Loading...
HomeMy WebLinkAboutAPPROVED, Wind load calculations    MecaWind v2318     Software Developer: Meca Enterprises Inc., www.meca.biz, Copyright © 2018     Calculations Prepared by:     Date: Feb 10, 2021                            Project #:    Port     Designer: Percy Malpartida                    Location:    Port st luci     FileLocation :      Basic Wind Parameters     Wind Load Standard            = ASCE 7­10    Exposure Category             = D      Wind Design Speed             = 175.0 mph    Risk Category                 = III      Structure Type                = Building     Building Type                 = Enclosed      General Wind Settings               = ASCE 7­10 Wind Parameters                                       =      Incl_LF   = Include ASD Load Factor of 0.6 in Pressures                     = True     DynType   = Dynamic Type of Structure                                       = Rigid     NF        = Natural Frequency of Structure (Mode 1)                         = 1.000 Hz     NF        = Natural Frequency of Structure                                  = 1.000 Hz     Zg        = Altitude (Ground Elevation) above Sea Level                     = 0.000 ft     Bdist     = Base Elevation of Structure                                     = 0.000 ft     GenElev   = Specify the Elevations For Wind Pressures                       = Mean Roof Ht     SDB       = Simple Diaphragm Building                                       = False     MWFRS     = Analysis Procedure being used for MWFRS                         = Ch 27 Pt 1     C&C       = Analysis Procedure being used for C&C                           = Ch 30 Pt 1     MWFRSType = MWFRS Method Selected                                           = Ch 27 Pt 1     Topographic Factor per Fig 26.8­1     Topo      = Topographic Feature                                             = None     Kzt       = Topographic Factor                                              = 1.000      Building Inputs     RoofType: Building Roof Type  = MultiGabled          : MultiGabled         =       W       : Width Perp to Ridge = 11.000 ft    L       : Length Along Ridge  = 21.000 ft     EHt     : Eave Height         = 12.000 ft    RE      : Roof Entry Method   = Slope      Slope   : Slope of Roof       = 3.0 :12      Parapet : Type of Parapet     = None      Theta   : Roof Slope          = 14.04 Deg    Par     : Is there a Parapet  = False      OH_ALL  : None                = 0.000 ft     OH_ALL  : None                = 0.000 ft     OH_ALL  : None                = 0.000 ft                                          Exposure Constants per Table 26.9­1:     Alpha: Const from Table 26.9­1= 11.500       Zg:    Const from Table 26.9­1= 700.000 ft     At:    Const from Table 26.9­1= 0.087        Bt:    Const from Table 26.9­1= 1.070      Am:    Const from Table 26.9­1= 0.111        Bm:    Const from Table 26.9­1= 0.800      C:     Const from Table 26.9­1= 0.150        Eps:   Const from Table 26.9­1= 0.125      Overhang Inputs:     Std       = Overhangs on all sides are the same                             = True     OHType    = Type of Roof Wall Intersections                                 = None     Main Wind Force Resisting System (MWFRS) Calculations per Ch 27 Part 1:     EHt       = Eave Height                                                     = 12.000 ft     RHt       = Ridge Height                                                    = 13.375 ft     h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft     Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft     Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * (15/zg)^(2/Alpha)           = 1.030      Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000      Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85      GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18     RA        = Roof Area                                                       = 238.11 sq ft     LF        = Load Factor based upon ASD Design                               = 0.60      qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf     qin       = For Negative Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf     qip       = For Positive Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf     Gust Factor Calculation:     Gust Factor Category I Rigid Structures ­ Simplified Method     G1        = For Rigid Structures (Nat. Freq.>1 Hz) use 0.85                 = 0.85      Gust Factor Category II Rigid Structures ­ Complete Analysis     Zm        = 0.6 * Ht                                                        = 7.613 ft     Izm       = Cc * (33 / Zm) ^ 0.167                                          = 0.192      Lzm       = L * (Zm / 33) ^ Epsilon                                         = 541.116      Q         = (1 / (1 + 0.63 * ((B + Ht) / Lzm)^0.63))^0.5                    = 0.959      G2        = 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm))                       = 0.905      Gust Factor Used in Analysis     G         = Lessor Of G1 Or G2                                              = 0.850      MWFRS Wind Normal to Ridge (Ref Fig 27.4­1}     h         = Mean Roof Height Of Building                                    = 12.688 ft     RHt       = Ridge Height Of Roof                                            = 13.375 ft     B         = Horizontal Dimension Of Building Normal To Wind Direction       = 21.000 ft     L         = Horizontal Dimension Of building Parallel To Wind Direction     = 11.000 ft     L/B       = Ratio Of L/B used For Cp determination                          = 0.524      h/L       = Ratio Of h/L used For Cp determination                          = 1.153      Slope     = Slope of Roof                                                   = 14.04 Deg     Roof_LW   = Roof Coefficient (Leeward)                                      = ­0.62, ­0.62     Roof_WW   = Roof Coefficient (Windward)                                     = ­0.18, ­1.06     Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80      Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.50      Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70      GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50      GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00      Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Normal to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                  psf   psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          12.00 1.030  1.000  41.19  0.18     20.60  ­24.92   ­31.92  45.52       9.60     Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Normal to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                 psf    psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          12.00 1.030 1.000  41.19  ­0.18     35.43  ­10.09   ­17.09  45.52       9.60          Notes Wall Pressures:          Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor          qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient          Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi          Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press          * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Normal to Ridge     All wind pressures include a load factor of 0.6          Roof Var Start End  Cp_min Cp_max GCPi  Pressure Pressure Pressure  