HomeMy WebLinkAboutEnergy Code�p_Af) 4? D I-!- oco Y o FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TAYLOR RESIDENCE Builder Name: COASTAL CONSTRUCTION Street: 5012 WATER SONG WAY Permit Office:, ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: GREG TAYLOR Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (4887.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=9.0 4797.00 ft2 b. Frame - Wood, Adjacent R=11.0 90.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2009.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=22.0 2009.00 ft2 6. Conditioned floor area above grade (ft2) 4494 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(989.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Dbl, U=0.79 613.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 250 SHGC: SHGC=0.28' b. U-Factor: Dbl, U=1.06 254.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.39 a. Central Unit 46.5 SEER:16.00 b. Central Unit 34.2 SEER:16.00 c. U-Factor: Dbl, U=1.06 80.00 ft2 SHGC: SHGC=0.30 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 42.00 ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: other (see details) b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4.407 ft. Area Weighted Average SHGC: 0.305 14. Hot water systems a. Electric Cap: 80 gallonsEF: 8. Floor Types (1922.5 sgft.) Insulation Area 0.950 a. Raised Floor R=19.0 1859.50 ft2 b. Conservation features b. Raised Floor R=30.0 63.00 ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.220 Total Proposed Modified Loads: 151.11 PASS Total Baseline Loads: 151.23 I hereby certify that the plans and specifications covered by Review of the plans and �ZiiE ST,q�, this calculation are in compliance with the Florida Energy specifications covered by thisti���� Code. calculation indicates compliance with the Florida Energy Code.auf h m,,,`�•••, ,;a4„ O� PREPA D BY: Before construction is completed DATE: this building will be inspected for compliance with,Section 553.908 t, "4N' a I hereby certify that this buil de ned, is in compliance Florida Statutes. with the Florida Energy C OWNER/AGENT: BUILDING OFFICIAL: - DATE: -A 4Z� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires'an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FILE COPY 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLI5T REPORT PROJECT Title: TAYLOR RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4494 Lot # Owner Name: GREG TAYLOR Total Stories: 3 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: COASTAL CONSTRUCTION Rotate Angle: 0 Street: 5012 WATER SONG W Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: ST. LUCIE COUNTY, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp 1/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT 1 2606 28062 2 UNIT 2 1888 16992 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FLEX ROOM 517 4653 No 0 1 Yes Yes Yes 2 LAUND. 