#9�L�
#962*
#9E9£
#9£96
r9E
9x2
pdo�3 4o gaA
#0126
#0£6z
#0£S2
#OL•b2
bx2
p-icq:) .Jo qaM
#SLS£
#92TE
#S9E2
#0£22
.0E
9xz
p.Jogo ,Jo qaM
#SSS2
#91E2
#096T
#OT6T
vxz
p Jo�e ,Jo qaM
#0292
#Str2Z
#58ST
#59, T
rbZ
9x2
p,Joge ,Jo qaM
#SVLT
#96K
#9901
#9L6
vxa
p,JoWO .ao qaM
#STbT
#9621
#SSOT
#SL6
r8T
#xz
Aluq qaM
4068
#0£L
#SE9
#029
.ZT
Fxa
/clue qaM
dl�s
-1-.AQ
JH
e-3dS
_1
a=IS
.JagwaW
a�JDA 1D1xH .4agwaw wnwlxvW
pooh jo uop�.Io.m([ .4o,4 pasua.Joul aq AUw sao.4o,4 .4aclwaW
%0 = uol:.o.JnQ p�oo-1
11 r@C[ ,Ailoda�j uacjwaN
'spool ul-a14. Aulo a.uoddns a.ou Avw p jogo u"o.ag
-oa,lo &p1d .lo}mauuo:) aye ul4}IM Bul a.an»o suol;mas
qaM .ao p.aog= paGVWVp ,aoj. pasn aq }ou AMA 11oa.ap Alioda.A sl41
'samllds laund-plw
;.n a}nld .aol.oauucD uano.aq ,ao j pasn aq Avw liv:pp ilodeA sIyl
',•OS9l apro J(3 NSW puv. Ilk ap-CIA 1011SIA oI- pa!H611) 51 11'0"P
s144 4;•IM asn • .ao.4 ap-a.46 gagwnl pa;4.1w.lad wnwlxow a4l
'.4agwaw apls gvoa o}ul (ulw ',ex,BZi'0) sllvu un8 .ao xoq 10% Oulsn VIDN
'paaaoft s sMo..l f'o'o At }o sMoi <B) aa.aNa. Oulsn s aagwaw gxZ o}ul INN
paua8 o}s sao a ''vo ,y vro slAo a (a) oraq 6uisn s Jagwaw qXB o� ul WON
'lauvd ua)-{o.aq aNq- uIW41M aq "nu (S) Lq 6ual Aagwaw gvaS .
(H) + ('1>�a) = (s)q::eual .lagwaw apls wnwlupq
ago f aad qv�s auo iddy aagwaw pa6owop so 5alma s
pun lapo a6 lazls awns 's.aagwaw apls gxZ CM} .Jo yxZ osl = (S)
(a) roa av pa6owop jo apls 4Dva uo anuo*sip Bulllvu wnwlutw = (-1)
uol}oas pa6owop 4o Lfoual wow ,21 *a.lo paBrowvQ . (g)
ou o v s,a oda,A A o ,Jo .aa.Jn ov nulow ssnAq. 4. ay;1M ovlduoo
p panto jo aJo ssn.aq� lad slvajq ant} uroy} a4aowouqpuvv
lauvd p.aotp uad >1o"q auo uvq!! a.Jow oN sjac(waw ua:io,iq gxZ
.ao trxz 4}iM sassn,I} Ald al66uls do,. Aluo p11vA sl ul3lzap s141
'.aagwaw qaM .lo
puo4:) uasjo Jq ya.1m ssn q. 'o uo} s aloda.A sal3loads 8uIA-o jp s141
ua>jojg Jo pa>1D)ojo
I
I
0
sc
a
Lumber Size and.Grade-Minumum Recjulrpmi �nfs
i1qaid— (mQ,!MS#Ot".P1dq,4i
raft 4.,br i - . -;SpF *X-oi�-wyr 6eqar
Purlrns .1Uqlml
'A P , ply I fl:; c-gb-f'4d n c e,*i;, - 6 u ri" t N 0 S' rg I r R', 11 "kniS.
-Maximum MomInif height; 31O.-foet 061=6ri r"-!ialjs unJoAi d6ted Ls
:h& rnphj.EnJwd, Cat H,
u
m
TRUSS UER VALLEY -FRAMING
V.�CLEf•Y1413RAMR-.OR R(DGE
F. V L) At- PS I v I Di Mack.
lmrk('nV.��td' 6EN ai�c iliatcrip,p,te locations are
lomd,bow"n mw-. ,
K*6q.u,1.r.qm- q f- Notes
4 10d*tdi4i9lU-
.5 -1 6d to L-03 I f S
Rafter t6.tWo.7.X6 sleepers.'
415dtoe4alri
-swepa tti udli-
4*16d td&ftlli
3200 td&iMUS,e2,ch $1a4qar.-A0ru$s
A449e:bobrdia roof bldck
4 164 toe-ntills
--Fluffid to CTM,
:Trfmcm*-616ikitwi
416i6to&W4
-rrws-tdiolopli.
416d--toe4rbyis
Trjlw'to d1j3.pl F-
4.16;1.toe-.hdft
•Crl b In.
e-n
t 334dt
4 16d'toe-nalls.
-�ii mo; -0861 -T(�'U
AVDM 41: '-3 0 46 54 FM r
44 -0 ZO 7 -r DAT9 10/91JA
un 0ti t--U-vfi t -TC DL I
y.
qc ffL 0 .0 0 0 DRW-O, W4NVI
,�U 4;X W flc(14a —fh f TAIt Be- LL 0 .0 0 0
Irt;2 = !:� * .. - - - .4
Owl! r - ,
,w M.
00'� AM '.. I ,,! . . . , , . V% *= = lud� , I , * A I� P.- , *-
de ' 1 114 'T6T. LD-30 50 47 61
AH TW or Por, OR VP
for rov= =f
. 4 .
F�. rw.w.Wr."a4 -sq* iNx. Job's "b% -KROVE
Face -Mount Hangers - I -Joists, Glulam and SCL
� n 5 6 4 •�
t
These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart.
0
0
Carried
Dimensions
Fasteners
Allowable loads
Member
{m }
{m)
Actual
i .�
DF/SP " ,
SPF/HF ";
Joist
Model
mina
Code
Size
a N0.
e 1
Web
Max.
Species Header
,
Species Header
Ref.-
(in.)
o Stiff
""W
H
B
-
Face
"Joist
co
- Regd.
Uplift,
Floor
Snow
Roof
=Floor
,Snow
Roof
(125){100)"-
(115}
(125)",
Min.
(14) 0.148 x 3
-
1-0
1,660
1,805
1,805
1,425
1,555
1,555
IUS2.56/16
• -
2%
16
2
Max.
(16) 0.148 x 3
-
70
1,805
1,805
1,8C15
' 555
1,555
1,555
21/2 x 16
MIU2.56/16
-
29/6
157ii6
21/2
-
(24) 0.162 x 31/2
(2) 0.148 x 11/2
230
3,455
3,920
4,045
2,970
3,370
3,480
U314
I ✓
29/16
101/2
2
-
(16) 0.162 x 31h"
(6) 0.148 x 11/z"
970
1,945
2,205
2,375
1,675
1,895
12,045
HU316 / HUC316
✓
29/i6
14%
21h
-
(20) 0.162 x 31/2
(8) 0.148 x 11/2
1,515
2,975
3,360
3,610
2,565
2,895
3,110
IBC,
' MIU2 56I18 "
• -
2sti6
� i� l»
2'/z
:-
(26)' 0162 x 31/?-
(2) 0148 x 3'lz
230
3,745
4,045.
4 045.
3 220
3,980
8,480
L,
LA
21h x 18
HU316'/,HUC316
14'/a
21/
F-
(20) 0.162 x 31/2
(8)0148 x 1'&I
z 1515 "
2,975
3 360
-3,610 i2
565i2,895
3,110
21h x 20
MIU2.56/20
197A6
(28) 0.162 x 31/2
(2) 0.148 x 11h
230
4,030
4,060
4,060
13,465
3,495
3,49521/s
x 22MIU2
to.26
56/20 ':
4-/2
197/afi
T'h-
(28) 0162 x 31/i
(2);0:1"48 x 11/2 .
230
4,030
4 060:
4 060
3465
3,495
3,495
29/16 x 81/4
to 26
29/1s" wide joists use the same hangers as 21/2" wide joists and have the same bads.
3
MIU312/`#
=
31A
9"A6'
21/2
-
'(16) 0.162 x 31h�
(2) i3 48 x��11/2
.230
2,305.
2,615
2 820 1980
2,245.
`2,925i
x.g1h
HU210 2lHU0210 2
✓
31h-(.
8' 46 ;,:
,21/z
Max,
�(18),0.162 x 3'h;
(TO) 0.148 x,3
7,.5
2,680
3,020`�
3 250- 2 305
2,605,)
2,800'
IBC,
MIU3.12/11
-
31/8
111/8
21h
-
(20) 0.162 x 31/2
(2) 0.148 x 11/2
230
2,880
3,135
3,135 2,475
i 2,695
2,695
FL,
3 x 117h
HU212-2 / HUC212-2
✓
31/s
1O'A6
21h
Max.
(22) 0.162 x 31/2
(10) 0.146 x 3
1,795
3,275
3,695
3,970 2,820
13,180
3,425
LA
HU3.25/12 /HUC=3.25/12
31K
113/4_
21h
`'-
'(24)"0.162 x 3
(t2) O'.148 z 3
17 5.
3,570
1AI63O
,4,335 :3 075
3,470
3,735i
HU3.25116 /,"
•
Min.
(20)� 0.162 x 3W
(8j 0148 x 3
1 515
2,975
3,3604
3,610 2;560"
2,890
3,105
HUG3.25%1fi
3Y4
131i4
21h
.
Max.
1
-(26) 0162 x 3 h
(12) 0.148 x 3
.,7r
3,870
4,365
4,695 3;330.
3,755
4,040•
_
'3'1/6 glulam
HUCQ210,= -'SDS
3)/a
, - 9, ., '
:3
-
(12)1/4" x 21/2" SDS
(6)!WI x 2W' SDS
2 i.b
4,'.3IS
4,315
1„315 3 600
3,714
13,710
FL
HGUS325710"
-
3?la
5hm ,
"4
-
-'(46)'0,162x31h
" f16)0362x'3?I2'
4,095
9,10oe
9;100:
9100_(7825
7,825
7,825:
IBC,
HGU83.25/12 .
•"
31/a
--105I8; -
4 „
='1
'(560.162 x 314'=
(20) 0; 62x31/2',
5 04Q
9,400'
9,4,00
9 4,, `9,`085
( 8,085
8,085,
FL
,LGU3.25-SDS '
-
31/4
$:to 30 `
41h
'-
(16)1/4 x 21h" SDS
("12),1d' X,2,1/z',SDS',
5,555,
6,720
7 31u
7 iitf;(,4 840
.5,285
0;2z:5
HHUS46
-
35/a
5%
3
-
(14) 0.162 x 31h
(6) 0.162 x 31/2
1,320
2,785
3,155
13,405 2,395
2,715
2,930
31/2 x 5'/a
HGUS46
-
3%
47/16
4
-
(20) 0.162 x 31h
(8) 0.162 x 31/z
2,155
4,360
4,885
5,23013,750
4,200
4,500
HUS48
•'
` -
39A6
6Y%
2
"-
(6) 0.162 x 31h''.
(6p0762 x.31h ;'
1 320
11595
11815'I
1;960 "1365
1;555
1,680
31h x 7114
HHUS48 "
-
35/6
1 71h'3
'-
(22) 0.162 x 31/2-
(8) 0.162 x 3'/z
%:,80
4,210
4,774
5,140� 3 615;,
4,095
4,415.
HGUS48 '
-
3%
7'/,6
T 4
-
, (36).0.162 x 31h
„{12) 0162 x 31h ;
3,235
7,460
7,460)
7,460,1�6 415;
6,41516,415.
IUS3.56/9.5
-
35/a
9'/2
2
-
(10) 0.148 x 3
-
70
1,185
1,345
11,455 j 1,020
1 1,160
1,250
MIU3.56/9
-
39/16
813As
21/2
-
(16) 0.162 x 31/2
(2) 0.148 x 11/2
210
2,305
2,615
12,82011,980
2,245
2,425
U410
• •
✓
39/,6
83/a
2
-
(14) 0.162 x 31/2
(6) 0.148 x 3
970
2,015
2,285
2,465 1,735
1,965
2,120
HUS410
• •
-
39ti6
815iifi
2
-
(8) 0.162 x 31/2
(8) 0.162 x 31/2
2,990
2,125
2,420
2,615 1,820
2,070
2,240
HHUS410
• •
-
3%
9
3
-
(30) 0.162 x 31/2
(10) 0.162 x 31/23,565
5,635
6,380
(5,445 4,845
5,486
5,545
31/2 x 9'/z
HU410/HUC410
• •
✓
39/16
85/6
21h
-
(36) 0.162 x 31h
(12) 0.162 x 31/2
3,235
7,460
7,460
7,460 6,415
6,415
6,415
H000410-SDS
• •
-
39N
9
3
-
(12)1/4" x 21/2" SDS
(6)1/4" x 21/z" SDS
2,265
4,500
4:500
4:500 3,240
3,240
3,240
HGUS410
• •
-
3%
9'/,6
4
-
(46) 0.162 x 31/2
(16) 0.162 x 31/2
4,095
9,100
9,100
9,1 DO 7,825
7,825
7,825
IBC,
LGU3.63-SDS
• •
-
35/a
8 to 30
41/2
-
(16)1/4" x 21/2" SDS
(12)1/4" x 21/2" SDS
5,555
6,720
6,720
6,720 4,840
4,840
4,840
LA
MGU3.63-SDS
• •
-
35/6
91/4 to 30
41h
-
(24)1/4" x 21/2" SDS
(16)114" x 21/2" SDS
7,260
9,450
9,450
19,450 6,805
6,805
6,805
IUS3.56/11,88
• -
35/.1
111a,
2
-"
(17)0.148x3:i
=- ..,�,,
?o
1,420
1,615°
1,745 1;'220
1,390
1,485':.
MIU3.56/11
U
- .
,3 .P
11'/s-
21h
-
.
(20) 0.162 x 31h
(2) 0.148 x -j'✓z ("
210
2 880
3,135
3,133 2 47512;fi95
2,695=
U414'
• •
•, ✓
3gh6
1 10
2
-
(16) 01R9 Y:I1h'.
' im n dR Y,A i
.1n?n
19 ins
9Rim,':
->,Agn1 i'9Rn.)
7'94,;
l9 vs
HHUS410
•.
-
35A
9
3
=
(30) 0
HUS412'
.:.
-
39%i6�
„lb1h; a
; 2'
=;
(10) 0
31/2 x 117h -
''HU412! HUC412
39ti6
.; .
10/16�
21h.
Min.(16)
0
Max..
(22) 0
'HUCQ412=SDS
- f
39ti6
11
-,
(14)1/4"
HGUS412=
-
AS,
in6
4_,
=
(56)0
LGU3.63-SDS
- 13$/6
8 to 3q.:
41/2
'=
(16)1/4'
MGU3,63-SDS
•
-
1-35h1,91/4to30
A
-_
(24).1/4"
HGU3.63'SDS
•'
-
3%
11 to30,
�i1h
--
(36)'/4"
46 See footnotes on p.150.
THA/THAC
3
. �i
Adjustable Truss Hangers
O)
E
This product is preferable to similar connectors because
of (a) easier installation, (b) higher loads, (c) lower installed
cost, or a combination of these features.
The THA series have extra long straps that can be field -formed to
give height adjustability and top -flange hanger convenience. THA
hangers can be installed as top -flange or face -mount hangers.
THA4x and THA2x-2 models feature a dense nail pattern in the
straps, which provides more installation options and allows for
easy top -flange installation.
Material: See table
Finish: Galvanized. Some products available in ZMAX® coating.
See Corrosion Information, pp.13-15.
Installation:
• Use all specified fasteners; see General Notes.
The following installation methods may be used:
• Top -Flange Installation — The straps must be field formed
over the header — see table for minimum top -flange requirements.
Install top and face nails according to the table. Top nails shall
not be within t/4" from the edge of the top -flange members. For
the THA29, nails used for joist attachment must be driven at an
angle so that they penetrate through the corner of the joist and
into the header. For all other top -flange installations, straighten
the double -shear nailing tabs and install the nails straight into
the joist.
• Face -Mount (Min.) Installation — Install face nails according
to the table, with at least half of the required fasteners in the top
half of the header. Not all nail holes in the straps will be filled.
Nails must have a minimum 1/2" edge distance. Straighten the
double -shear nailing tabs and install the joist nails straight into
the joist. The face -mount (min.) installation option accommodates
conditions where the supported member hangs either partially or
entirely below the header.
• Face -Mount (Max.) Installation — Install face nails according to
the table. Not all nail holes in the straps will be filled except for the
following models: THA29, THA213, THA218 and THA413. For all
other models with more nail holes than required, the straps may be
installed straight or wrapped over the header, with the tabulated
quantity of face nails installed into the face and top of the header.
The lowest four face holes must be filled. Nails used for the joist
attachment must be driven at an angle so that they penetrate
through the corner of the joist into the header.
• Uplift — Lowest face nails must be filled to achieve uplift loads.
Options:
• THA hangers available with the header flanges turned in for
3%" (except THA413) and larger, with no load reduction —
order THAC hanger.
Codes: See p.12 for Code Reference Key Chart
1314' for
THAG422
for
422-2
426.2
THAC422
Face nails Top nails
per table per table
13/i typical
2h' for THA422-2
and THA426-2
THA418
H2Yay
C H
v
W 214,
THA29
Double 4x2— 2face nails
Use full table value (total)
Single 4x2 111. 4 top nails
See (total)
nailertable
y'' Straighten the double
shear nailing tabs and install
nails straight into the joist
Typical THA Top Flange
Installation on a Nailer
(except THA29)
THA422 Face -Mount
(Max.) Installation
Straps maybe installed straight
or wrapped over with tabulated
face nails installed into top
and face of head(
® Double -Shear
Double- Nailing Dome Double -Shear
Shear Side View;
Nailing Side View
Nailing Do not (Available on
Top View bend tab some models)
'' Straighten the
double shear nailing tabs
and install nails straight
Typical THA422
Top Flange Installation
on a 4x2 Floor Truss
THA44 Face -Mount
(Min.) Installation
ryNrcar r nnca
Top Flange Installation
er to
tnote 5
p.187
86
THA/THAC
........... ............... _.__..................... ......................................... ....................................................................... _....... _....... ................................................................................. .................................. _...........
.
Adjustable Truss Hangers (cont.)
s These products are available with additional corrosion protection. For more information, see p.15.
0
1-fl,
Dimensions Fasteners
Min. Min
-Model7in.) top, , Header _f n�
No Ga. Flange .depth Carrying Member;
H] C (in.) (in.), f d
.d.
1'/z
-
1 (2) 0.148 x 3
(6) 0.148 x 3
(4) 0.148 x 3
525
1,750
1,750
1,750
450
1 1,33011,330
1,330
THA29
18
15/a
911/16
5Ye
27/s
-
(4) 0.148 x 3
(6) 0.148 x 3
(4) 0.148 x 3
525
2:610
2,610
2,610
450
1,985
1,985
1,985
THA213 -
" (;8
7 s/a
13%
5'Jz °
2 -
-
„(4) 0'. ""'
(2) 0.14`8 i,i
{4) 0.148 x P/2
1.'
i 4� ,
" 1,46tt1
1,1'iU
t' 1L'
1 Y 1t3° z'
THA218
18
15/a
173Aa
5 /2
2
-
(4) 0.148 x 3
(2) 0.148 x 3
(4) 0.148 x 11/z
-
1,460
1:460
1,460
-
11110
1,110
1,110
IBC,
THA218 2'
J6,
3%
171Ms
8
2
-
(4) 0162.X'31%i
.__
(2) 0.162 x 31/z
' (6)'0;148 X 3
-
1 r60
:.
1;_ x
: t oU, 4
E,d9U
1,:'i15
1,515
FL,
THA222-2
1 16
31A
223/1s
8
2
-
I(4) 0.162 x 31/z
(2) 0.162 x 31/z
(6) 0.148 x 3
1,960
1;995
1,995
,490
1,515
1,515
LA
THA418
16
3%
17'/z
77/a
2
1 -
(4) 0.162 x 3'/z
(2) 0.162 x 3'/z
(6) 0.148 x 3
1 *60
11,9J5
1,0-95
1-
1:490
1,' 15 1
1,515
THA422,
16
35/a
22
77/a
2
-
(4)`0162 0'/z
,=(2} 0.162 x;3'/z`
(6) p148 x 3-
1..v1 �3
1 a5
1,J5
?9(i
THA426
14
3%
26
77/a
2
-
(4) 0.162 x 3'h
(4) 0.162 x 3Yz
(6) 0.162 x 3Yz
-
2,435
2,435
2,435
-
2,095
2,095
2,095
THA422 2s114
" 14 ,
71/4
2211/s
93/4 .
2
„=.,
(4) 0362 x 3'h
(4) 0.162 X 31h-
(6) 0.162 x 31/2
3,330
3,330
' 3,330
2 865:
2;865
2,8W.