Pressure                   Dist  Dist                     Pn_min*  Pp_min*   Pn_max    Pp_max                     ft    ft                        psf      psf      psf       psf             ­­­­­­­­ ­­­­­ ­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­  ­­­­­­­­          Roof_LW    N/A  N/A ­0.620 ­0.620 0.180   ­14.29   ­29.12   ­14.29    ­29.12          Roof_WW    N/A  N/A ­0.180 ­1.060 0.180     1.11   ­13.72   ­29.70    ­44.53          Notes Roof Pressures:          Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge          Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude          Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)          Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)          OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical            * The smaller uplift pressures due to Cp_Min can become critical when wind is combined            with roof live load or snow load;  load combinations are given in ASCE 7          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     MWFRS Wind Parallel to Ridge (Ref Fig 27.4­1}     h         = Mean Roof Height Of Building                                    = 12.688 ft     RHt       = Ridge Height Of Roof                                            = 13.375 ft     B         = Horizontal Dimension Of Building Normal To Wind Direction       = 11.000 ft     L         = Horizontal Dimension Of building Parallel To Wind Direction     = 21.000 ft     L/B       = Ratio Of L/B used For Cp determination                          = 1.909      h/L       = Ratio Of h/L used For Cp determination                          = 0.604      Slope     = Slope of Roof                                                   = 14.04 Deg     Roof      = **Roof  Coeff (0 to h/2) (0.000 ft to 6.344 ft)                 = ­0.18, ­0.958     Roof_1    = Roof  Coeff (h/2 to h) (6.344 ft to 12.688 ft)                  = ­0.18, ­0.858     Roof_2    = Roof  Coeff (h to 2h) (12.688 ft to 25.375 ft)                  = ­0.18, ­0.542     **Includes Reduction Factor 0.91 For roof area, applied To Cp=­1.3 For h/L>=1 & (0 To h/2)     Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80      Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.32      Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70      GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50      GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00      Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                  psf   psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          13.38 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60          12.69 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60          12.00 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60     Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                 psf    psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          13.38 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          12.69 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          12.00 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          Notes Wall Pressures:          Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor          qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient          Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi          Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press          * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6           Roof Var   Start   End   Cp_min Cp_max GCPi  Pressure Pressure Pressure Pressure                       Dist   Dist                      Pn_min*  Pp_min*   Pn_max   Pp_max                         ft     ft                         psf      psf      psf      psf             ­­­­­­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­          Roof (+Y)    0.000  6.344 ­0.180 ­0.958 0.180     1.11   ­13.72   ­26.14   ­40.97          Roof_1 (+Y)  6.344 12.688 ­0.180 ­0.858 0.180     1.11   ­13.72   ­22.64   ­37.47          Roof_2 (+Y) 12.688 25.375 ­0.180 ­0.542 0.180     1.11   ­13.72   ­11.55   ­26.38          Notes Roof Pressures:          Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge          Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude          Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)          Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)          OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical            * The smaller uplift pressures due to Cp_Min can become critical when wind is combined            with roof live load or snow load;  load combinations are given in ASCE 7          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Components And Cladding (C&C) Calculations per Ch 30 Part 1:     EHt       = Eave Height                                                     = 12.000 ft     RHt       = Ridge Height                                                    = 13.375 ft     h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft     Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft     Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * ( [15 ft or 4.572 m] / zg)^(2/Alpha)= 1.030      Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000      Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85      GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18     LF        = Load Factor based upon ASD Design                               = 0.60      qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf     LHD       = Least Horizontal Dimension:  Min(B, L)                          = 11.000 ft     a1        = Min(0.1 * LHD,  0.4 * h                                         = 1.100 ft     a         = Max(a1, 0.04 * LHD, 3 ft [0.9 m])                               = 3.000 ft     Wind Pressures for C&C Ch 30 Pt 1     All wind pressures include a load factor of 0.6     Description Zone  Width  Span   Area   1/3    Ref     GCp    GCp      p      p                                               Rule   Fig     Max    Min     Max    Min           ft             ft     ft    sq ft                                psf    psf       ­­­­­­­­­­­ ­­­­  ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­  ­­­­­  ­­­­­­  ­­­­­  ­­­­­­     D­1          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47     D­2          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47        Area     = Span Length x Effective Width        1/3 Rule = Effective width need not be less than 1/3 of the span length        GCp      = External Pressure Coefficients taken from Figures 30.4­1 through 30.4­7        p        = Wind Pressure:  qh*(GCp ­ GCpi)  [Eqn 30.4­1]*        *Per Para 30.2.2 the Minimum Pressure for C&C is 9.60 psf [0.460 kPa] {Includes LF}     MecaWind v2318    Software Developer: Meca Enterprises Inc., www.meca.biz, Copyright © 2018    Calculations Prepared by:    Date: Feb 10, 2021                            Project #:    Port    Designer: Percy Malpartida                    Location:    Port st luci    FileLocation :     Basic Wind Parameters    Wind Load Standard            = ASCE 7­10    Exposure Category             = D     Wind Design Speed             = 175.0 mph    Risk Category                 = III     Structure Type                = Building     Building Type                 = Enclosed     General Wind Settings              = ASCE 7­10 Wind Parameters                                       =     Incl_LF   = Include ASD Load Factor of 0.6 in Pressures                     = True    DynType   = Dynamic Type of Structure                                       = Rigid    NF        = Natural Frequency of Structure (Mode 1)                         = 1.000 Hz    NF        = Natural Frequency of Structure                                  = 1.000 Hz    Zg        = Altitude (Ground Elevation) above Sea Level                     = 0.000 ft    Bdist     = Base Elevation of Structure                                     = 0.000 ft    GenElev   = Specify the Elevations For Wind Pressures                       = Mean Roof Ht    SDB       = Simple Diaphragm Building                                       = False    MWFRS     = Analysis Procedure being used for MWFRS                         = Ch 27 Pt 1    C&C       = Analysis Procedure being used for C&C                           = Ch 30 Pt 1    MWFRSType = MWFRS Method Selected                                           = Ch 27 Pt 1    Topographic Factor per Fig 26.8­1    Topo      = Topographic Feature                                             = None    Kzt       = Topographic Factor                                              = 1.000     Building Inputs    RoofType: Building Roof Type  = MultiGabled          : MultiGabled         =      W       : Width Perp to Ridge = 11.000 ft    L       : Length Along Ridge  = 21.000 ft    EHt     : Eave Height         = 12.000 ft    RE      : Roof Entry Method   = Slope     Slope   : Slope of Roof       = 3.0 :12      Parapet : Type of Parapet     = None     Theta   : Roof Slope          = 14.04 Deg    Par     : Is there a Parapet  = False     OH_ALL  : None                = 0.000 ft     OH_ALL  : None                = 0.000 ft    OH_ALL  : None                = 0.000 ft                                         Exposure Constants per Table 26.9­1:    Alpha: Const from Table 26.9­1= 11.500       Zg:    Const from Table 26.9­1= 700.000 ft    At:    Const from Table 26.9­1= 0.087        Bt:    Const from Table 26.9­1= 1.070     Am:    Const from Table 26.9­1= 0.111        Bm:    Const from Table 26.9­1= 0.800     C:     Const from Table 26.9­1= 0.150        Eps:   Const from Table 26.9­1= 0.125     Overhang Inputs:    Std       = Overhangs on all sides are the same                             = True    OHType    = Type of Roof Wall Intersections                                 = None    Main Wind Force Resisting System (MWFRS) Calculations per Ch 27 Part 1:    EHt       = Eave Height                                                     = 12.000 ft    RHt       = Ridge Height                                                    = 13.375 ft    h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft    Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft    Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * (15/zg)^(2/Alpha)           = 1.030     Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000     Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85     GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18    RA        = Roof Area                                                       = 238.11 sq ft    LF        = Load Factor based upon ASD Design                               = 0.60     qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf    qin       = For Negative Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf    qip       = For Positive Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf    Gust Factor Calculation:    Gust Factor Category I Rigid Structures ­ Simplified Method    G1        = For Rigid Structures (Nat. Freq.>1 Hz) use 0.85                 = 0.85     Gust Factor Category II Rigid Structures ­ Complete Analysis    Zm        = 0.6 * Ht                                                        = 7.613 ft    Izm       = Cc * (33 / Zm) ^ 0.167                                          = 0.192     Lzm       = L * (Zm / 33) ^ Epsilon                                         = 541.116     Q         = (1 / (1 + 0.63 * ((B + Ht) / Lzm)^0.63))^0.5                    = 0.959     G2        = 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm))                       = 0.905     Gust Factor Used in Analysis     G         = Lessor Of G1 Or G2                                              = 0.850      MWFRS Wind Normal to Ridge (Ref Fig 27.4­1}     h         = Mean Roof Height Of Building                                    = 12.688 ft     RHt       = Ridge Height Of Roof                                            = 13.375 ft     B         = Horizontal Dimension Of Building Normal To Wind Direction       = 21.000 ft     L         = Horizontal Dimension Of building Parallel To Wind Direction     = 11.000 ft     L/B       = Ratio Of L/B used For Cp determination                          = 0.524      h/L       = Ratio Of h/L used For Cp determination                          = 1.153      Slope     = Slope of Roof                                                   = 14.04 Deg     Roof_LW   = Roof Coefficient (Leeward)                                      = ­0.62, ­0.62     Roof_WW   = Roof Coefficient (Windward)                                     = ­0.18, ­1.06     Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80      Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.50      Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70      GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50      GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00      Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Normal to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                  psf   psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          12.00 1.030  1.000  41.19  0.18     20.60  ­24.92   ­31.92  45.52       9.60     Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Normal to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                 psf    psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          12.00 1.030 1.000  41.19  ­0.18     35.43  ­10.09   ­17.09  45.52       9.60          Notes Wall Pressures:          Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor          qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient          Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi          Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press          * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Normal to Ridge     All wind pressures include a load factor of 0.6          Roof Var Start End  Cp_min Cp_max GCPi  Pressure Pressure Pressure  Pressure                   Dist  Dist                     Pn_min*  Pp_min*   Pn_max    Pp_max                     ft    ft                        psf      psf      psf       psf             ­­­­­­­­ ­­­­­ ­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­  ­­­­­­­­          Roof_LW    N/A  N/A ­0.620 ­0.620 0.180   ­14.29   ­29.12   ­14.29    ­29.12          Roof_WW    N/A  N/A ­0.180 ­1.060 0.180     1.11   ­13.72   ­29.70    ­44.53          Notes Roof Pressures:          Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge          Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude          Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)          Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)          OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical            * The smaller uplift pressures due to Cp_Min can become critical when wind is combined            with roof live load or snow load;  load combinations are given in ASCE 7          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     MWFRS Wind Parallel to Ridge (Ref Fig 27.4­1}     h         = Mean Roof Height Of Building                                    = 12.688 ft     RHt       = Ridge Height Of Roof                                            = 13.375 ft     B         = Horizontal Dimension Of Building Normal To Wind Direction       = 11.000 ft     L         = Horizontal Dimension Of building Parallel To Wind Direction     = 21.000 ft     L/B       = Ratio Of L/B used For Cp determination                          = 1.909      h/L       = Ratio Of h/L used For Cp determination                          = 0.604      Slope     = Slope of Roof                                                   = 14.04 Deg     Roof      = **Roof  Coeff (0 to h/2) (0.000 ft to 6.344 ft)                 = ­0.18, ­0.958     Roof_1    = Roof  Coeff (h/2 to h) (6.344 ft to 12.688 ft)                  = ­0.18, ­0.858     Roof_2    = Roof  Coeff (h to 2h) (12.688 ft to 25.375 ft)                  = ­0.18, ­0.542     **Includes Reduction Factor 0.91 For roof area, applied To Cp=­1.3 For h/L>=1 & (0 To h/2)     Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80      Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.32      Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70      GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50      GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00      Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                  psf   psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          13.38 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60          12.69 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60          12.00 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60     Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                 psf    psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          13.38 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          12.69 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          12.00 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          Notes Wall Pressures:          Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor          qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient          Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi          Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press          * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6           Roof Var   Start   End   Cp_min Cp_max GCPi  Pressure Pressure Pressure Pressure                       Dist   Dist                      Pn_min*  Pp_min*   Pn_max   Pp_max                         ft     ft                         psf      psf      psf      psf             ­­­­­­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­          Roof (+Y)    0.000  6.344 ­0.180 ­0.958 0.180     1.11   ­13.72   ­26.14   ­40.97          Roof_1 (+Y)  6.344 12.688 ­0.180 ­0.858 0.180     1.11   ­13.72   ­22.64   ­37.47          Roof_2 (+Y) 12.688 25.375 ­0.180 ­0.542 0.180     1.11   ­13.72   ­11.55   ­26.38          Notes Roof Pressures:          Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge          Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude          Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)          Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)          OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical            * The smaller uplift pressures due to Cp_Min can become critical when wind is combined            with roof live load or snow load;  load combinations are given in ASCE 7          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Components And Cladding (C&C) Calculations per Ch 30 Part 1:     EHt       = Eave Height                                                     = 12.000 ft     RHt       = Ridge Height                                                    = 13.375 ft     h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft     Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft     Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * ( [15 ft or 4.572 m] / zg)^(2/Alpha)= 1.030      Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000      Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85      GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18     LF        = Load Factor based upon ASD Design                               = 0.60      qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf     LHD       = Least Horizontal Dimension:  Min(B, L)                          = 11.000 ft     a1        = Min(0.1 * LHD,  0.4 * h                                         = 1.100 ft     a         = Max(a1, 0.04 * LHD, 3 ft [0.9 m])                               = 3.000 ft     Wind Pressures for C&C Ch 30 Pt 1     All wind pressures include a load factor of 0.6     Description Zone  Width  Span   Area   1/3    Ref     GCp    GCp      p      p                                               Rule   Fig     Max    Min     Max    Min           ft             ft     ft    sq ft                                psf    psf       ­­­­­­­­­­­ ­­­­  ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­  ­­­­­  ­­­­­­  ­­­­­  ­­­­­­     D­1          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47     D­2          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47        Area     = Span Length x Effective Width        1/3 Rule = Effective width need not be less than 1/3 of the span length        GCp      = External Pressure Coefficients taken from Figures 30.4­1 through 30.4­7        p        = Wind Pressure:  qh*(GCp ­ GCpi)  [Eqn 30.4­1]*        *Per Para 30.2.2 the Minimum Pressure for C&C is 9.60 psf [0.460 kPa] {Includes LF}     MecaWind v2318    Software Developer: Meca Enterprises Inc., www.meca.biz, Copyright © 2018    Calculations Prepared by:    Date: Feb 10, 2021                            Project #:    Port    Designer: Percy Malpartida                    Location:    Port st luci    FileLocation :     Basic Wind Parameters    Wind Load Standard            = ASCE 7­10    Exposure Category             = D     Wind Design Speed             = 175.0 mph    Risk Category                 = III     Structure Type                = Building     Building Type                 = Enclosed     General Wind Settings              = ASCE 7­10 Wind Parameters                                       =     Incl_LF   = Include ASD Load Factor of 0.6 in Pressures                     = True    DynType   = Dynamic Type of Structure                                       = Rigid    NF        = Natural Frequency of Structure (Mode 1)                         = 1.000 Hz    NF        = Natural Frequency of Structure                                  = 1.000 Hz    Zg        = Altitude (Ground Elevation) above Sea Level                     = 0.000 ft    Bdist     = Base Elevation of Structure                                     = 0.000 ft    GenElev   = Specify the Elevations For Wind Pressures                       = Mean Roof Ht    SDB       = Simple