65 585 No 0 1 Yes Yes Yes 3 CABANA 100 900 No 0 1 Yes Yes Yes 4 STAIR 99 891 No 0 1 Yes Yes Yes 5 FOYER 244 2196 No 0 1 Yes Yes Yes 6 ELE 25 225 No 0 1 No Yes Yes 7 GREAT ROOM 564 6768 No 0 1 Yes Yes Yes 8 STAIRWAY 243 2916 No 0 1 Yes Yes Yes 9 KITCHEN 300 3600 Yes 0 1 Yes Yes Yes 10 LAUNDRY 82 984 No 0 1 Yes Yes Yes 11 BEDROOM 4 190 2280 No 1 1 1 Yes Yes Yes 12 ELEVATOR 25 300 No 0 1 No Yes Yes 13 BATH 4 60 720 No 0 1 Yes Yes Yes 14 POWDER 72 864 No 0 1 Yes Yes Yes 15 A/C 2 20 180 No 0 1 No Yes Yes 16 MASTER BATH 200 1800 No 0 1 Yes Yes Yes 17 TOILET 24 216 No 0 1 Yes Yes Yes 18 M WIC 83 747 No 0 1 Yes Yes Yes 19 WIC 48 432 No 0 1 No Yes Yes 20 WIC 2 42 378 No 0 1 Yes Yes Yes 21 MASTER SUITE 515 4635 No 0 1 1 Yes Yes Yes 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY GNEGKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 BEDROOM 2 195 1755 No 0 1 1 Yes Yes Yes 23 HALLWAY 228 2052 No 0 1 Yes Yes Yes 24 STARIWAY. 104 936 No 0 1 Yes Yes Yes 25 BATH 2 50 450 No 0 1 Yes Yes Yes 26 WIC 3 50 450 No 0 1 Yes Yes Yes 27 BEDROOM 3 168 1512 No 0 1 1 Yes Yes Yes 28 BATH 3 50 450 No 0 1 Yes Yes Yes 29 OFFICE 131 1179 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor FLEX ROOM -__- ____ 517 ft2 19 0 1 0 2 Raised Floor LAUND. ____ ____ 65 ft2 19 0 1 0 3 Raised Floor CABANA ___- ___- 100 ft2 19 0 1 0 4Raised Floor STAIR ____ ____ 99ft2 19 0 1 0 5 Raised Floor FOYER ____ ____ 244 ft2 19 0 1 0 6 Raised Floor ELE ____ ____ 25 ft2 19 0 1 0 7 Raised Floor STAIRWAY _--- __-_ 56 ft2 19 0 0 1 8 Raised Floor KITCHEN ____ ____ 90 ft2 19 0 0 1 9 Raised Floor KITCHEN ____ -___ 35 ft2 30 0 1 0 10Raised Floor LAUNDRY ____ ____ 72 ft2 19 0 0 1 11Raised Floor LAUNDRY ____ ____ 10 ft2 19 0 1 0 12Raised Floor BEDROOM 4 ____ ____ 190 ft2 19 0 0 1 13Raised Floor ELEVATOR ____ ____ 25 ft2 19 0 0 1 14Raised Floor BATH 4 ____ ____ 60 ft2 19 0 0 1 15Raised Floor POWDER ____ ____ 8 ft2 19 0 0 1 16Raised Floor POWDER _--_ ____ 56 ft2 19 0 1 0 17Raised Floor A/C 2 ---_ --_- 5 ft2 19 0 0 1 18Raised Floor MASTER BATH ____ ____ 28 ft2 30 0 1 0 19Raised Floor MASTER SUITE ____ ____ 4.5 ft2 19 0 1 0 2013alsed Floor BEDROOM 3 ____ ____ 112 ft2 19 0 1 0 21Raised Floor BATH 3 ____ ____ 40 ft2 19 0 1 0 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT 5UMMAKY GIIEGKLI5T KEPUK f FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 22Raised Floor OFFICE ---- ---- 81 ft2 19 0 1 0 ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2209 ft2 0 ft2 Unfinishe N 0.6 No 0.6 No 22 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2096 ft2 N N CEILING # Ceiling Type Space R-Value_ Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) FLEX ROOM 0 Blown 101 ft2 0.1 Wood 2 Under Attic (Unvented) LAUND. 0 Blown 25 ft2 0.1 Wood 3 Under Attic (Unvented) GREAT ROOM 0 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) MASTER BATH 0 Blown 166 ft2 0.1 Wood 5 Under Attic (Unvented) TOILET 0 Blown 24ft2 0.1 Wood 6 Under Attic (Unvented) M WIC 0 Blown 83 ft2 0.1 Wood 7 Under Attic (Unvented) WIC 0 Blown 48 ft2 0.1 Wood 8 Under Attic (Unvented) WIC 2 0 Blown 42 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER SUITE 0 Blown 515 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 0 Blown 195 ft2 0.1 Wood 11 Under Attic (Unvented) HALLWAY 0 Blown 228 ft2 0.1 Wood 12 Under Attic (Unvented) STARIWAY. 