FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: TAYLOR RESIDENCE
Builder Name: COASTAL CONSTRUCTION
Street: 5012 WATER SONG WAY
Permit Office:, ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Number:
Owner: GREG TAYLOR
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (4887.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrER=9.0 4797.00 ft2
b. Frame - Wood, Adjacent
R=11.0 90.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (2009.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=22.0 2009.00 ft2
6. Conditioned floor area above grade (ft2) 4494
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(989.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Dbl, U=0.79 613.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 250
SHGC: SHGC=0.28'
b. U-Factor: Dbl, U=1.06 254.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.39
a. Central Unit
46.5 SEER:16.00
b. Central Unit
34.2 SEER:16.00
c. U-Factor: Dbl, U=1.06 80.00 ft2
SHGC: SHGC=0.30
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 42.00 ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC: other (see details)
b. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 4.407 ft.
Area Weighted Average SHGC: 0.305
14. Hot water systems
a. Electric
Cap: 80 gallonsEF:
8. Floor Types (1922.5 sgft.) Insulation Area
0.950
a. Raised Floor R=19.0 1859.50 ft2
b. Conservation features
b. Raised Floor R=30.0 63.00 ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.220 Total Proposed Modified Loads: 151.11
PASS
Total Baseline Loads: 151.23
I hereby certify that the plans and specifications covered by
Review of the plans and
�ZiiE ST,q�,
this calculation are in compliance with the Florida Energy
specifications covered by thisti����
Code.
calculation indicates compliance
with the Florida Energy Code.auf
h m,,,`�•••, ,;a4„ O�
PREPA D BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with,Section 553.908
t, "4N' a
I hereby certify that this buil de ned, is in compliance
Florida Statutes.
with the Florida Energy C
OWNER/AGENT:
BUILDING OFFICIAL: -
DATE: -A 4Z�
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires'an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FILE COPY
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 8
FORM R405-2017 INPUT SUMMARY CHECKLI5T REPORT
PROJECT
Title:
TAYLOR RESIDENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 4494
Lot #
Owner Name:
GREG TAYLOR
Total Stories: 3
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
COASTAL CONSTRUCTION
Rotate Angle: 0
Street:
5012 WATER SONG W
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
ST. LUCIE COUNTY,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design
Daily Temp
1/ Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
UNIT 1
2606
28062
2
UNIT 2
1888
16992
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
FLEX ROOM
517
4653 No
0
1
Yes
Yes
Yes
2
LAUND.
65
585 No
0
1
Yes
Yes
Yes
3
CABANA
100
900 No
0
1
Yes
Yes
Yes
4
STAIR
99
891 No
0
1
Yes
Yes
Yes
5
FOYER
244
2196 No
0
1
Yes
Yes
Yes
6
ELE
25
225 No
0
1
No
Yes
Yes
7
GREAT ROOM
564
6768 No
0
1
Yes
Yes
Yes
8
STAIRWAY
243
2916 No
0
1
Yes
Yes
Yes
9
KITCHEN
300
3600 Yes
0
1
Yes
Yes
Yes
10
LAUNDRY
82
984 No
0
1
Yes
Yes
Yes
11
BEDROOM 4
190
2280 No
1
1
1
Yes
Yes
Yes
12
ELEVATOR
25
300 No
0
1
No
Yes
Yes
13
BATH 4
60
720 No
0
1
Yes
Yes
Yes
14
POWDER
72
864 No
0
1
Yes
Yes
Yes
15
A/C 2
20
180 No
0
1
No
Yes
Yes
16
MASTER BATH
200
1800 No
0
1
Yes
Yes
Yes
17
TOILET
24
216 No
0
1
Yes
Yes
Yes
18
M WIC
83
747 No
0
1
Yes
Yes
Yes
19
WIC
48
432 No
0
1
No
Yes
Yes
20
WIC 2
42
378 No
0
1
Yes
Yes
Yes
21
MASTER SUITE
515
4635 No
0
1
1
Yes
Yes
Yes
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8
FORM R405-2017
INPUT SUMMARY GNEGKLIST REPORT
SPACES
Number
Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID
Finished
Cooled
Heated
22
BEDROOM 2
195 1755
No 0
1
1
Yes
Yes
Yes
23
HALLWAY
228 2052
No 0
1
Yes
Yes
Yes
24
STARIWAY.
