Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Certification for Design Load Compliance
_ RECEIVED rS ) 1 �Y L Planning & Development Services Department © �. r . APR 2 9 2019 . ... Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 ST Lucie County, Permitting Certification for Design Load Compliance Project Name: TAYLOR RESIDENCE copy Project Address: 5012 WATERSONG WAY, FORT PIERCE FL 34949 Permit #: Occupancy Type: �r? 3 Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: at New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Z. d) ('7 Code Sixth Edition with 20 Supplements using SCE 7- 2. Structure Designed as (check one): ✓Enclosed Partially Enclosed —Open 3. Risk Category: I V II III IV / Exposure Category: B C 14 4. Design Wind Velocity 1-70 mph Z ASD LRFD End Zone Width: a.. O ft 5. Mean Roof Height 37 ft Roof Pitch: 7 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): ti Zone 1: �' � Zone 2: Zone 3: / Z9,4 Zone 4: 5 , z Zone 5: 6 2-, F Garage: s 40- �- 3 7. Design Loads: Floor: 4.0 PSF Roof/Dead: 2-5- PSF Roof/Live: 3� Balcony: 4-49 441-tPSF Dock: N/k PSF Deck: PSF Stairs: �• 4-PSF Fence: PSF Railings: ZA9PSF 4,ti•T4ge14c- t_ cu it 0 8. Were Shear Walls Considered For Structure? Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? V'Yes- Not Applicable Explain Why Not: - 10. Design Soil Bearing Pressure: Nh- PSF Soil Test Reports Submitted? Yes CJN r'I L.INcs DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Print Name Cert # & Co. Cert Auth. G. /-, 0 y Z Z/ 4 kk1s. f i !J V e y j 3 'r /a_ IZ c- A[ A. , r4- Sig Lure, Date, and Seal 4, © 7- 3 � v- 13 n/� wy tZD.a.� Ad-e-wdra- Fi_ 26 Company Name & Address Revised 12/07/2018