FL
THA426-2
71/4
261/s
93/4
2
-
(4) 0.162 x 31/z
(4) 0.162 x 31/z
(6) 0.162 x 3'h
-
3,330
3,330
3,330
-
2,865
2,865
2,865
THA29 118 1 1 % 19"/6 1 51/a 1 - 1 9'ti6 I - 1 (16) 0.148 x 3 1 (4) 0.148 x 3 1 525 12,26512, 2651 2,265 1 450 11950 1 1950 1 1950
THA218
18
1 %
173/s
51/2
-
173i6
-
(18) 0.148 x 3
1 (4) 0.148 x 3
855
2,450
2,450
2,450
735
1 2105
12105
2105
THA218 2
1"6
a
17'1is
8 .'.
, -
-141fis
(22} 0,162'X 3"/z
(6)`'0:1;62 x 3'1z
1,855
3,v10'
^a:3'k0
` aii •;
1 595
2;°
8�5
:,8 - ;'
IBC,
B
THA222-2
16
31/a
223/1s
8
-
141As
-
(22) 0.162 x 31/z
(6) 0.162 x 31h
1,855
3,310
3,310
3,310
1,595
2:845
2,845
2,845
LA
TtiA413
18
351a
334s
41/a
-
133/a
(14)'0.148•x 3 .
` (4)-0148 x 3
3 v s
r,dj 5
2,340
G 4 0jb3
735
=.1 0
2.0"-8
2,105
THA418
16
35/a
171/z
77/a
-
14'/s
-
(22) 0.162 x 31/z
(6) 0.162 x 31/2
1,855
3,310
3,310
3,310
1595
2:845
2,8451
2,845
THA422 -
16
35/a
' 22 ',
77/a
-
141fis
22 0.162 x 3'h
6 Q.162 x 31h
1,855
3,?10
3,310,
3,310 -,
€510
?_?1`5
1,1 `5
845
THA426
14
35/a
26
77/a
-
161%
-
(30) 0.162 x 31/z
(6) 0.162 x 31/z
1,855
4,415
4,480
4,480
1,595
3,795
3,855
3,855
s
2 THA422
�14
T/4
2211%
93/d.
' -,-,
16' %`
-
(30) 0.162, X3h
(6j0;162)t
1, 855
5y70
5,520
'�� 5,520 `,
1,595:
4t145
4,7451
'- 4,745 =
FL
THA426-2
14
7114
261/s
93/4
-
18
-
(38) 0.162 x 31/z
(6) 0.162 x 31/z
1,855
5,520
5,520
5,520
1,595
4,745
4,745
4,745
1. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
2. Wind (160) is a download rating.
3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 11h" min.
top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying member.
For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer
applications, refer to the Nailer Table.
4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 11h" nai6 in
the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for
16 gauge and 14 gauge.
5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over
the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads.
6. Refer to installation instructions regarding fastener installation into carried Qoist) member. Based on the installation condition, nails will be installed
either straight with straighted double -shear nailing tabs or slanted.
7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
18
is
LUS/MUS/H US/H H US/HG US
Face -Mount Joist Hangers
?v�'01WO
W ® m
E
This product is preferable to similar connectors because
of a) easier installation, b) higher loads, c) lower
installed cost, or a combination of these features.
The double -shear hanger series, ranging from the. light -capacity
LUS hangers to the highest -capacity HGUS hangers, feature
innovative double -shear nailing that distributes the load through
two points on each Joist nail for greater strength. This allows for
fewer nails, faster installation and the use of all common nails for
the same connection.
For medium -load truss applications, the MUS offers a lower -cost
alternative and easier installation than the HUS or THA hangers,
while providing greater load capacity and bearing than the LUS.
Material: See tables on pp. 194-195
Finish: Galvanized. Some products available in stainless steel
or ZMAX9 coating. See Corrosion Information, pp.13-15.
Installation:
• Use all specified fasteners; see General Notes.
• Nails must be driven at an angle through the joist or truss
into the header to achieve the table loads.
• Not designed for welded or nailer applications.
Options:
• LUS and MUS hangers cannot be modified
• Concealed flanges are not available for HGUS and HHUS
• Other sizes available; consult your Simpson Strong -Tie
representative
Codes: See p.12 for Code Reference Key Chart
Double -Shear
Nailing
Top View
Double -Shear Nailing
Side View
Do not bend tab
Dome Double -Shear
Nailing Side View
(Available on
some models)
1. for 2xs
1'tie" for 4x's
o'
H
mow--/ B
VJ LUS28
43( HHUS210-2
MUS28
0
e vy
m:
c �;L
HUS210
(HUS26, HUS28,
and HHUS similar)
HGUS28-2
Typical HUS26
Installation
with Reduced
Heel Height
(multiple member
fastening
by Designer)
19
Is
LUS/MUS/HUS/HHUS/HGUS
Face -Mount Joist Hangers (cont.)
Ss'
SS
SS`
Model
Na.
Min.,
Heel!Ga:
Height
Dimensions (in.)
.Fasteners
W:
H ,B
Carryings , Carried
Member `_ � ;Member
Single 2x Sizes
'LUS24:`
2V,
18
tA-
:31A
1314
.t(4);a148x3
(2)Q.148x3,".,
LUS26 .
•41/a_'
1�/ie'
, 4s%4
131a �'
(4} fl148x S':,
(4) 0.148
x 3.
MUS26
417Ar
18
1 9/is
53A6
2
(6) 0.148 x 3
(6) 0.148 x 3
HUS26
4-A6
16
1 %
5%
3
(14) 0.162 x 31/2
(6) 0.162 x 31/2
HGUS26'-
48As'
. 12
1 W
541i
5
(20) 0.162-x 31/2
'(8) 0.162 x 3?h '<.
LUS28
-AIN
18
1IN -:
6%
- 1 ?/a
(6)�_D148 x 3 ,
(4) 0.14$ x 3
MUS28
6-516
18
1 s/is
613A6
2
(8) 0.148 x 3
(8) 0.148 x 3
HUS28
61/2
16
15/a
7
3
(22) 0.162 x 31/2
(8) 0.162 x 31/2
HGUS28
69/,s
12
15/e
71/s
5
(36) 0.162 x 31h
(12) 0.162 x 31h
-LUS210- ,
- .41/4 ,;
. 18 ',
1 Y16
773/s,
13/4
(8)(1.148.0 -
(4), 0.148 x 3
dUS210
: Ss/a.
�;16 ;
>;1.5/a
9
3
. (30) 0.162 x 31h
(10) 0.162 x 31/2
HGUS21¢
, 88fjs; .
, f
1/
.
62931/2
1 (16) 0.162 x 31h .''
1. See table below for allowable loads.
Single 2x Sizes
These products are available with additional corrosion
protection. For more information, see p.15.
For stainless -steel fasteners, see p. 21.
Many of these products are approved for installation
t with Strong-DriveO SD Connector screws.
See pp. 335-337 for more information.
LUS26
1,165
865
1 990
1,070
1 1,355
1 1,165
935
1 1,070
1,150
1,475
865
635
725
785
1,000
IBC, FL,
MU526
.. ?.°,
1,295 ,.
1,480
1,560 "':
' 1,5ii0
5 r
,1;405 .;
1,566 --
J"6na '
1 5ii
810
955 ,
1,090
° 1;!$0
_.,..
0
LA
HUS26
1,320
2,735
3,095
3,235
3:235
1,320
2,960
3,280
3:280
3,280
1,150
2,350
2,660
21780
2,780
�HGUS2fi
4,340`
�4,850`
5,17Q "�'
5 390
1s75 ,
4,690 `
;5 220,
e 5 390
= 5390
1ti0
3,225 .;
3,610
3,870
3;985 �`
IBC, FL
LUS28
1,165
1,100
1,260
1,350
1,725
1,165
1,195
1360
1,465
1,730
865
810
925
1,000
1270
MU528`
1°. 20 `'"
1730'
1,975'
2,125 "
2',255",
1,328
;. 1,875 -
""°2,135
2255
.2.2- 5
1,"i50
1;270
' 1l 455
"1575 ,
1s3 r
IBC, FL,
LA
HUS28
1,760
4,095
4,095
4,095
4,095
1 1,760
4,095
4,095
4,095
4,095
1,480
3,520
3,5203,520
3,520
HGUS28
1,6; 0
72Z-5
7,275
7;275,
7,27S,
1,6p .'
1,275` ;
7,275
'7,275•
7275
'1325 -
.-3.570,A
3,82Q.
3;915
4;250 '
IBC, FL
LUS210
1,165
1,335
1,530
1,640
2,090
1,165
1,450
1,655
1,775
2,270
865
985
1,120
1,215
1,500
IBC, FL,
HUS210
2,6335
5,450
5,795
5,830
5,X'0, `
2,835"
` 5 395` '
, 5 780
='S£i3
S';BUrT
, 2120
2 "s3v '
2,455
2,535 .
"2,825 `
LA
HGUS210
2,090
9,100
9,100
9,100
9,100
2,090
9,100
9,100
9100
9,100
`.5L:5
6.340
6,730
6:730
6,730
IBC: FL
1. For dimensions and fastener information, see table above. See table footnotes on p. 195.
HHUS/HGUS
See Hanger Options information on pp. 98-99.
HHUS - Sloped and/or Skewed Seat
• HHUS hangers can be skewed to a maximum of 45° and/or sloped to a maximum of 45"
• For skew only, maximum allowable download is 0.85 of the table load
• For sloped only or sloped and skewed hangers, the maximum allowable download
is 0.65 of the table load
• Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb.
• The joist must be bevel -cut to allow for double shear nailing
HGUS - Skewed Seat
• HGUS hangers can be skewed only to a maximum of 45°. Allowable loads are:
HGUS Seat Width Joist Down Load Uplift
W < 2" Square cut 0.62 of table load 0.46 of table load
W < 2" Bevel cut 0.72 of table load 0.46 of table load
2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load
2" < W < 6" Square cut 0.46 of table load 0.41 of table load
W > 6" Bevel cut 0.85 of table load 0.41 of table load
Acute
side
apeary angle
Top View HHUS Hanger
Skewed Right
hoist must be bevel cut)
All joist nails installed on the
outside angle (non -acute side).
94
LUS/MUS/HUS/HHUS/HGUS
These products are available with For stainless Many of these products are approved for installation
RD additional corrosion protection. ED steel fasteners, B with Strong -Drive° SD Connector screws.
For more information, see p.15. see p.21. See pp. 335-337 for more information.
SS
4
Double 2x Sizes
HHUS26-2 45A6 14 35As 5a/a 1 3 1 (14) 0.162 x 31/z (6) 0.162 x 31/z 1,320 2,830 3,190 3,415 4,250 1,135 2,435 2,745 1 2,935 3,655
HGUS26-2 49Ar, 12 3% 531r 1 4 1 (20) 0.162 x 31/z (8) 0.162 x 31/z 2,155 4,340 4,850 5.170 5,575 1,855 3,730 4,170 14,445 4,795
IBC, FL,
LA
LUS210-2 67/16 18 31/s 9 2 (8) 0.162 x 31/z (6) 0.162 x 31/z 11,445 11,830 12,075 12,245 12,830 1;245 11,575 11,785 11,930 12,435
HHUS210-2 83/a 14 3-IA. 87A 3 (30) 0.162 x 31/z (10) 0.162 x 31/z 3:550 5,705 6,435 6,4$5 6,485 3,335 4,905 5,340 5;060 5,194
HGUS210-2 8% 12 35,i6 93i6 4 (46) 0.162 x 31/2 (16) 0.162 x 31h 14,095 19,100 9,100 19,100 19,100 1 3,520 17,460 1 7,825 17,825 17,825
Triple 2x Sizes
nUUJLO J :.I
it718,,t;
Ili s,
ff,7161
eZ?Y2',
_ff,r:
I tN) U.104x.j7?
-< IaJ U.�OL, 3'l2
:Ll'I,JJ
4 iT�U�
,!$P3U
I 3j1fU
U,37J
.,1,0.70
I 0,115U,
4,
14,7 tlJ
IBC, FL,
HGUS28 3,1e 'i
61346 ,
.,.,
12
41 5a
71/a�
, ;9
{36} Q.762 x 3'/i
'(12)`0162Ix 31h
3,2 5
��11
7a1Ei0'
:7,460
`7460
7,460
2 78(�
6,415
6;415
6 415
6;415'
LA
HHUS210-3
8%
14
41146
87/a
3
(30) 0.162 x 31/z
(10) 0.162 x 31h
3,405
5,630
6,375
6,485
6,485
2,930
4,840
5,485
5,575
5,575
FL
HGUS210-3
813/i6
12
415A6
91/4
4
(46) 0.162 x 31h
(16) 0.162 x 31/z
4,095
9,100
9,100
9,100
9,100
3,520
7,825
7,825
7,825
7,825
HGUS212r3 �'
105/a '
°415fic
1031a
4' '
`(56) 0.162 x 31h
'(20) 0.162x 31/z
5,6�3
0;1745:
q 045
;
°
600"
a l8fi
"d
7,?8D
118L1
IBC FL,
.12
3645
,0
_
,?.. -
.:
LA
Quadruple 2x Sizes
rruuJLO-4 D72 r_14 '0776 OA8 !y't , ,(GUJ'U. OLXJ72 0)U.1104,XO72 41100 4,54U-= 40JU yJ,11U�'J,OfU, hmDU",3,f3U, �4rI;lU 4i4}0. 4,1.7J, IBC, FL,
HGUS28-4 71/a 12 69/e 73A6 4 (36) 0.162 x 31/z (12) 0.162 x 31h 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 LA
HHUS210-4 8% 14 61/s 87A 3 (30) 0.162 x 31/z (10) 0.162 x 31/z 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 5,575 FL
4x Sizes
IBC, FL,
LA
IBC, FL
LUS48
43/a
1 18
1 314s
63/a
1 2
(6) 0.162 x 31/z
1 (4) 0.162 x 31/2
1 i,0601,315
11,490
11,610
12,030
1 910
11,130
11,280
11,385
1,745
IBC, FL,
HUS48
61/a
14
39/i6
7
2
(6) 0.162 x 31h
(6) 0.162 x 31/z
1,320
1,580
1,790
1,930
2,415
1:135
1,360
1,540
1,660
2,075
LA
HHUS48
61/z
14
3%
71A
3
(22) 0.162 x 31/z
(8) 0.162 x 31/z
1,760
4,265
1 4,810
5,155
5,980
i'51 5
3,670
4,135
4,435
5,145
HGUS48
67A6
12
35/s
71ti6
4
(36) 0.162 x 31/z
(12) 0.162 x 31h
3,2351
7,460
7,460
7,460
7,460
2,780
6,415
6,415
6,415
6,415
HGUS412 107/is 12 3% 107tis 4 (56) 0.162 x 31/2(20) 0.162 x 31/2 5,695 9:045 9,045 9;045 9,045 4,900 7,780 '•,780 1 7,780 17,780
HGUS414 I 117A6 1 12 1 35/a 127A6 4 1 (66) 0.162 x 31/2(22) 0.162 x 31h 5,695 10,125 10,125 10,125 10,125 4,900 8,190 8,190 8,190 18,190
Double 4x Sizes
IBC, F
LA
FL
1. Uphft bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
2. Wind (160) is a download rating.
3. Minimum heel height shown is required to achieve full table bads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com.
4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSVFPI 1-2014. Simpson Strong -Tie® Connector Selector® software includes
the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21h" nails in the header
and 0.162" x 31h" in the joist, with no bad reduction. With single 2x carrying members, use 0.148" x 11h" nails in the header and 0.148" x 3" in the joist,
and reduce the load to 0.64 of the table value.
6. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information.
W
19
HTU
Face -Mount Truss Hanger
The HTU face -mount truss hanger has nail patterns
designed specifically for shallow heel heights, so that
full allowable loads (with minimum nailing) apply to
heel heights as low as 37/e". Minimum and maximum
nailing options provide solutions for varying heel
heights and end conditions.
Alternate allowable loads are provided for gaps
between the end of the truss and the carrying member
up to 1/2" max. to allow for greater construction
tolerances (maximum gap for standard allowable loads
is 1/e" per ASTM D1761 and D7147). See technical
bulletin T-C-HANGERGAP at strongtie.com for
more information.
Material: 16 gauge
Finish: Galvanized
Installation:
• Use all specified fasteners; see General Notes
• Can be installed filling round holes only, or filling
round and triangle holes for maximum values
• See alternate installation for applications
using the HTU26 on a 2x4 carrying member or
HTU28 or HTU210 on a 2x6 carrying member
for additional uplift capacity
Options:
• HTU may be skewed up to 671/2'. See Hanger
Options on pp. 98-99 for allowable loads.
• See engineering letter L-C-HTUSD at strongtie.com
for installation with Strong -Drive® SD fasteners.
Codes: See p.12 for Code Reference Key Chart
Min. heel
height
per table
Many of these products are approved for installation with Strong -Drive°
SD Connector screws. See pp. 335-337 for more information.
13/4
HTU26
Typical HTU26
Minimum Nailing
Installation
,,,�..,. yr, „ �"„ .,,
truss and carrying member
HTU Installation for
Standard Allowable Loads
(for 1/2" maximum gap,
use Alternate Allowable Loads.)
Standard Allowable Loads (1/8" MaXIMUm Hanger Uap)
Alternate Installation -
HTU28 Installed on
2x6 Carrying Member
(HTU210 similar)
a
Min:
Dimensions (in.)
Fasteners din.) .
DF/SPAllowable�Loads�`
SPF1HFAliowable.Loads , _
"
Model
No. ' ,
Heel
Height
. -
�
H
g
Carrying
Cairied °� _
� Uplift
Floor � Snow�.Roof ,
Wind
,Uplift
Floor _
Snow � "Roof 1Nrnd.
Code
Ref.
,W ,
Member
Member,
(160)
(100)
_ (115). (125)
. (160)'°
(160)
(100)
.(115) i(125} '(160),
'
Single 2x Sizes
HIll26
1�e
5Ma
31h
(20)0.162x31/z.20.18x1'
2,60
%ad,55,
6,4
,
k0
`.1(
HTU26,(Mlri.) ;
3?la`;1$/s
:5��s.
31/a{20)0:162X31h
(1? 0:148x1?/2
a,250,
2,940
''320p.e ,200.'3,200
1,075;
.1,852''
2,415
_2;0J5.�
2;015;
HTU26 (MaxJ ...
75'l ;
13/e
"5 s'
31h
'.;(20) 0162x31/z,
�(2Q) 0:148x1,"h
' 1,555
2,940;,',
3 2tS, 1 58i3
.,4,'bl'b
1; 535
2530
� ���
;p ��'��
3,450''
IBC,
HTU28 (Min.)
1 31/a
15/e
71fis
37/2
(26) 0.162 x 31/2
(14) 0.148 x 11/2
1,235
3,820
3,895 3,895
3,895
1,060
2,865
2,920
2,920
2,920
FL,
HTU28 (Max.)
1 71/4
15/e
71/a
31h
(26) 0.162 x 31/2
(26) 0.148 x 11/2
2,020
3,820
4,315 4,655
5,435
1,735
3,285
3,710
4,005
4,675
LA
Double 2x Sizes
HTU28-2 (Min.) 1 31A 3% 71tie 31/2 (26) 0.162 x 31/2 1 (14) 0.148 x 3 1,530 3,820 1 4,310 1 4,310 4,310 11,315 2,865 1 3,235 3,235 3,235 IBC,
FL,
HTU28-2 (Max.) 71/4 3-5Se 71tie 31/2 (26) 0.162 x 31/2 (26) 0.148 x 3 3,485 3,820 4,315 4,655 5:825 2,995 3,285 3,7 0, ` 4#'305 :5F01i. LA
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch.
3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
4. Wind (160) is a download rating.
5. For hanger gaps between 'A" and 1h", use the Alternate Allowable Loads.
6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector° software
includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11h" nails in the header and
reduce the allowable download to 0.70 of the table value. The allowable uprd is 100% of the table bad.
96 8. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information.
E
HTU
Face -Mount Truss Hanger (cont.)
f Many of these products are approved for installation with Strong -Drive®
SD Connector screws. See pp. 335-337 for more information.
Alternate Installation Table for 2x4 and 2x6 Carrying Member
F 940A °�,
HTU26 (Min.)
37/a
1 (2) 2x4
(10) 0.162 x 3'h
(14) 0.148 x 1'/z
925
1 1,470
1 1,660
1 1,790
1 1,875
1 795
1 1,265 1
1,430
1 1,5'0
1,615
HTU26 (Max.)
5'/z
(2) 2x4
(10) 0.162 x 3'/z
(20) 0.148 x 1'/z
1,240
1 1,470
1,660
1 1,790
2,220
1065
1,265 1
1,430
1 11,540
1,910
IBC
HTU28 (Max}
. ,7�/4
;(2)4x6
'(20) 0.162 x3ih
(26}'WO x 1'lz'
1,970 ]"
2,940
=' , 2 , ,
* 580, ,�
,3;805
1695
2,530 ,�
2, 5a .
8,080 ;'
3,360"
FL, LA
(2) 2x6 1 (20) 0.162x3'h ((32)-0;14$ X 11%z'�=,
1. See table above for dimensions and additional footnotes.
2. Maximum hanger gap for the alternative installation is'h".
3. Wind (160) is a download rating.
4. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information.
Alternative Allowable Loads (1/2" Maximum Hanger Gap)
3,360
Mm:
Dimensions (in.)
Fa'sfeners (in )
DF/SP Allowable Loads°
' SPF/HFAI(owable loads
Model ,
No
H6el
Height
IN.
H _
„ B
Carrying.
Member
Carved
Member "
Uplift
(160)
Floor
„,(100}/
,Snow
(115)
-Roof
(12.5)
Wind ,
,`(160)
Uplift
(160) _
-Floor
_(100)
Snow
-(115)
- _Roof
(125)
Wind
(160)a
Code
Ref.
