HomeMy WebLinkAboutNOA; Series 160 Sentinel Aluminium Outswing Glazed Doors with or without SidelitesC�U MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv CGI Windows & Doors, Inc. 10100 N. W. 251e Street Miami, Fl. 33172 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "160 Sentinel' Aluminum Outswing Glazed Doors w/wo Sidelites - LMI APPROVAL DOCUMENT: Drawing No.W13-01 Rev F, titled "Series Sentinel 160 Alum Outswing Door (L.M.I./S.M.I.)", sheets 1 thru of 13 of 13, inclusive sheet 1.1, prepared by Al-Farooq Corporation, dated 01/03/13 and last revised on 02/13/18, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Limitations: 1. See Design Pressure ratings single and double doors in sheet 2, single sidelite in sheet 3 and door mullion in sheet 4. For mulled unit lower design of door or sidelite or mullion shall apply to the entire assembly. 2. See glazing option in sheets 1 and 1_1 and locking hardware options in sheet 9. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable -building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the: expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews 414-1015.04 and consists of this page 1 and evidence pages E-1, E-2 & E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Jorge M. Plasencia, P.E. NOA No. 17-1226.05 Expiration Date: August 08, 2023 Approval Date: February 22, 2018 Page 1 RANDALL E. STOFF-T AgjggyE -- AU03379 AR�-r@jljC,S APPROVED REVISE & REEMP—IN APPROVED A,"CORRECTIED 0 REjECTE-D This revI&I'll; Only far gsrva.ra! vv.3h illo "'u, Q concept of Eno prr JI.- ;N"c'm:70.3n OYRn :'�q Uhl-, rtn�rc-ct Fin c d"o C. " I "1..C- ra.o.j, 0, m ci:." of sS.Ap"proval 0I a EpiSM"ll; stain SNall not .y of whidi I; teeth c-3.11ponar., Con I trw-zlc-r is fc.r. Llijfir,�kejls to be coElftened and cc:T,211'ated at the 0s; U&I-Mailion Lhat perLnlns smlejy to to fabelc p a;0.1 t, rcceKses or to U10 iw�lays, methods, tt;�chnjquas, sequenc—es and procedures of conshc- a!! other trades: and for p8rfoirining all work in a safe and satisfactory Mannar. -- DATE iLI23— BY. MIAWDADE MIAMI-DARE COUNTY , f PRODUCT CONTROL SECTION " 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599, NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy CGI Windows &' Doors, Inc. 10100 N. W. 25" Street � Miami, Fl..33172 SCOPE: This NOA is being issued under the applicable rules and regulations• governing the use of construction materials. The documentation submitted has been reviewed and. accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas "other than Miami Dade . County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of ' such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is'.determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "160 Sentinel' Aluminum Outswing Glazed Doors w/wo Sidelites - LAU APPROVAL DOCUMENT: Drawing No.W13-01 Rev F, titled "Series Sentinel 160 Alum Outswing Door (L.M.I./S.M.I.)", sheets 1 thru of 13 of 13, inclusive sheet 1. 1, prepared by Al-Farooq Corporation, dated 01/03/13 and last revised on 02/13/18, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Limitations: 1. See Design Pressure ratings single and double doors in sheet 2, single sidelite in sheet 3 and door mullion in sheet 4. For mulled unit lower design of door or sidelite or mullion shall apply to the entire assembly. 2. See glazing option in sheets 1 and 1_1 and locking hardware options in sheet 9. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. - RENEWAL of this NOA shall be. considered after a renewal application has been filed and there has been no change in the applicable.. building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date 'or ifthere has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded, by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building'Official. This NOA revises and renews # 14-1015.04 and consists of this page 1 and evidence pages E-1, E-2 & E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Jorge M. Plasencia, P.E. MIAMMADE COU NOA No. 17-1226.05 Expiration Date: August 08, 2023 �" bZ'+blZv i Approval Date: February22, 2018 Page 1 CGI WindowsDoors, NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1.' EVIDENCE SUBMITTED UNDER PREVIOUS NOA'S A.' DRAWINGS L. Manufacturer's die drawings and sections (submitted under files below) 2. Drawing No.W13-01 Rev D, •titled "Series 160 Sentinel Outswing Doors", sheets 1 thru of 11 of: 11; inclusive sheet '9.1-, prepared by Al-Farooq Corporation, dated 01-0343 and last revised on AUG 05,12015, signed and sealed by Javad'Ahmad, P.E. B. TESTS (submitted under file #13-0226.06) 1. Test reports on: 1) Air Infiltration Test,'per FBC; TAS 202794 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94(+50.0 PSF, sill S-I only) l 4) Large'Missile Impact Test per-FBC, TAS 201-94 i 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with manufacturer's parts and section drawing marked -up drawings of aluminum out w/ sidelites, by American test Lab of South Florida, Inc., Test Report No. ATLSF-1218.01-12 dated 02/11/2013, signed and sealed by Henry Hatem, P.E. 2.' Test reports,on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with manufacturer's parts and section drawing marked -up drawings of aluminum sidelites, issued by Certified Testing Lab., Test Report No. CTLA 3056WC (sample #3) dated 04/16/2015, signed and sealed by Ramesh Patel, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014 (511 Edition), prepared by Al Farooq Corporation, dated 10/06/2014, 05/19/15 and last revised on AUG 04, 2015, signed and sealed by Javad Ahmad, P.E. 2. Glazing.complies w/ ASTME-1300-02, -04 and -2009. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS . I • 1. Notice of Acceptance No. 11-0624.02 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Sentry Glass ® Interlayer", expiring on 01/14/17. 2.' Notice of Acceptance No.12-1231.10 issued to Eastman Chemical Company(MA) former Solutia Inc.. for "Saflex clear & color glass interlayer", expiring on 05/21/16. 3. Notice of Acceptance No. 124231.08 issued to Eastman Chemical Company(MA) former Solutia Inc. for "Saflex CP-Saflex•& Saflex HP composite interlayer w/ PET core", expiring on 12/11/18. Jorge X Plasencia, P.E. Pr duct Control Unit Supervisor NOA No 17-1226.05 Expiration Date: August 08, 2023 Approval Date: February 22, 2018 E-1 CGI Windows &'Doors, Inca NOTIMOF ACCEPTANCE: EVIDENCE SUBMITTED F. , "STATEMENTS 1 1. Statement letter of conformance to FBC 2014 (5t' Edition) and letter of no financial interest, prepared by A1'Farooq Corporation; dated 09/23/14, signed and sealed by Javad Ahmad, P.E. 2. Lab compliance and addendum letters, as part'of the above referenced test reports.. G. OTHER 1. This file.NOA revises # 13-0226.06, expiring 08/08/18. 2. Test proposals approved dated 12/16114 & ## 12-0553, dated 04/25/12 approved by RER. 2. NEW EVIDENCE SUBMITTED A.'