104 936
No 0
1
Yes
Yes
Yes
25
BATH 2
50 450
No 0
1
Yes
Yes
Yes
26
WIC 3
50 450
No 0
1
Yes
Yes
Yes
27
BEDROOM 3
168 1512
No 0
1
1
Yes
Yes
Yes
28
BATH 3
50 450
No 0
1
Yes
Yes
Yes
29
OFFICE
131 1179
No 0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Raised Floor
FLEX ROOM
-__- ____
517 ft2
19
0
1
0
2 Raised Floor
LAUND.
____ ____
65 ft2
19
0
1
0
3 Raised Floor
CABANA
___- ___-
100 ft2
19
0
1
0
4Raised Floor
STAIR
____ ____
99ft2
19
0
1
0
5 Raised Floor
FOYER
____ ____
244 ft2
19
0
1
0
6 Raised Floor
ELE
____ ____
25 ft2
19
0
1
0
7 Raised Floor
STAIRWAY
_--- __-_
56 ft2
19
0
0
1
8 Raised Floor
KITCHEN
____ ____
90 ft2
19
0
0
1
9 Raised Floor
KITCHEN
____ -___
35 ft2
30
0
1
0
10Raised Floor
LAUNDRY
____ ____
72 ft2
19
0
0
1
11Raised Floor
LAUNDRY
____ ____
10 ft2
19
0
1
0
12Raised Floor
BEDROOM 4
____ ____
190 ft2
19
0
0
1
13Raised Floor
ELEVATOR
____ ____
25 ft2
19
0
0
1
14Raised Floor
BATH 4
____ ____
60 ft2
19
0
0
1
15Raised Floor
POWDER
____ ____
8 ft2
19
0
0
1
16Raised Floor
POWDER
_--_ ____
56 ft2
19
0
1
0
17Raised Floor
A/C 2
---_ --_-
5 ft2
19
0
0
1
18Raised Floor
MASTER BATH
____ ____
28 ft2
30
0
1
0
19Raised Floor
MASTER SUITE
____ ____
4.5 ft2
19
0
1
0
2013alsed Floor
BEDROOM 3
____ ____
112 ft2
19
0
1
0
21Raised Floor
BATH 3
____ ____
40 ft2
19
0
1
0
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8
FORM R405-2017 INPUT 5UMMAKY GIIEGKLI5T KEPUK f
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
22Raised Floor OFFICE ----
----
81 ft2
19
0
1
0
ROOF
V
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 2209 ft2
0 ft2 Unfinishe
N
0.6
No 0.6
No 22
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Unvented
0
2096 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value_
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) FLEX ROOM
0
Blown
101 ft2
0.1
Wood
2
Under Attic (Unvented) LAUND.
0
Blown
25 ft2
0.1
Wood
3
Under Attic (Unvented) GREAT ROOM
0
Blown
36 ft2
0.1
Wood
4
Under Attic (Unvented) MASTER BATH
0
Blown
166 ft2
0.1
Wood
5
Under Attic (Unvented) TOILET
0
Blown
24ft2
0.1
Wood
6
Under Attic (Unvented) M WIC
0
Blown
83 ft2
0.1
Wood
7
Under Attic (Unvented) WIC
0
Blown
48 ft2
0.1
Wood
8
Under Attic (Unvented) WIC 2
0
Blown
42 ft2
0.1
Wood
9
Under Attic (Unvented) MASTER SUITE
0
Blown
515 ft2
0.1
Wood
10
Under Attic (Unvented) BEDROOM 2
0
Blown
195 ft2
0.1
Wood
11
Under Attic (Unvented) HALLWAY
0
Blown
228 ft2
0.1
Wood
12
Under Attic (Unvented) STARIWAY.
0
Blown
104 ft2
0.1
Wood
13
Under Attic (Unvented) BATH 2
0
Blown
50 ft2
0.1
Wood
14
Under Attic (Unvented) WIC 3
0
Blown
50 ft2
0.1
Wood
15
Under Attic (Unvented) BEDROOM 3
0
Blown
168 ft2
0.1
Wood
16
Under Attic (Unvented) BATH 3
0
Blown
50 ft2
0.1
Wood
17
Under Attic (Unvented) OFFICE
0
Blown
124 ft2
0.1
Wood
WALLS
#
Ornt
Adjacent
To Wall TypeSpace
Cavity Width
Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block - PolystyftEX ROOM
9 18
0 9
0
162.0 ft2
0
0
0.3
0
_ 2
E
Exterior Concrete Block - Polystyd&EX ROOM
9 30
0 9
0
270.0 ft2
0
0
0.3
0
3
S
Exterior Concrete Block - PolystyFd3EX ROOM
9 5
0 9
0'
45.0 ft2
0
0
0.3
0
4
N
Exterior Concrete Block- PolystyrerhAU ND.