0 Blown 104 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 2 0 Blown 50 ft2 0.1 Wood 14 Under Attic (Unvented) WIC 3 0 Blown 50 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 3 0 Blown 168 ft2 0.1 Wood 16 Under Attic (Unvented) BATH 3 0 Blown 50 ft2 0.1 Wood 17 Under Attic (Unvented) OFFICE 0 Blown 124 ft2 0.1 Wood WALLS # Ornt Adjacent To Wall TypeSpace Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - PolystyftEX ROOM 9 18 0 9 0 162.0 ft2 0 0 0.3 0 _ 2 E Exterior Concrete Block - Polystyd&EX ROOM 9 30 0 9 0 270.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block - PolystyFd3EX ROOM 9 5 0 9 0' 45.0 ft2 0 0 0.3 0 4 N Exterior Concrete Block- PolystyrerhAU ND. 9 10 0 9 0 90.0 ft2 0 0 0.3 0 _ 5 E Exterior Concrete Block - Polystyrerle4UND. 9 1 0 9 0 9.0 ft2 0 0 0.3 0 6 W Exterior Concrete Block- Polystyrerle4UND. 9 7 0 9 0 63.0 ft2 0 0 0.3 0 _ 7 W Exterior Concrete Block - PolystyreiG4BANA 9 10 0 9 0 90.0 ft2 0 0 0.3 0 8 W Exterior Concrete Block - PolystyreneSTAIR 9 11 0 9 0 99.0 ft2 0 0 0.3 0 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FORnn R4n5-9n17 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt In Space Wall Type Et In Et In Area R-\/qllle Eraction AhS 9 S Exterior Concrete Block - PolystyrenEOYER 9 8 0 9 0 72.0 ft2 0 0 0.3 0 _ 10 W Exterior Concrete Block - PolystyrenEOYER 9 21 0 9 0 189.0 ft2 0 0 0.3 0 11 N Exterior Concrete Block - Polystyi%REAT ROO 9 21 0 12 0 252.0 ft2 0 0 0.3 0 _ 12 NE Exterior Concrete Block- Polystyi%REAT ROO 9 9 11 12 0 119.0 ft2 0 0 0.3 0 _ 13 E Exterior Concrete Block - Polystyi%REAT ROO 9 14 0 12 0 168.0 ft2 0 0 0.3 0 _ 14 W Exterior Concrete Block - Polystyi%REAT ROO 9 21 0 12 0 252.0 ft2 0, 0 0.3 0 15 W Exterior Concrete Block - Polystyr&TFAIRWAY 9 24 0 12 0 28B.0 ft2 0 0 0.3 0 _ 16 E Exterior Concrete Block - PolystyreKibTCHEN 9 14 0 12 0 168.0 ft2 0 0 0.3 0 _ 17 E Exterior Concrete Block- PolystyrdAUNDRY 9 9 0 12 0 108.0 ft2 0 0 0.3 0 _ 18 E Exterior Concrete Block - PolystyREDR00M 4 9 13 0 12 0 156.0 ft2 0 0 0.3 0 19 S Exterior Concrete Block - PolystyBEDROOM 4 9 14 0 12 0 168.0 ft2 0 0 0.3 0 20 S Exterior Concrete Block - PolystyrenBATH 4 9 5 0 12 0 60.0 ft2 0 0 0.3 0 _ 21 W Exterior Concrete Block - PolystyrenBATH 4 9 4 0 12 0 48.0 ft2 0 0 0.3 0 _ 22 S Exterior Concrete Block - PolystyreROWDER 9 9 0 12 0 108.0 ft2 0 0 0.3 0 _ 23 W Exterior Concrete Block - PolystyreROWDER 9 8 0 12 0 96.0 ft2 0 0 0.3 0 _ 24 N Exterior Concrete Block - PolystyTER BA 9 14 0 9 0 126.0 ft2 0 0 0.3 0 25 E Exterior Concrete Block - PolystyTER BA 9 6 0 9 0 54.0 ft2 0 0 0.3 0 26 W Exterior Concrete Block - Polystyftt*BTER BA 9 16 0 9 0 144.0 ft2 0 0 0.3 0 27 W Exterior Concrete Block - Polystyren*EOILET 9 4 10 9 0 36.0 ft2 0 0 0.3 0 _ 28 W Exterior Concrete Block - PolystyrenU WIC 9 12 0 9 0 108.0 ft2 0 0 0.3 0 29 E Exterior Concrete Block - PolystyreneMC 2 9 6 0 9 0 54.0 ft2 0 0 0.3 0 30 N Exterior Concrete Block - PolystyMASTER SUI 9 14 0 9 0 126.0 ft2 0 0 0.3 0 _ 31 E Exterior Concrete Block - PolystyMASTER SUI 9 20 0 9 0 180.0 ft2 0 0 0.3 0 _ 32 E Exterior Concrete Block - Polystyfi6IJROOM 2 9 13 0 9 0 117.0 ft2 0 0 0.3 0 _ 33 W Exterior Concrete Block - PolystyrEHALLWAY 9 7 0 10 0 70.0 ft2 0 0 0.3 0 34 W Exterior Concrete Block - Polystyr&TiARIWAY. 