Single 2x Sizes
HTU26' ,
. 3'/z
sh.
57/16"
3Jz
(20)'0.162x3'/z,
r(1`f) 0148x 1'/z
6 5
9a , 5
95
2a9
o4a
` ." 10
„ TC}
j,� a
.1, ?:
HTU26 (Mm } .
37/a
I'/a :
57/1e '
3'h -,
(20) 0 T62 x 3'lz
(14} t)`148; x 1'h'
1175
2 940 3;100
3100
.3,10Q ,
1 010
,1955
1;955 `
1 955
1955
H fU26,(Max.)
5'lz .
, i sh" ,
51'a
3'lz ,
(24) 01fi2 is 3'lz
(20) 0;148 x 1'h'
1215 '
2,940 3 4
,58t1
«iruF3
t045
850
°
2 $
2,285
IBC,
HTU28 (Min.)
37/a
15/a
7146
3'/2
(26) 0.162 x 3'/2
(14) 0.148 x 1'/z
1,110
3,770 3,770
3,770
3,770
955
2,825
2,825
2,825
2,825
FL,
HTU28 (Max.)
7'/4
1 %
71AG
3'/z
(26) 0.162 x 3'/z
(26) 0.148 x 1'/z
1,920
3,820 4,315
4,655
5,015
1,695
2,865
3,235
3,494
3,765
LA
HT(J210 (Mm,) `
' 3✓a
15/a
9b56.,
-3'h
(32)-0 i62 x 3'/z
(14) U.148 x,11h
1,25 0
3;600 3,640
3,600
3,640'..
1,075
2,700
2,700 ..
2,700
2;700'
HTU210 (Max) , ,
,9'/4
,15/a
„ 915a'
3'h
(32) 0.162'x 3y/z
(32} 0.148 x 11h
3,255,
4,705 5�020
5;O24 `
5,020 �,
2,800
3,530
31765,
°3;7fi5 .
; 3;765
Double 2x Sizes
HTU28-2 (Min.) I 37/a 13-/1e 7'1A6 3'/z (26) 0.162 x 3'/z I (14) 0.148 x 3 11,490 13,820 13,980 13,980 3,980 11,280 12,865 ( 2,985 12,985 2,985 I IBC,
1 FL,
HTU28-2 (Max.) 1 7'/4 3511,, 1 7'/ia 1 3'/2 (26) 0.162 x 3'/z (26) 0.148 x 3 13,035 13,820 4,315 4,655 5,520 2,610 2,865 13,235 3,490 4,14C LA
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch.
3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
4. Wind (160) is a download rating.
5. For hanger gaps between'/a" and'h°, use the Alternate Allowable Loads.
6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSUTPI 1-2014. Simpson Strong -Tie® Connector Selector® software
includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 1'/z" nails in the header and
reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad.
8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
19
HU/HUC/HSUR/L
Medium -Duty Face -Mount Hangers
HU/HUC hangers may be installed on a masonry/concrete wall
as described below. Additionally, HU hangers with one flange
concealed may be installed similarly.
HU and HUC products are heavy-duty face -mount joist hangers
made from 14-gauge galvanized steel.
• The HUC is a concealed flange (face flanges turned in)
version of the HU.
• HU is available with both flanges concealed, provided the
W dimension is 25he" or greater, at 100% of the table load.
Specify HUC.
• HU is available with one flange concealed when the W dimension
is less than 25/,e" at 100% of the table load. Specify as an 'X'
version and specify flange to conceal.
• For any HU or HUC shown in this catalog, the user may
substitute all face nails with 1/4" x 13/4" Titen® 2 screws
(Model TTN2-25134H) for concrete and x 2�44' Titen 2
screws (Model i fN2-25234H) for GFCMU. Follow all
installation instructions and use the loads from the sawn
lumber or E1N,JP sections.
Material: 14 gauge
Finish: Galvanized; ZMAX® and stainless steel available
Installation:
• Attach the hangers to concrete or GFCMU walls using
hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" —
Model TTN2-25234H) and for concrete (1/4" x 13/4" — Model
TTN2-25134H) are not provided with the hangers.
• Drill the 3/,a"-diameter hole to the specified embedment
depth plus 1/2".
• Alternatively, drill the 3/,a"-diameter hole to the specified
embedment depth and blow it clean using compressed air.
• Caution: Oversized -diameter holes in the base material
will reduce or eliminate the mechanical interlock of the
threads with the base material and will reduce the anchor's
load capacity.
• Titen Installation Tool Kts are available. They include a
3/,e" drill bit and hex -head driver bit (Model TTNT01-RC);
a She" x 41/2" drill bit is also available (Model MDB18412).
• A minimum edge distance of 11/2" and minimum end distance
of 37/a" is required as shown in Figure 1 for full uplift load.
• Where no uplift load is required, a minimum end distance
of 11/2" is Permitted.
Codes: See p.12 for Code Reference Key Chart
Concealed flanges
HUC410
Figure 1 — HUC410 Installed on
Masonry Block End Wall
Figure 2 — HUC410 Installed on
Masonry Block End Wall
a
23
HU/HUC/HSUR/L
Medium -Duty Face -Mount Hangers (cont.)
1* These products are available with additional corrosion protection. For more information, see p.15.
Mode(. ' '
Fasteners - .
Allowable Loads (DFISP)
No
Cn)
`dCMU
Concrete
Code,
5tantlard
Concealed
6FCMU
Goncrete
Joist °
Uplift
Down
Uplift
Down
Ref."
Tden� 2qt
TitenO 2
(160)
e° (1001125)
s
_...
N .. . .
HU26
HU26X
(4) 1/4 x 23/4 4
(4) 1/4 x 13/4
(2) 0.148 x 11h
335
1,000
335
1,545
HL128 '`
H1128X •
(6)1CX 17"{6)1IaX
13/4,
(4) 0148�X 1'Iz
545
1500:�
760
a, s2 400
HU24-2
HUC24-2
(4)1/4 x 23/4
(4)114 x 13/4
(2) 0.148 x 3
380
1,000
380
1,545
,HU26-2(Mm� ""
- HUC26.2
(4)? 23i'a
�(4)0148'X<3
'760,
2,000�-=
�'760
3200
(Max )
C26 ,
(12)/x23
_{12)'/za
a,/
01-
000HU26-2
,
1,1 5
3 950 °
HU26-3 (Min.)
HUC26-3 (Min.)
(8)114 x 23/4
(8) 1/4 x 13/4
(4) 0.148 x 3
760
2,000
760
3,200
HU26-3 (Max.)
HUC26-3 (Max.)
(12)1/4 x 23/4
(12)1/4 x 13/4
(6) 0.148 x 3
1,135
3,000
1,135
3,950
HU28 2 (Min.)
HUC28
(10}'!a x 23l ,-
(10)1/4X 131a
(4) D 148.x3
760
�° 2,500`
76Q
�ti3 725 . ,
8- Mai.},
HUC28-� (Max.)
°"�
(14} i/4 x 23/a_
(14)114 x 13K
',(6) 014$ X3
�1135
, ; 3,500
1 i35
HU210
HU210X
(8)1/4 x 23/4
(8)1/4 x 1 3/4
(4) 0.148 x 11/2
545
2,000
760
2,415
H0210-2 (Mn)
WC,210-2 (Min.}
(14) l x 23/a ";',
(14)'la x 13Ia '"
>(6) 0148 1_3
7135
3 500 I,
1 l35
4 920
_"
,�
HU210.2 (Max:)"
_ HUC210 2 (Max-}.-„{18)'/a
X 1?/a "-
. '{10}`0.148 z 3
1800
4;50D
1,800
5 085
HU210-3 (Min.)
HUC210-3 (Min.)
(14) 114 x 23/4
(14)1/4 x 13/4
(6) 0.148 x 3
1,135
3,500
1,135
4,920
HU210-3 (Max.)
HUC210-3 (Max.)
(18)114 x 23/4
(18)1/4 x 13/4
(10) 0.148 x 3
1,800
4,500
1,800
5,085
HU21
HU212X
3T ,0)Ye,3/a`
,p
.,2;500/rx
71 5
2 665 :'
HU212-2 (Min.)
HUC212-2 (Min.)
(16)1/4 x 23/4
(16) 1/4 x 13/4
(6) 0.148 x 3
1,135
4,000
1,135
4,920
HU212-2 (Max.)
HUC212-2 (Max.)
(22)1/4 x 23/4
(22)1/4 x 1 3/4
(10) 0.148 x 3
1,350
5,085
1,350
5,085
HU212 3 {Min)
-': HUC212 3 {Min . ;
(16);1/a x 23/a .: >'
{16)'I4'x 13Ia
(6} 014$ z 3� .
°_`1135
4;000
Y,;�35
4,920 "
H2 3 (
(M
(22)1/4U21
13
0Max)
,
800
5,085.
5,0$5 "/a
-
HU214
HU214X
(12)114 x 23/4
(12)114 x 13/4
(6) 0.148 x 11/2
1,135
2,665
1,135
2,665
HU214 2 (Min j. ,
HUC219 2 (Min) " `
(18)1/a x 23/a \
{18)'/dx 13Ia
(8) 0,148k 3
7 515
4 500
HU214-2 (Max.)
HUC214�-2 (Max:). °
(24)1/4 x 23/a
(24)1/4,x1'14 " ,
' (12} 014S.X 3.
2,013 - -
5,085
2,015 "
5,085 "
HU214-3 (Min.)
HUC214-3 (Min.)
(18)1/4 x 23/4
(18)1/4 x 13/4
(8) 0.148 x 3
1,515
4,500
1,515
5,085
HU214-3 (Max.)
HUC214-3 (Max.)
(2 4) 114 x 23/4
(24)114 x 13/4
(12) 0.148 x 3
2,015
5,085
2,015
5,085
HU216 w
HU216X
(1"8)?lax 23/4 °. "F
{18)'Ia it;?/g
(8) 0.148 x 1yh
y ; 7,515
2 920 tl
1',515
i^
" 2 920
HU216-2 (Min.)
HUC216-2 (Min.)
(20)114 x 23/4
(20)114 x 13/4
(8) 0.148 x 3
1,515
4,920
1,515
4,920
HU216-2 (Max.)
HUC216-2 (Max.)
(26)1/4 x 23/4
(26) 1/4 x 13/4
(12) 0.148 x 3
2,015
5,085
2,015
5,085
'HU21&3 (Min)
HUC216'-3 (Min) °'`
(20);/a, x 231a ''
{20)1/a x 13/i`
1 515
°. 41920
1,515
4920
HU216 3 (Max.) "',
HUC216-3 (Mai.), =_
`(26)7Ig x 23/4 '
(26)'la x 13/4 ,
" (12) 0.148 x 3
2 015
HU7 (Min.)
(Not available)
(12) 1/4 x 23/4
(12)1/4 x 13/4
(4) 0.148 x 11/2
545
2,980
760
2,980
HU7 (Max.)
(Not available)
(16)1/4 x 23/4
(16)1/4 x 13/4
(8) 0.148 x 1 %
1,085
3,485
1,085
3,485
HU9 {Min)
{Not available)
(18)1Jax 23I4
{18)°'/a X 13/a
' (6) 0148 x-''h
u, : 7,135°
A 3;230
1,135
3,230
HU9 (Max) o
(Not available)
x l 3/41445
3,7351;445
3 735
HU11 (Min.)
(Not available)
(22) % x 23/4
(22)1/4 x 13/4
(6) 0.148 x 1112
1,135
3,230
1,135
3,230
HU11 (Max.)
(Not available)
(30) 1/4 x 23/4
(30)114 x 13/4
(10) 0.148 x 11h
1,445
3,735
1,445
3,735
HU14 (Min)
{Not available} < ° -,
(2$):'/a x 23/a
(28)?/ax 13/a ,
(8) 0148 x 1h
1 5J5 e"'
3,485
1;5i5
_" 3,485
HU14. Max
Notavalable
36 :1/a x 23Ia F
36 'lax 1.31a
14 0148 x 11/2
2 015
4 245
2;D15
4,245
a
38
STAGGER JOINTS - TYP.T
A/9K1�,
UPLIFT/SHEAR ANCHOR —
EACH TRUSS - SEE 5/5KIf'
PLAN
NOTE: ADVL FRAMING NOT
SHOWN FOR CLARITY
RAISED HEEL TRUSS BEARING'A
SCAM Nis SKl
RA15ED HEEL ROOF TRU55ES
SEE PLAN
ROOF SHEATHING- SEE I
SOFFIT/FASCIA- SEE ARCH.
RAISED HEEL ROOF TRUSSES
-SEE PLAN
RIBBON BOARD -
SEE SCHEDULE
FOR SPACING d
JBBON BOARD- SEE
FASTENING TO w IDCHEDULE
FOR SPACING t
TRU65E5
45TENING TO TRUSSES
WALL SHEATHING-5EE PLAN
MIN. 15/32' COX PLYWOOD OR
1/16' 05B WITH ed GUN NAILS
-MASONRY WALL-
(0.131' X 2 1/2') 9 6' O.G. TO
UPLIFT/SHEAR GYP. CEILING-
SEE PLAN
RIBBON BOARDS
ANCHOR EACH SEE PLAN 4
TRU55- SEE PLAN SCHEDULE
DO NOT FASTEN RIBBON BOARD
INTO END GRAIN OF ROOF TRUSS
MASONRY WALL -
BOTTOM CHORD
SEE PLAN
RAISED HEEL TRUSS BEARING B
SCALE: NTS SKI
RIBBON SCHEDULE
DESIGN CRITERIA
RIBBON MATERIAL
RIBBON SPACING
RIBBON ATTACHMENT
Vult=165 MPH
(2) 12d GUN (0.131' X 39
(Vasd=128 MPH)
2X4 SPFM2
24'
TO EACH TRUSS, (4)
EXP. 5,
ENCLOSED
NAILS AT JOINTS
Vult=180 MPH
(VasXP. MPH)
(2) 12d GUN (0.131' X 3')
EXP. G,
E
2X4 5PF02
16,
TO EACH TRUS5, (4)
ENCLOSED
I
NAILS AT JOINTS
RIBBON OflM FOR '
RNSED KM ROOFIW..
Im 0V:
SK.I
ALPIN, E�
, M fTWCOVW�
January 1Q,2U20'
Catpbfiter-Coritractors dAmericd, Inti.
'3,960,Aven 6 di NW,
Wiriter.* Havoi, FL 3.3,BM62,01
Dear Matt-
Ithas come ,to' my aitentiGmthat,SqMe questions were raised concerning diameter'
de face) ofsys42gq pdi fe or,
ifi"rea&d rods If, th'es-b:ga : ble endsare aver continuous supp
ort. _Ort:
with oflo"f4.c'e,,Iful,ly,;sh'ea.th'e,,dt e illed the;wide
are.drilled about
face thdur Ar ; any 1 1 11 . -11 .. � t; C;- I
amagingConned or"plate's --,o""'rvertical; "webs then
no.repair"i�re.q�tre�d.�Thetmls.goi,y:supports��'fei6t'flbo !bad dn"d'nd additional:
load...
lf,you 'have any. :questions; please give -mle:a.:.call.l
Sincerely;
Y,
rel
Nd,;86361-
STATE , QF
Yoonhw.
1
6,750 :F6ru m Drive,9 FL �k _(400),
', Suite 30
�o mie, 521.W90-186442216685
�5�y�i�ea o i•trtixtajr
a
No. 86367
STATE OF 20
ONA� b
This lem ntvrg has been ehsctr-M— r signet'
and welted using a iTVW Stgnakne. Pdr tsd
copies wi#routsn orip W she must be
verified using Ow oti&W electronic version.
ALPINE
AN IiW COMPANY
Ft, REG# 278- Yoonhwak Kim,, FL PE 486367
Alpine, an ITW Company
675E Forum Drive, Suite 305
Orlando, FL 32821
Phone:(800)755-6001
www.alpineitwcom
Site Information: __.. ..
Pago 1:
Customer. Carpenter Contractors of America
I Job Number.' N333986
Job Description: 7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELE,V.D
Address:
Job,En inee"rin C..riteita.":-, -
Design Code: FBC 6th ed 2017 IntelliVIEW Version: 17,02.02A through 1'8.02.01A
_ JRef'#: 1 WXQ89750106
Wind Standard: ASCE 7-10 Wind Speed (mph) 160 Roof Load (pso., 20.00- 7,00- 0.00-10.00
Building Type: Closed FloprLoad ps : None
This package contains general notes pages; 27 truss drawing(s) and 5 detail(s).
Rena
J Drawing Number __
Truss, , '.
1
224.20.1548.12211
Al
3
224,20.1548.13631
A2
5
224.20.1548.12461
A4
7
224.20:1548.17859
A6
9
224,20.1548,17936
A10G
11
224.20,1548.18155
A9
13
224.20.1548.17702
B1
15
224.20.1548.17266
C1GE
17
224.20.1548.17579
MV01
19
224.20.1548.13865
EJ7
21
224.20.1548.17749
EJ7S.
23
224.20.1548A 7562
CJSA
25
224.20.1548.18092
CJ3A
27
224.20.1548.13756
HJ7
29 IA18015ENC101014
31 1
GBLLETIN1014
ifiain
Drawing: Number
Truss:
2
224,20.1548.12554
A1A
4
224.20.1548„13787
A3
6
224.20.1548.13709
A5
224.20.1548.23911
A7
10
224.20A 548.23974
A8
12
224.20,1548.23896
A 11 G
14
224.20.1548.17952
B2GE
16
224.2M 548.23897
V4
18
224.20.1548:18077
MV02
20
224.20.1548.17858
EMA
22
224.20.1548,13975
CJ5
24
224.201548.12587
CJ3
26
224.20.1548,13974
CJ1
28
A16015ENC101014
30
GBLLETIN0118
32 1
VAL160101014
FWt4a Certificate of Product Approval #FL1999 Printed 8/1112020 4:06:34 PM
•
General Notes
Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities:
The design responsibilities assumed in the preparation of these design drawings a"re those specified in ANSI/TPI 1,
Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate
Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design
Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and
dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to
independently verify the accuracy or completeness of the information provided by others and may rely on that information
without liability. The responsibility for verification of that information remains with others neither employed nor controlled
by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page
listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component
designs and not for the technical information furnished by others which technical information and consequences thereof
remain their sole responsibility.
The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in
accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and
loads for each truss component match those required by the plans and by the actual use of the individual component, and
for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any
additional factors required in the particular application. Truss components using metal connector plates with integral teeth
shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to
exceed 19% and/or cause corrosion of connector plates and other metal fasteners.
The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set
forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss
component design loads, inspection of the truss components before or after installation, the design of temporary or
permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear
walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the
foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports,
installation of the truss components, observation of the truss component installation process, review of truss assembly
procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in
the installation of the truss components and/or its connections.
This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic
file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request.
Temporary Lateral Restraint and Bracing:
Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2,
B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or
other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these
drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to
and may not be relied upon for the temporary stability of the truss components during their installation.
Permanent Lateral Restraint and Bracing:
The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of
the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of
BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional.
These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building
stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building
Designer.
Connector Plate Information:
Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations,
gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60.
Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at
www. icc-es.oro.
Fire Retardant Treated Lumber:
Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all
stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special
handling care must be taken to prevent breakage during all handling activities.
Pagel of 3
General Notes (continued)
Key to Terms:
Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed
information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be
found in calculation sheets available upon written request.
BCDL = Bottom Chord standard design Dead Load in pounds per square foot.
BCLL = Bottom Chord standard design Live Load in pounds per square foot.
CL = Certified lumber.
Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot.
FRT = Fire Retardant Treated lumber.
FRT-DB = D-Blaze Fire Retardant Treated lumber.
FRT-DC = Dricon Fire Retardant Treated lumber.
FRT-FP = FirePRO Fire Retardant Treated lumber.
FRT-FL = FlamePRO Fire Retardant Treated lumber.
FRT-FT = FlameTech Fire Retardant Treated lumber.
FRT-PG = PYRO-GUARD Fire Retardant Treated lumber.
g = green lumber.
HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches.
HORZ(TL) = maximum Horizontal panel point Iona term deflection in inches, due to Total Load, including creep
adjustment.
HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds.
Ic = Incised lumber.
FJ = Finger Jointed lumber.
L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value.
L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the
referenced panel point. Reported as 999 if greater than or equal to 999.
Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection.
Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases.
Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases.
Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases.
NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot.
PL = additional Load applied at a user specified angle on a truss -Piece in pounds per linear foot or pounds.
PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds
PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds.
PP = Panel Point.
R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc).
-R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc).
Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the
indicated location (Loc).
RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic)
load cases, at the indicated location (Loc).
Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the
identified location (Loc).
TCDL = Top Chord standard design Dead Load in pounds per square foot.
TCLL = Top Chord standard design Live Load in pounds per square foot.
U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the
indicated location (Loc).
VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in
inches.
VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and
maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment.
VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load.
VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment.
W = Width of non -hanger bearing, in inches.
Refer to ASCE-7 for Wind and Seismic abbreviations.
Uppercase Acronyms not explained above are as defined in TPI 1.
Page 2 of 3
References:
1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.orq.
2. ICC: International Code Council; www.iccsafe.org.
3. Alpine, a division of ITW Building Components Group Inc.: 13723 Riverport Drive, Suite 200, Maryland Heights, MO
63043; www.alpineitw.com.
4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.orq.
5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com.