9 10
0 9
0
90.0 ft2
0
0
0.3
0
_ 5
E
Exterior Concrete Block - Polystyrerle4UND.
9 1
0 9
0
9.0 ft2
0
0
0.3
0
6
W
Exterior Concrete Block- Polystyrerle4UND.
9 7
0 9
0
63.0 ft2
0
0
0.3
0
_ 7
W
Exterior Concrete Block - PolystyreiG4BANA
9 10
0 9
0
90.0 ft2
0
0
0.3
0
8
W
Exterior Concrete Block - PolystyreneSTAIR
9 11
0 9
0
99.0 ft2
0
0
0.3
0
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8
FORnn R4n5-9n17 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
#
Ornt
In
Space
Wall Type
Et
In
Et
In
Area
R-\/qllle
Eraction
AhS
9
S
Exterior
Concrete Block - PolystyrenEOYER
9
8
0
9
0
72.0 ft2
0
0
0.3
0
_ 10
W
Exterior
Concrete Block - PolystyrenEOYER
9
21
0
9
0
189.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block - Polystyi%REAT ROO
9
21
0
12
0
252.0 ft2
0
0
0.3
0
_ 12
NE
Exterior
Concrete Block- Polystyi%REAT ROO
9
9
11
12
0
119.0 ft2
0
0
0.3
0
_ 13
E
Exterior
Concrete Block - Polystyi%REAT ROO
9
14
0
12
0
168.0 ft2
0
0
0.3
0
_ 14
W
Exterior
Concrete Block - Polystyi%REAT ROO
9
21
0
12
0
252.0 ft2
0,
0
0.3
0
15
W
Exterior
Concrete Block - Polystyr&TFAIRWAY
9
24
0
12
0
28B.0 ft2
0
0
0.3
0
_ 16
E
Exterior
Concrete Block - PolystyreKibTCHEN
9
14
0
12
0
168.0 ft2
0
0
0.3
0
_ 17
E
Exterior
Concrete Block- PolystyrdAUNDRY
9
9
0
12
0
108.0 ft2
0
0
0.3
0
_ 18
E
Exterior
Concrete Block - PolystyREDR00M 4
9
13
0
12
0
156.0 ft2
0
0
0.3
0
19
S
Exterior
Concrete Block - PolystyBEDROOM 4
9
14
0
12
0
168.0 ft2
0
0
0.3
0
20
S
Exterior
Concrete Block - PolystyrenBATH 4
9
5
0
12
0
60.0 ft2
0
0
0.3
0
_ 21
W
Exterior
Concrete Block - PolystyrenBATH 4
9
4
0
12
0
48.0 ft2
0
0
0.3
0
_ 22
S
Exterior
Concrete Block - PolystyreROWDER
9
9
0
12
0
108.0 ft2
0
0
0.3
0
_ 23
W
Exterior
Concrete Block - PolystyreROWDER
9
8
0
12
0
96.0 ft2
0
0
0.3
0
_ 24
N
Exterior
Concrete Block - PolystyTER BA
9
14
0
9
0
126.0 ft2
0
0
0.3
0
25
E
Exterior
Concrete Block - PolystyTER BA
9
6
0
9
0
54.0 ft2
0
0
0.3
0
26
W
Exterior
Concrete Block - Polystyftt*BTER BA
9
16
0
9
0
144.0 ft2
0
0
0.3
0
27
W
Exterior
Concrete Block - Polystyren*EOILET
9
4
10
9
0
36.0 ft2
0
0
0.3
0
_ 28
W
Exterior
Concrete Block - PolystyrenU WIC
9
12
0
9
0
108.0 ft2
0
0
0.3
0
29
E
Exterior
Concrete Block - PolystyreneMC 2
9
6
0
9
0
54.0 ft2
0
0
0.3
0
30
N
Exterior
Concrete Block - PolystyMASTER SUI
9
14
0
9
0
126.0 ft2
0
0
0.3
0
_ 31
E
Exterior
Concrete Block - PolystyMASTER SUI
9
20
0
9
0
180.0 ft2
0
0
0.3
0
_ 32
E
Exterior
Concrete Block - Polystyfi6IJROOM 2
9
13
0
9
0
117.0 ft2
0
0
0.3
0
_ 33
W
Exterior
Concrete Block - PolystyrEHALLWAY
9
7
0
10
0
70.0 ft2
0
0
0.3
0
34
W
Exterior
Concrete Block - Polystyr&TiARIWAY.
