HomeMy WebLinkAboutEnergy CodeFORM R405-2017 tFLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method 1' Project Name: MAUI_CUSTOM _ STILLER _2020 Builder Name: PORT ST LUCIE PROPERTIES Street: 000 GULLOTTI Permit Office: City, State, Zip: FORT PIERCE, FL, 34952 Permit Number. Owner: Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2206.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1984.10 ft2 b. Frame - Wood, Adjacent R=11.0 311.89 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (2155.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Roof Deck (Unvented) R=20.0 2155.00 ft2 6. Conditioned floor area above grade (ft2) 2155 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(157.3 sqft.) Description Area a. Sup: Main, Ret: Main, AH: Garage 6 431 a. U-Factor: Dbl, U=0.58 79.78 ft2 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.62 45.50 ft2 12. Cooling systems kBEfficiency SHGC: SHGC=0.22 a. Central Unit 23.6 23.6 SEER:16.00 c. U-Factor: Dbl, U=0.65 24.00 ft2 SHGC: SHGC=0.21 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 8.00 ft2 a. Electric Strip Heat 34.0 COP:31.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 2.739 ft. Area Weighted Average SHGC: 0.231 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2155.0 sqft.) Insulation Area EF: 0.930 a. Slab -On -Grade Edge Insulation R=0.0 2155.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.073 Total Proposed Modified Loads: 72.18 PASS Total Baseline Loads: 73.36 1 hereby certify that the plans and specifications covered by Review of the plans and'fH� ST.gp, this calculation are in compliance with the Florida Ener specifications covered by this ' A0 '_ Code. MECHANICAL calculation indicates compliance - y`� �i, ��� Air Conditioning Corp. with the Florida Energy Code. 1►ru"-:.'r- �';•� �� O V. PREPARED BY: Before construction is completed r DATE: 1/12/202-0 this building will be inspected for compliance with Section 553.908 * ° hereby certify that this building, as si is in mplian Florida Statutes. with the Florida Energy Code. OoD y�rg'i¢� OWNER/ T. BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than`6.00 ACHH50 VIN®FOR FILE C01)v (CODE COMPLIANCE ST, LUCIE COUNTY 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20Qot Software Page 1 of 5 FORM RdnF-9nl7 INPUT SIIMMARY CHECKLIST RFP0RT PROJECT Title: .: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Odsting: Comment: MAUI_CUSTOM_STILLER_2 User 1 PORT ST LUCIE PROPERTI Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 2155 Total Stories: 1 Worst Case: Yes Rotate Angle: 180 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook:- Street: 000. GULLOTTI County` St. Lucie City, State, Zip: FORT PIERCE, FL, 34952 CLIMATE Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp :Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name. Area Volume 1 Blockl 2155 20257 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2155 20257 Yes 6 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 244It 0 2155 ft2 — 0.5 0 0.5 ROOF V # Type Materials Roof Gable Roof Area Area Color Rad Solar SA Emiti Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2410 ft2 0 ft2 Unfinishe N 0.96 No 0.4 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2155 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area. Framing Frac . Truss Type 1 Under Attic (Unvented) Main 0 Blown 2155 ft2 0.11 Wood 01%12/2020 3:55 PM EnergyGaugeO USA 6.0.02 (Rev. 1)-.FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 Fr1RIU RdnS_7nl7 IAIPI IT Al IMMARV CI-IFCKIIRT RFPf)RT . WALLS' Adjacent Cavity Width Height Sheathing Framing Solar Below Spate i 1 W=>E Exterior Concrete Block - Int Insul Main 4.0999 20 3 9 4 189.0 ft2 0 0.5 0 2 N=>S Exterior Concrete Block- Int Insul Main 4.0999 8 9 4 74.7 ft2 0 0.5. 