HomeMy WebLinkAboutCompaction testUES Project No:
Workorder No:
Report Date:
3360.2000026.0000
224982-1
02/16/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:BALFOORT CONTRACTING, INC.UES Technician:Sean Hayes
21 N. River Road
Stuart, FL 34996
Date Tested:02/15/2021
Project:20-2436 BALFOORT CONTRACTING, INC. 2020-2
Martin, St. Lucie, Indian River, Brevard,and Okeechobee Counties, County, FL
Type of Test:
Area Tested:1540 NW Buttonbush Cir, Palm City -
Golf cart garage
Field:ASTM D-6938 Nuclear Gauge Method
Material:Native Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Center of slab 0-1 ft 110.7 11.5 108.9 10.6 98 Pass
2 North Corner of slab 0-1 ft 110.7 11.5 109.1 11.7 99 Pass
3 South Corner of slab 0-1 ft 110.7 11.5 108.9 10.8 98 Pass
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1