9
13
0
9
0
117.0 ft2
0
0
0.3
0
_ 35
E
Exterior
Concrete Block - PolystyrenBATH 2
9
5
0
9
0
45.0 ft2
0
0
0.3
0
36
E
Exterior
Concrete Block - PolystyreneNlC 3
9
5
0
9
0
45.0 ft2
0
0
0.3
0
37
E
Exterior
Concrete Block - Polysty86DROOM 3
9
12
0
9
0
108.0 ft2
0
0
0.3
0
_ 38
S
Exterior
Concrete Block - Polysty&BDROOM 3
9
14
0
9
0
126.0 ft2
0
0
0.3
0
39
S
Exterior
Concrete Block - PolystyrenBATH 3
9
5
0
9
0
45.0 ft2
0
0
0.3
0
40
W
Exterior
Concrete Block - PolystyrenBATH 3
9
3
0
9
0
27.0 ft2
0
0
0.3
0
41
S
Exterior
Concrete Block - PolystyrerQFFICE
9
9
0
9
0
81.0 ft2
0
0
0.3
0
42
W
Exterior
Concrete Block - Polystyrer@FFICE
9
12
0
9
0
108.0 ft2
0
0
0.3
0
43
N
Garage
Frame - Wood OFFICE
11
10
9
90.0 ft2
0
0.25
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood FLEX ROOM
None
.2
.1
.1
.0 ft2
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N
1
Vinyl
Low-E Double
Yes
1.06
0.39
N ,
80.0 ft'
4 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 1
2
E
2
Vinyl
Low-E Double
Yes
0.79
0.28
N
40.0 ft'
2 ft 0 in
7 ft 0 in
None
None
3
N
4
Vinyl
Low-E Double
Yes
0.79
0.28
N
24.0 ftz
2 ft 0 in
7 ft 0 in
None
None
4
W
7
Vinyl
Low-E Double
Yes
0.79
0.28
N
10.0 ft'
2 ft 0 in
27 ft 0 in
None
None
5
S
9
Vinyl
Low-E Double
Yes
0.79
0.28
N
48.0 ft'
5 ft 0 in
0 ft 5 in
None
None
6
W
10
Vinyl
Low-E Double
Yes
0.79
0.28
N
40.0 ft'
2 ft 0 in
27 ft 0 in
None
None
7
N
11
Vinyl
Low-E Double
Yes
1.06
0.39
N
112.0 ft'
8 ft 0 in
1 ft 0 in
None
None
8
NE
12
Vinyl
Low-E Double
Yes
1.06
0.39
N
62.0 ft'
10 ft 0 in
1 ft 0 in
None
None
9
E
13
Vinyl
Low-E Double
Yes
0.79
0.28
N
56.0 ft'
2 ft 0 in
1 ft 0 in
None
None
• 10
W
14
Vinyl
Low-E Double
Yes
0.79
0.28
N
42.0 ftZ
2 ft 0 in
1 ft 0 in
None
None
11
W
15
Vinyl
Low-E Double
Yes
0.79
0.28
N
24.0 ft'
2 ft 0 in
13 ft 0 in
None
None
12
E
16
Vinyl
Low-E Double
Yes
0.79
0.28
N
18.0 ft'
2 ft 0 in
13 ft 0 in
None
None
13
E
17
Vinyl
Low-E Double
Yes
0.79
0.28
N
14.0 ft'
2 ft 0 in
13 ft 0 in
None
None
14
E
18
Vinyl
Low-E Double
Yes
0.79
0.28
N
28.0 ftZ
2 ft 0 in
3 ft 5 in
None
None
15
S
19
Vinyl
Low-E Double
Yes
0.79
0.28
N
40.0 ftZ
5 ft 0 in
0 ft 5 in
Drapes/blinds
Exterior 1
16
S
19
Vinyl
Law-E Double
Yes
0.79
0.28
N
5.0 ftZ
5 ft 0 in
3 ft 5 in
None
None
17
S
19
Vinyl
Low-E Double
Yes
0.79
0.28
N
8.0 ftZ
2 ft 0 in
3 ft 5 in
None
None
18
S
20
Vinyl
Low-E Double
Yes
0.79
0.28
N
8.0 ftZ
2 ft 0 in
1 ft 4 in
None
None
19
W
23
Vinyl
Low-E Double
Yes
0.79
0.28
N
8.0 ftZ
2 ft 0 in
13 ft 0 in
None
None
20
N
24
Vinyl
Low-E Double
Yes
0.22
0.17
N
18.0 ftZ
2 ft 0 in
0 ft 5 in
None
None
21
N
24
Vinyl
Low-E Double
Yes
0.22
0.17
N
24.0 ftZ
2 ft 0 in
13 ft 0 in
None
None
22
W
27
Vinyl
Low-E Double
Yes
0.79
0.28
N
10.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
23
N
30
Vinyl
Low-E Double
Yes
1.06
0.3
N
80.0 ftZ
8 ft 8 in
1 ft 5 in
None
None
24
E
31
Vinyl
Low-E Double
Yes
0.79
0.28
N
20.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
25
E
32
Vinyl
Low-E Double
Yes
0.79
0.28
N
20.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
26
W
33
Vinyl
Low-E Double
Yes
0.79
0.28
N
20.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
27
E
35
Vinyl
Low-E Double
Yes
0.79
0.28
N
10.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
28
E
37
Vinyl
Low-E Double
Yes
0.79
0.28
N
20.0 ftZ
2 ft 0 in
1 ft 4 in
None
None
29
S
38
Vinyl
Low-E Double
Yes
0.79
0.28
N
40.0 ftZ
5 ft 0 in