9 13 0 9 0 117.0 ft2 0 0 0.3 0 _ 35 E Exterior Concrete Block - PolystyrenBATH 2 9 5 0 9 0 45.0 ft2 0 0 0.3 0 36 E Exterior Concrete Block - PolystyreneNlC 3 9 5 0 9 0 45.0 ft2 0 0 0.3 0 37 E Exterior Concrete Block - Polysty86DROOM 3 9 12 0 9 0 108.0 ft2 0 0 0.3 0 _ 38 S Exterior Concrete Block - Polysty&BDROOM 3 9 14 0 9 0 126.0 ft2 0 0 0.3 0 39 S Exterior Concrete Block - PolystyrenBATH 3 9 5 0 9 0 45.0 ft2 0 0 0.3 0 40 W Exterior Concrete Block - PolystyrenBATH 3 9 3 0 9 0 27.0 ft2 0 0 0.3 0 41 S Exterior Concrete Block - PolystyrerQFFICE 9 9 0 9 0 81.0 ft2 0 0 0.3 0 42 W Exterior Concrete Block - Polystyrer@FFICE 9 12 0 9 0 108.0 ft2 0 0 0.3 0 43 N Garage Frame - Wood OFFICE 11 10 9 90.0 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood FLEX ROOM None .2 .1 .1 .0 ft2 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 1.06 0.39 N , 80.0 ft' 4 ft 0 in 1 ft 4 in Drapes/blinds Exterior 1 2 E 2 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft' 2 ft 0 in 7 ft 0 in None None 3 N 4 Vinyl Low-E Double Yes 0.79 0.28 N 24.0 ftz 2 ft 0 in 7 ft 0 in None None 4 W 7 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ft' 2 ft 0 in 27 ft 0 in None None 5 S 9 Vinyl Low-E Double Yes 0.79 0.28 N 48.0 ft' 5 ft 0 in 0 ft 5 in None None 6 W 10 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ft' 2 ft 0 in 27 ft 0 in None None 7 N 11 Vinyl Low-E Double Yes 1.06 0.39 N 112.0 ft' 8 ft 0 in 1 ft 0 in None None 8 NE 12 Vinyl Low-E Double Yes 1.06 0.39 N 62.0 ft' 10 ft 0 in 1 ft 0 in None None 9 E 13 Vinyl Low-E Double Yes 0.79 0.28 N 56.0 ft' 2 ft 0 in 1 ft 0 in None None • 10 W 14 Vinyl Low-E Double Yes 0.79 0.28 N 42.0 ftZ 2 ft 0 in 1 ft 0 in None None 11 W 15 Vinyl Low-E Double Yes 0.79 0.28 N 24.0 ft' 2 ft 0 in 13 ft 0 in None None 12 E 16 Vinyl Low-E Double Yes 0.79 0.28 N 18.0 ft' 2 ft 0 in 13 ft 0 in None None 13 E 17 Vinyl Low-E Double Yes 0.79 0.28 N 14.0 ft' 2 ft 0 in 13 ft 0 in None None 14 E 18 Vinyl Low-E Double Yes 0.79 0.28 N 28.0 ftZ 2 ft 0 in 3 ft 5 in None None 15 S 19 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ftZ 5 ft 0 in 0 ft 5 in Drapes/blinds Exterior 1 16 S 19 Vinyl Law-E Double Yes 0.79 0.28 N 5.0 ftZ 5 ft 0 in 3 ft 5 in None None 17 S 19 Vinyl Low-E Double Yes 0.79 0.28 N 8.0 ftZ 2 ft 0 in 3 ft 5 in None None 18 S 20 Vinyl Low-E Double Yes 0.79 0.28 N 8.0 ftZ 2 ft 0 in 1 ft 4 in None None 19 W 23 Vinyl Low-E Double Yes 0.79 0.28 N 8.0 ftZ 2 ft 0 in 13 ft 0 in None None 20 N 24 Vinyl Low-E Double Yes 0.22 0.17 N 18.0 ftZ 2 ft 0 in 0 ft 5 in None None 21 N 24 Vinyl Low-E Double Yes 0.22 0.17 N 24.0 ftZ 2 ft 0 in 13 ft 0 in None None 22 W 27 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ftZ 2 ft 0 in 1 ft 5 in None None 23 N 30 Vinyl Low-E Double Yes 1.06 0.3 N 80.0 ftZ 8 ft 8 in 1 ft 5 in None None 24 E 31 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ftZ 2 ft 0 in 1 ft 5 in None None 25 E 32 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ftZ 2 ft 0 in 1 ft 5 in None None 26 W 33 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ftZ 2 ft 0 in 1 ft 5 in None None 27 E 35 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ftZ 2 ft 0 in 1 ft 5 in None None 28 E 37 Vinyl Low-E Double Yes 0.79 0.28 N 20.0 ftZ 2 ft 0 in 1 ft 4 in None None 29 S 38 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ftZ 5 ft 0 in 1 ft 3 in