Page 3 of 3
SEQN:7009/ COMN Ply: 1 Job Number: N333986 Cust:R8975 JRef: 1 WXQ89750106 T1 8
FROM: RWM Qty: 8 7A5/320 ,167ED ,RG01 / 1672/RRIA14EAB ELEV.D DrwNo: 224.20.1548.12211
Truss Label: Al KD / YK 08/11/2020
6'1"7 125 19'4" 25'11"1 32'6"9 38'8"
6,1"7 6'7"8 6'7"1 6'7"1 6'7"8 6'1'7
=5X5
E
38'8"
10' 19'4" 28'8"
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
TCDL: 7.00
Speed: 160 mph
Pf: NA Ce: NA
VERT(LL): 0.208 K 999 360
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(CL): 0.361 K 999 240
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.076 J - -
Des Ld: 37.00
XP: C Kzt: NA E
HORZ(TL): 0.132 J - -
Building Code:
NCBCLL: 10.00
Height: 15.00 ft
Mean Hei
TCDL: ei psf
Creep Factor: 2.0
Soffit: 0.00
BCDL: 5.2 psf
FBC 6th.ed 2017
Max TC CSI: 0.532
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Max BC CSI: 0.886
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Rep Fac: Yes
Max Web CSI: 0.490
Loc. from endwall: not in 9.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
VIEW Ver: 17.02.02A.1213.21
Wind Duration: 1.60
WAVE
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord: 2x4 SP #2 N; _
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N;
Lumber value set "1313" uses design values approved
1/30/2013 by ALSC
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint
to be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113'W.5",min.). Restraint material to be
supplied and attached at both ends to a suitable
support by erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2)
scabs for (2) CLR'S where shown. Scab
reinforcement to be same size, species, grade, and
80% length of web member. Attach with 0.128x3" gun
nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom
chord live load in areas with 42"-high x 24"-wide
clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
%'i®if liifl#fef
i
9 0
STATE OF
10, 11
38'8"
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1661 /- /- /936 /301 /433
H 1662 /- /- /936 /301 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.0
H Brg Width = 8.0 Min Req = 2.0
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1442 - 3042 E - 5 1073 -1962
C - D 1343 - 2764 F - G 1343 - 2765
D - E 1073 -1962 G - H 1442 - 3043
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - L . 2659 -1146 K - J 2202 - 861
L - K 2202 - 835 J- H 2660 -1148
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
L - D 520 -199 K - F 471 - 725
D - K 471 - 724 F - J 521 -199
E - K 1318 - 632
®� ry
NAI. �
41J4461iii4l°
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11 /2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI an SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have prplogattached structural sheathing and bottom chord shall have a properly
attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 1310,
as applicable. App�y plates to each face o truss and position as shown above and on -the Join Details, unless noted otherwise. Defer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildingComponents Group Inc. shall not be resRonsible for any deviation from this drawing, any failure to build the ANf COMPAW
truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracincLof trusses. A seal on this drawing or cover pacie
listing this drawingg indicates acceptance of professional en ineenng responsibilitty� solely -for the design shown. The suitability and use of This 6750 Forum Drive
drawing for any sfructure is the responsibility of the Buildingg esigner per ANSI/TPI 1 Sec.2. Suite 305
F& more information see these web sites: Alpine: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.icesafe.org Orlando FL, 32821 i
Job Number: N333986 Ply: 1 SEQN: 7010 / T23 / COMN Cusl: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RDP DrwNo:. 224.20.1548.12554
Truss Label: AtA TCE / WHK 08/11/2020
21'1"12
1'9"12
T10"14 12'r'12 17'10"4 19'4" 26'6"4
f 7'10"14 �— 4'2"14 S'8"8 1,512 t 5'4"8
=5x5
F
38'8" —
30'9"2 38.8"
47"14 7'10".
1' 7'11"5
f' T
4'0"11 6' 3' 5'8" 40"11 T11"5 1'
7'11"5
12' 18' 21' 26'8" 'f" 30'8"11T 38,8" �.' '{
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl U#
Loc R / U / Rw / Rh / RL
/ W
TCDL: 7.00 Speed: 160 mph
Pf: NA Ce: NA VERT(LL): 0.201 E 999 360
B 1518 / 301 / 936 / - / 433
/ 8.0
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.549 E 999 240
J 1518 1301 / 936 / - / -
/ 8.0
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.100 L - -
Wind reactions based on MWFRS
Des Ld: 37.00 EXP: C
HORZ(TL): 0.186 L
B Min Brg Width Req = 2.1
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Code / Misc Criteria Creep Factor: 2.0
J Min Br Width
g Req = 2.1
Soffit: 0.00 BCDL: 5.0 psf
p
Bldg Code: FBC 6th ed.201 Max TC CSI: 0.739
Bearings B & J are a rigid surface.
g g
Load Duration: 1.25 MWFRS Parallel Dist: h to 2h
TPI Std: 2014 Max BC CSI: 0.793
Bearings B & J require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft
Rep Factors Used: Yes Max Web CSI: 0.825
Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft
FT/RT:20(0)/l0(0)
Maximum Top Chord Forces Per
Ply (Ibs)
GCpi: 0.18
Plate Type(s):
Chords Tens.Comp. Chords
Tens. Comp.
Wind Duration: 1.60
WAVE VIEW Ver: 17.02.01A.1115.21
Lumber
B - C 1385 -2665 F - G
1456 -2370
C - D 1300 - 2278 G - H
1327 - 2399
Value Set: 13B (Effective 6/1/2013)
D - E 1316 -2355 H - 1
1299 -2276
Top chord 2x4 SP #1 :T2, T3 2x4 SP #2 N:
E - F 1434 -2326 I - J
1386 -2665
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3 :W6, W9 2x4 SP #2 N:
Maximum Bot Chord Forces Per Ply (Ibs)
Lumber value set "l3B" uses design values
Chords Tens.Comp. Chords
Tens. Comp.
approved 1/30/2013 by ALSC
B - U 2299 -1067 M - L
2298 -1076
Plating Notes
U - T 2297 -1066 L - J
2300 - 1076
All plates are 2X4 except as noted.
j 111(t i P ►p
R - N 1841 - 645
Wind
���`® �:
Maximum Web Forces Per Ply (Ibs)
Wind eed on MWFRS with additional C&C
® 01�� ��C+ @� �®+°gyp
WebsT Webs
Tens. Comp.
membeades gds
�®®`®'`�+
C 305Com4p6
* The lower
section of ttom Chord
oS
No. 86367 � �
T - R 2100 -903 N - M
2114 929
between0panel points O andmay,
�°
a C�
R - F 1050 -712 M - 1
308 -451
be field -removed as required provided that
all remaining plate/wood contact areas stay
10
o
intact and undisturbed.
9
`�
a STATE OF
N'Ag
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handling,shipping, installingand bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proerly
�id ceilin Locations shown for -permanent lateral restraint of webs shall have bra installed per BCSI sections B3, B7 or B10
le. Afplgji plates to each face oftruss and position as shown above and on the Joint9Details, unless noted otherwise. Refer to'
60A-Z for standard plate positions.
a division of
more
r I HI 1; or for r
acceptance
any structure
any deviation from this drawing,any failure to build the
1g oftrussesA seal on this drawing or cover page.
sibility solely for the design shown. The suitability
)esignerper ANSI/TPI1 Sec.2.
TPI: www.tpinst.org; SBCA: www.sbcindus".com; ]CC: www.iccsaf
ALPINE
AN mN COWANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 328:
Job Number: N333986 Ply: 1 SEQN: 7011 / T17 / SPEC Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D City: 2 FROM: RWM DrwNo: 224.20.1548.13631
Truss Label: A2 KM / OF 08/11/2020
6'1"7 12'8"15 19' 25'11"1 32'6"9 38'8"
6'1"7 6'78 6'3"1 6'11"1 6'7"8 6'1"7
=5X5
E
�1'+ 10'
10'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP 92 N
Bot chord 2x4 SP #1
Webs 2x4 SP #3 :W3, W4, W5 2x4 SP #2 N
Lumber value set "13B" uses design values
approved 1/3012013 byALSC
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint
to be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be
supplied and attached at both ends to a suitable
support by erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2)
scabs for (2) CLR'S where shown. Scab
reinforcement to be same size, species, grade, and
80% length of web member. Attach with 0.128x3" gun
nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom
chord live load in areas with 42"-high x 24"-wide
clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
38'8"
18.8"
28'8"
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
Pf: NA Ce: NA
VERT(LL): 0.208 K 999 360
Lu: NA Cs: NA
VERT(TL): 0.515 K 999 240
Snow Duration: NA
HORZ(LL): 0.076 J - -
HORZ(TL): 0.132 J
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 6th.ed 201
Max TC CSI: 0.532
TPI Std: 2014
Max BC CSI: 0.886
Rep Factors Used: Yes
Max Web CSI: 0.489
FT/RT:20(0)/10(0)
Plate Type(s):
VIEW Ver: 17.02.01A.1115.21
WAVE
,aotIaItit Ifffhpp
N� WAS ;P
Nv.86367 a
® e
a� STATE OF ,
10' 1'
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 1661 1298 / 934 / - / 427 / 8.0
H 1662 / 298 / 934 / - / - / 8.0
Wind reactions based on MWFRS
B Min Brg Width Req = 2.0
H Min Brg Width Req = 2.0
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - C 1422 - 3042 E - F 1052 -1962
C - D 1323 - 2764 F - G 1323 - 2765
D - E 1052 -1962 G - H 1423 - 3043
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - L 2659 -1128 K - J 2202 - 847
L - K 2202 - 818 J - H 2660 -1133
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
L - D 520 - 200 E - K 1317 - 635
D - K 477 - 724 F - J 521 - 200
K - F 476 - 724
flR10r ®�
IW,' S/� �i �- 15
�
oea4aaaialkpP
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installingand bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached r! id ceiling Locations shown forpermanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicabgle. Apply Oates to each face, of truss and position as shown above and on the Joint -Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the
truss in conformance with ANSI PI 1, or for handlin shipping, installation and bracing of.trussesA seal on this drawing or cover pa a .. 2400 Lake -Orange Dr.
listing this drawing indicates acceptance of pro) essfonar engineering responsibility solely for the design shown. The suitability g
and use of this drawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. Suite 150
For more information see this job's general notes page and these web sites: ALPINE: www.al ineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; [CC: www.iccsafe.org Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7012 / T16 / HIPS Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA14EAB ELEV.D Qly: 2 FROM: RWM DrwNo: 224.20.1548.1371
Truss Label: A3 SSB / DF 08/11/2020
7'10"14
7'10"14
0
W
t =4
�1 10
10.
Loading Criteria (psi)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 It
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N :T2, T4 2x4 SP 2400f-2.0E
Bot chord 2x4 SP #1 :B2, B3 2x4 SP 2400f-2.0E:
Webs 2x4 SP #2 N :W1, W6 2x4 SP #3:
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint
to be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be
supplied and attached at both ends to a suitable
support by erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2)
scabs for (2) CLR'S where shown. Scab
reinforcement to be same size, species, grade, and
80% length of web member. Attach with 0.128x3" gun
nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom
chord live load in areas with 42"-high x 24"-wide
clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
17' 218" 30'9"2
4'8" 9' 1 "2
=5X5 =5X5
D E
9'4„
19'4"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NF
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th.ed 201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
38'8"
9'4"
28'8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.182 J 999 360
VERT(TL): 0.436 J 999 240
HORZ(LL): 0.068 1 - -
HORZ(TL): 0.116 1
Creep Factor: 2.0
Max TC CSI: 0.760
Max BC CSI: 0.836
Max Web CSI: 0.629
VIEW Ver: 17.02.01A.1115.21
�,o i1IQIIIIIF,?P®
*S� �A" WA A �I;"0'
SAA I
gym, s �./-yp^� (�`'/jOr
o ��
0.
0 � �
0
STATE OF
v 0 A mot/ y°o
38'8"
7'10"14
in
m
10, 1'
38'8"r
A Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 1714 / 308 / 940 / - / 385 18.0
G 1715 /308 /940 /- /- /8.0
Wind reactions based on MWFRS
B Min Brg Width Req = 2.0
G Min Brg Width Req = 2.0
Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - C 1481 - 3117 E - F 1509 - 2925
C - D 1509 - 2923 F - G 1481 - 3119
D - E 1157 - 2043
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - K 2715 -1174 J - 1 1978 - 720
K - J 1978 - 692 1 - G 2717 -1204
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - K 404 -443 J - E 386 -244
K - D 834 - 463 E - 1 837 - 463
D - J 386 - 244 1 - F 404 - 443
s�,reis,OONAjoilliki1 ,�p0
FL 'REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricatingq handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary.
BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly
i!d ceilin Locations shown for ermanent lateral restraint of webs shall have bracinginstalled per BCSI sections 63, B7 or 810,
I e.-_ Apply plates to each face. otptruss and position as shown above and on the JoinfDetails, unless noted otherwise. f7efer to
of
n this drawing,any failure to build the
al on this drawing or cover pa e
*the design shown. The suitability
31/TPI 1 Sec.2.
SBCA: www.sbcindustry.com; ICC: www.iccsaf
ALPINE
AN —COMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
r I Hi 1, or Tor nanounqq,, snlppir
acceptance of ro7essionz
any structure is tphe respons
more information see this
Job Number: N333986
Ply: 1
$EQN: 7013 / T15 / HIPS
Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D
Qty: 2
FROM: RWM
DrwNo: 224.20.1548.12461
Truss Label: A4
KM it DF 08/1112020
7'10"14
15' 23'8" 30'9"2 38'8"
i 7,10"14
7'1"2 8'8" T1"2 7-10"14 i
5X5 = 5X5
D T3 E
12
6 �C5
F NS
0
i7
W 20
W1
B
G
A
H
a^5
4X6(A2) =6X6
82 =6X6 83 =6X6=4X6(A2)
38'8"
10'
9'4" 9'4" 10, 1'�
�1'
10'
19'4" 28'8" 38'8"
Loading Criteria (psf) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W
TCDL: 7.00 Speed: 160 mph
Pf: NA Ce: NA VERT(LL): 0.194 J 999 360 B 1691 1319 / 938 / - / 345 / 8.0
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.470 J 999 240 G 1692 / 319 / 938 / - / - / 8.0
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.067 1 - - Wind reactions based on MWFRS
Des Ld: 37.00 EXP: C
HORZ(TL): 0.115 I - - B Min Brg Width Req = 2.0
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf
G Min Br Width
Code / Misc Criteria Creep Factor: 2.0 g Re q = 2.0
Soffit: 0.00 BCDL: 5.0 psf
Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.937 Bearings B & G are a rigid surface.
Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.841 Bearings B & G require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft
Rep Factors Used: Yes Max Web CSI: 0.582 Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18
Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60
WAVE VIEW Ver: 17.02.01A.1115.21
Lumber
B - C 1496 -3045 E - F 1517 -2855
C - D 1517 - 2853 F - G 1496 - 3046
Value Set: 13B (Effective 6/1/2013)
D - E 1236 -2198
Top chord 2x4 SP #2 N :T3 2x4 SP #1:
Bot chord 2x4 SP #1 :132, B3 2x4 SP 2400f-2.OE:
Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #2 N :W1, W6 2x4 SP #3:
Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
B - K 2643 -1183 J - 1 2082 - 848
K - J 2082 - 819 1 - G 2645 -1213
Loading
Truss passed check for 20 psf additional bottom
i♦a 8f P P P; Maximum Web Forces Per Ply (Ibs)
chord live load in areas with 42"-high x 24"-wide
%®`Ii `r- Webs Tens.Comp. Webs Tens. Comp.
clearance.
r ® iWA,
N p�
`
Wind
�``� �000pi06a i P K-D 709 -369 E - 1 712 -369
o
EN, a0 ®�
Wind loads based on MWFRS with additional C&C
�e®� �
member design.
® No, 86367 a
r
o s
va STATE OF a
0/0�8�e
FL REG# 278, Yoonhwak Kim, FL PE 486367
08/11/2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING
TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin
Component Safety Information, by TPI
shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingq and bottom chord shall have a propperly
id
attached ri ceilin Locations shown for ermanent
as applicabgle. Applgy plates to each face ofptruss and
lateral restraint of webs shall have bracin irislalled per BCSI sections B3, 87 or B10,
as shown above the Joint9Details, Refer to
drawings 160A-Z for standard plate positions.
position and on unless noted otherwise.
ALPINE�
Alpine, a division of ITW Buildin Components Group
truss in conformance with ANS11 PI 1, or for handlingq''
Inc. shall not be responsible for any deviation from this drawing,apy failure to build the AN RW COMPANY
shippingp, installation bracing this drawing
listing this drawin� indicates acceptance of
this yawing for
and of.trussesA seal on or cover paqe.. 240o Lake Orange Dr.
engmeerm responsibility solely for the design shown. The suifablli y 9
guilding Suite 150
and use of the
any structure is he responsibility of the Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www:tpinst.org; SBCA: www.sbcindustry.com_ICC: www.iccsafe.org Orlando FL, 32837
Job Number: N333986
Ply: 1
SEQN: 7014 / T14 / HIPS
Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA14EAB ELEV.D i
Qly: 2
FROM: RWM
DrwNo: 224.20.1548.13709
Truss Label: A5
KIM / DF 08/11/2020
i 6'9"4 } 13' 1 19'4" 25'8 31"0"12 38'8"
'i` � �
6'9"4 6'2"12 6'4" 6'4" 62"12 6'9"4
5X5 III2X4 = 5X5
D E F
12
6 2X4
C
N
L2X4
_
io W3r`
Z
B H
A
q••3 I
4X6(A2) = 6X6 = 5X8 = 6X6 =4X6 (A2)
38'8"
1' 10, 9'4" 9'4" 10, 1'
f' +'
10, 19'4" i 28'8" 38'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (P9,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/# Loc R / U / Rw / Rh / RL / W
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.220 E 999 360 B 1665 / 699 / 931 / - 1304 / 8.0
BCLL: 0.00 Enclosure: Closed Lu:, NA Cs: NA VERT(TL): 0.543 E 999 240 H 1665 / 699 / 931 / - / - / 8.0
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.075 J - - Wind reactions based on MWFRS
EXP: C
Des Ld: 37.00 HORZ(TL): 0.130 J B Min Brg Width Req = 2.0
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 H Min Br g Width Reg = 2.0
Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.505 Bearings B & H are a rigid surface.
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.889 Bearings B & H require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Factors Used: Yes Max Web CSI: 0.355 Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.1115.21
Lumber B - C 1565 -3029 E - F 1432 -2498
C - D 1493 - 2774 F - G 1492 - 2775
Value Set: 13B (Effective 6/1/2013) D - E 1432 -2498 G - H 1564 - 3031
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "'I 3B" uses design values
approved 1 /30/2013 by ALSC B - L 2641 -1259 K - J 2171 - 956
L - K 2171 - 926 J - H 2642 -1289
Loading
Truss passed check for 20 psf additional bottom ;�f19 @0 i il�� Maximum Web Forces Per Ply (Ibs)
in 42"-high 24"-wide ,/
lload areas with x
p, Webs Tens.Comp. Webs Tens. Comp.
cchord learance. q�gOA1�A114WAk
�`� Q \a`®e ^®rh ©rIrl 6., L - D 572 -256 K - F 470 -224
Wind '�
i A y D - K 470 -224 F - J 573 -256
es* �
�`��' �
Wind loads based on MWFRS with additional C&C a"' 0 �` ® ,
e
member design. No 863 6 7
i
A ® e
0 STAFF OFF ®Cciti
NAL.
`�p1
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to -and follow the latest edition of BCSI (Building
Component Safety Information,
by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracinccll installed per BCSI sections B3, B7 or B10,
as applicabgle. Apply Oates to each face oftrussand position as shown above and -on the Joint Details, unless noted otherwise. Refer to
drawings 160A-Z for standard plate positions.
ALPINE
Alpine, a division of ITW Build ip/$c�Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the *N WCOMPANY
truss in ANSI
conformance with 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page2400 Lake Oran a Dr.
listing this drawing indicates acceptance of pro) esslonar engineering responsibility solely for the design shown. The suitability g
and use of this yawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. Suite 150
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ]CC: www.iccsafe.org Orlando FL, 32837
Job Number: N333986
Ply: 1
SEQN: 7015 / T12 / HIPS
Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D ;q
Qty: 1
FROM: RWM
DrwNo: 224.20.1548.17859
Truss Label: A6
JB / WHK 08/11/2020
5'9"4 11' 19' 27'8" 32'10"12 38'8"
5'9"4 5'2"12 8' 8'8" 5-2"12 5'9"4
5X5 = 5X5 = 5X5
D E T3 F
T 12
6 � �2X4 W 2X4
fo C G
n W3
toB
H
K J
4X6(A2) L = 5X5 = 5X8 = 5X5 = 4X6(A2)
38'8"
1' I 10, 9'4" 9'4" 10, 1'
10, �r 19,4" } 28'8„ 38,8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in. PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.203 E 999 360 B 1518 / 701 / 918 / - / 263 / 8.0
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.554 E 999 240 H 1518 / 701 1918 / - / - / 8.0
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 J - - Wind reactions based on MWFRS
Des Ld: 37.00 EXP: C HORZ(TL): 0.120 J - - B Min Brg Width Req = 1.8
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 H Min Brg Width Req = 1.8
Soffit: 0.00 Bldg Code: FBC 6th ed.201 Max TC CSI: 0.774 Bearings B & H are a rigid surface.