. DRAWINGS 1. Drawing No.W13-01 Rev F, titled "Series Sentinel 160 Alum Outswing Door (L.M.I./S.M.I.)", sheets 1 thru of 13 of 13, inclusive sheet 1.1, prepared by Al-Farooq Corporation, dated 01/03/13 and last revised on 02/13/18, signed and sealed by Javad Ahmad, P.E. B. TESTS 1: Test reports on: 1) Air Infiltration Test, per FBC, TAS 202 -94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with manufacturer's parts and section drawing marked -up drawings of aluminum out w/ sidelites, by Fenestration Testing Laboratory, Inc., Test Report No. FTL 17102 dated 05/19/17, signed and sealed by Idalmis Ortega, P.E. ; C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 60' Edition (2017), prepared by Al Farooq Corporation, dated 11/13/17, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies w/ ASTME-1300-09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). urge NL Plasencia, P.E. Prod t Control Unit Supervisor NOA No 17-1226.05 Expiration Date: August 08, 2023 Approval Date: February 21, 2018 E-2 CGI`Windows &Doors, Inc.... NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS' 1. Notice of Acceptance No.17-0808402 issued to Kuraray America., Inc. for their "Sentry Glas® (Clear and White) Interlayer",'expiring on 07/04/23.` 2.- ". Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their" "Saflez Clear-& Color glass Interlayers", expiring on 05/21/21. 3. Notice of Acceptance No: 17-0712.03 issued to Eastman Chemical Company (MA) for their, "Saflez CP-Saflex & Saflez 11P Composite Glass Interlayers w/ PET Core", expiring on 12/11/18. 4. Notice of Acceptance No.17-1114.14 issued to Kuraray America., Inc. for their "Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers", expiring on 07/08/19. F. STATEMENTS l . Statement letter of conformance to FBC 6th Edition (2017) and of no financial interest s prepared by Al Farooq Corporation, dated 11/13/17, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. This NOA revises NOA #14-1015.04, expiring on 08/08/18. 2. Test proposal #16-0947,. dated 07/26/16, approved by RER. orge M. Plasencia, P.E. Prod ct Control Unit Supervisor NOA No 17-1226.05 Expiration Date: August 08, 2023 Approval Date: February 22, 2018 , E-3 MIES SENTTN .. 100 AT1JAfINLTM OIITaWTNEC DOOR W/ SIDELMS APPROVAL APPLIES TO SINGLE (A) AND DOUBLE (Rx) LEAF DOORS WITH OR WITHOUT SIDELRES. SIDE LUTES CAN BE ON ONE OR BOTH SIDES OF DOOR. DOORS WITH STANDARD THRESHOLD APPROVED FOR INSTALLATIONS WHERE WATER INFILTRATION RESISTANCE IS REQUIRED. DOORS WITH SADDLE (ADA) THRESHOLD NOT APPROVED FOR WATER INFILTRATION RESISTANCE 3/16- ANN. CLASS 3/16- HEAT SRRWD GLISS - v Z x E$ D75 S,Oec CP WCN PET Con 075' SWI. CP With PET Cam 0 w By 'Fanbmn C MI-1 Ca,' By'E..— CMl Co.' F H a. 6 D e S.O. CH,r Md Coler Cl.. .090- S9 - 0— Md C 1. C— INTERIAYEINS By Et—, CNemlcd CO.' INIFRCAYERS By'E,aeTHW Clwmk,l a 09v Senby— 030' Sadrhlae By 'K,mmy MxrfeD, YW.' By 'Kummy A .K- IM' p A90' TmWAI PYB .090' lr elfa PNB 0 y SY'Kummy Arn . , NO.' By'Kw9my ft,O . I..' (i D 3/1C ANN. GIAS9 3/16- HEAT SINEN'D GIAS6 D 5�� SIDM D d lqe 995 DOWBIL 995 U SL 698 P� G GE-12D0 GE-1200 -12 GE-12 q .LL W b 0 DOj yy'ILL. ja 0 a 0 .. \ \ 0 9 W AT 1/4 POINTS 0.T AT 1/4 POINTS p .GASS.TYPE d GLASS TYPE 'E' C 0 7/m. ONFRAl1 VN. QA59 7/1,- WDVdl UAL cIASS $ ; IgN GLAZING OPTIONS THIS PRODUCT NAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6IH EDITION) FLORIDA BUILDING CODE , INCLUDING HIGH VELOCITY HURRICANE ZONE (HVIM. ISY OR 2BY WOOD EUCNS k BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPUED PRODUCT LOADS TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSION RESISTAM, SPACED AS SHOWN ON DETAILS INSTRUCTIONS - AND INSTALLED PER MANUFS INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL HALL BE BEYOND WALL DRESSING OR STJCCO. USE CeNRR FOUDWS A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. STEP DEIERMNE DESDH POND LAND RMUWEMEM EASED ALL STUNS TO BE HIGH IMPACT, NON-METNLC AND NON-COMPRESSIBLE.ON WIND VELOCITY, SLOG. HDCHT, WIND ZONE MATERALS INCLUDNG BUT NOT LIMITED TO SIZEL/METAL SCREWS. THAT COME INTO CONTACT WITH OTHER DIBGLWLAi MATERWS SHAL MEET THE I19ND APPl1GB1E ASCE ] STANDWp. SINGLE GO AND DOUBLE OLIO DOCR WACMES STEP 2 FOEE REQUIREMENTS OF TKE 2017 "RIM BLDG. MOE K ADOPTED STANDARDS. SHEET 2R S.. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION STEP 3 FOR SIDEL E PANEL (0) OIPACTY SEE SHEET i FOR A SITE SPECIFIC PROJECT, L.. LIFE SAFETY OF THIS PRODUCT, ADEQUACY SEEP FOR 90DDDR DE MOW N WITH D b OF STRUCTURE FE SVING THIS PRODUCT AND SEAUNG AROUND OPERNG FOR WATER INFILTRATION RESISTANCE ETC. SEE MUUX)N WWAY CHART ON SHEET 4. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY. AND TO BE REVIEWED BY BULLING OFFICIAL STEP B THE LOWEST VALUE RESULTING FROM SRPS 2. 3 AND 4 S LL — TO ENDRE SYSTEM. 3o A 0 PRODUCT REVISED �I P I With th, Fkdd, BulldinB R e S NOA-No, 17-1226.05 re E ,J.11,a 0,f, 08J08J2023 gg15 E3 D _ Q d )MUTES ARE RATED FOR LARGE AND SMALL MISSILE EIPACT. ARE NOT REQUIRED. 9 7i = IT 111 ` 1\\III llllllyyy �.- , •.. F®1 b 21118 � 93;,, IO q Z ; Sgae a ° off 3/16• TEMPERED CUSS 3/16' TBAPMEO CLASS 3/16' TFMPEREO GLASS a Jf8' AIR SPADE 3/8' FIR SPME 3/8' AIR SPACE Ica 3/16' ANNEN.ED CLASS 3/16' ANNEALED GLASS _ 3/16• ANNEALED CLASS 0 O90' Infedayer O75' Inter)vvyyee r Ow SGnbya., „ SORu Oeor /od Ctl4r Goan Svflex fP W�ItIr PEr Core 2JfENUYERSy By Kurmay Amenea, Me.' 6y 'Evdm9n chad tl Co.' By 'Faa6lon C1lemie9l Ca.' .090' T.Vu M By 'Kararoy -.e , M., d 1-3/16' HEAT SMEWD CUSS �3/1W HMT SfiRlb CUM 3/16' HEAT SINENID GLASS o I mm" SRICONE SILICONE yg G GOWSIL. 9B5 COWS 9B5 Dow 05 OOWSIL 899 DOWSIL 899 DOWSIL 899 CE-1200 GE-1200 GE-12M C • m 3pp b� � O1z�N ye 12 F 13 O 3 ML EDGE SPACER ... .. i \� & EDGE SPACEi _ .... �.2.._ mGE SPACER z I ON STEEL B!'CAROINLL' I � SEEL BY 'CAROINN' I ST. STEEL, By'CARGINAL' o g 1 oF��SY'OL�IX OURAsm BY 'QU Ex' ` OR apRASEeL 8y GW1F](' o� SUPER SPACER BY'CILWE%' \ / SUPER SPACER BT'OUWIX / SUPER SPACER BY 'OWNIX \\ / OR \ / OR \ / OR KOCISPACE 4SG TPS BY 'KONNERINEG' KOBISPAGE 4S0 TPS BY 'NUYKERLIHG' KODISPACE 450 TPS BY 'KOHNTRLING' 33 AT 1/4 POINTS SJ AT 1/4 PO. W AT 1/4 nINIS L CLASS TYPE 'Cl E:TA. a TYP . 'CM' GTASS TYPE 'CS' qq 1' O1fW11 INML M. GLASS 1' Cvu l OISIIL LAN. GLASS 1' OVERALL 01SUL L.11L GLASS � 2 PRODU�C�nTgREVISED 6Wimr9 CotloMN tlI� Flodea NOA-Na 17.7228.05 ., GLAZING OPTIONS e.PTlaBaa Baw OWOM023 11 \ LI 11I y u FEB 15 2010 ?�� Sze,' e -* ;` '•EEnsn�,, - s � g � '• t>F %K�' drawing na. W13-01 1 HEAD ANCHORS OUNHDIY AT ME ENDS ANCWR TYPE SHN 'A' 'B' '0' 42' 2 ANCHORS 81 1/2' 1/4' 4 4 . A DOOR FE WI RADTH TYPE 'A', '6' OR 'C' DOOR FRAME WIDTH 3/8' 6 6 6 AT SIRE ENDS 1/2' 7 7 6' MAX. SEE CHART FOR QUANTITY- 3' HEAD/9LL 3' 6' ]' HINGES HINGENCTS CORNERB A SFE INOOTE A SEE NOTE Lpy SEEBIlAW _ _ BELOW IJ !_ 1 / I,\ s II ACTNE / / i [IOLT SDET AAAJJJIII` E & sEE MIST 10 1 II \\ ar ACTIVE 3E2. 