Loading...
HomeMy WebLinkAboutAPPROVED JAT 5V-2020Fi,qu1CA �pAlfTiEEM RF Business & Professional Regulation BCIS Home L09 In User P491stration Hot Topics E*3: �.. Product Approval USER: Public User Submit Surcharge Salts & FaCtS Publications Contact us UCiS Slte Map : Links : Search P 9RR YM Menu > Prodwa or Agpli lion ea > Ikati L's > Application Detail FL # Application Type FL17443-R2 Revision Code Version 2020 Application Status Pending FBC Approval Comments Archived Product Manufacturer ] A TAYLOR ROOFING Address/Phone/Emaii 302 Melton Drive FT PIERCE, FL 34982 (772) 466-4040 kylewhite228[ aol. corn Authorized Signature Kyle Taylor kylewhlte228@aoi.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Rooting Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Locke Bowden Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/23/2023 Validated By Diane Marotta, P.E. Certificate of Independence Validation Checklist - Hardcopy Received F1-17443 R2 CDI FL17443 R2 ] A 7aylOr FBC Code Evai R2port with ptall,-ssS-Pdf Referenced Standard and Year (of Standard) 2}an4ard Year TAS 125 2003 UL 1897 2012 ULS80 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Data Submitted 12/03/2020 Data Validated 12/13/20ZD Date Pending FBC Approval 01/06/2021 Sumea of ProduoM FL # Model, Number or Nam Description I7443.1 5 V Gimp 26GA 1/2" rib height over 15/32' APA plywood Limits of Use Approved for use In No Installation lnstrucNons FLIJ44a tsidH`WrHZ: Approved for use oubida HVH2: Yes 0.2 II ll A T FBC I m Impact Resistant: N/A Design Pressure: +N/fV-129.25 with SSr I ,pI Venfled By: Locke Bowden, P.E. 49704 Other:-129.25 ®6" o.c. -69.25 016" o.c. margin of safety Created by Independent Third Pa Evaluation Reports rtY: Yes 2:1 with 24" max. coverage Install per manufacturers detail. FLlI44i R2 ep FLll44 R Not for use in HVHZ. 1 T ggoort w M D�__ybr Far E y �)b S Rjf Created by ---Pendent Third Party: Yes 17"3.2 VICTORIAN CRIMP SHINGLE 26GA 1/2' RIB- PANELS LOCK INTO PREVIOUS PANELS; OVER CDX/APA 15/32" PLYWOOD Limits of Use Approved for use in HVHZ: No Installation Instructions 1 J4 FL1 Approved for use outside HVHZ: Yes 3 0.2 II R1J44 R A h I FB d P I R gtl yyi pip-« � P Design Resistant: N/A Design Pressure: + Verified By: Locke Bowden, P.E. 49704 in ty's05 Other:-IOSPSF margin of sa 9' fary Install Cleared! by Independent Third Pa Yes p manufacturers details and in compliance with CURRENT FBC len U Evaluation Reports FLll4g3 R not for use in HVHZ. Lll493 A Taylor CodeEval Report wI1M1 OMa'I¢_ Createtl by Intlepentlent ThiN Party: Yes sad, Louraad Us:: M1 duar ry Ine'nown, IL 9 Ph—�_ lM1eannon of Mersa is an Waco ampow,. Qawohf 20n tea'—:: Vim:'. am �a a ,coda law, seen amreea: a.a—u2mrd., rcrw do not want rou.rmaa a . d aa:�. raisem re.nnn,.. m. "��.r...._.. _._.._..... . — - - u—nnon, ,you araa Product APppval Aotapas: ®®®9R■ Credit Card Safe J A TAYLOR 302 Milton Dr. Drive Fort Pierce, FL 34962 Florida Product Approval #17443 Method: l-D (772) 466-4040 Compliant with CURRENT Florida Building Code Compliant with Florida Product Approval Rule # 61G20-3 Compliant Quality Assurance Program: PRI CONSTRUCTION MATERIALS TECHNOLOGY 5V Crimp thru fastened h" rib at each panel edge and 1 fastener in the center of the panel, 24" net coverage, 26GA ASTM A792, G-50, AZSS, .018, SOksi min. over min. 15/32" thick CDX plywood deck. Corrosion Resistant fastener 09-15 H WH with sealing washers, metal to wood connections with fastener length to penetrate 5/i6" thru substrate. Fasten along the crown of the rib In the center of panel and along the lap. First fastener to be within 3" of panel edges. Min. 8Dx2" annular ring shank nails spaced 6" O.C. re -roofing, with less than 19/32" plywood (min. 15/32"), this attachment is to be used in addition to existing attachment. Deck slope 2:12 or greater and shall be mrn fiant with FCurrent FBC Under -laymen See FBC Sec. 1507 **Design Pressure: Spacing: -59.25 PSF 16" O.C. •129.ZS PST 6'O.C. 26GA ASTM A792, G-50, AZSS, .018, 501csi Victorian Crimp Shingle over 15/32" CDX/APA Plywood attached to roof trusses. Corrosion Resistant Fastener#10 x 1" Zinc plated, MTW Pancake Head, installed at 2 per panel into lock seam. Panels applied with 12" exposure, adjacent shingles inserted into lock seam of previous shingle. Deck slope 2:12 or greater and shall be compliant with CURRENT Under-layment: See CURRENT FBC Under -lay ment Sec. 1507 Table **Design Pressure: -105 PSF **DES16N PRESSURHNCUIDEYA 0tIcE"MAR61N OF2A TEST REPORTS Reference Data: Hurricane Test Laboratory ITST-1527) PRI Construction Materials Technologies (TST-5878) #0224-0502-06 TAS 12S (UL 580.941) #FAE-023-02-01 I. UL 580-94 teststandards are equivalent to UL 580-06 test standards. UL 580-06/UL 1997-042 2. UL 1897-04 test standards are equivalent to UL 1897-12 test standards. Under-layment to be Compliance with Current Florida Building Code (FBC). see Charts Minimum slope to he compliant CURRENT Florida Building Code and per with Manufacturers installation reference. 2. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 3. Engineering analysis for "project specific approval by local authorities w/judsdiction is allowed by other registered engineers. 4. Fire Classification is not part of this acceptance. Shear diaphragm values are outside this report. S. Support framing in compliance w/CURRENT FLORIDA BUILDING CODE Chapter 22 Steel,Chapter 23 Wood and Chapter 16 Structural Loading. 6. This report does not imply warranty, installation, recommended product use outside ofthis report. Certificate of Independence: Locke Bowden, P.E. does not have, nor will acquire a Financial Interest in arty company manuEacturing or distributing products under this evaluation. Locke owden, P.E. is not owned, operated, or controlled by any company, `,,`� � il t� rrr ,'i/ manufacturer or distributing products under r orE 35 o.49704 tr a SPATEOF ;Ect_ 5 V Crimp Fastener- #9-15 corrosion resistant w/sealing washers t 24"coverage A.__ — Fastener: #9 x 15 corrosion resistant with sealing washers in Compliance with Current Florida Building Code, Section 1507 Perimeter fastening: 6"o.c. Main Field fastening12"0.c. Panel Width: 26" Panel Coverage: 24"maximum 26 GA Architectural Metal Roof panel VICTORIAN CRIMP LC MINIMUM 2 FASTENERS Fastener.#f0 x 1" AT LOCK SEAM Zinc Plated MTW Pancake Head I CUT 1/2 SHINGLE 1EATE STAGGERED ERN )RIAN CRIMP 'aLES I 9"EXPOSURE