Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Lot 8, Diamond Sands, Stanford Res. Project Address: Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1.. DESIGN CODE: Florida 2017 Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): x Enclosed _Partially Enclosed _Open 3. Risk Category: _I x II _III IV Exposure Category: _B _C x D 4. Design Wind Velocity 170 mph _ASD x LRFD End Zone Width: 8 ft 5. Mean Roof Height 40 ft Roof Pitch: 5.5 :12 Parapet: none ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: see plans Zone 2: see plans Zone 3: see plans Zone 4: see plans Zone 5: see plans Garage: see plans 7. Design Loads: Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 50 PSF Dock: none PSF Deck: 50 PSF Stairs: 60 PSF Fence: none PSF Railings: none PSF 8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: Piling PSF Soil Test Reports Submitted? x Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the pplicable structural portions of the building codes currently adopted and enforced by St. Lucie \%I IIII County. \1\5I� �rtwi y ' ;uc ural elements depicted on these plans provide adequate resistance to the design forces! d:• :... , �. �� \GENSF' •�,L'� Robert E. Agsten III PE 43205 CA 8340 _ 205 Print Name Cert # & Co. Cert Auth. AllAgsten Engineering, Inc., ilg�R lre, D`at p � aI Revised 1 7#�P>a�� 3000 Florida Blvd., #206, Delray Beach, FL 33483 Company Name & Address