1/4' m 8 O.L OFG 2 ANCHORS TYPE 'B'SURFACE AT STILE ENDS DL OPG. 28 1/4' 2AFALSE PLED TYPE 'D SURF NUMINS SINGLE OR DOUBLE ODORS WITH SADDLE (ADA) SILL AT SIRE ENDS MAY BE USED TYPICAL ELEVATION _ ( X ) DOOR OPTIONS TYPICAL ELEVATION ( XX) 4'XBINGES1/ 70P AND 1/BOTTOM WNIGES AT 6-7/8' FROM FAGI END INTERMEDIATE HINGES EQUALLY BPACEO �v D ro '_ Z 3 o S. 0 °o H`1 r o�Dg O Ohs H, Rail0 c 8 c Nn 3 n.l g C3om LOCK SM, SCH . SCHLIGE ((3)) HNOES PER LEAF UPTO 35' LEAF W1D71L5 (STD. THRESHOLD ORLD (4) HINGES PER LEAF ABOVE 35' LEAF WIDTHS (SM. THRESHOLD) CC - CAPPER CREEK i4) HINGES PER IFAF All WIDTHS (SADCE TfRmNOLD) 0 = PLO - RALDWN D GLASS INSULATORS o R 4 tl M : ��' XL 42' 81-1/2' 06' 39-3/4• BOA Imo BOIL 80.0 70.0 70.0 60.0 - NOD - KODISPACE CLAN - GUM OURASEAL 1' Y13I....YYYA Iw •• H01=• VERIFY COMPLIANCE WITH EGRESS UMRATIONS WHERE REOUIREO. GUDNEX SUPERSPACER P�''• FEB1 5 1E18�D���'-..0����: A ' Y q g NOTE: PRODUCT REVISED ' OLSH BOLTS AND LOC6 MST BE ENGAGED TO HEAD AND SILL DURING y1 y MM N. FI9Hd. NOTE: PERIODS OF HURRICANE WARNNG. Bulidlnp NOA-No. 17.1Z28.05 d..JN no. w)3-0� GLASS CAPACITIES ON THIS SHEET ARE DDOR pi 0 DIMS. RASED ON ASTM E1300-09 (3 SEC. GUSTS) D.L.O. HEIGHT - FRAME HEIGHT - 12.875" FRAME WIDTH 13.75' ZI:U- t0081O8T2023 •(' � ,'A��•��,N, AND FLORIDA BUILDING CCMMISSION DECLARATORY STATEMEM DCAOS-DEC-219 D.L.O. W1DT11 (X DOORS - - D.L.O. WIDTH (KX DOORS) - (FRAME WIDTH - 25)/2 n� T �;,, G`�� enema 6TNCLS (I) OR IgVBIB (OR) DOOM TOAD CAPACITY - 4 P&P CUSS TYPES W. 'B'• 'C1'. 'C2' k 'C3' FP.WE WON N[I1H HDGM IFi.F WIDTH 1HRESIHON TYPES l0IX SETS INSUL GIA4 SPACERS M. fIM SON CC 9LDW IXL KOD OIMN 37-1/4' 72' aD.O J0.0 BJ-0 80.0 8a.0 BD.O 80.0 80.0 165 1/2' W. 1/4 4 4 - �% pwM O a �3 Ogo� iq IILL O G e aOr FA51°/ERS SAME LOCATION AS ARC %R OR SHEET 2 VV� -_ - O.L OPC. m G / 281/4- TYPICAL NA770N O.L OPG. D.L OPG. 1 DPO. 6L DPc. • C O I 4 ANCHORS SUWAGE APPLIED TINS SIDELITE LOAD CAPACITY - PSF TYPICAL ELEVATION IYPE'9. FALSE LISED OR SEAND MNS 9TA77ONADY PANEL (0) O%%0 AT STLLE AND MAY DE USm ry Cl/aa lYiES C .ee TYPE 4T.LS5 TtPE C MULLION ENDS A FRAME A' g CI' CY w' eDTH -BHT E1TL+ IRr- TWO-0 W. ADO.(+ an.-) SIDELITE OPTIONS €ITRSS JD• e0.0 a0A a W.0 BOD F HOLE c ¢ yy y W.0 WX O0 80.0 eoD I THE FRAME AREA OF ALTERNATE 50. MUSE T. 5 3fi' 81' B0.0 80.0 0.0 80.0 BOD EXCEED TESTED FRAME AREA a ttD.J SO. FT. -1/B' WA BOB .o W.0 60D GIAC9 INSL nTOR MTATION9 FOR 9DELIDS JY' BOB 80.0 0.0 W.0 W.0 WIOER THAN 37-1/8' ONLY. 12' W.0 W.0 O Boa BID 9O' GLASS HEI9H15 a - FOR GU33 TYPES 'C2'- 30' BO.o BOB D 80.0 aOD OVANEN OURASFAL A SUPERSPACEB NOT ALLDMEO Lo e v 80.0 eo.o .D 80.0 eo.o FTxt cuss TYPE 'w' JB• a0' 80.0 -0 BOBO 80.0 a0.0 CARDINAL IQ (LIMO MAX LOADS M :7o.O PSF) ` A1111111 TTIT/ 5, -1/8• 80.0 BOB .0 ao.a e0.0 ? JB• eo.o B/.o ®.o ea.B ao.0 eo.0 - FES 1 5 all � � - 42' - - roo 70.0 ao.o 80.0 PRODUCT REVISED OO• aB.O W.O W. W.0 60.0 W.0 TnPlNy�lppu� wIN t115 A9dQa y y r' JJ' a0.0 80.0 W.o e0.0 a0.0 W.0 BUllmnp _* • * $ � d 5 NOa-No. 17-1226.05 , a��A• JB' 96' W.0 6 0.0 BOO a0.0 80.0 W.0 SILO H DLO. DIMS. droning n9 -1/B• ea.a 80.0 BOO Ba.o BO.O B/.a D.LO. HE1GM -FRAME HEIGHT - 12.875' PsplA0o5 Dab 0810812023 roA ]0.0 a0.o Boa DLO. WIDTH 9DElRE WIDTH - 6' STAND ALONE SIOELLTE ONLY pY A Ais"•• • •\ W� TJ-(]� -w.n inn inn nnn D.L.O. WIDTH SIDELNE MOTH - 4.875 SIDELITE TO DOOR ONLY 1 H H SIDEEIIE WIDTH - DOOR FRWE MOTH SIDELRE WIDTH SEE CHART FOR CUANnTY HEM ANCHORS QLtANT IY 61 MAX 3• e• J• AT RAP" MUWON ENDS HGD/SILL FQ -i ANCHOR TtPE 2 i CORNERS F A _ 9DM •A' 'ET •O 6' `qqO 0 §' j 4 O 7L c m9 1 t�i I BO L BETAR � ��✓ g /• -/ J SEE dIN LOCI( SHEET 10 '�ff1� =----tt=Fri --- - --- i •� Jd l I \ ---�L-- C --- \ 1 Y I I II ' II ACM ONCTWE _ DRSLGN LOU CAPACOY - FSP SOEIIR WETIH ODOR UL MON SOONE FAME 1ECNT S1D&JT8 2O DOOR YVIlION (yE NOIC BF]OW) NCHES NCKES EICFIO Dm(4) INL(-) 2{ BOA 80.0 ]0 BOA BOA 80.0 804 33 ]0 ]9-3/4 B{ BO.D BOA BOA DOA 37-1/8 39 89.0 BOA 42 80.0 BOA 24 BD.O BOA ]0 BOA 80.0 80.0 "A m So 9-3/4 90 BOA BOA BOA WA a7-1/0 80.0 .0 Mao 42 80.0 80.0 24 fl0.0 BOA 39 NA 80A 80.0 60.0 ]] ]B ]9-3/4 90 78.3 78.3 'n 77.x 37-1/8 39 42 72.6 1 72B D" DOOR TRANS SNEUTE SMEUTC rRWE SDELTIE DOORSIDEVIIE FINER Wlmll MmH MDTH WUTH mmH mm MOTH WIDTH C N Hj N C \ C '/ '/ \ K J \ \ KfG/ (%001() (00)__' `_(NOR)`_• () S0T1RE ODOR FRAME SOEUIE DOOR FRNE SRTIIRE MmN MmN WINK MUTH WIDTH . H J A \ MUWON� J( XD%%%D) `DOOR ou ` ' ( DUO) ' END ANCHORS %) END ANCHORS EE O OJ SSKEET 3 SEE SHOEr 1 F/F MOTH SIOEl1TE MmH DOOR iR4YE h1mH ' SNDIE (%) 42' LLA2. DOUBIE DOT) 81-1/2' YA%. S)DELM TO DOOR NOTE: GLASS CAPACOES ON THIS SHEET ARE EASED ON ASTM E1300-09 (3 SEC. GUSTS). NOTE' AND FLORIDA BUILDING COMMISSION FOR DOORS CAPACITY SEE SHEET 2 DECLARATORY STATEMENT DCA05-DEC-219 FOR SIDEUTE CAPACTITES SEE SHEET 3. FOR SIDEUTE MUON CAPACITY SEE CHART ABOVE W LOWER VALUES FROM DOORS, SDEEOE, DOOR/SIDELITE � �.... z' OR DOOR/DOOR MULLION CHART MUL APPLY TO ENTIRE SYS031. NSF '••�/�� PRODUCT REVISED e: "—Ap '�9d" •'^th th. FIBaa. FEB 1 5 2018 NODE-N.. 97-1226.OS BKPTT.00n D.t.08108=3 OF 'S4/ - Bra`N9 Ro• R � W13-01 TAd .ae r F�AIAl.1{� ah.ot 4 of 1; N APPROVED FOR WATER INFILTRATION RESISTANCE EA n .R (ADA) THRESHOLD NOT APPROVED FOR WATER INnMAAON RESISTANCE DOOR DETATT C OMIT MAX DESIGN LOADS TO 370.0 PW �v 0 ro mp; F Ogg m�I= V ='n 0 g9.6 0abE 0 y D 12 ao v3 PRODUCT REVISED plelmt fm Oro Florldn Bu0alnp CooQQ � tt NOA Na 17�1228.as e g ExpNwlbn O O3108M023 g n R L m MI ee, Con e d �eaB y FEB 1 51UIB "' ' �..!!.... OF O ; moo,.° p 8 5 i d v wing was—oi BUD( SEE OIESEE NOTE SHEETt Olsf. . DNCR9E %„ �.� • N TYPIdL ANCHORS SEE DMAGONS TOR SPACNO WOOD BUCKS AND METAL STRUCTURE NOT OY CGI WINDOWS MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE TYPICAL ANCHORS: SEE 02Y. MR SPACWO TYPE 'A'- 1 /4' IYA. III TRACON By 'El CO' (Fu-177 IS. 6-155 N51) MIN LENGTH 2-3/4' INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2' MIN. PENETRATION INTO WOOD (HEAD/JAMBS) THRU TV BUCKS INTO CONIC. OR BLOCKS 1-3/4' MIN. EMBED INTO CONCRETE (HEAD) 1-1/4' MIN. EMBED INTO CONC. OR BLOCKS (JAMBS) TYPE 'B'- ULTRA2-3 4 'fY 4 (Fu- W = Fy-155 KS) MIN LENGTH - 2-3/' DIRECTLY INTO CONC. OR BLOCKS 1-3/4' MIN. EMBED INTO CONCRETE (HEAD/SILL) 1-1/4' MIN. EMBED INTO CONIC. OR BLOCKS (JAMBS) TYPE •C'- 1/4' DIA TEKS OR UE1 DRIWNG SCREWS (OWE 5 ORS) INTO MWAI-DACE COUNTY APPROVED MULLIONS OR INTO METAL. STRUCTURES (HEAD/JAM135). (3) THREADS MIN. TO E7(TEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) STEEL 1/0' THK. MIN. (Fy - 36 KSI MIN.) (SRR IN WWN WDH AUIWNUM TO BE PLATED OR PARTED) TYWCAL EDGE DISTANCE INTO CONCRETE AND BLOCKS - 2-1/2' MIN. INTO WOOD STRUCTURE = 1' N. INTO METAL STRUCTURE,= 3/4' MIN. WOW AT HEAD OR JAMBS 50 - 0.55 MIN. CONCRETE AT HEAD, SILL. OR JAMBS PD - 3000 PSI LIM G-W HOLLOW/FuED BLOCK AT JAMBS fm - 2000 PSI MIN. ANCHORS MAY BE HEX OR MT HEAD. 2BY IYODD OXk OR STRUCTURE METAL ,Y SEE NOTE SHEET 1 tEWET. ��'EtOIfSE�A�IEDNOAI___—__-�NOR9TYPICAL ANCHORSEVATIONs SEE ELEVAnWs offal L ANCHORS FOR SPAGNG FOR SPADA'6 -EVAM I� Qu�a� u 2. c 0 vF�eg GNT H $ G M n y3: }o�R Vo.0 PRODUCTREVISED BMRAn¢ 0� ND11-xa '17.1228.05 Gmlmtlo0 Dab 0810812023 Dy NW mauet n FEB1 5 2018 1"" _�. 