BCDL: 5.psf
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.832 Bearings B & H require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Factors Used: Yes Max Web CSI: 0.760 Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21
Lumber B - C 1616 -2720 E - F 1654 -2573
C - D 1496 - 2450 F - G 1498 - 2452
Value Set: 13B (Effective 6/1/2013) D - E 1677 -2603 G - H 1613 -2718
Top chord 2x4 SP #2 N :T3 2x4 SP #1:
Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3 :W3, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "1313" uses design values
approved 1 /30/2013 by ALSC B - L 2374 -1314 K - J 2081 -1082
L - K 2074 -1047 J - H 2371 -1341
Wind
Wind loads based on MWFRS with additional C&C 91I�119�Yt (1��Isp� Maximum Web Forces Per Ply (Ibs)
�PIIP
Webs Tens.Comp. Webs Tens. Comp.
member design. 11M%A�
�1 �t;0���
4 F-J 461 -156
E-K 388 -49
a N0. 86367 m
� s
�
a
8 eeo
®� STATE OF a
0R 1D)
If4dId4d9lfla0►t6
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information,
by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a propperly
attached ri id ceiling Locations shown forfpermanent lateral restraint of webs shall have bracingq insTalled per BCSI sections B3, B7 or 610,
as applicabgle. Apply plates to each face. o truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to
drawings 160A-Z for standard plate positions. ALPINE
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN mN COMPANY
truss in
conformance with ANSIl� PI 1, or for handling, shipping, installation and bracing of,trussesA seal on this drawing or cover pa e . , 240o Lake Orange Dr.
listing this drawingq indicates acceptance of -pro essiona engineering responsibility solely for the design shown. The suit9ability 9
and of this drawing for any structure is fhe responsibility of the Building Designer ANSI/TPI 1 Sec.2. Suite 150
,use per
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: w Apinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Orlando FL, 32837
SEQN:3855/ HIPS
Ply: 1
Job Number: N333986
Gust: R8975 JRef: 1 WXQ89750106 T9 /
FROM: RWM
Qty: 1
7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D
DrwNo: 224.20.1548.23911
Truss Label: A7
/ YK 08/11/2020
9' 28'8..
9' 8' 4'8" 8' 9'
6X6 -5X5 -4X4 =6X6
C T2 D E T3 F
12
6
T
W
o (a) (a) n
W5
rn
B G
A H I8,8„
q_3
4X6(A2) -6X6 =5X5 =6X6=4X6(A2) 1
38'8"
10' i 9'4" 9'4" 10,
10' 19'4" 28'8" 38'8"
Loading. Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) I Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.229 J 999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.427 J 999 240 B 1518 /- /- /900 R03 /222
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.075 1 - - G 1518 /- /- /900 /703 /-
EXP: C Kzt: NA
Des Ld: 37.00 HORZ(TL): 0.140 1 Wind reactions based on MWFRS
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf Code / Misc Criteria Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8
G Br Width = 8.0 Min Re 1.8
Soffit: 0.00 Bldg Cade: FBC 6th.ed 201 Max TC CSI: 0.906 g q =
BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.854 Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: Yes Max Web CSI: 0.280
Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 18.02.01A.0205.19
Lumber B - C 1545 -2622 E - F 1557 -2395
C - D 1558 - 2395 F - G 1545 - 2621
Value Set: 13B (Effective 6/1/2013) D - E 1915 -3079
Top chord 2x4 SP #1 :T2, T3 2x4 SP #2 N:
Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3 :W2, W5 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC B - K 2256 -1202 J - 1 3036 -1647
K - J 3034 -1648 I - G 2256 -1231
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint �4a�11 E111o►�jD� Maximum Web Forces Per Ply (Ibs)
to be equally spaced. Attach with (2) 8d Box or Gun t l A�
material to be Ps Webs Tens.Comp. Webs Tens. Comp.
. RestraintCo
.5a
suppled and lied b both ends to suitable mgq,,a
687289 E 7 5
support by erection contractor. '®.off
��°j ®�1y►YS�� K-D 483 -763 1 - F 688 -290
(a) or scab reinforcement may be used in lieu of CLR ue • P
restraint. substitute (1) scab for (1) CLR and (2) ® g° . N®. �6�67 m
scabs for (2) CLR'S where shown. Scab ft +p
reinforcement to be same size, species, grade, and ® s
80% length of web member. Attach with 0.128x3" gun
nails @ 6" oc. �, b
STATE OF w` Wind a
�' -
g
Wind loads based on MWFRS with additional C&C �e�0X% ae l�J
member design. ��� 0 p`
®�®A4/��1`(A8
p��
Additional Notes
(��
Refer to General Notes for additional information of +
FL REG# 278, Yoonhwak Kim, FL PE 986367
08/11/2020
**WARNING"* READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for saTpety to these functions. Installers
practices prior performing shall provide temporary
bracing per BCSI Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling.Locations shown for _permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 910,
as applicable. Applplates to each face otruss and position as shown above and on the Join Details, unless noted otherwise. Defer to
drawings 16DA-Z for standard plate positions.
ALPINE
Alpine, a division of ITW Building Components Group Inc.. shall not be responsible for any deviation from this drawing,any failure to build the AN RW COMPANY
truss in
conformance with ANSI/TPI 1, or for handli4 shipping, installation and bracing of.trussesA seal on this drawing or cover page , , 675o Forum Drive
Misting this drawing indicates acceptance of pro) essionar engineering responsibility solely for the design shown. The su,Pablhty
and use of this yawing for any structure is the responsibility the Designer ANSI/TPI 1 Sec.2. Suite 305
of uilding per
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com' TPI: www.tpinst.or ; SBCA: www sbcindustry.com; ICC: www.iccsafe.org' Orlando FL, 32821
Job Number: N333986
Ply: 1
SEQN: 7017 /
T25 / HIPS
Cusl: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 116721ARIA14EAB ELEV.D
Qty: 1
FROM: HMT
DrwNo: 224.20.1548.17936
Truss Label: A10G
JB P WHK 08/11/2020
T
17' 26'4" I
31'8" 38'8"
f 7
10 9�4" i
54 7 i
1116X8
=8X10 =H1014
=6X6
12 C
T2 D T3 E
T4 F
T 6�
T
ro
o
(a)
7(a)
B
A
G `*
H
as
N.
4X6(A2) B1 1112X4
=5X5 1112X4 =6X8 III5X5J
=5X5 =3X6(A1)
26'4"
12'4"
7112 4'10"4
5' 5'8" 3'8"
5'0"8 7'3"8 1'�
771"12 12'
17 22'8" 26'4"
31'4"8 38'8"
Loading Criteria (psi) Wind Criteria
Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10
Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U#
Loc R / U / Rw / Rh / RL / W
TCDL: 7.00 Speed: 160 mph
Pf: NA Ce: NA VERT(LL): 0.147 M 999 360
B 1751 / 806 / - / - / - / 8.0
BCLL: 0.00 Enclosure: Closed
Lu: NA Cs: NA VERT(TL): 0.409 M 999 240
J 4100 / 1843 / - / - / - / 8.0
BCDL: 10.00 Risk Category: II
Snow Duration: NA HORZ(LL): 0.053 K - -
G 256 / 134 / - / - / - / 8.0
Des Ld: 37.00 EXP: CMean
HORZ(TL): 0.101 K - -
Wind reactions based on MWFRS
Height: 15.00 ft
NCBCLL: 0.00 TCDL: 4.2 psf
Code / Misc Criteria Creep Factor: 2.0
B Min Brg Width Req = 2.1
Soffit: 0.00 BCDL: 5.0 psf
Bldg Code: FBC 6th ed.201 Max TC CSI: 0.896
J Min Br Width Re 5.7
g q -
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014 Max BC CSI: 0.984
G Min Brg Width Req = 1.5
Bearings B, J. & G are a rigid surface.Bearings
Spacing: 24.0 " C&C Dist a: 3.87 ft
Rep Factors Used: No Max Web CSI: 0.870
B, J, & G require a seat plate.
Loc. from endwall: NA
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Members not listed have forces less than 375#
Wind Duration: 1.60
WAVE, HS VIEW Ver: 17.02.02A.1213.21
Maximum Top Chord Forces Per Ply (Ibs)
Lumber
Chords Tens.Comp. Chords Tens. Comp.
Value Set: 13B (Effective 6/1/2013)
B - C 1493 -3260 C - D 1247 -3005
Top chord 2x4 SP #2 N :T2, T3 2x6 SP SS:
:T4 2x6 SP #2 N:
Maximum Bot Chord Forces Per Ply (Ibs)
Bot chord 2x4 SP #2 N :B1 2x4 SP #1:
Webs 2x4 SP #3 :W6 2x4 SP #2 N:
Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "13B" uses design values
B - N 2859 -1288 L - K 2810 -1334
approved 1/30/2013 by ALSC
N - M 2884 -1292 K - J 791 -1817
M-L 2810 -1334 J - 1 791 -1817
Bracing
d,3i1iVf1IP!!I/
(a) 1X4 #3SRB or better continuous lateral restraint
y t f l/j�
Maximum Web Forces Per Ply (Ibs)
to be equally spaced. Attach with (2) 8d Box or Gun
®�4i
N S" t�t►°Y l� k. 14,
Webs Tens.Comp. Webs Tens. Comp.
to be�*'�
attached at ends to alsluitable
dby
Fp--A,
®®
1938
��G�S�� �
3872
wi
support re ton contrabotoh
�r.�
D - K 1617 -3100 E - I
(a) or scab reinforcement may be used in lieu of CLR
pG
R t�l8
K - E 2681 -1062 I - F 372 -487
restraint. substitute (1) scab for (1) CLR and (2)
�e
' Y V
0
scabs for (2) CLR'S where shown. Scab
reinforcement to be
w o
same size, species, grade, and
80% length of web member. Attach with 0.128x3" gun
` o
e
nails @ 6" oc.
4® STATE OF
Loading
#1 hip supports 7-0-0 jacks with no webs.
® 4,) {��etd
®®/ ®fi®j�LypORIt t
��
�6A�®Aa,I
Wind
Wind loads and reactions based on MWFRS.
t✓f Y f1 F-
1g�11Il9@���bb�
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING
TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety to these functions. Installers
practices prior performing shall provide
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall
attach eli rigid ceilingq 'Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections
temporary
have a properly
B3, B7 or B10,
as applicable. Apply plates to each face ofptruss and position as shown above and on the Joinf-Details, unless noted otherwise. f7efer to
drawings
160A-Z for standard plate positions.
ALPINE
Alpine, a division of ITW BuildinggComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure
truss in ANSI
to build the
conformance with 1, or for handlMQ, shippingg, installation and bracing of,trussesA seal on this drawing or cover pa e, , 2400 Lake Orange
listing this drawingq indicates ,acceptance of ro) esslonar engineering responsibility solely for the design shown. The suifablllty 9
and use of this drawing for any structure is the responsibility of the building Designer ANSI/TPI 1 Sec.2. Suite 150
per
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinsl.org; SBCA: www.sbcindusty.com; ICC: www.iccsafe.org Orlando FL, 32837
SEQN: 3853 /
FROM: RWM
SPEC I Ply: 1
Qty: 1
7'10"14
7'10"14
Job Number: N333986
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D
Truss Label: A8
13'10" 16'8" 21'4"
5'11"2 2-10"+ 4'8'.
^
=5X5
D
38'8"
Cust: R 8975 JRef:1 WXQB9750106 T11 /
DrwNo: 224.20.1548.23974
)' YK 08/11/2020
27'8" 32'6"2 I 38'8"
6'4" 4'10"2 61"l4
9'4" 9'4" 10, 1'
10, 19,4„ 28,8„ i 38,8„ i °
Loading Criteria (ps0
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
D
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #1
Webs 2x4 SP #3 :W3, W6 2x4 SP #2 N:
Lumber value set "136" uses design values
approved 1/30/2013 by ALSC
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint
to be equally spaced. Attach with (2) 8d Box or Gun
nails(0.11 Yx2.5",min.). Restraint material to be
supplied and attached at both ends to a suitable
support by erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2)
scabs for (2) CLR'S where shown. Scab
reinforcement to be same size, species, grade, and
80% length of web member. Attach with 0.128x3" gun
nails @ 6" oc.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Refer to General Notes for additional information
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl L/#
Pf: NA Ce: NA
VERT(LL): 0.220 L 999 360
Lu: NA Cs: NA
VERT(CL): 0.410 L 999 240
Snow Duration: NA
HORZ(LL): 0.068 K - -
HORZ(TL): 0.127 K
Code / Misc Criteria
Creep Factor: 2.0
Bldg Code: FBC 6th.ed 201
Max TC CSI: 0.881
TPI Std: 2014
Max BC CSI: 0.859
Rep Fac: No
Max Web CSI: 0.647
FT/RT:20(0)/l 0(0)
Plate Type(s):
VIEW Ver: 18.02.01A.0205.19
WAVE
a o s
No. 86367
��� m• FATE 4F�����
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 1515 /- /- /921 /695 /321
1 1518 /- /- /916 /698 !-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
I Brg Width = 8.0 Min Req = 1.8
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1585 - 2648 F - G 1366 -1995
C - D 1601 - 2456 G - H 1527 - 2444
D - E 1064 -1492 H - 1 1629 - 2706
E - F 1655 - 2513
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - M 2290 -1231 L - K 2498 -1346
M - L 2446 -1305 K - I 2358 -1351
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
M - D 1664 -1070 F - K 431 - 632
M - E 1019 -1466 G - K 768 - 424
rf `lON ,A � b
�+/fldi8911C
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI an fabricating,
fsa ety practices prior to performing these functions. Installers shall provide temporary
BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a pro pperly
Id ceilingg Locations shown forpermanent lateral restraint of webs shall have bracingg ins �ailed per BCSI sections B3, B7 or 810.
e._ AppTy plates to each face. of truss and position as shown above and on the Joint -Details, unless noted otherwise. Defer to
of
Im 1, or Tor
acceptance
any structure
failure to build the
1 or cover pa e . .
n. The suit9abdtty
ALPINE
ANR COMPANY
6750 Forum Drive
Suite 305
Orlando FL, 32821
more information see
TPI: www.tpinst.org; SBCA:
Job Number: N333986
Ply: 1
SEQN: 7019 / T21 / SPEC
Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D
Qly: 1
FROM: RWM
DrwNo: 224.20.1548.18155
Truss Label: A9
JB f WHK 08/11/2020
7'10"14 13'10" 18'8" 24'8" 29'8" 38'8"
f 7'10"14 + 5'11"2 410 r 6' + 5' 9'
6X6
D
12 �6E6 =4F4 �5XC 6
6 5X5
C
(a)
M
W3 TS o
v
B H
A I
�
4X6(A2) = 5X5 = 8X8 = 6X6 = 3X6(A 1)
38'8"
10' 9'4" 9'4" 10,
�1'� +1'�
+ + +
10' 19'4" 28'8" 38'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ___ ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.292 E 999 360 g 1514 / 694 / 909 / - / 321 / 8.0
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.797 E 846 240 H 1516 / 697 / 903 / - / - / 8.0
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.073 D - - Wind reactions based on MWFRS
Des Ld: 37.00 EXP: C HORZ(TL): 0.137 D - - B Min Brg Width Req = 1.8
Mean Height: 15.00 ft Code / Misc Criteria CreepFactor: 2.0 H Min Brg Width Req = 1.8
NCBCLL: 10.00 TCDL: 4.2 psf
Bearings B & H are a rigid surface.
Soffit: 0.00 BCDL: 5.0 psf Bldg Code: FBC 6th ed.201 Max TC CSI: 0.879 9 9
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.905 Bearings B & H require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Factors Used: Yes Max Web CSI: 0.845 Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21
Lumber B - C 1600 -2648 E - F 2002 -3069
C - D 1620 - 2461 F - G 1581 - 2379
Value Set: 13B (Effective 6/1/2013) D - E 2555 -3805 G - H 1563 -2600
Top chord 2x4 SP #2 N :T5 2x4 SP 2400f-2,OE:
Bot chord 2x4 SP #1 Maximum Bot Chord Forces Per Ply (Ibs)
Webs 2x4 SP #3 :W3 2x4 SP #2 N: Chords Tens.Comp. Chords Tens. Comp.
Lumber value set "'I 3B" uses design values
approved 1/30/2013 by ALSC B - L 2290 -1231 K - J 2821 -1584
L - K 1836 - 912 J - H 2232 -1244
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint Maximum Web Forces Per Ply (Ibs)
to be Attach 8d Box Gun i1�IFf1li►
equally spaced. with (2) or Webs Tens.Comp. Webs Tens. Comp.
Restraint to be �1 n
suppled and attached).
att both ends to al sluitab a �0 a �0 L - D 598 -345 F - J 467 665
e•
• support by erection contractor.e'tl/f� PA D - K 2451 -1647 J - G 727 - 376
Gf 1f S`
(a) or scab reinforcement may be used in lieu of CLR ,4a� • �� *r eP E - K 1411 -1982
restraint. substitute (1) scab for (1) CLR and (2) �4 • e a+
scabs for CLR'S Scab ♦ Nii. 86367
(2) where shown. a
reinforcement to be same size, species, grade, and
80% length of web member. Attach with 0.128x3" gun 4 ® �� •
nails @ 6" oc.
Wind or e c STATE OF e 4/
Wind loads based on MWFRS with additional C&C v ® a a
member design.
C
bra
®P �`y �•OpQ® D
°d°eil�adao►tboe
FL
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11 /2020
**WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT*` FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI
and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly
attached ri id ceiling Locations shown for ermanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face ofptruss and position as shown above. and on the Joinf Details, unless noted otherwise. kefer to
drawings 160A-Z for standard plate positions. �LPP �I NN
ALPINE
Alpine, a division of ITW Buildin Components Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the —co...
truss in conformance with ANSI/ PI 1, or for handlin j shipping, Installation and bracing of,trussesA seal on this drawing or cover page , , 2400 Lake Orange Dr.
listing this drawing, indicates acceptance of pro) essiona engineering responsibility solely for the design shown. The suitability
this drawing for is the the Designer ANSI/TPI 1 Sec.2. Suite 150
and use of any structure responsibility of Building per
iFor more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Orlando FL, 32837
SEQN: 3838 / SPEC Ply: 1 Job Number: N333986 Cust: R 8975 JRef:1 WXQ89750106T4 /
FROM: HMT Qty: 1 , A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D DrwNo:. 224.20.1548.23896
Truss Label: All �TCE /"YK 08/11/2020
7'10"14
7'10"14
1310" I 20'8"
5'11"2 6-10"
5X5
D
26' 31'8" 38'8"
5'4" 5'8" 7'
21' j 5'
12'8" i
7'11"5 6'0"11 + 69"12 + 3'10"4 + 1'4+ 54"8 7,3"8 +1'�
7'11"5 14' 20'9"12 24'8" 26' 31'4"8 38'8"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
D
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N :T4 2x4 SP #1:
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 56 plf at -1.00 to
56 plf at 27.73
TC: From 28 plf at 27.73 to
28 plf at 31.67
TC: From 56 plf at 31.67 to
56 plf at 39.67
BC: From 20 plf at 0.00 to
20 plf at 27.73
BC: From 10 plf at 27.73 to
10 plf at 31.64
BC: From 20 plf at 31.64 to
20 plf at 38.67
TC: 174 lb Conc. Load at 27.73
TC: 161 lb Conc. Load at 29.60
TC: 87 lb Conc. Load at 31.60
TC: 288 lb Conc. Load at 31.64
BC: 128 lb Conc. Load at 27.73
BC: 125 lb Conc. Load at 29.60
BC: 489 lb Conc. Load at 31.64
Wind
Wind loads and reactions based on MWFRS.
Additional Notes
Refer to General Notes for additional information
Snow Criteria (Pg,Pfin PSF
Pg: NA Ct: NA CAT: N
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th.ed 201'
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Deft/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): 0.031 G 999 360
VERT(CL): 0.059 G 999 240
HORZ(LL): 0.013 0 - -
HORZ(TL): 0.024 0
Creep Factor: 2.0
Max TC CSI: 0.753
Max BC CSI: 0.886
Max Web CSI: 0.669
VIEW Ver: 18.02.01A.0205.19
��%J1110tIII IfIftle
B
® ` 9 �Po
¢ N0. 86367
em V
®� .a
STATE OF as �
T80
0
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 782 /- /-
/- /385 /-
M 1016 /- !-
/- /462 /-
K 1680 A /-
/- /795 /-
H 903 /- /-
/- /433 /-
Wind reactions based on MWFRS
B Brg Width = 8.0
Min Reg = 1.5
M Brg Width = 8.0
Min Req = 1.5
K Brg Width = 8.0
Min Req = 2.3
H Brg Width = 8.0
Min Req = 1.5
Bearings B, M, K, & H are a rigid surface.
Bearings B, M. K, & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
B - C 537 -1085
E - F 389 -166
C - D 279 - 542
F - G 509 -1166
D - E 285 - 546
G - H 664 -1396
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - 0 894 -414 J - H 1184 - 539
O - N 890 -415
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs Tens. Comp.