Diaphragm Building                                       = False    MWFRS     = Analysis Procedure being used for MWFRS                         = Ch 27 Pt 1    C&C       = Analysis Procedure being used for C&C                           = Ch 30 Pt 1    MWFRSType = MWFRS Method Selected                                           = Ch 27 Pt 1    Topographic Factor per Fig 26.8­1    Topo      = Topographic Feature                                             = None    Kzt       = Topographic Factor                                              = 1.000     Building Inputs    RoofType: Building Roof Type  = MultiGabled          : MultiGabled         =      W       : Width Perp to Ridge = 11.000 ft    L       : Length Along Ridge  = 21.000 ft    EHt     : Eave Height         = 12.000 ft    RE      : Roof Entry Method   = Slope     Slope   : Slope of Roof       = 3.0 :12      Parapet : Type of Parapet     = None     Theta   : Roof Slope          = 14.04 Deg    Par     : Is there a Parapet  = False     OH_ALL  : None                = 0.000 ft     OH_ALL  : None                = 0.000 ft    OH_ALL  : None                = 0.000 ft                                         Exposure Constants per Table 26.9­1:    Alpha: Const from Table 26.9­1= 11.500       Zg:    Const from Table 26.9­1= 700.000 ft    At:    Const from Table 26.9­1= 0.087        Bt:    Const from Table 26.9­1= 1.070     Am:    Const from Table 26.9­1= 0.111        Bm:    Const from Table 26.9­1= 0.800     C:     Const from Table 26.9­1= 0.150        Eps:   Const from Table 26.9­1= 0.125     Overhang Inputs:    Std       = Overhangs on all sides are the same                             = True    OHType    = Type of Roof Wall Intersections                                 = None    Main Wind Force Resisting System (MWFRS) Calculations per Ch 27 Part 1:    EHt       = Eave Height                                                     = 12.000 ft    RHt       = Ridge Height                                                    = 13.375 ft    h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft    Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft    Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * (15/zg)^(2/Alpha)           = 1.030     Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000     Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85     GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18    RA        = Roof Area                                                       = 238.11 sq ft    LF        = Load Factor based upon ASD Design                               = 0.60     qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf    qin       = For Negative Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf    qip       = For Positive Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf    Gust Factor Calculation:    Gust Factor Category I Rigid Structures ­ Simplified Method    G1        = For Rigid Structures (Nat. Freq.>1 Hz) use 0.85                 = 0.85     Gust Factor Category II Rigid Structures ­ Complete Analysis    Zm        = 0.6 * Ht                                                        = 7.613 ft    Izm       = Cc * (33 / Zm) ^ 0.167                                          = 0.192     Lzm       = L * (Zm / 33) ^ Epsilon                                         = 541.116     Q         = (1 / (1 + 0.63 * ((B + Ht) / Lzm)^0.63))^0.5                    = 0.959     G2        = 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm))                       = 0.905     Gust Factor Used in Analysis    G         = Lessor Of G1 Or G2                                              = 0.850     MWFRS Wind Normal to Ridge (Ref Fig 27.4­1}    h         = Mean Roof Height Of Building                                    = 12.688 ft    RHt       = Ridge Height Of Roof                                            = 13.375 ft    B         = Horizontal Dimension Of Building Normal To Wind Direction       = 21.000 ft    L         = Horizontal Dimension Of building Parallel To Wind Direction     = 11.000 ft    L/B       = Ratio Of L/B used For Cp determination                          = 0.524     h/L       = Ratio Of h/L used For Cp determination                          = 1.153     Slope     = Slope of Roof                                                   = 14.04 Deg    Roof_LW   = Roof Coefficient (Leeward)                                      = ­0.62, ­0.62    Roof_WW   = Roof Coefficient (Windward)                                     = ­0.18, ­1.06    Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80     Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.50     Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70     GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50     GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00     Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Normal to Ridge    All wind pressures include a load factor of 0.6         Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                            Press     Press   Press   Press  Pressure*          ft                  psf   psf     psf       psf     psf     psf      psf            ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­         12.00 1.030  1.000  41.19  0.18     20.60  ­24.92   ­31.92  45.52       9.60    Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Normal to Ridge    All wind pressures include a load factor of 0.6         Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                            Press     Press   Press   Press  Pressure*          ft                 psf    psf     psf       psf     psf     psf      psf            ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­         12.00 1.030 1.000  41.19  ­0.18     35.43  ­10.09   ­17.09  45.52       9.60         Notes Wall Pressures:         Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor         qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient         Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi         Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press         * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls         + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface    Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Normal to Ridge    All wind pressures include a load factor of 0.6         Roof Var Start End  Cp_min Cp_max GCPi  Pressure Pressure Pressure  Pressure                  Dist  Dist                     Pn_min*  Pp_min*   Pn_max    Pp_max                    ft    ft                        psf      psf      psf       psf            ­­­­­­­­ ­­­­­ ­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­  ­­­­­­­­         Roof_LW    N/A  N/A ­0.620 ­0.620 0.180   ­14.29   ­29.12   ­14.29    ­29.12         Roof_WW    N/A  N/A ­0.180 ­1.060 0.180     1.11   ­13.72   ­29.70    ­44.53         Notes Roof Pressures:         Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge         Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude         Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)         Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)         OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical           * The smaller uplift pressures due to Cp_Min can become critical when wind is combined           with roof live load or snow load;  load