0U01OFdrawing� ��,,,rl�rxoel a oft: r 1 PRODUyC�T� REVISED �``�Pv: •••'•''' :ul�elnY CoE.MN N. FFED 15 201E _ xoatla �7•�2Z5.mda. 05 _ 'T}❑ e.p�m. o.e.aY Oxrm23 '• ac �Gi d. 0y DOOR DEfAIfS ' �% ••. ?R/ C2: W1 wm ON l�• r IYPM ANCHORS SEE D A1I0N5 �4'V 4 .'•EWE'ORT.:.•. S rOR SMING ° K roRn"ix s`"STE"'E`s �/' 4 45 's �.. iCONMiETi. .... .. :�COdaeTE.', p e SEE DOOR JAMB WADNO 9 C 13 a Oi PRODUCT REVISED tin .lam. rt°.la. ' ' " 4 QYIq tt55 95599 CC EXTERIOR 05 77-1226.OS a S Q EaP4eOm Da°a 08/08MO23 S IFAE WDIN O.L OPO. Ml�jyn a uct now DDOR i1LlME MOIn SIDE= MOfn OW C et 1/2'�MAA.S� e o a Oti 1/2' MAX o ,,..tt c (�• LD/L BEAfpNG. 5/0! '..'• ' O O 1NlING JAMB FASf010i9 Hn�n $ 0 10 o SIM IDGlI01S SEE UYB SPK1N0 9 i MNCAER . le e x OR'' CC +�+� 5 O152 R W .RY .. U �2� A' °WiPp• i 98 x D EXTERIOR � C Di DPa I IrAs wDm ° 8 � � trPlrx ANCNOIq SICENE MDTI DOOR fBAIIE MWH 4' LONO 42' MAX SINOIE SEE M. eI-t/2' MAx. DOOBIE (Aar pp a ° ffi ^ d 41911 = . FOR SPACING ri A,ME WOTH E o 4 ` FES161818 T ±*_ m • OGtlCAEfE; ;'s .a ,• .� s. NOILR SHIM TO MEE/L STRUMURE AT IAMBS TO 3/8- - �K •; s i° 01GE pef. .SIXEAl ANdpRS n.:. \2. �ArJNCD� SIDELiTE DEPAILS `s% i�?` °ilia e� MSIX R 1p�, TTEY PATYC Na. OQAH37TY DESCIUMON 1fA19WL wo, / HYYAR0 %OUNW rJ__-__� ' i'-r---�_----- J ACTIVE IFAP A--{ INACTIVE LEAF _-_ ___ .,III OPEIATION OF DFADBOLT t T M1Rf 12TOR F es - IRROUCIOM FOR) /CIN THE THiiE-POINT LOCK LRCJVJm LOCAWLFS9 6 LOIX SETv. OPTION MSTNIID. SECTION AT DEADSOLT LOCK 1 LO1F IILACIIVE lEK 4 mulwt SECTION AT LEVER LATCH LOCK RRAT.ANER: ALL JOINTS AND FRAME CONNECTIONS SEALED WITH CE SCS2000 SILICONE SEALANT. YY till", Coda IN In 6.05 Y_^ AA,A 17-1228,05 YVYt!:"" '•� „'•• E>aero tTr2oz3 FE81 51010 - '• - 'A�s'• ��R s/OI�It11n 1 AL-109 AS REM. FRWE HEAD d SAL W83-16 KEIIUMK / SWA 2 AL-1W AS REOD. FRAME JWB WST-TB KIENW / SWA O 3 kW Q ` d pI a• O C yz( a 2 �R � i3 $ � v. W 3 k-188 A9 ftEW, SOENE im k SILL WB!-TB HZYWRRK / SWA 4 K-18T M REW. FREE STANDING SIDL111E JM.18 WW-76 IQYWRK / WA 5 AL-195 AS REW. I.ARNO SUELITE JAI® WB TB WYMW / WA 6 7 8 IL-19] IL-19a AL-199 ,V^ RWD. AS RE00. AS PEW. PANEL TOP k BOTTOM PM'FL VF]t11G1 STIE SMEAR FOLK W83-T8 WB!-TB Wei-Te WMARK / SWA KEYMARK / WA MWRK WA e AL- I M REOD. FAAYE MEAD d 581 SCiRV1 COVER 6DU-75 KEYMMtt SARA 10 11 12 13 14 AL-192 AL-121 _ AL-10 AL-- AL-1B! M REOD. FAAADi TWAO k 5'LL 54MED SCREW COVEN Go"-T5 KEWRK / YPA M PEW. AS REW AR REOD. AS RWD. GIA2MC BEAD (!/18. 1AJI1 OIAZINO BFIL (1A00• MUL-1AY.) SNEAK RATE ASTWlJL W83-TS WB]-TB W83-T8 WA7-.T! KEYAARIE I WA mwm / WA KEYYNU(I WA KEYMARX WA 18 18 AL-" AL-SQ AS REOD. AS RWD. FREE VAND -8 SCREW' COVER SADUE TIWESIIDYD (rADA WMRLANf) W63-1S 6DW-13 IAY'LARK / -A I21'LIATM / SARA 17 HD-450lPL M REOD. THREE PANT Lax A55'f. W AMS PAMEL. USW WALL MOMS) MET& W PR PIDLTAO' 18 ND-1204 A9 REOD. EIISH /SS!]MY (/R WL7NE PANEL. USED W AL. DPIIONS) AY1dY. STEEL W PT�PRNEMT � IS - ✓�� p ;s $ N n PIO1 of V �+n j o F 19 HD-BMS5 PASS AS REW. AS PEW. AS REW, LETRR LATCH LOM Al ACTIVE PANEL OUMITY LEVER, AT WINE FMC. DEADBOLT 0MUYBNREQ, AT ACTIVE PANEL LOCK SET OPTION 1 BR/S4 DMAON 20 HO MSS 21 HD- I 22 J10 TORWS AS REOD. AS RWD. AS RWD. LEVER L1101 L" AT ACTIVE PANT]. DUMMY LEVER, AT INALTNE PANEL OFMWLT (THUNBNR"♦), AT ACTIVE PANEL LOCK SET OPRON 2 BRASS SCHV[i 2] JtD T[R665 24 JDW 25 M-3h10118 AS REOD. AS ROOD. AS PEW. IEM IATCN LODE. AT ACIA'E PANEL DUMMY LEAN. AT eUL'INE PANEL DmmT ONU.MW. AT ACRNE PANEL LOCK SET OPTION 3 9RA55. SIFFL. WPPER CREEK 28 HD-34-10115 v HD- 082410 25 HD-S]7 AS RF11D. 1ATCM LOCK STRKE PLUS A "TEFL - 2RA - 2 /PLATE /B % 3/4- PIP. MSMS (MM PUTS ATTMWQO) S STEEL 29 MD-838 AS REOD. DFMBOLT SfPOfE RATE 29A _1 2 /PLATE /8 % !/1• PIP. FX SLYS (41FCI PLATE ATiMMENI) A STEEL - >D No-5lEN AS REW. LAIUI LOUT STRIA PLATE SHM N11DN CCI 31 KPJ90P M RWD. .LATCH LOCK d DUDBOLT STRIKE PLATE TRBA IOlOH W 32 HD-SDONE W% AS RWD. UTUI IDCN k DMWL PROTECINE DIRT SUN MTCN W o o Q 9 O G �I Q gg 9 J w N YE q@ 0 y MD-3TS-8-IRV 2 'NYSa4 BOLT LDCK JSFLA9LY S STEEL W SSV NO-5]3O 1 SHBDLT RIlSN BOLT DIADE (TOP k BOTiDM) CAST (MC) W 34 HD-0H-108 4 ILvr . 1-t/z• a a• Mt1DE AwL1Mw W FROR4ETND' 35 HD-IHA00-UST20 4 /LPK 1-1/2• t 4• MOE BPISs EMGER >D 1�_Ag800-U5 4 /LEAF 4-1/2' a 4' -GE 031W-16 FLLLT THREADED ROD DOW PUTW) 5. STFFL STEM. PAGER 38 11-4,m AS REOD. CIAZUW BIRD (WRIYEIER 75/80) PVC PROTOTYPE W M-YY33T21 K RWD. ' .18T a 320- ULTRA S FM MTHERSMOP - ut:T AB 40 HU-203 21LW SMOOT BOLT PROTECTOR. AT DDOR FRWE HFAO d SLL PrC - 41 MD-12-10042 m RWD. z50• FSaCR POCMEI` SFAI. (FRAME PERdETF3t OA.RKEO - AFIE� 42 V -32011 AS ROOM IMAM -TOE CMOSW CFJL FOW COWPRESSIDN SFAL _ AMESBURY 4] HO-Wp ANGLE 2 /EACH 2 M 2 • 1/4• CLP ANGLE F/'DA TNRE91aD TO JAYS ATTAL lW0`M ALUMMUY -:!'—PRODUCT H 45 _ - ! /CORNER SEE f3.E/. /10 • 1-1/4' FHP. M SMS. (PANG k FFME ASEEMBLY) /14 • 3/4• I0L TIX (MULLION ARACMENr) S. STEEL S. STEEL - PRoouCT111,0.REVISED - BUBdine q 48 - B/T9NGE . 4/0UP /12-24 a 1 2- MP. M TIC. THAFID FOTORNO S. bTFFI. - N04Mo. - TCapTraMon - - .•. —� - m 47 - 2/EMH /8 • W PIP. M .5. (A91MfYt ATMOEY % STEEL 48 - 1/F/CN /10 a 3/4' PIP. PH. SYS (BOLT IMX / iLU5F00LT DUDE AssYJ S. S1EFL a9 W A!/8'-18 AVf - 4 /IFAF 2 /NLSNBOLT 43/11- 5 SERRAM-F1AfFE NUT (SMC HAM) j8-3z a 1/27 PIP. PN. l6 (FlASHBOLT A33E Y) STW. A 51Fd OfOrinq n0. W13—Ol 31 Ill-p00R Sw�IP 1/MH DUOtt SMEFP (DPDONAL). 3IIIRm w /8 a 1/2' PHP. M SYS ALU Nw SCfR£N TEUI 32 HD-]4-taW] t /StlEEW HOIE P6EALATCN — HOLE PLLO (0 DOOR FRNfE "M MI) NYICN - 5] 1 2/ 111E SETDN9 9TDIX5 FROM oul+DLkTER WS5 SHDEE A !n!!L 9 Dr 3 tanwmr<o Nmunne+l+rt OLS9h.141 UNLOCKED POSmON LOCKED POSm0N 0 f' I PRODUCT REVISED e F1IyyII�!�gqMN Na fbrNa � E BVI1dInD �.o4"a �' Ron-1!a �7-7220.05 4 4 4 Wl.th. Date 0810MM3 `�lI11111!!!! u FEB 1 5 2018 F yy� 5. d..In9 no. e �6` W13-01 . I I ! B ill � I - e ■E � ■ § * §oe,w PRODUCT REVISED _ �� ' \ / ) � __ . } ( m--�� -m Mt 2 c7" �\ _ BOTTOM END _m . . IFESI52018 . .�.o. '&¥ƒo 3JW - ,25 5 .750 I.SBa .100 (D DOOR FRAME HEAD/SILL 0 SIDELTTE TOP & BOTTOM FRAM .J28 r em 1 A30 ASTRAGAL ADAPTER ,.010 ,.125 .120 .Ofm 4.000 S00 .125 .120-41 - 2'J58 t323 0 DOOR FRAME JAMB ,.]66 .062 ,.613 .000 130] 4.495 3 SOD O FRAME COVER 1.023 .062 0 TOP & BOTTOM RAIL 10 SILL. COVER olw .465 1.6]H 1.440 .0]3 1.Ofi] 4.495 Q) HINGE & LOCK STILE E U SIDELITE JAMB COVER 123 j'.135 �u 1.SW 1B5 SDO I� .I13 4 uea--I O SHEAR BLOCK 13 SHEAR BLOCK PLATE to SADDLE THRESHOLD 2000 1.Dal 11 1.462 ,020 QO .310 f.1 Bf ow A9� .050 f 4.000 .073 .120 4.OD D GUSS STOP (UaM. GLASS) W5 .O70�IL�- . III LASS 1.465 I .42D .093 .062 .090 200 �0 C C 2 11K SIOELTTE FRAME JAMB SIDELTTE MATING JAMB CLASS STOP TIHSUL LAM. GU PE8 ] 5 2018 PRO�DUC�TREVISED Bu11d4,g MM fM FToddn NOA-Na 17•'1228.05 P.vIntlan O,,n0810812023 m �qb �6 8 w G °3 oa o a O .. o�N80 3 0 n� 03�0 �o_ R U M's wW13-01 Im SIOELRE JAMS CORNER TOP &BOTTOM IB 0 2 r a gg°�Ro 0.05 OR u E $ o � Q=ne $ ONMri �LLR �o a PRODUCT REVISED p lUt Ib flodda BWIMp NOa-No. n � 17.7248.05 F�Tn6-0a 0810812023 BY — FED 1 5 2018 e" Z d § a idrawing rro �,. W13-01