C - N
271 - 582
F - K 768 -1368
N - E
813 - 367
F - J 1757 - 789
E - M
518 - 875
J - G 377 - 244
��®� . ®1 OR ta� ���� C.
jaNAL ed,l�aa0��b�
FL REG# 278, Yoonhwak Kim, FL PE 486367
08/11/2020
- **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingand bottom chord shall have a prorp�erly
attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracingq insalled per BCSI sections B3, B7 or 910,
as applicable. Applgy plates to each face oftrussand position as shown above and on the Joint Details, unless noted otherwise. refer to ALPINE
,�
drawings 16OA-Z for standard plate positions. �LPPII NN
Alpine, a division of ITW Buildin,$cLComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the ANMCOWAW
truss in conformance with ANSI 1, or for handlin shipping, installation and bracing of,trussesA seal on this drawing or cover page, , 6750 Forum Drive
listing this drawin indicates acceptance -of pro esslona engmeerm responsibility solely for the design shown. The s. abuity
and use of this gnawing for any structure is fhe responsibility of the Ouilding Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see this job's general notes page and these web sites: ALPINE: www.alpincitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org Orlando FL, 32821
Job Number: N333986 Ply: 1 SEQN: 7021 / T29 / COMN Cust: R8975 JRef: 1WX089750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 3 FROM: RWM DrwNo: 224.20.1548.17702
Truss Label: B1 * x JB / WHK 08/11/2020
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
7'10"14 13'10" i 20'10"4 26'4"
7'10"14 5'11"2 - 7'0"4 5'5"12
T11"5
7.1i"5"5
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
21'
6'0"11
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NF
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bidg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
=4X4
D
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.034 J 999 360
VERT(TL): 0.095 J 999 240
HORZ(LL): 0.013 J - -
HORZ(TL): 0.024 J
Creep Factor: 2.0
Max TC CSI: 0.664
Max BC CSI: 0.664
Max Web CSI: 0.557
5'4"
5'4"
A Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 845 / 189 / 553 / - / 274 / 8.0
H 1051 / 193 / 550 / - / - / 8.0
K 185 /54 1116 /- /- /8.0
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
H Min Brg Width Req = 1.5
K Min Brg Width Req = 1.5
Bearings B, H, & K are a rigid surface.
Bearings B, H, & K require a seat plate.
Members not listed have forces less than 375#
VIEW Ver: 17.0102A.1213.21 Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
�Itj1114f11PlpP��'
L\C NSA, • ��
m .
t' No.86367
"' • o
4
�.� o• STATE OF ®tea
p 6 f1
B - C 643 -1221 D - E 482 - 694
C - D 483 - 679
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-J 1015 -501 J - 1 1011 -501
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - 1 394 - 579 E - H 517 - 903
1- E 586 -167
S +•.6d©
0NfIA ( 8+
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11 /2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
`"'IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro erly
attached rigid ceiling Locations shown forpermanent lateral restraint of webs shall have bracing; installed per BCSI sections B3, B7 or 910,
as applicable. Apply plates to each face of truss and position as shown above and on the Jcint"Details, unless noted otherwise. Refer to I�
drawings 160A-Z for standard plate positions. ALPINE
NN
Alpine, a division of ITW Build in Components Group Inc. shall not be responsible for any deviation from this drawing,apy failure to build the RNnW COMPANY
truss in conformance with ANSIl� PI 1, or for handling, shipping,_ installation and bracing of.trussesA seal on this drawing or cover pagge .. 2400 Lake Orange Dr.
listing this drawing indicates acceptance of pro esslona engineering responsibility solely for the design shown. The suitability
g
and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150
For more information see this job's general notes page and these web sites: ALPINE: www.alpine;tw.com; TPI: wwwjp nsl.org, MCA: www.sbcindusigxom; ICC: www.iccsafe.org Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7022 / T27 / GABL Cust: R8975 JRef: 1WX089750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DrwNo: 224.20.1548.17952
Truss Label: 82GE JB / WHK 08/11/2020
6'1'7 13'10" 27'8"
6'17 7'8"9 13'10"
r — 310 --}-- 4 —1 —�P�4X4 �
H
Loading Criteria (ps0
Wind Criteria _
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3
Lumber value set "l36" uses design values
approved 1/3012013 by ALSC
Plating Notes
All plates are 2X4 except as noted.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS A16015ENC101014 & GBLLETIN1014 for
gable wind bracing and other requirements.
Truss designed to support 8" maximum gable
end overhang.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Deft/CSI Criteria
PP Deflection in loc L/defl U#
VERT(LL): 0.021 O 999 360
VERT(TL): 0.064 0 999 240
HORZ(LL):-0.011 M - -
HORZ(TL): 0.020 M
Creep Factor: 2.0
Max TC CSI: 0.146
Max BC CSI: 0.284
Max Web CSI: 0.127
VIEW Ver: 17.02.02A.1213.21
twiIIIIIIpt POto
®NHW AA- r °°°
d
s+
No, 86367 a
0
a °� STATE OF
sP�"®S,S f ®o ® e °
♦Maximum Reactions (lbs), or•=PLF
Loc R / U / Rw / Rh / RL / W
B 209 / 77 / 110 / - / 290 / 8.0
B' 79 / 17 / 42 / - / - / 248
Z 256 /95 /210 /- /- /8.0
AA57 /21 /55 /- /- /16.0
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
B Min Brg Width Req = -
Z Min Brg Width Req = 1.5
AA Min Brg Width Req = 1.5
Bearings B, B, Z, & Z are a rigid surface.
Bearings B, B, Z, & Z require a seat plate.
Members not listed have forces less than 375#
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11 /2020
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly
attached ri id ceilin Locations shown fornermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10.
as applicable. Applgji plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to ALPINE
drawings 160A-Z for standard plate positions.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN ITNCOMPANY
truss in conformance with ANSII�PI 1, or for handling, shipping, installation and bracing of,trussesA seal on this drawing or cover pa e. , 2400 Lake Orange Dr.
listing this drawing, indicates acceptance of proTesstonar engineering responsibility solely for the design shown. The suit9abillty g
and use of this drawing for any structure is he responsibility of the building Designer per ANSI/TPI 1 Sec.2. Suite 150
For more information see this job's general notes page and these web sites: ALPINE: www.alpineilw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com• ICC: www.iccsafe.org Orlando FL, 32837
Job Number: N333986 . Ply: 1 I SEQN: 7030 / T28 / GABL Cust: R8975 JRef: 1 WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DrwNo: 224.20.1548.17266
Truss Label: C1GE JB / WHK 08/11/2020
EO
in
N
43
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-10
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
EXP: C
Des Ld: 37.00 D
Des d:: .00 Mean Height: 15.00 ft
TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3
Lumber value set "1313" uses design values
approved 1/30/2013 byALSC
Plating Notes
All plates are 2X4 except as noted.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
See DWGS Al 6015ENC101 014 & GBLLETIN1014 for
gable wind bracing and other requirements.
+ MEMBER TO BE LATERALLY BRACED FOR
HORIZONTAL WIND LOADS. BRACING SYSTEM
TO BE DESIGNED AND FURNISHED BY OTHERS.
2'2" 1 4'2" 6'2" 8'4"
2'2" 1 2' 12' 12'2"
4X4
D
8'4"
2'2" 1 2' 2' 2'2" 1'
2�2� 4-2� T 6�2" 1 84
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th.ed
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.0031 999 360
VERT(TL): 0.0081 999 240
HORZ(LL): 0.001 H - -
HORZ(TL): 0.003 H
Creep Factor: 2.0
Max TC CSI: 0.223
Max BC CSI: 0.095
Max Web CSI: 0.086
VIEW Ver: 17.02.01A.1115.21
0 Maximum Reactions (lbs), or *=PLF
Loc R /U /Rw /Rh /RL /W
B* 185 / 87 / 135 / - / 59 / 24.0
F* 185 / 87 / 135 / - / - / 24.0
Wind reactions based on MWFRS
B Min Brg Width Req = -
F Min Brg Width Req = -
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
III Itrprito,
cE Ns
a
N0, 86367
.a
a e .'moo
a ®& STATE OF a 4,c,v
a�
I p�,IZQ
" e • p � 0 ®
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI an�'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
r SCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a properly
�id ceilin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10
le. Applgy plates to each face ofPtruss and position as shown above and on the Join f Details, unless noted otherwise. kefer to'
60A-Z for standard plate positions.
Alpine, a division of ITW Buildin Cc
truss in conformance with ANSIl� PI
listing this drawing,indicates aca
and use of this awing for any
C
his drawing,an , failure to build the
on this drawing or cover page
ie design shown. The suifability
TPI 1 Sec. 2.
CA: www.sbcindLtstry.com; ICC: www.iccsaf
ALPINE
AN CRY COMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
and these web
SEQN: 3845/ VAL Ply: 1 Job Number: N333986 Cust: R8975 JRef:1WXQ89750106T7 /
FROM: RWM Qty: 1 7A5/320 ,167ED ,RG01 / 1672/ARIAAEAB ELEV.D DrwNo: 224.20.1548.23897
Truss Label: V4 �TCE / YK 08/11/2020
Loading. Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
1'l1"8 3'11"
1'l 1 "8 1'11 "8
12
6 = 4X4
B
A 4X4(D1)=4X4(D1) C
14' 11 "3
D
i- 3'11" _I
3'11" i
i 3'11"
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.59 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCp!: 0.18
Wind Duration: 1.60
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "l3B" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Refer to General Notes for additional information
Valley truss connection to truss below shall be
designed and furnished by others .
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th.ed 201
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
DefI/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.004 999 360
VERT(CL): 0.007 999 240
HORZ(LL): -0.001 - -
HORZ(TL): 0.003
Creep Factor: 2.0
Max TC CSI: 0.070
Max BC CSI: 0.104
Max Web CSI: 0.000
VIEW Ver: 18.02.01A.0205.19
♦ Maximum Reactions (lbs), or `=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
D' 75 /- /- /31 /10 /6
Wind reactions based on MWFRS
D Brg Width = 47.0 Min Req = -
Bearing A is a rigid surface.
Members not listed have forces less than 375#
,1lsrta�I,ItiIt? ffp/p
NAQ A WA/�
J. d•
No. 86367 0
STATE OF
®A"aIS�ONA 1_
411111l11111
FL REG# 278, Yoonhwak Kim, FL PE 486367
08/ 11 /2020
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
n Components Group In . shall not be responsible for any deviation from this drawing,any failure to build the
illr} PI 1, or for handlin4, s�ippinq, installation and bracing of.trussesA seal on this drawing or cover pa e,
s acceptance of pro) essionar engineering responsibility solely for the design shown. The suifabillty
r any structure is the responsibility of the Building Desigrier per ANSI/TPI 1 Sec.2.
ALPINE
AN nW COMPANY
6750 Forum Drive
Suite 305
Orlando FL, 32821
ALPINE: www.alpineitwxom; TPI:
Job Number: N333986 Ply: 1 SEQN: 1031 / T5 / VAL Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D y. Qty: 1 FROM: RWM DrwNo: 224.20.1548.17579
Truss Label: MV01 JB / WHK 08/11/2020
�= 4
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-10
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
EXP: C
Des Ld: 37.00 Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3
Lumber value set "l3B" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Additional Notes
Valley truss connection to truss below shall be
designed and furnished by others . ,
1112X4
B
a1)
4'1"11 _1
4'1"11
4'1"11
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/l 0(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.003 C
HORZ(TL): 0.006 C
Creep Factor: 2.0
Max TC CSI: 0.222
Max BC CSI: 0.177
Max Web CSI: 0.100
VIEW Ver: 17.02.02A.1213.21
♦ Maximum Reactions (lbs), or "=PLF
Loc R I /Rw /Rh /RL /W
D' 75 /28 /52 /- /18 /49.7
Wind reactions based on MWFRS
D Min Brg Width Req = -
Bearing A is a rigid surface.
Members not listed have forces less than 375#
�A VVA
m t! ISO, 8636! f3
i
4 q
® MATE OFro
9� i10
R INA Ldifillikt
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
m Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the
�PI 1, or for handling shipping, Installation and bracing of,trussesA seal on this drawing or cover paqe . .
s acceptance of ro esslona engmeerin� responstbillty solely for the design ...The s.ifabtlfty
r any structure is he responsibility of the uilding Designer per ANSIITPI 1 Sec.2.
neral notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsaf
I
ALPINE',
ANmMCOMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7032 / T6 / VAL Gust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D i Qty: 1 FROM: RWM DrwNo:: 224.20.1548.18077
Truss Label: MV02 3 JB / WHK 08/11/2020
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-10
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 37Mea
.00 C
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: h to 2h
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Webs 2x4 SP #3
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Valley truss connection to truss below shall be
designed and furnished by others .
12
6 1112X4g
i 2' 1 "11 �{
2'1"11
2'1"11
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/l 0(0)
Plate Type(s):
WAVE
T
CV
Defl/CSI Criteria ♦ Maximum Reactions (lbs), or *=PLF
PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.000 C
HORZ(TL): 0.001 C
Creep Factor: 2.0
Max TC CSI: 0.039
Max BC CSI: 0.041
Max Web CSI: 0.026
VIEW Ver: 17.02.02A.1213.21
D* 75 113 / 48 /- / 10 / 25.7
Wind reactions based on MWFRS
D Min Brg Width Req = -
Bearing A is a rigid surface.
Members not listed have forces less than 375#
�®dgi\IQi9tllp���v
,'�`' p��W AA
w
i
a 00
G No.86367
STATE OF cv�
PONAL s
e4441e14ue
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro erly
attached ri id ceilin Locations shown forpermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 910, _
as applical5 e. AppTgy plates to each face oftrussand position as shown above and on the Join Details, unless noted otherwise. F�efer to ALPINE�
drawings 160A-Z for standard plate positions.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the AN—COWA-
truss in conformance with ANSIlgfPl-1, or for handlin4, shippintq, installation and bracing of,trussesA seal on this drawing or cover pagge, . 2400 Lake Orange Dr. -
listing this drawing, indicates acceptance of -pro) essiona engineering responsibility solely for the design shown. The suiTability and use of this drawing for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2. Suite 150
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org_ Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7033 / T8 / EJAC Cust: R8975 JRef: 1WX089750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 14 FROM: RWM DrwNo: 224.20.1548.13865
Truss Label: EJ7 JB /' WHK 08/11/2020
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set 1313" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
ad
more
Snow Criteria (Pg,PfinPSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
7-
T
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.017 D
HORZ(TL): 0.031 D
Creep Factor: 2.0
Max TC CSI: 0.713
Max BC CSI: 0.527
Max Web CSI: 0.000
VIEW Ver: 17.02.02A.1213.21
L
N
M
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 331 /117 /259 /- /173 /8.0
D 127 /20 /101 /- /- /1.5
C 171 /133 /91 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
C Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
®,ojjIjIIf IIIP rPr
��agm@AH� .p/Ak
o '� (� • r
© 0 ,.
a
STATE 4F
ORID�Q'
�ONAk.
d�oAdf-0IksJ1�6®��
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Safety Information, by TPI and SBCA) fsafety practices prior to performing these functions. Installers shall provide temporary
r BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly
aid ceiling. Locations shown for ermanent lateral restraint of webs shall have bracinnn installed per BCSI sections B3, B7 or B10,
ale. A .plgy plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. kefer to
60A-Z for standard plate positions.
q Components Group Inc.. shall not be responsible for any deviation from this drawing,any failure to build the
TPI 1, or for handling, shlppinq, installation and bracing oftrussesA seal on this drawing or cover pafge
acceptance of pro esslona engineering responsibility solely for the design shown. The sui ability
any structure is he responsibility of the uilding Designer per ANSI/TPI 1 Sec.2.
ral notes page and these web sites: ALPINE. www.alp.ineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsaf
ALPINE
ANMCOMPAW
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7034 / T3 / EJAC Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 2 FROM: RWM DrwNo: 224.20.1548.17858
Truss Label: EJ7A JB / WHK 08/11/2020
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
- 2'4"
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
7'
7'
Defl/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.012 D
HORZ(TL): 0.021 D
Creep Factor: 2.0
Max TC CSI: 0.775
Max BC CSI: 0.504
Max Web CSI: 0.000
VIEW Ver: 17.02.02A.1213.21
l��Rt,wa��rRrnrr►��P
ea
No. 86367
® a
STATE 4F e�
C
co
O
(�7
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 425 / 178 / 370 / - 1202 / 8.0
D 125 /12 /101 /- /- /1.5
C 161 /125 /78 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
C Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
114440
/0 a '
FL REG# 278, Yoonhwak Kim, FL PE 486367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a properly
id ceilin Locations shown for_permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10.
e. Applgj plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. Defer to
60A-Z for standard plate positions.
a division of
rIm 1,orfor h
acceptance
any structure
these web sites: ALPINE:
from this drawing,anV failure to build the
k seal on this drawl vg or cover pa e ,
I for the de Sec shown. The suit9abillty
ALPINE
AN—COWAW
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7035 / T1 / EJAC Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RWM DnwNo: 224.20.1548.17749
Truss Label: EJ7S KM / WHK 08/11/2020
T
rA
B
M
O
M
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): NA A 270 / 79 / 188 / - / 151 / 8.0
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): NA C 128 / 21 / 104 / - / - / 1.5
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.018 C B 174 / 135 / 95 / - / - / 1.5
Des Ld: 37.00 EXP: Cgh15.00 ft HORZ(TL): 0.033 C - - Wind reactions based on MWFRS
Mean Height: NCBCLL: 10.00 TCDL: ei t: Code / Misc Criteria Creep Factor: 2.0 A Min Brg Width Req = 1.5
Soffit: 0.00 p Bldg Code: FBC 6th.ed 201 Max TC CSI: 0.725 C Min Brg Width Req = -
BCDL: 5.0 psf B Min Brg Width Req = -
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.533
Bearing A is a rigid surface.
Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.000 Bearing A requires a seat plate.
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0)
GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375#
Wind Duration: 1.60 WAVE VIEW Ver: 17.02.02A.1213.21
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes �01 H 1rYA
Provide (2) 0.131 "x3.0", min. toe -nails at top chord. �d� `®_eE Af� �0
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. ,[.
No. 8636�
0 STATE 4E
ORIV
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted othenwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperly
attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracingg insgalled per BCSI sections B3, B7 or B10,
as applicabgle. Applgy plates to each face of truss and position as shown above and on the JoinfiDetails, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. •
Alpine, a division of ITW BuildinqqComponents Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the AN wco�AH,.
truss in conformance with ANSVTPI 1, or for handlin4, shipping, Installation and bracing of,trussesA seal on this drawing or cover pa�e • , 2400 Lake Orange Dr.
listing this drawing,indicates acceptance of ro essiona engineerm responsibility solely for the design shown. The sui ability 9
and use of this awing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 150
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.icrsafe.org Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7023 / T2 / JACK Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 5 FROM: RDP DrwNo: 224.20.1548.13975
Truss Label: CJ5 KD / YK 08/11/2020
C
12
6
M
9
("I
M
B
3 A
D
1' Din 4'11"4 !
4' 11 "4
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Sid: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C
Des Ld: 37.00
Mean Height: 15.00 it
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 it
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "13B" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
more
Snow Criteria (Pg,Pfin PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.005 D
HORZ(TL): 0.010 D
Creep Factor: 2.0
Max TC CSI: 0.411
Max BC CSI: 0.254
Max Web CSI: 0.000
VIEW Ver: 17.02.01A.1115.21
`1,tjjj1111tiff fftp
se
.s
a
0
4 No.86367
p
a► p �� •
a 6 �
STATE 4F �~
♦ Maximum Reactions (lbs)
Loc R /U /Rw /Rh /RL /W
B 256 / 95 / 207 / - / 128 / 8.0
D 89 /13 /68 /- /- 11.5
C 118 /92 /61 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
C Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
toRtia�
0N�aL
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
"WARNING"` READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handlin shipping, installing.and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI an � SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary.
BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly
id ceiling Locations shown fornermanent lateral restraint of webs shall have bracingq installed per BCSI sections B3, B7 or B10.
60A_Zpe. Afop y plates to each face or truss and position as shown above and on the Join i Details, unless noted otherwise. kefer to
for standard plate positions.
a division of
I NI i, or for r
acceptance
any structure
any deviation from this drawing,any failure to build the
rig oftrussesA seal on this drawing or cover page
sibility solely for the design shown. The suifabillty
)esignerper ANSt/TPI 1 Sec.2.
TPI: www.tpinst.org; SBCA: www.sbcindustry_.com; ICC: www.iccsal
'Aakl.
ALPINE
Mn COMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 328'
Job Number: N333986 Ply: 1 SEQN: 7028 / T32 / JACK Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D City: 1 FROM: RDP DrwNo:. 224.20.1548.17562
Truss Label: CJ5A JB / WHK 08/11/2020
Loading Criteria (psi)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
A
12
6
`')
a�
(V
0)
B
F_
T
A = 2X4(A1)
D
�— 2'4" 4'11 "4
4' 11 "4
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C
Mean Height: 15.00 It
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "l3B" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.20
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.006 D
HORZ(TL): 0.008 D
Creep Factor: 2.0
Max TC CSI: 0.775
Max BC CSI: 0.245
Max Web CS 1: 0.000
VIEW Ver: 17.02.02A.1213.21
♦ Maximum Reactions (Ibs)
Loc R / U / Rw / Rh / RL / W
B 358 / 162 / 329 / - / 157 / 8.0
D 85 /13 /77 /- /- /1.5
C 102 /80 /41 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
C Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
�,`�1`OIIPttt1►����
Aft too,
AA
No. 8630 /
Q.
� � s
%� ; STATE OF ®w�
�rs0, 4 FzoRia�
��°06dido 1dA� e�
iijFL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
r BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a properly
aid ceiling Locations shown for permanent lateral restraint of webs shall have bracingp installed per BCSI sections B3, B7 or B10,
fle. AppTy plates to each face oftrussand position as shown above and on the Joint Details, unless noted otherwise. kefer to
60A-Z for standard plate positions.
of
rawing Tor any structure is the respon
this job's general notes page and these web sites:
failure to build the
1 or cover pa e ,
n. The sulPabtiity
ALPINE
AN RW C0WANN
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7024 / T22 / JACK Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIAMEAB ELEV.D Qty: 5 FROM: RDP DrwNo: 224.20.1548.12587
Truss Label: CJ3 JB / WHK 08/11/2020
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
V
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/112013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
2X4(A1)
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N/
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
C
ONE!