combinations are given in ASCE 7         + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface    MWFRS Wind Parallel to Ridge (Ref Fig 27.4­1}    h         = Mean Roof Height Of Building                                    = 12.688 ft    RHt       = Ridge Height Of Roof                                            = 13.375 ft    B         = Horizontal Dimension Of Building Normal To Wind Direction       = 11.000 ft    L         = Horizontal Dimension Of building Parallel To Wind Direction     = 21.000 ft    L/B       = Ratio Of L/B used For Cp determination                          = 1.909     h/L       = Ratio Of h/L used For Cp determination                          = 0.604     Slope     = Slope of Roof                                                   = 14.04 Deg    Roof      = **Roof  Coeff (0 to h/2) (0.000 ft to 6.344 ft)                 = ­0.18, ­0.958    Roof_1    = Roof  Coeff (h/2 to h) (6.344 ft to 12.688 ft)                  = ­0.18, ­0.858    Roof_2    = Roof  Coeff (h to 2h) (12.688 ft to 25.375 ft)                  = ­0.18, ­0.542    **Includes Reduction Factor 0.91 For roof area, applied To Cp=­1.3 For h/L>=1 & (0 To h/2)     Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80      Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.32      Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70      GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50      GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00      Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                  psf   psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          13.38 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60          12.69 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60          12.00 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60     Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6          Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                             Press     Press   Press   Press  Pressure*           ft                 psf    psf     psf       psf     psf     psf      psf             ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­          13.38 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          12.69 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          12.00 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60          Notes Wall Pressures:          Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor          qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient          Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi          Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press          * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Parallel to Ridge     All wind pressures include a load factor of 0.6           Roof Var   Start   End   Cp_min Cp_max GCPi  Pressure Pressure Pressure Pressure                       Dist   Dist                      Pn_min*  Pp_min*   Pn_max   Pp_max                         ft     ft                         psf      psf      psf      psf             ­­­­­­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­          Roof (+Y)    0.000  6.344 ­0.180 ­0.958 0.180     1.11   ­13.72   ­26.14   ­40.97          Roof_1 (+Y)  6.344 12.688 ­0.180 ­0.858 0.180     1.11   ­13.72   ­22.64   ­37.47          Roof_2 (+Y) 12.688 25.375 ­0.180 ­0.542 0.180     1.11   ­13.72   ­11.55   ­26.38          Notes Roof Pressures:          Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge          Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude          Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)          Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)          OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical            * The smaller uplift pressures due to Cp_Min can become critical when wind is combined            with roof live load or snow load;  load combinations are given in ASCE 7          + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface     Components And Cladding (C&C) Calculations per Ch 30 Part 1:     EHt       = Eave Height                                                     = 12.000 ft     RHt       = Ridge Height                                                    = 13.375 ft     h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft     Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft     Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * ( [15 ft or 4.572 m] / zg)^(2/Alpha)= 1.030      Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000      Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85      GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18     LF        = Load Factor based upon ASD Design                               = 0.60      qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf     LHD       = Least Horizontal Dimension:  Min(B, L)                          = 11.000 ft     a1        = Min(0.1 * LHD,  0.4 * h                                         = 1.100 ft     a         = Max(a1, 0.04 * LHD, 3 ft [0.9 m])                               = 3.000 ft     Wind Pressures for C&C Ch 30 Pt 1     All wind pressures include a load factor of 0.6     Description Zone  Width  Span   Area   1/3    Ref     GCp    GCp      p      p                                               Rule   Fig     Max    Min     Max    Min           ft             ft     ft    sq ft                                psf    psf       ­­­­­­­­­­­ ­­­­  ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­  ­­­­­  ­­­­­­  ­­­­­  ­­­­­­     D­1          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47     D­2          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47        Area     = Span Length x Effective Width        1/3 Rule = Effective width need not be less than 1/3 of the span length        GCp      = External Pressure Coefficients taken from Figures 30.4­1 through 30.4­7        p        = Wind Pressure:  qh*(GCp ­ GCpi)  [Eqn 30.4­1]*        *Per Para 30.2.2 the Minimum Pressure for C&C is 9.60 psf [0.460 kPa] {Includes LF}     MecaWind v2318    Software Developer: Meca Enterprises Inc., www.meca.biz, Copyright © 2018    Calculations Prepared by:    Date: Feb 10, 2021                            Project #:    Port    Designer: Percy Malpartida                    Location:    Port st luci    FileLocation :     Basic Wind Parameters    Wind Load Standard            = ASCE 7­10    Exposure Category             = D     Wind Design Speed             = 175.0 mph    Risk Category                 = III     Structure Type                = Building     Building Type                 = Enclosed     General Wind Settings              = ASCE 7­10 Wind Parameters                                       =     Incl_LF   = Include ASD Load Factor of 0.6 in Pressures                     = True    DynType   = Dynamic Type of Structure                                       = Rigid    NF        = Natural Frequency of Structure (Mode 1)                         = 1.000 Hz    NF        = Natural Frequency of Structure                                  = 1.000 Hz    Zg        = Altitude (Ground Elevation) above Sea Level                     = 0.000 ft    Bdist     = Base Elevation of Structure                                     = 0.000 ft    GenElev   = Specify the Elevations For Wind Pressures                       = Mean Roof Ht    SDB       = Simple Diaphragm Building                                       = False    MWFRS     = Analysis Procedure being used for MWFRS                         = Ch 27 Pt 1    C&C       = Analysis Procedure being used for C&C                           = Ch 30 Pt 1    MWFRSType = MWFRS Method Selected                                           = Ch 27 Pt 1    Topographic Factor per Fig 26.8­1    Topo      = Topographic Feature                                             = None    Kzt       = Topographic Factor                                              = 1.000     Building Inputs    RoofType: Building Roof Type  = MultiGabled          : MultiGabled         =      W       : Width Perp to Ridge = 11.000 ft    L       : Length Along Ridge  = 21.000 ft    EHt     : Eave Height         = 12.000 ft    RE      : Roof Entry Method   = Slope     Slope   : Slope of Roof       = 3.0 :12      Parapet : Type of Parapet     = None     Theta   : Roof Slope          = 14.04 Deg    Par     : Is there a Parapet  = False     OH_ALL  : None                = 0.000 ft     OH_ALL  : None                = 0.000 ft    OH_ALL  : None                = 0.000 ft                                         Exposure Constants per Table 26.9­1:    Alpha: Const from Table 26.9­1= 11.500       Zg:    Const from Table 26.9­1= 700.000 ft    At:    Const from Table 26.9­1= 0.087        Bt:    Const from Table 26.9­1= 1.070     Am:    Const from Table 26.9­1= 0.111        Bm:    Const from Table 26.9­1= 0.800     C:     Const from Table 26.9­1= 0.150        Eps:   Const from Table 26.9­1= 0.125     Overhang Inputs:    Std       = Overhangs on all sides are the same                             = True    OHType    = Type of Roof Wall Intersections                                 = None    Main Wind Force Resisting System (MWFRS) Calculations per Ch 27 Part 1:    EHt       = Eave Height                                                     = 12.000 ft    RHt       = Ridge Height                                                    = 13.375 ft    h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft    Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft    Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * (15/zg)^(2/Alpha)           = 1.030     Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000     Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85     GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18    RA        = Roof Area                                                       = 238.11 sq ft    LF        = Load Factor based upon ASD Design                               = 0.60     qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf    qin       = For Negative Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf    qip       = For Positive Internal Pressure of Enclosed Building use qh*LF   = 41.19 psf    Gust Factor Calculation:    Gust Factor Category I Rigid Structures ­ Simplified Method    G1        = For Rigid Structures (Nat. Freq.>1 Hz) use 0.85                 = 0.85     Gust Factor Category II Rigid Structures ­ Complete Analysis    Zm        = 0.6 * Ht                                                        = 7.613 ft    Izm       = Cc * (33 / Zm) ^ 0.167                                          = 0.192     Lzm       = L * (Zm / 33) ^ Epsilon                                         = 541.116     Q         = (1 / (1 + 0.63 * ((B + Ht) / Lzm)^0.63))^0.5                    = 0.959     G2        = 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm))                       = 0.905     Gust Factor Used in Analysis    G         = Lessor Of G1 Or G2                                              = 0.850     MWFRS Wind Normal to Ridge (Ref Fig 27.4­1}    h         = Mean Roof Height Of Building                                    = 12.688 ft    RHt       = Ridge Height Of Roof                                            = 13.375 ft    B         = Horizontal Dimension Of Building Normal To Wind Direction       = 21.000 ft    L         = Horizontal Dimension Of building Parallel To Wind Direction     = 11.000 ft    L/B       = Ratio Of L/B used For Cp determination                          = 0.524     h/L       = Ratio Of h/L used For Cp determination                          = 1.153     Slope     = Slope of Roof                                                   = 14.04 Deg    Roof_LW   = Roof Coefficient (Leeward)                                      = ­0.62, ­0.62    Roof_WW   = Roof Coefficient (Windward)                                     = ­0.18, ­1.06    Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80     Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.50     Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70     GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50     GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00     Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Normal to Ridge    All wind pressures include a load factor of 0.6         Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                            Press     Press   Press   Press  Pressure*          ft                  psf   psf     psf       psf     psf     psf      psf            ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­         12.00 1.030  1.000  41.19  0.18     20.60  ­24.92   ­31.92  45.52       9.60    Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Normal to Ridge    All wind pressures include a load factor of 0.6         Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                            Press     Press   Press   Press  Pressure*          ft                 psf    psf     psf       psf     psf     psf      psf            ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­         12.00 1.030 1.000  41.19  ­0.18     35.43  ­10.09   ­17.09  45.52       9.60         Notes Wall Pressures:         Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor         qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient         Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi         Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press         * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls         + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface    Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Normal to Ridge    All wind pressures include a load factor of 0.6         Roof Var Start End  Cp_min Cp_max GCPi  Pressure Pressure Pressure  Pressure                  Dist  Dist                     Pn_min*  Pp_min*   Pn_max    Pp_max                    ft    ft                        psf      psf      psf       psf            ­­­­­­­­ ­­­­­ ­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­  ­­­­­­­­         Roof_LW    N/A  N/A ­0.620 ­0.620 0.180   ­14.29   ­29.12   ­14.29    ­29.12         Roof_WW    N/A  N/A ­0.180 ­1.060 0.180     1.11   ­13.72   ­29.70    ­44.53         Notes Roof Pressures:         Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge         Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude         Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)         Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)         OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical           * The smaller uplift pressures due to Cp_Min can become critical when wind is