Evaluation Report 9020.04.15-114
FL16724-R6
Date of Issuance: 04/29/2015
Revision 4: 08/10/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code and
6th Edition (2017) Florida Building Code, High Velocity Hurricane Zone sections noted herein.
DESCRIPTION: Henry Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. MEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO ETC, LLC Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
'sue + rt etC 'i The facsimile seal appearing was authorized by Robert
•+`+ZSyy?ate¢. ;.•' Nieminen, P.E. on 08/10/2018. This does not serve as an
,�,++•. +a " electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Henry Roof Underlayments, as produced by Henry Company LLC, have demonstrated
compliance with the following sections of the 61 Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
Section
Pra a
Standard
Year
1507.1.1, T1507.1.1, 1507.2.9.2,
Physical Properties
ASTM D1970
2015
TAS 110
Me
IN
F
MEN N
gniint
Examination
Reference
Date
PRI (TST 5878)
Physical properties
HGC-029-02-01
08/31/2004
PRI (TST 5878)
Physical properties
HGC-030-02-01
08/31/2004
PRI (TST 5878)
Physical properties
HGC-140-02-03
09/07/2011
PRI (TST 5878)
Physical properties
HGC-270-02-01
08/25/2016
ICC-ES (EVL2396)
IBC compliance
ESR-1930
03/01/2017
UL, LLC. (QUA 9625)
Quality Control
ML File No. R16814
12/26/2015
UL, LLC. (QUA 9625)
Quality Control
Service Confirmation (ON)
02/14/2018
UL, LLC. (QUA 9625)
Quality Control
Service Confirmation (TX)
07/12/2018
4.1 Blueskin® RF 200 is a nominal 40-mil thick, film -surfaced, self -adhering SBS modified bitumen roof underlayment;
MEMO ETC, LLC Evaluation Report 9020.04.15-R4
Certificate ofAuthoriration #31455 6T" EDITION (2017) FBC NON-HVHZ & HVHZ EVALUATION FL16724-R6
Henry Roof Underlayments; (386) 747-7179 Revision 4: 08/10/2018
Page 2 of 4
Bluesking RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTT" Sand Surface Self -Adhered Underlayment shall
not be left exposed for longer than 30-days after installation.
5.3 HVHZ Jurisdictions:
5.3.1 Fire classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.3.2 This evaluation report is for prepared roofing applications. Minimum deck requirements shall be in accordance
with FBC HVHZ requirements.
5.3.3 Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTT" Sand Surface Self -Adhered Underlayment shall
not be applied over an existing roof membrane as a recover.
5.3.4 Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTT" Sand Surface Self -Adhered Underlayment shall
not be left exposed for longer than 30-days after installation.
5.3.5 Refer to prepared roofing system FBC HVHZ approval documentation for listed approval of this product with
specific prepared roofing products. Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTT"" Sand
Surface Self -Adhered Underlayment may be used with any FBC HVHZ approved roof covering noted in Section
6.3.1 where the underlayment is specifically listed or where ASTM D1970 underlayment is listed, with proper fire
classification documentation and subject to Henry Company limits of use.
6.1 General:
6.1.1 Henry Roof Underlayments shall be installed in accordance with Henry Company published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.1.2 Re -fasten any loose decking panels and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application and prime the substrate (if applicable).
6.1.3 Install self -adhering underlayments when ambient and surface temperatures are minimum 40°F and rising.
6.1.4 Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTT" Sand Surface Self -Adhered Underlayment
perform as a vapor barrier. Roof system design shall comply with ventilation requirements of the applicable
Building Code.
NEMO ETC, LLC Evaluation Report 9020.04.15-114
Certificate ofAuthoriration #32455 6TH EDITION (2017) FBC NON-HVHZ & HVHZ EVALUATION FL16724-R6
Henry Roof Underlayments; (386) 747-7179 Revision 4: 08/10/2018
Page 3 of 4
ONEMOletc.
6.2 1 Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTT Sand Surface Self -Adhered Underlayment:
6.2.1 Non-HVHZ Jurisdictions:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the
type of prepared roof covering to be installed and Henry Company published requirements.
6.2.2 HVHZ Jurisdictions:
Approved Assemblies:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32-inch plywood or wood plank
System Type E: Base sheet mechanically fastened to deck, underlayment adhered
Base Sheet: One or more plies of ASTM D226, Type II or ASTM D2626 with a minimum 4" side lap and
6" end lap mechanically fastened to deck with FBC HVHZ approved nails and tin caps
spaced 6" D.C. at the laps and 12" o.c. at two (2) staggered rows in the field of the sheet.
Underlayment: Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILTI Sand Surface Self -
Adhered Underlayment, self -adhered in accordance with Henry Company published
instructions.
Surfacing: FBC HVHZ approved asphalt shingles, wood shakes and shingles, non-structural metal
panels, metal shakes and shingles or quarry slate, subject to Henry Company limits of use.
Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard® or TRI-BUILT'" Sand Surface Self -
Adhered Underlayment shall not be used as a roof tile underlayment.
r M r T1 As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and shall contain the labeling requirements of the QA entity noted herein.
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 CIA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant
Specification
Product Us
Garland, TX
ASTM D1970
Eaveguard", TRI-BUILT"" Sand Surface Self -Adhered Underlayment
Petrolia, ON, Canada
ASTM D1970
Blueskin® RF 200, Blueskin® PE 200 HT, Eaveguard®
UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@ul.com
UL LLC — QUA9625; (631) 546-2458; Kanchi.Aerawala-Dokania@ul.com
- END OF EVALUATION REPORT -