0 3 W=>E Exterior Concrete Block - Int Insul Main 4.0999 17 7 9 4 164.1 ft2 0 0.5 0 4 S=>N Exterior Concrete Block - Int Insul Main 4.0999 8 9 4 74.7 ft2 0 0.5 0 5 W=>E Exterior Concrete Block - Int Insul Main 4.1 22 2 9 4 206.9 ft2 0 0.5 0 6 N=>S Exterior Concrete Block - Int Insul Main 4.0999 54 9 9 4 511.0 ft2 0 0.5 0 7 E=>W Exterior Concrete Block - Int Insul Main 4.1 22 2 9 4 206.9 ft2 0 0.5 0 8 S=>N Exterior Concrete Block - Int Insul Main 4.0999 18 3 9 4 170.3 ft2 0 0.5 0 9 E=>W Exterior Concrete Block - Int Insul Main 4.0909 17 37 9 4 187.4 ft2 0 0.5 0 10 N=>S Garage Frame - Wood Main 11 33 5 9 4 311.9 ft2 0.2 0.5 0 11 S=>N Exterior Concrete Block - Int Insul . Main 4.0999 21 4 9 4 199.1 ft2 0 0.5 0 I DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 N=>S Insulated Main None A6 5 6 8 33.3 ft2 2 E=>W Insulated Main None A6 2 8 6 8 17.8 ft2 3 S=>N Insulated Main None A6 3 8 24 ft2 4 E=>W Insulated Main None A6 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>E 1 Metal Double (Tinted) Yes 0.58 0.24 N 19.8 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 2 W=>E 1 Metal Double (Tinted) Yes 0.58 0.24 N 6.7 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 3 W=>E 3 Metal Double (Tinted) Yes 0.65 0.21 N 24.0 ft2 8 ft 0 in 1 ft 0 in None Exterior 5 4 W=>E 5 Metal Double (Tinted) Yes 0.58 0.24 N 39.6 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 5 N=>S 6 Metal Double (Tinted) Yes 0.58 0.24 N 6.9 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 6 N=>S 6 Metal Double (tinted) Yes 0.58 0.24 N 6.9 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 7 E=>W 7 Metal Double (Tinted) Yes 0.62 0.22 N 22.8 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 8 E=>W 9 Metal Double (tinted) Yes 0.62 0.22 N 22.8 ft2 4 ft 7 in 1 ft 0 in None Exterior 5 9 E=>W 9 Metal Single (Clear) Yes 0.45 0.26 N U ft2 4 ft 0 in 2 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 64 ft 9.4 ft 1 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - F16Res2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 PnRM PAn.F_gn17 INPIIT SUMMARY CHECKLIST REPnRT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000358 2025.7. 111.21 209.14 .1326 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:31 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype . Efficiency Capacity Air Flow SHR .. 'Block Ducts 1 Central Unit/ None Singl SEER: 16 23.6. kBtu/hr 708 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 40.gal. 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS — Supply — V # Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Main 6 431 ft' Main 47.6 ft' Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb Mar HeatinJan Feb Mar Ventin Jan Feb X Mar Ceiling Fans: Apt May Jun JXJJul Au Se Oct [ Nov f Apr f May ri Jun Jul rl Aurl Sep Oct [XNov [X] A r [ Ma Jun Jul: Aug Se [xl Oct [X Nov Dec XDec [ Dec 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80 .. PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz O,ft 0.3. Main 01/12/2020 3:56 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD .. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R - 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 23.6 a) Split system SEER 5. Is this a worst case? (yes/no) 5. Yes b) Single package - SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2155 d) Room unit/PTAC EER e) Other 16.0 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.596 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.231 14. Heating system: Capacity 34.0 c) Area 7c. 157.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 31.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 1.5. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0:93 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 1082. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. . No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed ba on' stalled cod mpliant features. BuilderSignatur : Date: 24 ZO Address of New Home: 000 GULLOTTI City/FL Zip: FORT PIERCE, FL 34952 01/12/2020 3:55:32 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 000 GULLOTTI Permit Number: FORT PIERCE, FL, 34952 MANDATORY REQUIREMENTS See individual code sections for full details. V SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory).The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveldiom building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakagdNindows, skylights and'sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no.more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any,water lines and ducts in the room insulated