combined           with roof live load or snow load;  load combinations are given in ASCE 7         + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface    MWFRS Wind Parallel to Ridge (Ref Fig 27.4­1}    h         = Mean Roof Height Of Building                                    = 12.688 ft    RHt       = Ridge Height Of Roof                                            = 13.375 ft    B         = Horizontal Dimension Of Building Normal To Wind Direction       = 11.000 ft    L         = Horizontal Dimension Of building Parallel To Wind Direction     = 21.000 ft    L/B       = Ratio Of L/B used For Cp determination                          = 1.909     h/L       = Ratio Of h/L used For Cp determination                          = 0.604     Slope     = Slope of Roof                                                   = 14.04 Deg    Roof      = **Roof  Coeff (0 to h/2) (0.000 ft to 6.344 ft)                 = ­0.18, ­0.958    Roof_1    = Roof  Coeff (h/2 to h) (6.344 ft to 12.688 ft)                  = ­0.18, ­0.858    Roof_2    = Roof  Coeff (h to 2h) (12.688 ft to 25.375 ft)                  = ­0.18, ­0.542    **Includes Reduction Factor 0.91 For roof area, applied To Cp=­1.3 For h/L>=1 & (0 To h/2)    Cp_WW     = Windward Wall Coefficient (All L/B Values)                      = 0.80     Cp_LW     = Leward Wall Coefficient Using L/B                               = ­0.32     Cp_SW     = Side Wall Coefficient (All L/B values)                          = ­0.70     GCpn_WW   = Parapet Combined Net Pressure Coefficient (Windward Parapet)    = 1.50     GCpn_LW   = Parapet Combined Net Pressure Coefficient (Leeward Parapet)     = ­1.00     Wall Wind Pressures based On Positive Internal Pressure (+GCPi) ­ Parallel to Ridge    All wind pressures include a load factor of 0.6         Elev   Kz     Kzt    qz    GCPi  Windward  Leeward   Side   Total   Minimum                                            Press     Press   Press   Press  Pressure*          ft                  psf   psf     psf       psf     psf     psf      psf            ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­         13.38 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60         12.69 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60         12.00 1.030  1.000  41.19  0.18     20.60  ­18.56   ­31.92  39.15       9.60    Wall Wind Pressures based on Negative Internal Pressure (­GCPi) ­ Parallel to Ridge    All wind pressures include a load factor of 0.6         Elev   Kz    Kzt    qz    GCPi   Windward  Leeward   Side   Total   Minimum                                            Press     Press   Press   Press  Pressure*          ft                 psf    psf     psf       psf     psf     psf      psf            ­­­­­ ­­­­­ ­­­­­  ­­­­­  ­­­­­  ­­­­­­­­  ­­­­­­­  ­­­­­­  ­­­­­  ­­­­­­­­­         13.38 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60         12.69 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60         12.00 1.030 1.000  41.19  ­0.18     35.43   ­3.73   ­17.09  39.15       9.60         Notes Wall Pressures:         Kz       = Velocity Press Exp Coeff        Kzt      = Topographical Factor         qz       = 0.00256*Kz*Kzt*Kd*V^2           GCPi     = Internal Press Coefficient         Side     = qh * G * Cp_SW ­ qip * +GCPi    Windward = qz * G * Cp_WW ­ qip * +GCPi         Leeward  = qh * G * Cp_LW ­ qip * +GCPi    Total    = Windward Press ­ Leeward Press         * Minimum Pressure: Para 27.4.7 no less than 9.60 psf (Incl LF) applied to Walls         + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface    Roof Wind Pressures for Positive & Negative Internal Pressure (+/­ GCPi) ­ Parallel to Ridge    All wind pressures include a load factor of 0.6          Roof Var   Start   End   Cp_min Cp_max GCPi  Pressure Pressure Pressure Pressure                      Dist   Dist                      Pn_min*  Pp_min*   Pn_max   Pp_max                        ft     ft                         psf      psf      psf      psf            ­­­­­­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­­ ­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­ ­­­­­­­­         Roof (+Y)    0.000  6.344 ­0.180 ­0.958 0.180     1.11   ­13.72   ­26.14   ­40.97         Roof_1 (+Y)  6.344 12.688 ­0.180 ­0.858 0.180     1.11   ­13.72   ­22.64   ­37.47         Roof_2 (+Y) 12.688 25.375 ­0.180 ­0.542 0.180     1.11   ­13.72   ­11.55   ­26.38         Notes Roof Pressures:         Start Dist = Start Dist from Windward Edge  End Dist = End Dist from Windward Edge         Cp_Max     = Largest Coefficient Magnitude  Cp_Min   = Smallest Coefficient Magnitude         Pp_max     = qh*G*Cp_max ­ qip*(+GCPi)      Pn_max   = qh*G*Cp_max ­ qin*(­GCpi)         Pp_min*    = qh*G*Cp_min ­ qip*(+GCPi)      Pn_min*  = qh*G*Cp_min ­ qin*(­GCPi)         OH = Overhang   X = Dir along Ridge   Y = Dir Perpendcular to Ridge  Z = Vertical           * The smaller uplift pressures due to Cp_Min can become critical when wind is combined           with roof live load or snow load;  load combinations are given in ASCE 7         + Pressures Acting TOWARD Surface          ­ Pressures Acting AWAY from Surface    Components And Cladding (C&C) Calculations per Ch 30 Part 1:    EHt       = Eave Height                                                     = 12.000 ft    RHt       = Ridge Height                                                    = 13.375 ft    h         = Mean Roof Height:  0.5*(EHt+RHt)                                = 12.688 ft    Zh        = Mean Roof Height for Kh:  h + Base_Dist                         = 12.688 ft    Kh        = Since Zh<15 ft [4.572 m] ­­> 2.01 * ( [15 ft or 4.572 m] / zg)^(2/Alpha)= 1.030     Kzt       = Topographic Factor is 1 since no Topographic feature specified  = 1.000     Kd        = Wind Directionality Factor per Table 26.6­1                     = 0.85     GCPi      = Ref Table 26.11­1 for Enclosed Building                         = +/­0.18    LF        = Load Factor based upon ASD Design                               = 0.60     qh        = (0.00256 * Kh * Kzt * Kd * V^2) * LF                            = 41.19 psf    LHD       = Least Horizontal Dimension:  Min(B, L)                          = 11.000 ft    a1        = Min(0.1 * LHD,  0.4 * h                                         = 1.100 ft    a         = Max(a1, 0.04 * LHD, 3 ft [0.9 m])                               = 3.000 ft    Wind Pressures for C&C Ch 30 Pt 1    All wind pressures include a load factor of 0.6    Description Zone  Width  Span   Area   1/3    Ref     GCp    GCp      p      p                                               Rule   Fig     Max    Min     Max    Min           ft             ft     ft    sq ft                                psf    psf       ­­­­­­­­­­­ ­­­­  ­­­­­  ­­­­­  ­­­­­  ­­­­  ­­­­­­  ­­­­­  ­­­­­­  ­­­­­  ­­­­­­     D­1          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47     D­2          4    3.000  6.800  20.40   No   30.4­1  0.945  ­1.045  46.36  ­50.47        Area     = Span Length x Effective Width        1/3 Rule = Effective width need not be less than 1/3 of the span length        GCp      = External Pressure Coefficients taken from Figures 30.4­1 through 30.4­7        p        = Wind Pressure:  qh*(GCp ­ GCpi)  [Eqn 30.4­1]*        *Per Para 30.2.2 the Minimum Pressure for C&C is 9.60 psf [0.460 kPa] {Includes LF}