2'11'A '
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): 0.001 D
HORZ(TL): 0.0.01 D
Creep Factor: 2.0
Max TC CSI: 0.206
Max BC CSI: 0.115
Max Web CSI: 0.000
VIEW Ver: 17.02.01A.1115.21
i
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 185 / 75 1 160 / - / 84 / 8:0
D 50 /6 /41 /- /- /1.5
C 63 /50 /29 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
C Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
`�,�N�t111a►orrl
p�
CEfYS®«� p0f��
\
No, 86367
® d
q
STATE OF ° Cc/��
v
ee�tMO
FL REG# 278, Yoonhwak Kim, FL PE 486367
08/11 /2020
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT`* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
a division of
information see
in Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the
311�PI 1, or for handl!n� shippinq, installation and bracing of,trussesA seal on this drawing or cover pa e , .
s acceptance of pro essfonarr engineering responsibility solely for the design shown. The su Pabdlty
it any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
neral notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsaf
ALPINE
AN 710MVAN
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
Job Number: N333986 Ply: 1 SEQN: 7029 / T20 / JACK Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qty: 1 FROM: RDP DnvNo: 224.20.1548.18092
Truss Label: CJ3A ' . KID / YK 08/11/2020
IV
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
Des Ld: 37.00
EXP: C
Mean Height: 15.00 It
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #1
Bot chord 2x4 SP #2 N
Lumber value set "136"
uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131 "x3.0",
min. toe -nails at top chord.
Provide (2) 0.131"x3.0",
min. toe -nails at bottom chord.
2'4" 2' 11 "4
2' 11 "4
Snow Criteria (P9,Pf in PSF)
Pg: NA Ct: NA CAT: NF
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL): -0.003 D
HORZ(TL): 0.004 D
Creep Factor: 2.0
Max TC CSI: 0.908
Max BC CSI: 0.283
Max Web CSI: 0.000
VIEW Ver: 17.02.02A.1213.21
C
c'7
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 308 / 157 / 309 / - 1113 / 8.0
D 45 /24 /55 !- /- /1.5
C 34 /28 /35 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
G Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
`�j1110f11fl/�p�
NAH - AA-
4 4 No.86367
STATE OF ® 'i ,-
'9
��o S ••eQ®° e
ea®adS�QN+A� `�+®
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11 /2020
**WARNING"* READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing. and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r sa ety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperly
attached rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 910
as applicable. Apply Oates to each face oftrussand position as shown above and on the Joint9Details, unless noted otherwise. Refer to'
drawings 160A-Z for standard plate positions.
FiHi 1, or Tor
acceptance
any structure
from this drawing,any failure to build the
1 seal on this drawing or cover page ,
r for the design shovJn. The -suifablllty
ANSI/TPI 1 Sec.2.
AL NE
ANMCOMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
information see this
Icc:
Job Number: N333986 Ply: 1 SEQN: 7025 / T24 / JACK Cust: R8975 JRef: 1 WX089750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D 'r Qty: 6 FROM: RDP DrwNo: 224.20.1548.13974
Truss Label: CJ1 JB / WHK 08/11/2020
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
T
Wind Criteria
Wind Std: ASCE 7-10
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP #2 N
Lumber value set "136" uses design values
approved 1/30/2013 by ALSC
Wind
Wind loads based on MWFRS with additional C&C
member design.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
12
6 C
F
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: N!
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed.201
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
M T
M
co
11 "4
11 "4
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(TL): NA
HORZ(LL):-0.000 D
HORZ(TL): 0.000 D
Creep Factor: 2.0
Max TC CSI: 0.196
Max BC CSI: 0.025
Max Web CSI: 0.000
VIEW Ver: 17.02.01A.1115.21
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 143 /79 /148 /- /41 /8.0
D 11 /12 /18 /- /- 11.5
C -15 /32 /27 /- /- /1.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
D Min Brg Width Req = -
C Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
�y1i141/111lIq��
�QNHW Ak `'f
a �
s No. 86367 • o
F ^ r•m
o ® G r
Y
®� STATE flF
ds,ONBA16 �
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properly
t,Aceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10
,
pply plates to each face. of ttruss and position as shown above and on the Joint9Details, unless noted otherwise. kefer to
a division of
acceptance or protessionqi engineers
any structure is the responsibility of the
his drawing,any failure to build the
on this drawn vg or cover pa e
ie design shown. The suit9abdlty
1.
ALPINE
AN; COMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 328'
more information see
Job Number: N333986 Ply: 1 SEQN: 3843 / T19 / HIP_ Cust: R8975 JRef: 1WXQ89750106
,7A5/320 ,167ED ,RG01 / 1672/ARIA/4EAB ELEV.D Qly: 3 FROM: RWM DrwNo: 224.20.1548.13756
Truss Label: HJ7 TCE / WHK 08/11/2020
5'Y5 9110"1
5'Y5 4'6"l 1
T
4"3
i
�— 1'5"
Loading Criteria (psf).
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-10
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
Des Ld: 37.00
EXP: C
Mean Height: 15.00 ft
NCBCLL: 0.00
TCDL: 4.2 psf
Soffit: 0.00 .
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Value Set: 13B (Effective 6/1/2013)
Top chord 2x4 SP #2 N
Bot chord 2x4 SP 2400f-2.0E
Webs 2x4 SP #3
Lumber value set "1313" uses design values
approved 1/30/2013 by ALSC
Loading
Hipjack supports 6-11-8 setback jacks with no webs.
Wind
Wind loads and reactions based on MWFRS.
Provide (3) 0.162"x3.5", min toe -nails at top chord.
Provide (3) 0.162"x3.5", min toe -nails at bottom chord.
9'2"2
9'2"2
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NI
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Code / Misc Criteria
Bldg Code: FBC 6th ed
TPI Std: 2014
Rep Factors Used: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defi/CSI Criteria
PP Deflection in loc L/defl U#
VERT(LL): 0.040 F 999 360
VERT(TL): 0.111 F 999 240
HORZ(LL): 0.010 C - -
HORZ(TL): 0.018 C
Creep Factor: 2.0
Max TC CSI: 0.546
Max BC CSI: 0.416
Max Web CSI: 0.260
7.11
9'10'1
♦ Maximum Reactions (Ibs)
Loc R /U /Rw /Rh /RL /W
B 326 / 154 / - /- 1- / 10.6
E 364 /84 /- /0 /0 11.5
D 214 /177 /- /- /- 11.5
Wind reactions based on MWFRS
B Min Brg Width Req = 1.5
E Min Brg Width Req = -
D Min Brg Width Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
VIEW Ver: 17.02.01A.1115.21 Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - C 394 - 562
ati1f114f 11 Plfi�ll
� WAS10,
�'''�
m s No. 86367
r "�1 Pm STATE OF .(/
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - F 531 - 358
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - F 394 - 583
®d •ro®6Ae� pe, (�
�eiir�ieaour
FL REG# 278, Yoonhwak Kim, FL PE #86367
08/11/2020
"WARNING' READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
the latest edition of BCSI (Building
Installers shall provide temporary
bottom chord shall have a pro erly
per BCSI sections B3, B7 or 910,
unless noted otherwise. kefer to
of
r I vi 1, or Tor nanaing, snipplr
acceptance of rOTessioni
any structure is the respons
failure to build the
or cover pa e
n. The suit9ability
ALPINE
ANMCOMPANY
2400 Lake Orange Dr.
Suite 150
Orlando FL, 32837
more information see this
TPI: www.tpinst.org; SBCA:
Gable Stud Reinforcement Detail
ASCE 7-101 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00
Or, 140 Mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00
Ori 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00
❑ri 120 mnh Wind Sneed. 15' Mann Helnht. Pnrtinllv P-1—orl_ Fenn —a n ih+ = I nn
S
2x4 Brace
Gable Vertical
Spacing Species Grade
No
Braces
(1) lx4 'L' Brace w
(1) 2x4 'L' Brace w
(2) 2x4 'L' Brace ww
(1) 2x6 'L' Brace M
(2) 2x6 'L' Brace w
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
#1 #2
S P P
#3
3' 8'
5' 9'
6' 2'
7' 8'
i' 11'
9' 1.
9' 6'
12' 0'
12' 6'
14' 0'
14' 0'
l-
Stud
3' 8'
5' 9'
6' 1'
7' 8'
7' 11'
9' 1'
9' 6'
12, 0'
12' 6'
14' 0'
14' 0'
p
Standard
3' 8'
4' 11'
5' 3'
6' 7'
7' 1'
8' 11'
9' 6'
10' 4'
11' 1'
14' 0'
14' 0'
CU
#1
4' 0'
6' 8'
6' 11'
7' 10'
8' 2'
9' 4'
9' 8'
12' 4'
12' 9.'
14' 0'
14' 0'
J
S P
#2
3' 10,
6' 7'
6' 10,
7' 9'
8' 1'
9' 3'
9' 7'
12' 2'
12' 8'
14' 0'
14' 0'
#3
3' 9'
5' 3'
5' 7'
6' 11'
7' 5'
9' 2'
9' 7'
10, 11'
11' 8'
14' 0'
14' 0'
P
Stud
3' 9'
5' 3'
5' 7'
6' 11'
7' 5'
9' P.
9' 7'
10, 11'
11' 8'
14' 0'
14' 0'
d
Standard
3' 6'
4' 7'
4' 11'
6' 2'
6' 7'
8' 4'
8' 11'
9' 8
10' 4'
13' 1'
14' 0'
U
_
#1 / #2
4' 5'
7' 6'
7' 9'
8' 10'
9' 3'
10' 7'
11' 0'
13' Il'
14' 0'
14' 0'
14' 0'
_
S P P
#3
4' 2'
7' 1'
7' 9'
8' 9'
9' 1'
10' 5'
1 10' 10'
13, 9'
14' 0'
14' 0'
14' 0'
U
I_I
QJ
O
I�
Standard
4' 2'
6' 1'
G' 5'
8' 1'
8' 8'
10' 5'
10, 10,
12' 8'
13' 7'
14' 0'
14' 0'
\
#1
4' 7'
7' 7'
7' 11'
9' 0'
9' 4'
10, 8'
ill 1'
14' 0'
14' 0'
14' 0'
14' 0'
/
S P
#2
4' 5'
7' 6'
7' 9'
8' 10'
9' 3'
10' 7'
11' 0'
13' 11'
14' 0'
14' 0'
14' 0'
#3
4' 4'
6' 5'
6' 10'
8' 6'
9' 1'
10' 6'
10, 11'
13' 4'
14' 0'
14' 0'
14' 0'
QJ
D P L
Stud
4' 4'
6' 5'
6' 10'
8' 6'
9' 1'
10' 6'
10' 11'
13' 4'
14' 0
14' 0'
14' 0'
Standard
4' 2'
S' 8'
6' 0'
7' 6'
8' 0'
1 10' 2'
10, 10,
11' 10,
12' 7'
14' 0'
14' 0'
#1 / #2
4' 10'
8' 3'
8' 7'
9' 9'
10' 2'
10, 7'
12' 1'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P P
#3
4' 7'
8' 2'
8' 5'
9' 8'
10, 0'
11' 6'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
U
LIP
Stud
4' 7'
8 ' 2'
8' 5'
9' 8'
10, 0'
11' 6'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
O
I�l
Standard
4' 7'
7' 0'
7' 5'
9' 4'
10, 0'
11' 6'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
X
#1
5' 1'
8' 5'
8' 8'
9' 11'
10' 3'
11, 9'
12, 3'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 10'
8' 3'
8' 7'
9' 9'
10, 2'
11' 7'
12' 1'
14, 0'
14' 0'
14' 0'
14' 0'
#3
4' 9'
7' 4'
7' 10'
9' 8'
10' 1'
11' 7'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
�--i
D P L
Stud
4' 9'
7' 4'
7' 10'
9' 8'
10' 1'
11' 7'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
Standard
4' 7'
6' 6'
6' 11'
8' 8'
9' 3'
11' 6'
12' 0'
13' 7'
1 14' 0'
14' 0'
14' 0'
�ymm
About:
able Truss
Diagonal brace options
vertical length may be T
doubled when diagonal 18'
brace Is used. Connect
diagonal brace for 600# •L• L
at each end. Max web Brace 01/q # /'I�
total length Is 14'. © ®e �' �OAt
2x6 DF-L #2 or I <� ® ` p /
better diagonal T- tl �A 40
Vertical length shown bracer single 8, p
In table above. or double cut
45' (as shown) at L 1
upper end.
—
onSiy_gNs®Bearing
Connect diagonal at r. 449l C C
midpoint of vertical web. Refer to chart ab0 ill^ P70. �vrtrtiticn
"VARN M" READ AND FULLOW ALL NOTES ON THIS DRAWING! a01
W ; � a�e�4
"IKPORTANTv FURNISH THIS DRAWINGi TO ALL COMACT13RS INCLUDING THE INSTALLERS OTrusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to andfollow the latest edition of BCSI (Building Component Safety Information, by TPI and SECA) for safety ®1practices prior to performing these functions.Installers shot( provide temporary brndng per BCSL ��I/j\ lAUnless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord i/j1)Hshall have a properly attached rigid ceiling. Locations shown far permanent lateral restraint of webs��t�i1,0
shall have bracing Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to each face
of truss and position as shown above and an the Joint Details, unless noted otherwise,
�I E, Refer to drawings 160A-2 for standard plate positions.
Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any deviation from
this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping,
AN ITW COMPANY Installation & bracing of trusses.
A seal an this drawing or cover page Usti g this drawing, Indicates acceptance of professional
\1514\EaAh\City\Expressway engineering responsibility solely for the design sham. The suitability and use of this drawing
\\Suite\242 far any structure is the responsOiRlty of the Budding Designer per ANSI/TPI 1 Sec2. 11
\\EaAh\City.\MO\63045 For more Information see this Job's general notes page and these web sitp�/ffiR7 Yoonhwak Kim, FL PE #86367
ALPINE www.al Ineltw.coni TPI, www.tpinst.orgi SECA, www.sbcindustry.orgi ICC� wwdc
r-1
Bracing Group Species and Gradesi
Group Ai
S ruce-Pine-Fir Hen -Fir
#1 / #2 Stnndnrd #2 Stud
#3 1 Stud #3 Stnndnrd
Dou las Flr-Larch Southern Pinewww
#3 #3
Stud Stud
Standard Standard
Group BI
Hen -Fir
#1 & Btr
#1
Dou ins Fir -Larch Southern Plnewww
#1 1 #1
#2 1 1 #2
Ix4 Braces shall be SRB (Stress -Rated Board),
wwFor Ix4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards. Group B
values may be used with these grades.
Gable Truss Detail Notes:
Wind Load deflection criterion Is L/240.
Provide uplift connections for 75 plf over
continuous bearing (5 psf TC Dead Load).
Gable end supports load from 4' 0' outlookers
with 2' 0' overhang, or 12' plywood overhang.
Attach 'L' braces with IOd (0.128'x3.0' h.In) nails.
)K For (1) 'L' bracer space nails at 2' o.c.
In 18' end zones and 4' o.c, between zones,
)K)KFor (2) 'L' braces, space nails nt 3' o,c,
In 18' end zones and 6' o.c, between zones.
'L' bracing must be a minimum of 807 of web
member length.
II Gable Vertical Plate Sizes 11
Vertical Len th
No S lice
Less than 4' 0'
2X3
Greater than 4' 0', but
less than 11' 6'
3X4
Greater than 11' 6'
4X4
+ Refer to common truss design for
peak, splice, and heel plates.
Refer to the Building Designer for conditions
not addressed by this detalt.
AX. TOT, LD, 60 PSF
SPACING 24.0'
F ASCE7-10-GAB16015
TE 10/01/14
WG A16015ENC101014
Gable Stud Reinforcement Detail
ASCE 7-10: 180 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1,00
Or, 160 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00
Or: 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt =' 1.00
❑ri 140 mnh Wind Snppd. 19' Mann Hpinht. Pnrtinlly Fnrinapd. Fvnnauro n. k7+ = inn
S
2x4 Brace
Gable Vertical
Spacing Species Grade
No
Braces
(1) lx4 'L' Brace w
(1) 2x4 'L' Brace w
(2) 2x4 'L' Brace x)K
(1) 2x6 'L' Brace w
(2) 2x6 'L' Brace w
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
# 1 / #2
3' 6'
6' 0'
6' 3'
7' 1'
7' 4'
8' 5'
8' 9'
11' 1'
11' 7'
13' 3'
13' 9'
0)
U
S P P
#3
3' 4'
5' 1'
5' 5'
6' 9'
7' 3'
8' 4'
8' 8'
10' 7'
11' 4'
13' 1'
13' 7'
HF
Stud
3' 4'
5' 0'
5' 4'
6' 9'
7' 2'
8' 4'
B' B'
10, 6'
ill 3'
13' 1'
13' 7'
p
Standard
3' 4'
4' 4'
4' 7'
5' 9'
6' 2'
7' 10'
8' 5'
9' 1'
9' 8'
12' 4'
13' 2'
#1
3' 8'
6' 1'
6' 4'
7' 2'
7' 5'
8' 6'
8' 10'
11' 3'
11' 8'
13' 4'
13' 11'
S P
#2
3' 6'
5' 9'
6' 2'
7' 1'
7' 4'
8' 5'
8' 9'
11' 1'
11' 7'
13' 3'
13' 9'
#3
3' 5'
4' 7'
4' 10'
6' 1'
6' 6'
8' 2'
8' 9'
9' 6'
^c
10, '
12' 11'
13' 8'
aj
r
Stud
3' 5'
4' 7'
4' 10'
6' 1'
6' 6'
8' 2'
8' 9'
9' 6'
10' 2'
12, 11'
13' 8'
d
Standard
3' 1'
4' 0'
4' 3'
5' 4'
5' 9'
7' 3'
T 9'
8' 5'
9' 0'
11' 5'
12' 3'
U
#1 / #2
4' 0'
6' 10'
7' 2'
8' 1'
8' S'
9' 8'
10, 1'
12' 9'
13, 3'
14' 0'
14' 0'
_
S P P
#3
3' 10'
6' 2'
7' 2'
8' 0'
8' 4'
9' 7'
9'- 11'
1 12' 7'
13' 1'
14' 0'
14' 0-
u P
Stud
3' 10'
3'
6' 2'
6' 7'
8' 0'
8' 4'
9' 7'
9' 11'
12' 7'
13' 1'
14' 0'
14' 0'
QJ
o
�l
Standard
3' 10'
5' 4'
5' 8'
7' 1'
7' 7'
9' 7'
9' 11'
11' 1'
11' 11'
14' 0'
14' 0'
#1
4' 3'
7' 0'
7' 3'
8' 3'
8' 6'
9' 9'
10' 2'
12' 11'
13' 5'
14' 0'
14' 0'
S P
#2
4' 0'
6' 10'
7' 2'
8' 1'
8' 5'
9' 8'
10, 1'
12' 9'
13' 3'
14' 0'
14' 0'
#3
3' 11'
5' 7'
5' 11'
7' 5'
7' 11'
9' 7'
10, 0'
11' 8'
12' 6'
14' 0'
14' 0'
�1
i
D P L
Stud
3' 11'
5' 7'
5' 11'
7' 5'
7' 11'
9' 7'
10, 0'
11' 8'
12' 6'
14' 0'
14' 0'
Standard
3' 9'
4' 11'
5' 3'
6' 7'
7' 0'
8' ill
9' 6'
10' 4'
11' 1'
14' 0'
14' 0'
#1 / #2
4' 5'
7' 7'
7' 10'
8' 11'
9' 3'
9' 8'
11' 1'
14' 0'
14' 0'
14' 0'
14' 0'
d
Sr
P r
#3
4' 3'
7' 2'
7' 7'
8' 10'
9' 2'
10, 6'
10, 11'
13, 10'
14' 0'
14' 0'
14' 0'
LD
U
I I P
Stud
4' 3'
7' 1'
7' 7'
8' 10'
9' 2'
10' 6'
10, 11'
13' 10'
14' 0'
14' 0'
14' 0'
O
I�
Standard
4' 3'
6' 2'
6' 6'
8' 2'
8' 9'
10' 6'
10, 11'
12' 10'
13' 9'
14' 0'
14' 0'
X
#1
4' 8'
7' 8'
7' 11'
9' 0'
9' 5'
1 10' 9'
11' 2'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 5'
7' 7'
7' 10'
8' 11'
9' 3'
10, 8'
11' 1'
14' V
14' 0'
14 0'
14' 0'
#3
4' 4'
6' 5'
6' 10'
8' 7'
9' 12'
10' 7'
11' 0'
13' 5'
14' 0'
14' 0'
14' 0'
�
D F L
Stud
4' 4'
6' 5'
6' 10'
8' 7'
9' 12'
10' 7'
11' 0'
13' S'
14' 0'
14' 0'
14' 0'
Standard
4' 3'
5' 8'
6' 1'
7' 7'
8' 1'
10' 3'
1V il'
11' il'
12' 9'
14' 0'
14' 0'
Diagonal brace options
vertical length may be
doubled when diagonal
brace Is used. Connect
diagonal brace for 775#
at each end. Max web
total length Is 14'.
Vertical length shown
In table above.
Connect dlagonnl at
mldooint of vertical
AN ITW CO
\ \ 514\ Earth\ City\ Expressway
\ \ Suite\ 242
\ \ Eanh\ City,\ MO\ 63045
2x6 DF-L #2 or
better diagonal
bracer single
or double cut
(as shown) at
upper end.
