Loading...
HomeMy WebLinkAboutNOA; Series Clipped, Extruded Aluminium Tube MullionM IAM 1•DADE DEPARTMENT OF REGULATORY AND ECONOWC ur.SOURrr.R (RE..0 BOARD AND CODE ADMINISTRATION DM SION RECEIVED NOTICE OF ACCEPTANCE(NOA) CGI Windows and Doors, Inc. APR 2 6 9019 10100 NW 25' Street Miami, FL 33172 4T, WgIQ QwntY, FOXMItt.i MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 T (786) 315-2590 F (786) 315-2599 www.miamidade.g2y/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials: The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series Clipped, Extruded Aluminum Tube Mullion — L.M.I. APPROVAL DOCUMENT: Drawing No. M95-13A, titled "Series Clipped, Extruded Aluminum Tube Mullion — L.M.I.", sheets 1, 2, 3, 3.1, 4, 4.1, and 5 of 5, dated 11/25/95, with revision H dated 01/16/18, prepared by Al-Farooq Corporation, signed, sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Section Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA.shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 15-0420.08 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 18-0129.08 Expiration Date: March 28, 2023 Approval Date: March 29.2018 f-3 p1 % Page 1 CGI. Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 95-0929.39) 2. Drawing No. M95-13A, titled Series "Mullion Elevations and Details", sheets 1, 2, 3, 4, 4.1 and 5 of 5, dated 11/25/95, with revision G dated 07/27/15, prepared by Al- Farooq Corporation, signed, sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS. 201-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) ,Small Missile Impact Test per FBC, TAS 201-94 5) Large Missile Impact Test per FBC, TAS 201-94 along with marked -up drawings and installation diagram of casement windows mulled using a 1"x 2"x 1/8" aluminum tube mullion, prepared by Hurricane Testing Lab, Inc., Test Report No. HTL-0080-0105-08, dated 03/26/08 for Specimens No. 1 and 2, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 08-0331.07) 2. Test reports on: 1) Large Missile Impact Test, Loading per SFBC, PA 201-94 along with marked -up drawings and installation diagram of an aluminum fixed window, prepared by Hurricane Test Laboratory, Inc. Test Report No. HTL-0080-0303-96, dated 03/06/96, signed and sealed by Timothy S. Marshall, P.E. (Submitted under NOA No. 95-0929.39) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per SFBC, PA 202-94 along with marked -up drawings and installation diagram of fixed windows mulled using a 1"x 2"x 1/8" aluminum tube mullion, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-96-525, dated 02/12/96, signed and sealed by Hector M. Medina, P.E. (Submitted under NOA No. 95-0929.39) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 511 Edition (2014), dated 04/13/15 and 07/25/15, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 Manuef Per , P . Product Control Exa r NOA No. 18=012 .08 Expiration Date: March 28, 2023 Approval Date: March 29.2018 E-1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY -ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 51h Edition (2014), and of no financial interest, dated April 13, 2015, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Laboratory compliance letters for Test Report No.` HTL-0080-0105-08, specimens 1 and 2, issued by Hurricane Test Laboratory, Inc., dated 03/26/08, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 08-0331.07) 3. Laboratory compliance letters for Test Report No. HTL-0080-0303-96, issued by Hurricane Test Laboratory, Inc., dated 03/06/96, signed and sealed by Timothy S. Marshall, P.E. (Submitted under NOA No. 95-0929.39) 4. Laboratory compliance letters for Test Report No. HETI-96-525, issued by Hurricane Engineering & Testing, Inc., dated 02/12/96, signed and sealed by Hector M. "Medina, P.E. (Submitted under OA No. 95-0929.39) G. OTHERS 1. Notice of Acceptance No. 12-1220.15, issued to CGI Windows & Doors for their Series "Clipped" Aluminum Tube Mullion — L.M.I., approved on 02/28/13 and expiring on 03/28/18. ' Manuel rez, YE. Product,Contro x iner NOA No. 18-0129.08 Expiration Date: March 28, 2023 Approval Date: March 29.2018 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. M95-13A, titled Series Clipped, Extruded Aluminum Tube Mullion — L.M.I.", sheets 1, 2, 3, 3.1, 4, 4.1 and 5 of 5, dated 11/25/95, with revision H dated 01/16/18, prepared by Al-Farooq Corporation, signed, sealed by Javad Ahmad, P.E. B. TESTS 1. None C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition (2017), dated 10/04/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5th Edition (2014), with FBC 6th Edition (2017), and of no financial interest, dated October 4, 2017, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHERS 1. Notice of Acceptance No. 15-0420.08, issued to CGI Windows & Doors for their Series "Clipped" Aluminum Tube Mullion — L.M.I., approved on 08/13/15 and expiring on 03/28/18. Manuel Pe ez, P Product Control a er NOA No. 18- 29.08 Expiration Date: March 28, 2023 Approval Date: March 29.2018 E-3 1.0001 .125 125 2 G00 Ld Ix a .332 W\4 Sx = .332 IN\3 1X2 MULLION 6063-T6 r L000-^{�.125 F . 3.000 125 125 2.000 3' Imo---2.GGG—�I CLIP ANGLE 6063-T6 Ix - .8502 m\4 Sx = .6335 IN\3 Ix = 2.9762 01\4 Sx = 1.4881 m\3 1X3 MULLION 6063-T6 p l.GGG�I _[ 125 125 4.000 L L___j Ix = 2.0374 IN\4 Sx = 1.0187 IN\3 1X4 MULLION 6063-TB 2X4 MULLION 6063-T6 Ix = 8.2757 m\4 Sx 2.7586 IN\3 11^ � 53�'�U3' 'W' DIMENSION MULLION 'W — IN. 2' 1.688 3' 2.688 4' 3.688 6' 5.688 .715 1.875 125 LI k--4.000-i MULLION CLIP FOR 1 BY TUBES CGI-383 6063-TS MULLION CLIP FOR 2BY TUBES 2X6 MULLION CGI-395 6063-T6 6063-T6 6.000 Li I I 4--2.000--I MULLIONS CONTAINING TYPICAL GLAZING PRODUCTS HORIZONTAL OR VERTICAL SEE WINDOW OR DOOR APPROVAL FOR FASTENERS SIZES AND SPACING INSTRUCTIONS: USE CHARTS AND GRAPHS AS FOLLOWS. MULLION SYSTEM IS RATED FOR LARGE MISSILE IMPACT. AND CAN BE USED WITH ALL MIAMI-DADE COUNTY APPROVED IMPACT AND NON -IMPACT RESISTANT PRODUCTS. RECTANGULAR ALUMINUM TUBE MULLIONS USING MULLION PROPERTIES ONLY NOTES: THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). ALL GLAZING PRODUCTS USED WITH THESE MULLIONS MUST MEET THE APPLICABLE BUILDING CODE REQUIREMENTS LE: WIND LOAD, WATER INFILTRATION, FORCED ENTRY RESISTANCE, SAFEGUARDS ETC. 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE FTC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL STEP 1 DETERMINE DESIGN LOAD REQUIRED PER ASCE 7 FOR PARTICULAR OPENING. PRODUCEREVISED STEP 2 USE DADE COUNTY APPROVED GLAZING PRODUCTS MEETING ds—rWS'mg WM dw Fj.W ABOVE LOAD REQUIREMENTS. Builft a /p STEP 3 USE CONNECTION M MULLION AS PER PRODUCT AO?P�+e°NeIO' Df •08 APPROVAL ration Dme 6+�1.� USING GRAPHS ON SHEET 2 SELECT MULLION SIZE WITH By .s 4 DESIGN RATING MORE THAN DESIGN LOAD SPECIFIED Miami ade prodacL C oaf IN STEP 1 ABOVE USING ANCHOR TYPES ON SHEETS 4 & 5. AND ANCHOR GRAPHS STEP 5 ON SHEETS 3 & 3.1. SELECT ANCHOR TYPE WTIN DESIGN RATING MORE THAN THE DESIGN LOADS SPECIFIED IN STEP 1 ABOVE. Z n n O q H2W 2N 9a 5� o°ry` WH 0 ul) 0ouim w � a o o pd8p O oti D 0 LL i u) Q W CMii N \ 2018 ? ' c� F (y; drawing no. M95-13A 1301 ON X 2 X 1/8- MULLION 1 X 3 X 1/8' MULLION ON 1 X 4 X 1/8' MUMULLIONV ;4 120 123 120 —VERTICAL 1�In Z n zo g 110 Aa 110 110 ' a p e 100 100 1DO 56• 50-5/ MULL SPAN ¢ o 1: Ogg O N 4 4 38-3 'MULL AN LL 63' Wt 1 W2 I �'j (L 90 a 90 a 90 OO I I 50-5/8' MULL SP I 0 0 a o a G G p 80 p BO o p 80 ARCHES TO BE ULAR SHAPE INSIDE RECTANGULAR SHAPE O In Lo¢ J z J z 56' J z 74-1/ ' �ZO N Q Lu :I") i� m 0 W 70 a w 70 2 70 HORIZONTAL MUWON W _ o .I 0 m o 60 c 60 63' 60 J Q�im�k' O I o 50 50 50 C 56' 40 40 84' 40 00 F 63' 108' 0 Of ? LL 30 25 35 45 55 65 75 85 30 25 35 45 55 65 75 85 25 35 45 55 65 75 85 I MUWON SPAN I a .� C TRIBUTARY WIDTH - INCHES- TRIBUTARY WIDTH - INCHES TRIBUTARY WIDTH - INCHES H n o 'o e1 2 X 4 X 1/8" MULLION 2 X 6 X 1/8' MULLION TYPICAL MULLION ARRANGEMENTS 3M 130 13o a c_ z� 50-5 B' WIDTH (W) = wt + wz N o 120 120 2 U 56' 74-1 4' in 0 110 110 100 100 4 74-1/4 MULLS c 0 € € n a90 a90 -wW3wwgR I I UUa �• MULLONS m Q1iizo pBO p80 J J 1�• U n 70 U 70 NOIE: MULLIONS RATED IN THESE CHARTS MAY BE ORIENTED 120' VERTICALLY OR HORIZONTALLY. (INTERPOLATION BETWEEN WIDTHS ALLOWED) 60 60 e.� • ��i i �' 50 50 ,.•� 3 o 10' 144' � � .: 40 40 PRODCFFREVISM ��NYe1H wd0 tln Fl�ida . 120• Boding cow JAN 2019 132' 30 25 35 45 55 65 75 BS 30 25 35 45 55 65 75 85 'eatioa Date. �/� � •. OF Qg� BY '�i IDp'' (•9�� /i/SS/o drawing no. M95-13A TRIBUTARY WIDTH - INCHES TRIBUTARY WIDTH - INCHES MULLIONS °dePr°ducL �`�� of 5 1/111111t1� sheet 2 MULLION z GLAZING GLAZING 3 PRODUCT PRODUCE � "CUBING PRODUCT 3 GLAZING GLAZING PRODUCT PRODUCT 130 120 110 100 rn n. 90 I 0 80 J z y 70 W C) 60 50 40 30 2 ANCHORS TYPE 'A' 2 ANCHORS TYPE 'B' 2 ANCHORS TYPE 'BH' 130 120 110 100 W EL 90 a 80 0 N70 O 60 50 40 30 25 35 45 55 65 75 85 25 35 45 55 65 75 85 25 35 45 55 65 75 85 TRIBUTARY WIDTH - INCHES TRIBUTARY WIDTH - INCHES TRIBUTARY WIDTH - INCHES 2 ANCHORS TYPE 'BF' 130 2 ANCHORS TYPE 'C' 120 110 100 N a 90 I 0 80 J z 2 70 N W O 60 50 40 30 Jau 120 110 100 W IL 90 I 0 80 J �a70 i 60 50 40 30 CUP r ' ANCHORS �y VEHNCAL MULLION z 0 GLAZING PRODUCT GLAZNG PRODUCT Z C F M N q N z 0 3 "-�CuP O t'w m LL ANCHORS () > d� Wi W2 a C C 0,o paooS HORIZONTAL MUWON CLIP ANCHORS O b ARCHES TO BE INSCRIBED INSIDE RECTANGULAR SHAPE a C Z N LL Z W LL CLA2INo / PRODUCT 3 ANCHOR '-DETAIL /1 3 GLAZING GLAZING PRODUCT PRODUCT CUP ANCHORS MULLION SPAN TYPICAL MULLION ARRANGEMENTS WIDTH (W) 2 ANCHORS 'A' APPLICABLE TO ANCHORS INTO 2BY WOOD BUCKS OR WOOD STRUCTURES OR THRU 1BY WOOD BUCKS INTO CONCRETE ANCHORS 'B' APPLICABLE TO ANCHORS INTO CONCRETE ANCHORS 'BH' APPLICABLE TO ANCHORS DIRECTLY TO HOLLOW BLOCKS OR-THRU 1BY WOOD BUCKS INTO BLOCKS APPLICABLE TO ANCHORS DIRECTLY TO GROUT FILLED BLOCKS OR THRU 1BY WOOD BUCKS INTO BLOCKS ANCHORS 'C' APPLICABLE TO ANCHORS DIRECTLY TO METAL STRUCTURES 25 35 45 55 65 75 85 25 35 45 55 65 75 85 PRODUCTR8V15FD TRIBUTARY WIDTH — INCHES TRIBUTARY WIDTH — INCHES as wmplying wi,h tbn Florida NOTE, Am t-mI4or6-0r24. ANY ANCHOR CONDITION SHOWN HEREIN MAY COVER ANCHOR LOAD CHARTS Dffie LOCATIONS AT HEAD, SILL OR JAMB ENDS. i FORANCHOR DETAILS AND DESCRIPTION SEE SHEETS 4 THRU 5. 2 ANCHORS AT MULLION ENDS m`Prad`N (INTERPOLATION BETWEEN WIDTHS OR SPANS ALLOWED) ' Q ' OF Rf drawing no. sue: 10M95-13A 4 ANCHORS TYPE 'A' 120 10 100 90 80 70 60 50 40 'An 25 35 45 55 65 75 85 TRIBUTARY WIDTH - INCHES 4 ANCHORS TYPE 'BF' 130 120 110 100 eL a 90 c z 80 Lo w 70 0 60 50 40 30 130 4 ANCHORS TYPE 'B' 4 ANCHORS TYPE 'BH' 38 120 50-5 B. 110 58' 100 m 4" 90 n 90 1 74 1/ p 80 J z 08 W 70 12 w 0 13 ' 101 PAN 60 50 40 30 25 35 45 55 65 75 85 TRIBUTARY WIDTH - INCHES 4 ANCHORS TYPE 'C' 130 120 110 100 w a 90 0 0 80 70 w 0 60 50 40 30 1 U) a, I o' J z c� 0 25 35 45 55 65 75 85 TRIBUTARY WIDTH - INCHES CUP C ANCHORS VERTICAL MULLION z 0 GLAZING PRODUCT GLAZING PRODUCT Z �n O� b� m F q n ¢co"R N I CLIP Ott; n Ir I ANCHORS Q � �{ l W, -II W2 a O K p aco a HORIZONTAL MULLION CLIP ANCHORS p U4 b � d D(n INSIDE6RECTANG! AR SHAPE C W ' GLAZING jaw Q WO�f PRODUCT 3 ANCHOR ETNL dt a 3 GLAZING GLAZING CL� PRODUCT PRODUCT ANCHORS I_ MULLION SPAN TYPICAL MULLION ARRANGEMENTS WIDTH (W) = 2 ANCHORS 'A' APPLICABLE TO ANCHORS INTO 2BY WOOD BUCKS OR WOOD STRUCTURES OR THRU 1BY WOOD BUCKS INTO CONCRETE ANCHORS 'B' APPLICABLE TO ANCHORS INTO CONCRETE ANCHORS 'BH' APPLICABLE TO ANCHORS DIRECTLY TO HOLLOW BLOCKS OR THRU 1BY WOOD BUCKS INTO BLOCKS ANCHORS 'BF' APPLICABLE TO ANCHORS DIRECTLY TO GROUT FlLLED BLOCKS OR THRU 19Y WOOD BUCKS INTO BLOCKS ANCHORS 'C' APPLICABLE TO ANCHORS DIRECTLY TO METAL STRUCTURES 25 35 45 55 65 75 85 25 35 45 55 65 75 85 PRODUC' TRIBUTARY WIDTH - INCHES TRIBUTARY WIDTH - INCHES av camNSmMwith The Flateda NOTE AmcapmaceNu 1 ANY ANCHOR CONDITION SHOWN HEREIN MAY COVER ANCHOR LOAD CHARTS kwim Dam LOCATIONS AT HEAD, SILL OR JAMB ENDS. By FOR ANCHOR DETAILS AND DESCRIPTION SEE SHEETS 4 THRU 5. 4 ANCHORS AT MULLION ENDS Mi=i ad. 'ad (INTERPOLATION BETWEEN WIDTHS OR SPANS ALLOWED) = C � g N E O0 r n l'i p La I E O M n a C Z t' u 0- ` CE11S -• ;®'ice i . 0 OF Qg�� drawing no. -13AII • 3/4" 0 ULTRACON 1/ ANGLE 2x2x 1/8• ,'�... ALUM ANGLE - 14 S.M.S. 2/ ANGLE [MULLION 1BY OR 2BY WOOD BUCK MULLION d' 2x2x1/8- ALUM ANGLE 2-5/8' LONG I I < d i I I I I�2E I�� I I - . ' 1.500 Lm. 2 SCREWS PER SIDE REQUIRED FOR 3' TUBE MULLIONS CUP ANGLE ATTACHMENTS NOT APPLICABLE FOR 1"X2" TUBE MULL 2x2x 1/8• i ALUM ANGLE I I I 1 fi14 S.M.S. ____________1 2 2/ ANGLE I1 2' MIN. 1� I II I� NOTCH ANG II MISS MARBI 0 11 1 OR TRIM uoi, � li 11 :: "PRECAST CONCH • SILL' a ,/4• DIA. ULTRACON ,/ ANGLE •1/4" 0 ULTRACON 2 X 2 X 1/8• 2/ ANGLE ALUM ANGLE a 8 14 S.M.S. 2/ ANGLE - _ -MUWON 16Y OR 2BY MULLION WOOD BUCK 2x2x 1/8- ALUM ANGLE 2-5/8" LONG ----------- 2! d l03 z 441 I p . I 1.500 MAX. ' •d 2 SCREWS PER SIDE REQUIRED FOR 3" TUBE MULLIONS CUP ANGLE ATTACHMENTS NOT APPLICABLE FOR 1"X2" TUBE MULL IIBTCII VODD DUCK .To ACCOMODATE Ll •CLIP.ANGLE TO MASONRY 1/8- 2x2x 1. . . ALUM ANGLE 8 14 S.M.S. _ - - .' 1/4' 0 ULTRACON 3/ ANGLE 2/ ANGLE MULLION -d •a CONCRETE OR NASONRY BLOCKS MULLION 2 X 2 X 1/B" ALUM ANGLE 3-5/8' LONG I I I I I .. to 0 .O I . I I I I I - I 1.sao '.°•a'. MAx. 3 SCREWS PER SIDE REQUIRED FOR 4" & 6" TUBE MULLIONS PRODUCT REVISED as ee-*Ying with die Fk" Building Code ,,, �4ftI Z q r Z O U O q N 0o0 a 0t Om 0 W o. a oot2 N Q W0J 7 LL i0 2 N g?l7 da Q W W 2 F N I m C n � N N of 0 E O = p Lu E 4 a= -0 c' c 9rwe 3N_e M O M n Z • f�{ O I A OF ly�� drawing no. M95-13A II 4/4" 0 ULTRACON 1/ ANGLE °d°.1 4' 0 ULTRACON TO CIfAC VOOD BUCK . I / ,TO ACCONODATE MULLION MULLION CUP 2/ ANGLE •CLI-;ANGLE TO MASONRY Z m z ° O 0 qw 3 —e— — ¢°S' �G 0 e --- 0 s d a I o .° ____ �—_____ 1� e 0 U TRACON o 0 t V�li u O O p 0.00 �— — 0��� i� MUWONQ MUWONa •, j Z00��CONCRETE OR QWTfMASONRY BLOCKSY OR 2BY 1BY OR 20Y OD BUCK WOW BUCK°', MULLION I V m C m MULLION a 0 n ° ° °e .. E 0 w .. Ii '= 1---- rT----- 'E I I I I Y 4 I I — �_ _ •0 � U II a G I I 'E 0�cj I I _ I I Z I I Ntn� N II II o II o O a o CZJ� --___ :4 II n 0 o • U n O • - 1 .e 4 o rc o o MUWON I m I I 1 1 1 1 SEE SHEET 1 FOR APPLICABLE MULLION CUP TO j j 1BY OR 2BY TUBE MULLIONS 4 0 r--------------�i AND FOR FABRICATION OPTIONS OF MULLION CLIPS ` a � II 11 NOTCH CUPS TO ` 11111 I111/T Y II 11 MISS MARBLE SILL jl II OR TRIM \\`\~J •• '���i 1 •� PRODUcr RBVTSCD O 0592 I 4. as cemdYiflB with the I'rloti0at BuildiOBCod'e 18-0149 0 ; j' 2 2010 F cttplaoen W =Edrawing no.RECAST CONCH n8 I B !20R10�•.•' \�LL'0�. � e ,/a• DIA ULTRACON ryti Dade Product ''%�S .... ���?\•� M95-13A 1/ ANGLE YAT/���0�1,\\`\ sheet4.tof 5 0 WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING TYPE 'A'- 1/4' DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONCRETE 1-1/4" MIN. EMBED, INTO CONCRETE TYPE 'B'- 1/4- DIA, ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) DIRECTLY INTO CONCRETE 1-1/2" MIN. EMBED INTO CONCRETE TYPE 'BH'- 1/4" DIA. ULTRACON BY 'ELCO' (Fu-177 KSI, Fy=155 KSI) DIRECTLY INTO HOLLOW BLOCKS 1-1/4" MIN. EMBED INTO BLOCKS THRU 1BY BUCKS INTO BLOCKS 171/4" MIN. EMBED INTO BLOCKS TYPE 'BF'- 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) DIRECTLY INTO FILLED BLOCKS 1-3/4" MIN. EMBED INTO BLOCKS THRU 1BY BUCKS INTO BLOCKS 1-1/4' MIN. EMBED INTO BLOCKS TYPE 'C'- 914 SMS ORSELF-DRILLING SCREWS (GRADE 2 CRS) INTO METAL STRUCTURES (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO CONCRETE AND BLOCKS = 2-1/2" MIN. INTO WOOD STRUCTURE = 1' MIN. INTO METAL STRUCTURE = 1/2" MIN. WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c - 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS Pm - 2000 PSI MIN. Z q� a 46 O W .0 OR �N ITC w c ul) v p uT'1 ACCESS HOLE a o Z c 2 OR 4 ANCHORS TYPE 'C' f G a O a „0�+, SEE SHEETS 3 & 3.1 METAL STRUCTUREOR Q qJ+ 33 FOR CAPACITY TUBE MULLION Q Z N ------------------------- u uZlU) m o Q wmf ----------------------- ---- N � THIS SCREW CAN BE I I ff14 % 3/4 FH SMS a N N m INSTALLED IN EfTHER I 1 1 PER CUP AT 1X2 & 1X3 MULLION DIRECTION 5jp I 2 PER CLIP AT LARGER MULLIONS r= = Q v 0 w I p W a MULLION I r(n a = N o 1/8' THICK ALUM CHANNEL I 1BY OR 2BY TUBE r n LENGTH TO FIT SNUG I j N N INTO MULLIONI 3 I i V 3 ,n d cz� N a Z3 3o 0 O�v ANCHORS DETAIL #1 4 oa METAL TO METAL CONNECTION N tJ PRODUCFREVL4FD m cemply6g with the F6mida 130dinSCode 1A s j__ 2018 E ��(y�� drawing no. 1IM95-13A P.'�°,.