Loading...
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door Assemblies12/8/2017 Florida Building Code Online Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Al Therma-Tru Corporation 118 Industrial Drive Edgerton, OH 43517 (419)298-1740 rickw@rwbldgconsultants.com Rick Wright rickw@rwbldgconsultants.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer © Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL5891 R5 COI Certificate of Indeoendence.odf Standard SSTD 12 TAS 202 Year 1999 1994 hffps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquw6mPlZhp%2fndRcOWkL6ois4lbF6OvZnFg%3d 1/3 AAif003379 APPROVED '�LZD11195 ® REVISE & RESUBMIT ® APPROVED AC- CORRECTED REJECTED This rev1&11§ only for gei,;rat C-rf0„nasCe V✓; f.I 11z design concept off; e protest and general L ^ !;�nC2'Nith B fC ii ' O B g118n I�i the Cantfu"'a doumenFs. Corec,'�ne Cr this rcvie do not reiiav:, omments m e cn r.:a shop drawings during ^ v G) �:i•_"•Gefr fr' i mcYFts of he plans a 1 oan,piiana: 6vith the regr«re sd 0 'zd; agars Approval of a speci►;c item shalt not int';ude aa; ravel of an a_>zmbty of which t,,z item is s component. Con - thjob r is lMna ion far. Dimensions to ba confismad and correlated at the e site Is.fneatian trio' pertains solely to the fabrication Processes or to the meows, methods, teMniques, sequences and procedures of conshuc. Gon: coordination of tt:a work of all oftr trades: and for performing all V✓ork to a safe and satisfactoiy manner. BATE: A 1 / / `i "f-�1— BY. 12/8/2017 Florida :Building Code Online k '" ► ogula,a BCIS Home Log In �. User Registration I Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff f BCIS Site Map E Unks Searcht �. F ttdd: uuulll►►► _ Product Approval ;USER: Public User - Product Aooroval Menu > Appllcatlon detall FL # FL5891-R5 Application Type Revision Code Version 2014 Application Status Approved Comments Archlved Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Therma-Tru Corporation 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rickw@rwbidgconsultants.com Rick Wright rickw@rwbldgconsultants.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan 1. King, P.E. K? Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Standard SSTD 12 TAS 202 Equivalence of Product Standards Certified By Sections from the Code year 1999 1994 hftps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDquw6mP[Zhp%2fndRcOWkL6ois4lbF6OvZnFg%3d 1/3 FL* Model, Number or.Name Description 5891.1 : a. "FiberClassic" 6'8 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswind Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.1.Ddf , Approved for use outside HVHZ: Yes Verified. By: Lyndon Schmidt, P.E. 43409 Impact. Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.1 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.1.Ddf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes Installation instructions. (For FiberClassic doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within. six months of Installation.) 5891.2 b. "SmoothStar" 6'8 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.2.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 i Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.2 for Design Pressure Ratings by FL5891 R5 AE Eva[ 5891.2.Ddf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes Installation instructions. (For SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of Installation.) 5891.3 c. "Classiccraft" 6'8 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 RS II Inst 5891.3.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.3 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.3.odf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes Installation Instructions. 5891.4 d. "FiberClassic" 8'0 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.4.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.4 for Design Pressure Ratings by FL5891 R5 AE Eva[ 5891,4.Ddf specific Mode[ and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.) 5891.5 e. "SmoothStar" 8'0 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of. Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.5.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third, Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.5 for Design Pressure Ratings by FL5891 R5 AE Eval 5891.5.Ddf specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For SmoothStar doors, this product approval requires the use of "J" part numbers for these doors, https://fforidabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwADquw6mPlZhp%2fndRcOWkL6ois4lbF6OvZnFg%3d 2/3 12/8/2017 Florida Building Code Online which have been stained or painted within six months of installation.) 5891.6 f. "ClassicCraft" 8'0 "Impact" Opaque Fiberglass Single Door (X) Inswing or Outswing Configuration Limits of Use Installation Instructions Approved for use In HVHZ: No FL5891 RS II Inst 5891.6.Qddf, Approved for use outside HVHZ: Yes Verified By: Lyndon Schmidt, P.E. 43409, Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.6 for Design Pressure Ratings by FL5891 RS AE Fval 5891.6.odf . specific Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®0M https://floridabuilding.org/prlpr_app_Otl.aspx?param=wGEVXQwtDquw6mPlZhpp/o2fndRcOWkL6ois4lbF6OvZnFgg/o3d 3/3