Certification for Design Load Compliance
Project Name: Lot 8, Diamond Sands, Stanford Res.
Project Address:
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1.. DESIGN CODE: Florida 2017 Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): x Enclosed _Partially Enclosed _Open
3. Risk Category: _I x II _III IV Exposure Category: _B _C x D
4. Design Wind Velocity 170 mph _ASD x LRFD End Zone Width: 8 ft
5. Mean Roof Height 40 ft Roof Pitch: 5.5 :12 Parapet: none ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: see plans Zone 2: see plans Zone 3: see plans Zone 4: see plans Zone 5: see plans Garage: see plans
7. Design Loads: Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 50 PSF
Dock: none PSF Deck: 50 PSF Stairs: 60 PSF Fence: none PSF Railings: none PSF
8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: Piling PSF Soil Test Reports Submitted? x Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the pplicable structural portions of the building codes currently adopted and enforced by St. Lucie
\%I IIII
County. \1\5I� �rtwi y ' ;uc ural elements depicted on these plans provide adequate resistance to the design
forces! d:• :... , �.
�� \GENSF' •�,L'� Robert E. Agsten III PE 43205 CA 8340
_ 205 Print Name Cert # & Co. Cert Auth.
AllAgsten Engineering, Inc.,
ilg�R lre, D`at p � aI
Revised 1 7#�P>a��
3000 Florida Blvd., #206, Delray Beach, FL 33483
Company Name & Address