in accordance with Section R403. The combustion airduct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessedluminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall. be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(% (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufi air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure: Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105"F (41 "C) or - below 55"F (13"C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe ❑ shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 .MANDATORY REQUIREMENTS - (Continued) 11403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Y2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140OF (38°C to 60°C). El R403.5.6.1..2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be tumed off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1: Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, -shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFMNVATT) AIRFLOW RATE MAXIMUIV (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 01/12/2020 3:55 PM EnergyGauge® USA 6.0,02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS = (Continued) ❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor -design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section. R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimumperformance during base load periods is utilized. El and Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or extemal to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatoryke energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel.gas lighting systems shall not have continuously burning pilot lights. 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MAUI_CUSTOM_STILLER_2020 Builder Name: PORT ST LUCIE PROPERTIES Street: 000 GULLOTTI Permit Office: City, State, Zip: FORT PIERCE, FL, 34952 Permit Number: - Y U Owner: Jurisdiction: W Design Location: FL, ST LUCIE CO_INTL U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. _ Air-p ermeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or:joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The, junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between Wndow/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top. side fl_ oors) of sheathing, or continuous insulation installed on the underside of floor -framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall. be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts, penetrations Duct'shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit; or narrow Narrow cavities cavities shall be filled by insulation that.on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC, rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend hind pioing Shower/tub The air barrier installed at exterior walls adjacent to.shower s and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air.barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to.be sealed, concealed fire. sprinklers shall only be , sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids firrinkler yr Mates and walls a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 01/12/2020 3:55 PM EnergyGauge® USA 6.0.02 (Rev. I):. FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower poor Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: Job Information Builder: PORT ST LUCIE PROPERTIEGommunity: Lot: NA. Address: 000 GULLOTTI City: FORT PIERCE State: FL Zip: 34952 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. O PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specked on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): 6.000 x 60 _ 20257 - Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans F-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/tCC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as_ set forth in Section 489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official Testing. shall be performed at any fime after creation. of all penetrations of the Building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be dosed; but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and;flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and, sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name- Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 