None None 30 S 38 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ftZ 2 ft 0 in 1 ft 5 in None None 31 S 39 Vinyl Low-E Double Yes 0.79 0.28 N 10.0 ftZ 2 ft 0 in 1 ft 5 in None None 32 S 41 Vinyl Low-E Double Yes 0.79 0.28 N 40.0 ftZ 5 ft 0 in 1 ft 3 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ftZ 400 ftZ loft 9 ft 19 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000319 3754.5 \ 206.12 387.63 .1875 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COP:1 34 kBtu/hr COP:1 27 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16 46.5 kBtu/hr 1590 cfm 0.85 Single SEER: 16 34.2 kBtu/hr 1026 cfm 0.85 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 80 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # --- Supply -- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handier TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 250 ft2 Attic 6 250 ft2 Attic Attic 65 ft2 Default Leakage Attic (Default) c(Default) c 65 ft2 Default Leakage Attic (Default) c(Default) c 1 1 2 2 TEMPERATURES Programable Thermostat: Y Heating H Jan H Feb HX Mar Jan Feb Mar Ceiling Fans: Jun Jul Aug Sep Oct Apr I i May lApr may XJun rl Jul rl Aug ri Sep Oct Nov txl Nov Dec H DecVenting 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66, 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 FLEX ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 LAU N D. Default(8 Ibs/sq.ft. ft2 ft 0.3 CABANA Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIR Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/sq.ft. ft2 ft 0.3 ELE Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRWAY Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 lbs/sq.ft. ft2 ft 0.3 ELEVATOR Default(8 Ibs/sq.ft. ft2 ft 0.3- BATH 4, Default(8 Ibs/sq.ft. ft2 ft 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 A/C 2 Default(8lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8lbs/sq.ft. ft2 ft 0.3 MASTER SUITE Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 Ibs/sq.ft. ft2 ft 0.3 STARIWAY. Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/s .ft. ft2 ft 0.3 OFFICE 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TAYLOR RESIDENCE Builder Name: COASTAL CONSTRUCTION Street: 5012 WATER SONG WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Y U Owner: GREG TAYLOR Jurisdiction: w Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be out neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilin s. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 80.7 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 4494 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.857 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.305 14. Heating system: Capacity 61.0 c) Area 7c. 989.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. b) Wood, raised (R-value) 9b. varies 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 9.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be install (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be complete d o nstalled code compliant features. Builder Signature: Date: Address of New Home: 5012 WATER SONG WAY City/FL Zip: ST. LUCIE COUNTY, FL 2/12/2020 2:20:11 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1