Aboutj�
T
18' )K
mace L
31E 31E
T
1L Lj 1
14�1 Refer to chart aboW
wwVARND161n READ AND FDLLBV ALL NDTES ON THIS BRAVING 17,
vDNPORTANnv FURNISH THIS BRAVING TO ALL CUITRACTDRS INMUDING THE INSTALLERS. E
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and
it.. the latest editlon of BCSI (Building Component Safety Information, by TPI and SBCA) for safety
actices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
less noted otherwise, top chord shall have properly attached structural sheathing and bottom char
all have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
.all have bracing Installed per BCSI sections B3, B7 or H10, as applicable. Apply plates to each face
truss and position as shown above and on the Joint Details, unless noted otherwise.
fer to drawings 16CA-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc shall not be responsible for any deviation fr<
Is drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping,
;tallation S bracing of trusses.
A seal on this drawing or cover page Ustig this &owig, Indicates acceptance of professional
gineering responsibility solety for the design shorn The sultobUty and use of this drawing
r any structvr is the responsibility of the Budding Designer per ANSI/TPI I Sect.
For more Information see this Job's general notes page and theset,web sLll�ll(J7R
ALPINEi wwmalpineitw,conl TPD www.tpinsorgi SBCA, www,sbclndustry.argi ICd v.J 7
�III 1fI►�'of' �1 WA
'.r.,
f 3 7 ®�°el��f
o�
ma$TXTE VORICa
OR�o�
Ss+°®gym®®
hA1_ ""Odd
0 d
101
R
Bracing Group Species and Grades:
Group At
S ruce-Plne-Fir Hen -Fir
#1 / #2 IStandarl 1 #2 Stud
#3 Stud #3 Stnndnrd
Dou las Flr-Larch Southern Plnewww
#3 #3
Stud Stud
Stnndnrd Stnndnrd
Group B:
Hen -Fir
#1 & Btr
#1
Dou ins Fir -Larch Southern Plnewww
#1 #1
#2 #2
Ix4 Braces shall be SRB (Stress -Rated Board).
wwFor 1x4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards. Group B
values maybe used with these nodes.
UaIoLe I russ Detail Notes:
Wind Load deflection criterion Is L/240.
Provide uplift connections for 100 pile over
continuous bearing (5 psf TC Dead Load).
Gable end supports load from 4' 0' outlookers
with 2' 0' overhang, or 12' plywood overhang,
Attach 'L' braces with 10d (0,128'x3,0' min) nails.
)K For (1) 'L' brace, space nails at 2' o,c,
In 18' end zones and 4' o,c, between zones.
)KFor (2) 'L' braces. space nails at 3' o,c,
In IB' end zones and 6' o.c. between zones.
'L' bracing must be a minimum of 807 of web
member length.
Gable Vertical Plate Sizes
Vertical Length No Splice
+ Refer to common truss design for
peak, splice, and heel plates.
Refer to the Building Designer for conditions
not addressed by this detail.
Less than 4' 0'
2X3
Greater than 4' 0', but
4X4
Less than 10' 0'
TOT, LD, 60 PSF
MAX, SPACING 24,0'
F ASCE7-10-GAB18015
TE 10/01/14
WG A18015ENC101014
'T
Relnfo
Memk
Go
Tr
Gable Detail
For I_Pt-in VPrtir-nl<,-
Gable Truss Plate Sizes
pproprlate Alpine gable detall for
e sizes for vertical studs,
Engineered truss design for peak,
-b, and heel plates.
vertical plates overlap, use a
,te that covers the total area of
lapped plates to span the web,
ei 2*2X4
2 X 8
Provide connections for uplift specified on the engineered truss design.
Attach each 'T' reinforcing member with
End Driven Nails,
10d Common (0.148'x 3,',min) Nails at 4' o.c, plus
(4) nails In the top and bottom chords,
Toenalled Nallsb
10d Common (0.148'x3',min) Toenails at 4' o,c. plus
(4) toenails in the top and bottom chords,
This detall to be used with the appropriate Alpine gable detail for ASCE
wind load,
ASCE 7-05 Gable Detail Drawings
A13015051014, A12015051014, A11015051014, A10015051014, A14015051014,
A13030051014, A12030051014, A11030051014, A10030051014, A14030051014
ASCE 7-10 & ASCE 7-16 Gable Detail Drawings §1 CI ®y o
A11515ENC100118, A12015ENC100118, A14015ENC100118,
A18015ENC100118, A20015ENC100118, A20015END10011 �
A11530ENC100118, A12030ENC100118, A14030ENC$ QldC�0f�1',to ��
A18030ENCI00118, A20030ENC100118, A20030EN A®0 3
Q18
S11515ENC100118, S12015ENC100118, S1401SEN 0118,�3 6 011&j� �o
S18015ENC100118, S20015ENC100118, S20015E* 001IPA S 0 15P 1 B
e
S11530ENC100118, S12030ENC100118, S140300C100115, S 7 #
S18030ENC100118, S20030ENC100118, S2003 18, S20030PED100118 ff+
See appropriate Alpine gable detall for maxima unrRlnforced g e vertical l®
ov,:� ® STATE OF 0 i
'T' Reinforcement Attachment Detall.
'T' Reinforcing 'T' Relnforcing
Member Member
Toe-nall - Or - End-nall
To convert from 'L' to 'T' reinforcing members,
multiply 'T' Increase by length (based on
appropriate Alpine gable detail).
Maximum allowable 'T' reinforced gable vertical
Length Is 14' from top to bottom chord,
'T' reinforcing member material must match size,
specie, and grade of the 'L' reinforcing member,
✓eb Length Increase w/ 'T° Brace
'T' Relnf.
Mbr. Size
'T'
Increase
2x4
30
2x6
20
Examples
ASCE 7-10 Wlnd Speed = 120 mph
Mean Roof Height = 30 ft, Kzt = 1.00
Gable Vertical = 24'o.c. SP #3
'T' Reinforcing Member Size = 2x4
'T' Brace Increase (From Above) = 307 = 1.30
(1) 2x4 'L' Brace Length = 8' 7'
Maximum 'T' Reinforced Gable Vertical Length
1.30 x 8' 7' = 11' 2'
..vARNDaa.. RIJD AND FD(lOV ALL I�TEs ON THIS DRAVINa ® ®� ����
wwDPDRTANTww FURNISH THIS DRAVM TO ALL CONTRACTORS INCLUDING THE INSTALLERS. IV rto 40..- ��® / REF LET -IN VERT
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing: Refer to and ("1 9 p ®®0 DATE O1/�2/2018
follow the latest edition of SCSI (Building Component Safety Information, by TPI and SBCA) for safety 0 l.)
proctices prior to performing these functions. Installers shall provide temporary bracing per MI, a� `
Unless noted otherwise, top chord shot( have properly attached structural sheathing and bottom chord <
shop have a property attached rigid calling. Locations shown for permanent lateral restraint of webs///d�+'�o, i1��11 DRWG GBLLETIN0118
�, shall have bracing Installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face
of truss and pasitlon as shown above and on the Joint Detalls, unless noted otherwise.
�I E Refer to drawings 160A-Z for standard plate positions.
Alpine, a division of ITV Building Components Group Inc, shall not be responsible for any deviation from
this drawing, any falture to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, )AX, TAT, LD, 60 PSF
ANITWCOMPANY Installation & bracing of trusses.
1 \ 6141 Eadh\ Cit \ Expressway A seal on this drawing or cover page listing this drawing. lndcates acceptance of professional
y p y engineering responsibility solely for the design shown The suitability and use of this drawing D U R, F A C, A N Y
\\Suite\242 for any structure Is the responsibility of the Building Designer per ANSI/TPI 1 SecZ
l\ Earth\ City,\ MO\63046 For more Information see this Job's general notes page and these web MAX, SPACING 24,0'
ALPINE, www,alpineltw.comi TPI, www.tpinst.orgi SBCA, wwwsbclndustry.orgi ICC, vw n
'T
Relnfol
Memb
Go,
Tr
Gable Detail
Fnr I Pt -in VPrt1r"(11cz
Gable Truss Plate Sizes
pproprlate Alpine gable detail for
e sizes for vertical studs.
Engineered truss design for peak,
b, and heel plates.
vertical plates overlap, use a
to that covers the total area of
lapped plates to span the web.
2X4
2X4 *2X8
Provide connections for uplift specified on the engineered truss design.
Attach each 'T' reinforcing member with
End Driven Nails,
IOd Common (0,148'x 3.',min) Nails at 4' o.c. plus
(4) nails In the top and bottom chords,
Toenalled Nalls-
10d Common (0,148'x3',min) Toenails at 4' o,c, plus
(4) toenails In the top and bottom chords.
This detail to be used with the appropriate Alpine gable detail for ASCE
wind load.
ASCE 7-05 Gable Detal( Drawings
A13015051014, A12015051014, A11015051014, A10015051014, A14015051014,
A13030051014, A12030051014, A11030051014, A10030051014, A14030051014
ASCE 7-10 Gable Detall Drawings ® gg
A11515ENC101014, A12015ENC101014, A14015ENC101014,
A18015ENC101014, A20015ENC101014, A20015END1010A
A11530ENC101014, A12030ENC101014, A14030ENCQE1A03014, /� AP
A18030ENC101014, A20030ENC101014, A20030EN,�,01 { A00 3 i '.�/ 10i
S11515ENC100815, S12015ENC100815, S14015Et100815QaS1 0 �®
518015ENC100815, S20015ENC100815, S20015�D1008b5, ��j,O,15P D 0 8 �s ®�
S11530ENC100815, S12030ENC100815, S14030�'NC100015, %I�0 8 •
r
S18030ENC100815, S20030ENC100815, S2003VLQkO§815, SP-0030PED100815 0 0
See appropriate Alpine gable detail for maximum unrwinforced a vertical long hZ
STATE OP o
'T' Reinforcement Attachment Detall
'T' Reinforcing 'T' Reinforcing
Member Member
Toe-nall - Or - End-nall
To convert from 'L' to 'T' reinforcing members,
multiply 'T' Increase by length (based on
appropriate Alpine gable detall).
Maximum allowable 'T' reinforced gable vertical
length Is 14' from top to bottom chord.
'T' reinforcing member material must match size,
specie, and grade of the 'L' reinforcing member.
Jeb Length Increase w/ 'T' Brace
'T' Relnf.
Mbr, Size
'T'
Increase
2x4
30
2x6
20
Example
ASCE 7-10 Wind Speed = 120 mph
Mean Roof Height = 30 ft, Kzt = 1.00
Gable Vertical = 24'o,c. SP #3
'T' Reinforcing Member Size = 2x4
'T' Brace Increase (From Above) = 307 = 1.30
(1) 2x4 'L' Brace Length = 8' 7'
Maximum 'T' Reinforced Gable Vertical Length
1.30 x 8' 7' = 11' 2'
s
■■VARNINGi■■ READ AND FOLLOV ALL NOTES W THIS DRAWING[ �� W ® 0���(1
aDwaRTANT■■ FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INST&LERS. "o ri` p rQ ° ��aREF LET -IN VERT
Trusses require extreme care In fabricating, handUng, shipping, InstalUng and bracing. Refer to and �l1 • DATE- 10/O1/14
follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety
practices prior to performing these functions. Installers shall provide temporaryy bracing per BCSI. red
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord / �! Y
�. shall have a properly attached rigid telling. Locations shown for permanent lateral restraint of webs �Ip9Ed �e,e► DRWG GBLLETIN1014
�F^�� shall have bracing Installed per above
sections the
B7 or B30, as applicable. Apply plates to each face
d I��LU�J�)1 of truss and position as shown above and an the Joint DetnOs, unless noted otherwise.
Refer to drawings 160A-Z for standard plate positions.
Alpine, a dvlslon of ITV Building Components Group Inc shall not be responsible for any deviation from
AN ITW COMPANY this drawing, any follure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, )AX, T❑T, LD, 60 PSF
Installation 6 bracing of trusses.
A seal on this drawling or cover page Usti g this drawing, Indcates acceptance of professional
\\ 13723% Riverportl Drive engineering responsibility solely for the design shown. The suitobtity and use of this drawing OUR, FAC, ANY
II Suite%200 for any structure Is the responsibility of the MoUrg Designer per ANSI/TPI 1 Sec2.
\\Maryland\Heights,\MO\63043 For more Information see this Job's general notes page and these web sit �}ty� �,'] yoonhwak Kim, FL PE #86367
ALPINE, www,alpineltw,comi TPIi www.tpinst.orgi SBCAi www.sbctindustry,orgi ICC, v.,c s E.a MAX, SPACING 24,0'
Valley Detail - ASCE 7-10: 160 mph, 30' Mean Height, Enclosed, Exp, C, Kzt=1,00
Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better,
Bot Chord 2x4 SP #2N or SPF #1/#2 or better.
Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better,
�" Attach each valley to every supporting truss withi
(2) 16d box (0,135' x
3,5') nails toe -nailed for
ASCE 7-10 160 mph,
30'
Mean
Height, Enclosed
Building, Exp, C, Wind
TC
DL=5
psf, Kzt = 1.00
Or
ASCE-7-10 140 mph,
30'
Mean
Height, Enclosed
Building, Exp, D, Wind
TC
DL=5
psf, Kzt = 1.00
Bottom chord may be square or pitched cut
as shown.
Valleys short enough to be cut as solid triangular
members from a single 2x6, or larger as required,
shall be permitted in lieu of fabricating from
separate 2x4 members,
All plates shown are ITW BCG Wave Plates
3X4
12
12 Max. I
2X4 X4
8-0-0 max
4X4
20-0-0 (++)
Supporting trusses at 24' o,c, maximum spacing,
Unless specified otherwise on engineer's sealed design, for vertical
valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80Y length of
web, same species and grade or better, attached with 10d box
(0,128' x 3,0') nails at 6' o,c, In lieu of 'T' reinforcement, 2x4 Continuous
Lateral Restraint applied at mid -length of web is permitted with diagonal
bracing as shown in DRWG BRCLBANC1014,
Top chord of truss beneath valley set must be braced with)
properly attached, rated sheathing applied prior to valley truss
Installation.
Or
Purlins at 24' o,c, or as otherwise specified on engineer's sealed design
Or
By valley trusses used in lieu of purlin spacing as specified on
Engineer's sealed design.
WWX Note that the purlin spacing for bracing the top chord of the truss
beneath the valley is measured along the slope of the top chord.
++ Larger spans may be built as long as the vertical height does
not exceed 14'-0'.
Valle
Spacing
Pitched Cut
Bottom Chord
Valley
Toe -nailed
X4
We
g
■■VARNINGww READ Arm FDLLDV ALL MIES ON TRIS DRAVIM '- f
N TANTa FMUSH MIS DRAVING TD ALL CWIRACTMS INCLUDIrlra THE INSTALLERS. d'O�
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and0
follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety
practices prior to performing these functions. Installers shall provide temporary bracing per BCSL
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chor
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
,¢z shall have bracing Installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face
of truss and position as shown above and on the Joint Details, unless noted otherwise.
I �' Refer to drawings 160A-Z for standard plate positions.
Alpine, a division of ITV Building Components Group Inc shall not he responsible for any deviation frc
this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping,
AN rrW COMPANY installation L bracing of trusses.
\ \ 5141 Earth1 Cil \ Expressway A seal on this drawing ar cover page llsti g this drawing, Indicates acceptance of professional
IISuite%242 Y P Y fergir�ey responsibility the olely far the deMM responsibility of the Building The suir per
NSIand use of this drawing
structure dog Designer per ANSI/TPI 1 Sec2.
\ \ Earth\ City,\ MO\ 63045 For more Information see this Job's general notes page and these web t
ALPINE, www.atpineitw.coml TPD www.tpinst,orgl SEC& www.sbclndustry.orgi ICO v
Square Cut
Bottom Chord
Valley
11 11@4i11 ►d +�
A--
4D v
E
No. 86 -17
Corr
STATE OF v �
2X4
Stubbed Valley
End Detail
L1
4X4
Optional Hip
Joint Detail
24'
Partial Framing
Plan
LL 30 30 40PSF REF VALLEY DET,
DL 20 15 7 PSF DATE 10/01/2014
DL 10 10 10 PSF DRWG VAL160101014
LL 0 0 0 PSF
LD, 60 55 57PSF
IDUR,FAC,1.25/1,3311.15 11.15 1
24,0'
VALLEY FRAMING & BRACING DETAIL
R
BC
'/2
of
Lumber Size and Grade Minumum Requirements
GENERAL NOTES
Purlins required 2'-0" O.C. in absence of plywood sheathing.
Trusses without sheathing applied must be evaluated accordingly.
Purlins should overlap sheathing one truss spacing minimum.
In cases that this Is impractical, overlap sheathing a minimum
of 6", and nail upwards through sheathing into purlin with a
minimum of 8-8d (0.131"x2.5") common wire nails.
Effects of not providing sheathing below a valley set
must be evaluated by the building designer.
This drawing applies to valleys with the following conditions:
Spans (distance between heels) 40'-0" or less
-Maximum valley height: 14'-0"
-Maximum mean roof height: 30 feet
-ASCE 7-05, 140 mph, Enclosed, Cat 11, Exp B,1=1.0, Kzt=1.0
-Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0
TRUSS
TRUSS UNDER VALLEY FRAMING
VALLEY RAFTER OR RIDGE
® +CRIPPLE
ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max.
re the crippes for each row starting from the valleys or sleepers
working inward to the ridge board so that cripple locations are
gored between rows.
ITYP)
innection Requirement Notes
2x6 rafters to ridge
416d toe -nails
Cripple to ridge
416d toe -nails
Cripple to rafter
416d toe -nails
(••) 816d face -nails
Rafter to sleeper or blocking
5 16d toe -nails
Rafter to two 2x6 sleepers
416d toe -nails
Sleeper to truss
416d toe -nails
Two 2x6 sleepers to truss
3 16d toe -nails each sleeper & truss
Ridge board to roof block
416d toe -nails
Ridge board to truss
416d toe -nails
Purlin to (Typ)
316d toe -nails
Truss to blocking
416d toe -nails
Truss to cripple
416d toe -nails
Truss to cripple
416d toe -nails
Cripple to purlin
316d toe -nails
°�V' �`�"� J"`r 13. Collar beam to rafter 416d toe -nails
CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d (0.162"x3.5") COMMON NAILS
-2x4 continuous lateral restraint (CLR) min. is required for cripples 5'-0" to 10'-0" Tong
nailed w/ 2 -10d (0.148"x3") nails. Or 2x4 "T" or scab reinforcement nailed to flat edge
of cripple with 10d �0.128"x3.0") nails at 6" o.c. "T" or scab must be 90 % of cripple length.
Cripples over 10'-0' long require two CLR's or both faces w/ "T" or scab. Use stress
graded lumber & box or common nails.
Narrow edge of cripple can face ridge or rafter,
as long as the proper number of nails are
Installed Into ridge board
-Install blocking under rafter if sleepers are not used.
-install blocking under cripples If cripples fall between
lower truss top chords and lateral bracing Is not used.
-Apply all nailing In accordance to current NOS requirem
Nails are common wire nails unless noted otherwise *A H. ff4i�y
_`
��lr �GENSF
•
V °• � ° i I
s (A)
(B) ')
-WARNWit •READ AND FOLLDV ALL Nams m nUS DRAVDa3
oDf�[R'TAHie FURN M TM DPAVD/C. M ALL CMURACtvRS DCLIDDM Tic DtSTAL�-_-_ °
Trusses require extreme Infabr4catwp, hardliug,
� =
TC LL 20
30 40 54
REF VALLEY FRAMING
DATE 10/01/14
care whipping, Installing andb
brache Ref.8
follow the latest edition of BCS1 (RRdirg Component Safety Informilon,'by TPI and SBCA) foGcdfetA
`
TC DL 10
20 7 7
pmc ices pMar to perfarnig these functions. Installers shall provide temporary bracing Pell BCSL.
UNese noted otherwise, tap chard shall have property attached structural sheathing and bot},on chartl
shall have a property attached clod celip Locations sham far lateral
• _
/�
STATE (�
BC DL 0
0 0 0
DRWG VACNV1801015
^
d �p���
pe„anent rest—lintaf
shall have bmcbq Installed per BCSL sections B3, 87 or B10, as applkohle, Apply plates to e.css f
of truss and posnlon as clown above and on the Joint BetaLs, unless noted otherwise, i
✓1
x
°• qq we 46 L(
• L.
_••�eA
BC LL 0
0 0 0
Refm to dmwtrps 160A-Z for standard plate positions.
oA
•^L OI'� 1 f
••••.w1Y»�[..°•°•°
M7 fIWOoAAPAW
this a Wlslon of ITV Building Components rrow Inc, shalt not be respansble for any davfatior��i
snip, any fa!Lr to build the truss In conformance with ARSI/IPI 1, or for handUrq, Vippl
Instalatkm 4 bracing of trusses,
�C�O`
SS1ONAL G�
TOT. LD.30
50 47 61
A seat on this1dmwka or cover page Ustkp this d^nwFp, Ywscates a¢eptance of professlonol
nor the d aa"`'b
uzrpiueerrp n.spOn>blttth
t�'
` ��'
'fi
r q
for my � r'•ty of the a. m:> pen. AeaviP�1 i S—Z
DUR. FAC. 1.25/1.15
13389 Lakelronl DrNe
Earth City. M063046
For none information see this Job's general notes page ad these web sites
ALPM malpineltweami TPI..w..tps itoM SBCly _.bdndustrya.w.. rg, IM kesafwarp
Q /, ���
(�J ll
SPACING SEE ABOVE