01/12/2020 3:55.49 PM EnergyGaugee USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Certificate of Product Ratings AHRI Certified Reference Number: 201785534 Date : 01-08 22020 Model Status: Active AHRI Type: RCU-A-CB Series: GSX16 Outdoor Unit Brand .Name: GOODMAN Outdoor Unit Model Number (Condenser or Single Package) : GSX16S361A* Indoor Unit Model Number (Evaporator and/or Air Handler) : ASPT47D14A` Region: Southeast and North (AL, AR, DC, DE, FL, GA, HI; KY, IA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured priorto January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this GOODMAN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of,ANSI/AHRI 210/240 with Addenda 1 and 2, Performance Rating of Unitary I i 1\ � . L . I '—L' ' I / n f�l n , AIr Conditionings&.Ai�r-Sourrcef H'66t-Pumpan rsubjlect to rating accuracy by AN ponsoreitindependent, ttn�d,partytesting: ', 01 p .� I Coaling Capaci�A2) - Sin1 gle ar High (95F)1 btuh � 35000 L SEER � 16.U0 1 ' �_ LLii EER .(A2) - Single,or High Stage (95F) : 13.00 t"Active" Model Status are those that an AHRI Certification Program. Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced "Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re -rate. The new published rafino is shown along with the previous (i.e. WAS) ratinq. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory atwww.ahrid ifectory.org. ' TERMS AND CONDITIONS This Certificate and Its contents are propHetary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or In part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual', personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information forthe model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which Is listed at bottom right. ©2020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 1322297311895345232 Load Short Form Job: Date: 1 /12/20 • • �, #1 House BY: MECHANICAL A/C Plan: MAUI CUSTOM 1373 N. KILLIAN DR., LAKE PARK, FL 33403 Email: WM MECHANICALAC.COM Web: LIC- CAC1816081 iLroject intormation For: MAUI_CUSTOM- STILLER, PORT ST LUCIE PROPERTIES 000 GULLOTTI, PORT ST LUCIE, FL 34952 Htg Clg Infiltration Outside db (°F) 41 91 Method Simplified Inside db (°F) 70 74 Construction quality Semi -loose Design TD (°F) 29 17 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/Ib) 2 56 HEATING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Model HKSC10XC AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 10.0 kW 34121 Btuh 26 °F 1200 cfm 0.041 cfm/Btuh 0.50 in H2O COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX16S361A Coil ASPT47D14A AHRI ref 201785534 Efficiency 13.0 EER, 16 SEER Sensible cooling 27650 Btuh Latent cooling 7350 Btuh Total cooling 35000 Btuh Actual air flow: 1200 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.79 ROOM NAME Area (ft2) Htg load (Btuh) Cig load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MB 82 1476 1023 60 46 MC 27 712 388 29 18 MBR 224 3333 3156 136 143 KITCHEN 147 1701 2802 70 127 LIVING 347 2562 3257 105 148 LAU N 39 385 767 16 35 FOYER 62 1529 902 63 41 BDRM 3 146 2155 2155 88 98 BDRM2 152 3477 2367 142 108 LEISURE 238 1576 2739 64 124 BTH2 52 892 500 36 23 MBR2 152 3716 2339 154 106 Room3 M] I_In 81 n_n 2217 AAn 778 AnA 91 nn 35 An Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. k * wrightsof#a zo2a lan-12 14:42:04 w .. =n ,,.,d.....,.d,.9 Right -suite® Universal 2019 19.0.12 RSU08764 Page l '�'rCh ... s1CUSTOM MODELSWAUI_GL CUSTOM_STILLER_2020.rup Calc = MJ8 Front Door faces: N LA Lti 00 4L L L P2 30 59 46 2 2 LR2 179 2508 2732 103 124 Room20 77 0 0 0 0 #1 House 2131 29355 26413 1200 1200 Other equip loads 0 0 Equip. @ 1.60 RSM 26413 Latent cooling 6843 T Al n I IY4n4 I Ar17LG I nnncG 1 4/IAA 1 411 r% V I ALV G IJ 1 LJVVV VVLVVILVV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr-ightsofr 2020•Jan-1214:42:04 .w,•,�.w,,..,,,a,,q Right -Suite® Universal 201919.0.12RSUo8764 Page ...sICUSTOM MODELSIMAUI_GL_CUSTOM _STILLER _2020.rup Calc= MJ8 Front Doorfaces: N Project Summary Job: #1 House Date: 1/12/20 By: MECHANICAL A/C Plan: MAUI CUSTOM 1373 