HomeMy WebLinkAboutFire Sprinkler PlanSPRINKLER PIPING PLAN 3rd FI.
SCALE: 3/16" = 1'-0"
OENERALNOTES
1.) ALL WORK TO CONFORM TO NFPAA SR AND LOCALAUTHOR171ES HAVING JURISDICTION.
23 SPRINKLER RISER PIPING TO BE WK ID WITH GROOVED ENDSAND GROOVED
FITTINGS.
30 ALL CONCEALED PIPING FEEDING ITS SHALL BE CPVC WITH SLIP FITTINSAND
RESIDENTIAL SPRINKLERS
4J ALLAREAS SHALL BESPRINKLED;
EXCEPTIOIi1 SPRNKLERS SHALLNOT BE REOLRREO IN BATHROOMS UNDER 55.RA
EXCEPNON-2SPRINKLERS SHALLNOT BE REWIRED IN OLD, LINEN CLO, OR PANTRIES
WITHIN THE DWELLING UNIT WHERE THEAREADOES NOT EXCEED 24ogR
EXCEPTIONSSPRINKLERS SHALLNOT SE REWWRED W ANY GARAGES PORCHES
BALCONIES, CORR.AND OR STARSTHATARE OPENANDATTACHED.
EXCEPTION4.SPRWKLERS SHALLNOT BE RECURRED MATTICS OR CRAWL SPACES
THATARE NOT USED OR INTENDED FOR LIVING PURPOSES.
5.) IVWGERS TO BE LISTED AND APPROVED TWO HOLE STRAPS FOR CPVC PIPING
SPRINKLER PIPING PLAN 2nd, Ff. SPRINKLER PIPING PLAN 1st FI
SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0"
eTTm
CIO
"I r
FIRE SPRINKLER PIPING PLAN AND DETAILS DATE: 4-12-19
JOB NUMBER: S116C19
DRAWN BY: Shelly Schuyler
SCALE: 3/16" = 1'-0"
Taylor Residence
(Lot 67 At Watersong)
5012 Watersong way,
Fort Pierce, FL 34949
CONCRETE DECK
HILT[PIN
CPVC PIPING \
PIPESTRAP
PER PIPE MANUFACTURES SPEC
TWO HOLE PIPE STRAP
N aM
REMOTEAREA#1
REMOTEAREANAME
RfAW@ftYF6PA-13D
DENSITY
0.0505PM8'BX(2HEADDES—D
TOTALHEADSFLOWING
2
K-FACTOR
4D
SYSTEM FLOW DEMAND
28.55
SYSTEM PRESSURE DEMAND
662J8
BASE"TRISER-GPM
25.35
BASE W RISER • PSI
6635E
SAFETYMARGIN-PSI
+836403.6%)
1' FlPW O TO EIUSTDID 6YST
� _�, NEW CEILPIO
VIKING CONCEALED SPRINKLER OR
• 52—TYCO 10, CONCEALED PENDENT SPRINKLER
SERIIES LFII WHITE PENDENT, K-4.2, 155 DEGREE
*41�bQ�actor
M
FIRE SPRINKLER
SHT. 1 OF 1