1 ft 3 in
None
None
30
S
38
Vinyl
Low-E Double
Yes
0.79
0.28
N
10.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
31
S
39
Vinyl
Low-E Double
Yes
0.79
0.28
N
10.0 ftZ
2 ft 0 in
1 ft 5 in
None
None
32
S
41
Vinyl
Low-E Double
Yes
0.79
0.28
N
40.0 ftZ
5 ft 0 in
1 ft 3 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ftZ
400 ftZ
loft
9 ft
19
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000319
3754.5 \ 206.12 387.63 .1875 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COP:1 34 kBtu/hr
COP:1 27 kBtu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR
Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER: 16 46.5 kBtu/hr 1590 cfm 0.85
Single SEER: 16 34.2 kBtu/hr 1026 cfm 0.85
1
2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 80 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
V #
--- Supply --
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handier TOT OUT QN
RLF
HVAC #
Heat Cool
1
2
Attic 6 250 ft2
Attic 6 250 ft2
Attic
Attic
65 ft2 Default Leakage Attic (Default) c(Default) c
65 ft2 Default Leakage Attic (Default) c(Default) c
1 1
2 2
TEMPERATURES
Programable Thermostat: Y
Heating H Jan H Feb HX Mar
Jan Feb Mar
Ceiling Fans:
Jun Jul Aug Sep Oct
Apr I i May lApr may XJun rl Jul rl Aug ri Sep Oct
Nov
txl Nov
Dec
H DecVenting
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66,
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
FLEX ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAU N D.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CABANA
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIR
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ELE
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRWAY
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 lbs/sq.ft.
ft2
ft
0.3
ELEVATOR
Default(8 Ibs/sq.ft.
ft2
ft
0.3-
BATH 4,
Default(8 Ibs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
A/C 2
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8lbs/sq.ft.
ft2
ft
0.3
MASTER SUITE
Default(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STARIWAY.
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/s .ft.
ft2
ft
0.3
OFFICE
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: TAYLOR RESIDENCE Builder Name: COASTAL CONSTRUCTION
Street: 5012 WATER SONG WAY Permit Office: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number:
Y
U
Owner: GREG TAYLOR Jurisdiction:
w
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be out neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilin s.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
2/12/2020 2:20 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
80.7
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
4494
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.857
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.305
14. Heating system: Capacity
61.0
c) Area
7c.
989.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
b) Wood, raised (R-value)
9b.
varies
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
9.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be install (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be complete d o nstalled code compliant features.
Builder Signature: Date:
Address of New Home: 5012 WATER SONG WAY City/FL Zip: ST. LUCIE COUNTY, FL
2/12/2020 2:20:11 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1