Loading...
HomeMy WebLinkAboutAPPROVED, NOA Fiber Glass Door_ FL22378-R7BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL22378-R7 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago, IL 60185 (800) 663-3667 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard)Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 11/05/2020 Date Validated 11/05/2020 Date Pending FBC Approval Date Approved 11/11/2020 Summary of Products FL #Model, Number or Name Description 22378.1 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Opaque I/S Single Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0170 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.07-R3.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0170.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514010B.pdf FL22378_R7_AE_514014B.pdf Created by Independent Third Party: Yes 22378.2 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Opaque O/S Single Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0170 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.07-R3.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0170.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514010B.pdf FL22378_R7_AE_514014B.pdf Created by Independent Third Party: Yes 22378.3 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Opaque I/S Single or Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.5/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0170 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.07-R3.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0170.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514008B.pdf FL22378_R7_AE_514012B.pdf Created by Independent Third Party: Yes 22378.4 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Opaque O/S Single or Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0170 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.07-R3.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0170.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514008B.pdf FL22378_R7_AE_514012B.pdf Created by Independent Third Party: Yes 22378.5 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Impact Glazed I/S or O/S Single Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 9'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0172 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.09-R4.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0172.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514008B.pdf FL22378_R7_AE_514012B.pdf Created by Independent Third Party: Yes 22378.6 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Impact Glazed I/S Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-55 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0172 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.09-R4.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0172.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514008B.pdf FL22378_R7_AE_514012B.pdf Created by Independent Third Party: Yes 22378.7 Stormguard Fiberglass Side-Hinged Door Unit 6'-8" Impact Glazed O/S Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-55 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0172 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.09-R4.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0172.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514008B.pdf FL22378_R7_AE_514012B.pdf Created by Independent Third Party: Yes 22378.8 Stormguard Fiberglass Side-Hinged Door Unit 8'-0" Opaque I/S Single Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-65 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0171 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.08-R2.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0171.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514009B.pdf FL22378_R7_AE_514013B.pdf Created by Independent Third Party: Yes 22378.9 Stormguard Fiberglass Side-Hinged Door Unit 8'-0" Opaque O/S Single Door Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0171 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.08-R2.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0171.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514009B.pdf FL22378_R7_AE_514013B.pdf Created by Independent Third Party: Yes 22378.10 Stormguard Fiberglass Side-Hinged Door Unit 8'-0" Opaque I/S Single or Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50.0/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0171 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.08-R2.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0171.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514007B.pdf FL22378_R7_AE_514011B.pdf Created by Independent Third Party: Yes 22378.11 Stormguard Fiberglass Side-Hinged 8'-0" Opaque O/S Single or Double Door w/ or w/o Sidelites Door Unit Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-50.5 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0171 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.08-R2.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0171.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514007B.pdf FL22378_R7_AE_514011B.pdf Created by Independent Third Party: Yes 22378.12 Stormguard Fiberglass Side-Hinged Door Unit 8'-0" Impact Glazed I/S Single or Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +43/-47 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0173 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.04-R7.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0173.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514007B.pdf FL22378_R7_AE_514011B.pdf Created by Independent Third Party: Yes 22378.13 Stormguard Fiberglass Side-Hinged Door Unit 8'-0" Impact Glazed O/S Single or Double Door w/ or w/o Sidelites Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +47/-45 Other: Evaluated for use in locations adhering to the Florida Building Code, including the High Velocity Hurricane Zone, and where pressure requirements do not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. Hurricane protective system is NOT required. See DWG-MA-FL0173 for anchor details and water performance where required. Certification Agency Certificate FL22378_R7_C_CAC_NI007077.04-R7.pdf Quality Assurance Contract Expiration Date 12/31/2025 Installation Instructions FL22378_R7_II_FL0173.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL22378_R7_AE_514007B.pdf FL22378_R7_AE_514011B.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certification No.: NI007077.09-R4 1955 Powis Road Certification Date: 05/22/20017 West Chicago, IL 60185 Expiration Date: 12/31/2025 Revision Date: 07/27/2020 Product: Fiberglass Impact Rated Glazed Inswing or Outswing Door w/ and w/o Impact Rated Sidelites (w/Wood Frame or Worldwide Composite Frame³ unless noted) Specification: TAS 201/202/203-94/ASTM E330-02 The “Notice of Product Certification” is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI’s Certified Product Listing at www.Namicertification.com. NAMI’s Certification Program is accredited by The American National Standards Institute (ANSI). Configuration Inswing or Outswing Glazed or Opaque Maximum Size Structural Design Pressure Water Test Pressure Missile Impact Rated Test Report Number Drawing Number & Comments X Single I/S Glazed 3’0” x 6’8” +55/-55 0 psf Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1885 X Single O/S Glazed 3’0” x 6’8” +55/-55 3.75 psf/ 6.0 psf 1 8.25 psf 2/9.0 psf 4 7.5 psf 5 Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1835/W- 1860/W-1885 XX Double I/S Glazed 6’0” x 6’8” +50/-55 0 psf Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1885 XX Double O/S Glazed 6’0” x 6’8” +55/-55 3.75 psf/ 6.0 psf 1 8.25 psf 2/8.25 psf 4 Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 XO/OX Single w/Sidelite I/S Glazed Door Glazed Sidelite 6’0” x 6’8” +55/-55 0 psf Door-Yes Sidelite-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1885 XO/OX Single w/Sidelite O/S Glazed Door Glazed Sidelite 6’0” x 6’8” +55/-55 3.75 psf/ 6.0 psf 1 8.25 psf 2/9.0 psf 4 Door-Yes Sidelite-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 OXO Single w/Sidelites I/S Glazed Door Glazed Sidelites 9’0” x 6’8” +55/-55 0 psf Door-Yes Sidelite-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1885 OXO Single w/Sidelites O/S Glazed Door Glazed Sidelites 9’0” x 6’8” +55/-55 3.75 psf/ 6.0 psf 1 8.25 psf 2/9.0 psf 4 Door-Yes Sidelite-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 OXXO Double w/Sidelites I/S Glazed Doors Glazed Sidelites 12’6” x 6’8” +50/-55 0 psf Door-Yes Sidelite-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1885 OXXO Double w/Sidelites O/S Glazed Doors Glazed Sidelites 12’6” x 6’8” +55/-55 3.75 psf/ 6.0 psf 1 8.25 psf 2/8.25 psf 4 Door-Yes Sidelite-Yes NCTL-210-3389-1/ATLNC 1203.01-14/ATLNC 1012.01-16 Maximum Panel Size: 3’0” x 6’8” Anchor Details-MA-FL0172-07/W-1807/W-1835/W-1885 1 -Denotes Z-Series Threshold Design 2 -Denotes High Dam Threshold Design 3-W-1815 4-Denotes Worldwide Pro T4 Threshold 5-Denotes HP Outswing Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: ______________________________