N. KILLIAN DR., LAKE PARK, FL 33403 Email: WWW.MECHANICALAC.COM Web: LIC- CAC1816081 For: MAUI CUSTOM- STILLER, PORT ST LUCIE PROPERTIES 000 GULLOTTI, PORT ST LUCIE, FL 34952 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Outside db 41 °F Inside db 70 °F Design TD 29 °F Heating Summary Structure 24752 Btuh Ducts 4604 Btuh Central. vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 29355 Btuh Infiltration Method Simplified Construction quality Semi -loose Fireplaces 0 Heating Cooling Area (ft� 2131 2131 Volume (ft?) 20009 20009 Air changes/hour 0.49 0.25 Equiv. AVF (cfm) 163 83 Heating Equipment Summary Make Goodman Mfg. Trade GOODMAN Model HKSC10XC AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure_ Space thermostat 100 EFF 10.0 kW 34121 Btuh 26 °F 1200 cfm 0.041 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db 91 °F Inside db 74 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 56 gr/lb Sensible Cooling Equipment Load Sizing Structure 23406 Btuh Ducts 3007 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Btuh Equipment sensible load 26413 Latent Cooling Equipment Load Sizing Structure 4757 Btuh Ducts 2086 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6843 Btuh Equipment Total Load (Sen+Lat) 33255 Btuh Req. total capacity at 0.79 SHR 2.8 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN. Cond GSX16S361A Coil ASPT47D14A AHRI ref 201785534 Efficiency 13.0 EER, 16 SEER Sensible cooling 27650 Btuh Latent cooling 7350 Btuh Total cooling 35000 Btuh Actual air flow 1200 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J.8th Ed. wr1ghtsuft' 2020-Jan-1214:42:04 Right-Suite® Universal 2019 19.0.12 RSU08164 Pagel ... s1CUSTOMMODELSWAUI_GL CUSTOM_STILLER 2020.rup Calc=MJ8 FrontDoorfaces: N Manual S Compliance Report Job: Date: 1112120 • ;:. #1 House By: MECHANICAL A/C Plan: MAUI CUSTOM 1373 N. KILLIAN DR., LAKE PARK, FL 33403 Email: WVWV.MECHANICALAC.COM Web: LIC- CAG1816081 For: MAUI_CUSTOM- STILLER, PORT ST LUCIE PROPERTIES 000 GULLOTTI, PORT ST LUCIE, FL 34952 Design Conditions Outdoor design DB: 91.2°F Sensible gain: 26413 Btuh Outdoor design WB: 77.1 `F Latent gain: 6843 Btuh Indoor design DB: 74.0°F Total gain: 33255 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Goodman Mfg. Model: GSX16S361A+ASPT47D14A Actual airflow: 1200 cfm Sensible capacity: 29853 Btuh 113% of load Latent capacity: 4964 Btuh 73% of load Total capacity: 34817 Btuh 105% of load SHR: 86% Design Conditions Outdoor design DB: 41.0°F Heat loss: 29355 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Elec strip Manufacturer: Goodman Mfg. Model: HKSC10XC Actual airflow: 1200 cfm Output capacity: 10.0 kW 116% of Load Meets all requirements of ACCA Manual S. Entering coil DB: 74.1°F Entering coil WB: 62.1°F Entering coil DB: 69.8°F Temp. rise: 26 °F 2020-Jan-12 14:42:04 .,,.u.�......,aa.o.� Right-Suite®Universal 2019 19.0.12 RSU08764 Page 1 AM ...s1CUSTOM MODELSXMAUI GL CUSTOM_STILLER 2020.rbp Calc=MJ8 Front Door faces: N To the bad of my kno" Ih"a Am; ark mmw do samdy kith 01 app W* vodka. & 2017 Fk2 Buidng OW Pftr al Energy ocieu k hmm done u; ng E mV Gouge- ndzmm16 A: FSg�t J# Right-.* p the arbTated vmion of the Eth m on .of the: AMA Monad J. Right-.lp eamputr9 the saes of heating and ending design bads and is thus Laed iw ismng reichmitid HYAC equp m' auct 01dom ugbg KV-[II Right- 0 is the nicrommputw wmian of tfr 9eeond effm of the AMA k6id a for Rotd*dkl duct dm im. Thm Plana anparaeda and void all preyiouc pions and 'qw6fimiiiore. Duct A V1W Iwor m may dwo dui to a*nerj9 request or Amaturd iniiaticxi�. IN3 ARE Atf1�LTXl AST k VAS $WX PRESSURE OF HVIC S Job #: Performed for: MAULCUSTOM- 000 GULLOTTI PORT ST LUCIE, FL 34952 HVAC NOTES Ca 006M =I M FW" N9 FEE—,M M.Q.A.-1646 VOLT 130 AIR HAI` -M— A`iPT4-V4A O�t SP� -1 � .6 yl7�LT-7.3� I4EAT-1W .0 A- 541.5 Ox FLI.SE- 50 SM RMV-16 AM REF.- 2017MU "fl-EROWT- HOIf*1 -M / VIiF FU U4ES— 7/0 / 3/8 f VhL C*RLES OTH FOC OECH .301.12 MECHANICAL A/C 1373 N. KILLIAN DR. LAKE PARK, FL 33403 LIC- CAC1816081 WWW.MECHANICALAC.COM m4rpw* 1a am* Scale: 1 : 48 Page 1 R ght Sui teO Universal 2019 19.0.12 RSU08764 2020-Jan-12 14:45:01 ... 1NIAUI GL CUSTOM STILLER 20: