HomeMy WebLinkAbout20-1131 REED RESIDENCE STRUCTURAL PLANS JANUARY 2020 (Digitally signed &...PILING OVERVIEW SCALE: 3/16" = 1'-0" P1 P2 P3 P4 P9 P8P5P7 P12 P6 P10 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 P24 P11 CONSTRUCTION SET GENERAL NOTES FOUNDATION NOTES ALL SPLICES SHALL BE LAP SPLICES, SHALL BE A MINIMUM OF 48 BAR DIAMETERS, USING LARGER BAR DIAMETER WHEN SPLICING DIFFERENT SIZE BARS.REINFORCEMENT TERMINATIONS INTO TIE BEAMS AND FOUNDATIONS OR AS NOTED. CONCRETE REINFORMCEMENT CONCRETE REINFORCING BARS SHALL BE DEFORMED NEW BILLET STEEL CONFORMING TO ASTM A-615, GRADE 60, WITH MINIMUM YIELD STRENGTH = 60,000 psi. CONTRACTOR SHALL COORDINATE SLAB ELEVATIONS CHANGES AND ANY UNKNOWN FIELD CONDITIONS. ALL ELECTRICAL CONDUIT, PLUMBING, A/C DUCTS, AND OTHER MECHANICALLY REQUIRED INTERIOUR COMPONENT LOCATIONS AND INSTALLATION MUST BE COORDINATED WITH THE ARCHTECT PRIOR TO CONSTRUCTION OF THE FOUNDATION. ALL CONSTRUCTION PERFORMED IN ACCORDANCE WITH THESE PLANS MUST ALSO MEET OR EXCEED ALL APPLICABLE AND CURRENT BUILDING CODE REQUIREMNTS AND MUST BE PERFORMED IN ACCORDANCE WITH FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION CCCL PERMIT. CONCRETE NOTES STRUCTURAL NOTES A VAPOR BARRIER IS TO TO BE PLACED UNDER ALL BUILDING FOUNDATION BEAMS AND FLOOR SLABS IN ACCORDANCE WITH ASTM E 1993-98. TO BE INSTALLED PRIOR TO POURING CONCRETE FOR FOUNDATION. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 24 INCH LAP. PROVIDE CORNER BARS ALL CONCRETE MASONARY CONSTRUCTION SHALL CONFORM WITH ACI 530-88/ASCE 5-88. ALL CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 WITH TYPE M OR S MORTAR COMPLYING TO ASTM C-270. MASONRY UNITS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI ON THE NET AREA.THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION AND TO PROTECT AND MAINTAIN ALL THE CONSTRUCTION AND ITS CONTENTS. REFER TO THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT INDICATED. ANY DIMENSIONAL DISCREPANCY FOUND ON THE STRUCTURAL DRAWINGS SHALL BE FURTHER VERIFIED WITH ARCHITECT & ENGINEER. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE MANUFACTURE'S INSTRUCTIONS UNLESS INDICATED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. THE GENERAL CONTRACTOR SHALL AT ALL TIMES MAINTAIN AT THE JOB-SITE, A CURRENT APPROVED SET OF SHOP DRAWINGS. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR OPENINGS, SLEEVES, ETC. NOT SHOWN ON THE STRUCTURAL DRAWINGS. FOUNDATIONS SHALL BE PREPARED IN FULL CONFORMANCE WITH THE GEOTECHNICAL ENGINEERING REPORT. ALL RECESSES IN CONCRETE SLAB TO BE COORDINATED WITH ARCHITECT FOR DETAILS INCLUDING BUT NOT LIMITED TO: THRESHOLDS, STEPS, RECESSED SHOWER LOCATIONS, FLOORING FINISH MATERIALS, AND DRAIN LOCATIONS, ETC. THE FOLLOWING FREQUENCY OF TESTING SHALL BE REQUIRED BEFORE PLACING CONCRETE FOR FOOTINGS AND SLABS: CONTINUOUS FOOTING/GRADE BEAM SHALL BE TESTED EVERY 40 LINEAR FEET AT BEARING ELEVATION AND ONE FOOT BELOW BEARING. COLUMN FOOTINGS - 25% OF FOOTINGS SHALL BE TESTED AT BEARING AND ONE FOOT BELOW BEARING. BUILDING PAD SHALL BE TESTED EVERY 1000 SQUARE FEET OF FLOOR AT GRADE AND ONE FOOT BELOW GRADE. IN AREAS OF THE BUILDING PAD WHERE SOIL IS BEING CUT IT IS THE RESPONSIBILITY OF THE SITE CONTRACTOR TO DENSIFY THE TOP 12 INCHES OF EXISTING SOIL TO 95% OR MODIFIED PROCTOR AS RECOMMENDED IN THE SOILS REPORT FOR THIS PROJECT PREPARED BY KSM ENGINEERING, INC. DATED NOVEMBER 2009. THESE SOIL TESTS SHALL MEET OR EXCEED 95% MODIFIED PROCTOR (ASTM D1557 METHOD A) THE DESIGN AND CONSTRUCTION OF THE STRUCTURE AND/OR STRUCTURAL COMPONENTS DEPICTED ON THIS PLAN ARE FULLY UNDER THE JURISDICTION OF THE FLORIDA BUILDING CODE 2017. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL PLANS PRIOR TO COMMENCEMENT OF CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR COORDINATION OF CHANGES WITH THE ENGINEERING PLANS AND SPECIFICATIONS. CONTRACTOR SHALL COORDINATE SLAB ELEVATION, CHANGES, DEPRESSIONS, THRESHOLDS, PADS, ETC. AND ANY UNKOWN FIELD CONDITIONS. 1. MINIMUM CONCRETE COVER SHALL BE: FOOTINGS & PILES 3" BEAMS, SLABS, WALL 2" GROUTED MASONRY 2" STANDARD 90 DEGREE HOOK (STANDARD HOOK) SHALL TERMINATE WITH A 90 DEGREE BEND AND AN EXTENSION FROM BEND AT LEAST 12 BAR DIAMETERS. THIS SHALL BE USED AT ALL VERTICAL REINFORCEMENT TERMINATIONS INTO TIE BEAMS AND FOUNDATIONS OR AS NOTED. SECURE REINFORMCEMNT FROM DISPLACEMENT DURING PLACEMEMNT UTILIZING CHAIRS AND BOLSTERS. WELDED WIRE MESH SHALL CONFORM TO ASTM A-185. PROVIDE CHAIRS AND BOLSTERS TO INSURE THAT THE MESH IS EMBEDDED 1" FROM TOP OF SLAB. REINFORMCEMNT MAY BE BENT IN SHOP OR FIELD, PROVIDED THAT THE DIAMTERE OF BEND SHALL BE GREATER THAN 6 BAR DIAMETERS. REINFORCEMENT PARTIALLY EMBEDED IN CONCRETE SHALL NOT BE BENT. SHALLOW FOUNDATIONS SOIL TO BE STRIPPED, COMPACTED AND TESTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS ENGINEER AND PROJECT SPECIFICATIONS. CENTER ALL FOOTINGS UNDER THEIR RESPECTIVE COLUMNS OR WALLS UNLESS OTHERWISE SHOWN ON PLANS. MAXIMUM MISPLACEMENT OR ECCENTRICITY SHALL BE 2". TOLERANCE FOR MISLOCATION OF COLUMN DOWELS OR ANCHOR BOLTS TO BE PER ACI OR AISC STANDARDS. WHERE VERTICAL CONSTRUCTION JOINTS OCCUR IN CONTINUOUS FOOTINGS, PROVIDE A KEYWAY PER THE TYPICAL DETAIL. HORIZONTAL JOINTS IN FOOTINGS WILL NOT BE PERMITTED. CONTRACTOR TO NOTIFY ARCHITECT/ENGINEER IF SOIL CONDITIONS ARE UNCOVERED THAT PREVENT THE REQUIRED SOIL BEARING PRESSURE FROM BEING OBTAINED. COORDINATE PLUMBING LINES WITH FOOTING LOCATIONS FOR INTERFERENCE. INDIVIDUAL FOOTINGS SHOULD BE LOWERED WITH THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. CONTINUOUS WALL FOOTINGS SHOULD BE STEPPED AS DETAILED ON THE DRAWINGS. EXCAVATING UNDER OR NEAR IN-PLACE FOOTINGS/FOUNDATIONS WHICH DISTURBS THE COMPACTED SOIL BENEATH THE FOOTINGS/FOUNDATIONS WILL NOT BE PERMITTED. REINFORCING SHALL BE SUPPORTED ON PRECAST CONCRETE PADS. DOWELS FOR COLUMNS AND FILLED CELLS SHALL BE SECURED IN PLACE PRIOR TO POURING CONCRETE. USE TEMPLATES FOR SETTING COLUMN DOWELS AND ANCHOR BOLTS. 2. 9. 8. 7. 6. 5. 4. 3. 2. 1. 3. 4. 5. 6. ALL PILE VERTICAL REINFORCEMENT SHALL BE SHOP FABRICATED WITH CLEAN 90° BENDS INTO TRANSITION CAPS. HOOKS SHALL HAVE A MINIMUM LEG DIMENSION OF 15" AND SHALL BE TURNED ACROOS PILE INTO CAP CENTER (MAINTAIN A MINIMUM 3" CONCRETE COVER). ALL BEAM STEEL SPLICES SHALL OCCUR AT MIDSPAN FOR TOP STEEL AND OVER COLUMNS FOR BOTTOM STEEL. 3. 4. 5. 6. 7. 8. 9. 10. 2. 1. 1. 2. 7. 6. 5. 4. 3. ALL CONCRETE DESIGN AND PLACEMENT SHALL BE IN STRICT ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE," ACI 318-95. CONTACT ENGINEER 48 HOURS PRIOR TO POURING CONCRETE SO ARRANGEMENTS CAN BE MADE TO HAVE AN ENGINEER OR INSPECTOR PRESENT DURING THE POUR. PROVIDE (4) TEST CYLINDERS FOR EACH 50 C.Y. OF CONCRETE PLACED OR FRACTION THEREOF. STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS AND SHALL DEVELOP THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: SPREAD AND WALL FOOTINGS 3000 PSI COLUMNS AND WALLS 3000 PSI BEAMS AND SLABS 3000 PSI USE REGULAR WEIGHT CONCRETE. STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 AND HAVE THE FOLLOWING SLUMPS & AGGREGATE REQUIREMENTS: LOCATION SLUMP MAX. AGGREGATE FOOTINGS 4"±1" ASTM #57 COLUMNS 5"±1" ASTM #57 BEAMS AND SLABS 5"±1" ASTM #57 FILLED CELLS 8"±1" ASTM #8 PEAROCK TIE BMS & TIE COL'S 5"±1" ASTM #8 PEAROCK PILES 8"±1" ASTM #8 PEAROCK THE USE OF JITTERBUGS TO CONSOLIDATE CONCRETE WILL NOT BE PERMITTED. ALL PUMPED CONCRETE WITH #57 AGGREGATE IS TO CONTAIN A HIGH RANGE WATER REDUCING AGENT. MINIMUM SIZE OF DISCHARGE TO BE 4" I.D. A 2" I.D. DISCHARGE MAY BE USED WITH #8 AGGREGATE. USE PLASTICIZER ADMIXTURE IF NECESSARY TO INCREASE SLUMPS BEYOND THAT NOTED ABOVE. CHAMFER ALL EDGES OF EXPOSED CONCRETE 3/4" UNLESS NOTED OTHERWISE. ALL SLABS ON GRADE SHALL BE FIBER REINFORCED CONCRETE, UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM-A185. SLEEVE ALL PENETRATIONS THROUGH BEAMS AND SLABS INDIVIDUALLY. CORE DRILLING WILL NOT BE PERMITTED. SUBMIT LOCATION AND SIZE OF SLEEVES THROUGH BEAMS TO ENGINEER FOR REVIEW PRIOR TO CASTING CONCRETE. NO REINFORCING BARS SHALL BE CUT TO ACCOMMODATE THE INSTALLATION OF ANCHORS, EMBEDS OR OTHER ITEMS. AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS & STRIP FOOTINGS, PROVIDE CORNER BARS OF SAME SIZE AND QUANTITY UNLESS NOTED OTHERWISE AS HORIZONTAL STEEL. REFER TO TYPICAL DETAIL. ALL EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE PRIOR TO CONCRETE PLACEMENT. 3. 4. 5. 6. 7. 8. 9. 10. 2. 1. 11. 12. 13. CODE & DESIGN CRITERIA ASSUMPTIONS: A. THE BUILDING IS "ENCLOSED" AS DEFINED IN "FLORIDA BUILDING CODE 2017. B. WIND VELOCITY PRESSURES AND COEFFICIENTS USED ARE FOR MAIN WIND FORCE RESISTING SYSTEM; ALLOWABLE STRESS DESIGN, Kd = 0.85. C. ALL PRE-MANUFACTURED COMPONENTS, I.E. WINDOWS, DOORS, JAMBS, TRUSSES ETC. SHALL BE VERIFIED BY MANUFACTURER TO BE CAPABLE OF SUSTAINING DESIGN WIND FORCES. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS. D. ALL COMPONENTS AND CLADDING SUBJECT TO WIND LOADINGS: I.E. ROOF TILES, SOFFITS, ETC. SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS FOR ADEQUATELY RESISTING OR TRANSFERRING WIND LOADS TO THE MAIN WIND FORCE RESISTING SYSTEM. E. OWNER OR CONTRACTOR SHALL OBTAIN NECESSARY INSTALLATION SPECIFICATIONS AND INSPECTIONS REQUIRED TO COMPLY WITH MANUFACTURERS RECCOMMENDATIONS FOR INSTALLATION OF COMPONENTS AND CLADDING FOR HIGH WIND VELOCITY AREAS. 1. 2. 3. ALL STRUCTURAL PLANS SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE AND FLORIDA BUILDING CODE RESIDENTIAL 2017. BUILDING CLASSIFICATION ENCLOSED DESIGN WIND SPEED 170mph Vult IMPORTANCE FACTOR 1.04. 5.EXPOSURE CLASSIFICATION D INTERNAL PRESSURE COEF. ± 0.186. BUILDING HEIGHT 31.66' per FDEP Permit 7. MASONRY NOTES MASONRY CONSTRUCTION SHALL CONFORM TO ACI "BUILDING CODE EQUIREMENTS FOR MASONRY STRUCTURES" (ACI/ASCE 530-88) AND SPECIFICATIONS FOR MASONRY STRUCTURES" (ACI/ASCE 530.1-88) EXCEPT AS AMENDED BELOW. STRUCTURE HAS BEEN DESIGNED AS A BEARING WALL STRUCTURE. ALL MASONRY UNITS SHALL BE LAID PRIOR TO CONCRETE PLACEMENT OF COLUMNS, BEAMS AND SLABS FOR THE SAME STORY. USE TYPE "M" MORTAR WITH MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI FOR ABOVE GRADE APPLICATIONS AND TYPE "S" MORTAR WITH A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI FOR BELOW GRADE APPLICATIONS. MASONRY UNITS SHALL CONFORM TO ASTM C90 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2800 PSI ON NET SECTION, TO PROVIDE NET AREA COMPRESSIVE STRENGTH OF MASONRY (Fm') OF 2000 PSI. PROVIDE FILLED CELLS AS SHOWN ON PLANS. IN ADDITION, PROVIDE FILLED CELLS: A. AT ANCHORAGE OF CONNECTIONS OR BEARING OF BEAMS AND GIRDER TRUSSES. B. AT ALL CORNERS AND INTERSECTIONS C. (1) CELL ADJACENT TO OPENINGS FOR WALL SPANS LESSTHAN 10'. (2) CELLS ADJACENT TO OPENINGS FOR WALL SPANS GREATER THAN 10' D. AS SHOWN ON ARCHITECTURAL PLANS E. MAXIMUM 48" O.C. (UNLESS NOTED OTHERWISE) PROVIDE FULL MORTAR BEDDING AROUND ALL FILLED CELLS WITH VERTICAL REINFORCING. REINFORCING FOR FILLED CELLS SHALL CONFORM TO ASTM A615, GRADE 60, LAPPED 48 BAR DIAMETERS. ALL FILLED CELLS AND COLUMNS SHALL BE POURED AT LEAST TWO (2) HOURS PRIOR TO POURING BEAMS AND LINTELS. REINFORCE WALL WITH LADDER TYPE REINFORCEMENT ("DUR-O-WALL" OR EQUAL) IN BED JOINTS AT 16" O.C. MEASURED VERTICALLY. LAP SPLICE ALL HORIZONTAL WALL REINFORCING 6". PROVIDE PREFABRICATED "TEE" OR CORNER SECTIONS AT ALL INTERSECTING WALLS. REFER TO TYPICAL WALL SECTIONS FOR MAXIMUM CONSTRUCTION HEIGHT OF MASONRY WALLS. PROVIDE CLEAN-OUT HOLES AT BASE OF FILLED CELL WHEN THE CONCRETE POUR EXCEEDS 5 FEET IN HEIGHT. 1. 2. 10. 9. 8. 7. 6. 5. 4. 3.ALLOWABLE SOIL BEARING PRESSURE 2,500 PSF. VERIFY WITH GEOTECHNICAL ENGINEER REPORT PRIOR TO CONSTRUCTION. 8. HEADED STUD ANCHORS SHALL BE ASTM A108, GRADE S, 1010 THROUGH 1020 AS MANUFACTURED BY NELSON STUD OR APPROVED EQUIVALENT. STUD WELDING SHALL CONFORM TO AWS D1.1 "STRUCTURAL WELDING CODE." FOOTING SIZES SHOWN ARE FOR FOOTINGS CONSTRUCTED WITH SIDE FORMS. IF SOIL MATERIAL CAN HOLD A VERTICAL SHAPE, IT CAN BE USED AS AN EARTH FORM. ALL SLOUGHED MATERIAL SHALL BE REMOVED FROM EXCAVATION BEFORE AND DURING PLACEMENT OF CONCRETE. PLACEMENT OF CONDUIT AND PIPES IN CONCRETE SHALL CONFORM TO ACI 318, SECTION 6.3. 14. 15. 16. AT ALL PHASES OF CONSTRUCTION, IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CONFIRM THAT ALL PROPOSED CONSTRUCTION IS IN ACCORDANCE WITH THE MOST UP-TO-DATE CONSTRUCTION DRAWINGS AS APPROVED BY THE ARCHITECT AND ENGINEER OF RECORD. 10. SIESMIC ZONE 0 9. PILES SHALL BE CAST IN PLACE (AUGER) 16" DIA with 5,000 psi CONCRETE (SEE TYPICAL DETAIL). DEEP FOUNDATION ALL PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS ENGINEER AND PROVIDE THE FOLLOWING CAPACITIES: all piles @ 20'± below scour - 40 TONS COMPRESSION; 12 TONS TENSION REFER TO PILE SCHEDULE (sheet S-2) FOR MORE DETAILS. TOLERANCE FOR PILES IS 2" IN ANY DIRECTION UNLESS NOTED OTHERWISE. ALL PILES TO PENETRATE (-) 20.00 NAVD OR AS NOTED. REFER TO PILE SCHEDULE (sheet S-2) FOR MORE DETAILS. UNLESS OTHERWISE NOTED ON PLANS, CENTER ALL PILES/PILE CAPS UNDER RESPECTIVE COLUMNS. CAST IN PLACE (AUGER) TYPE PILES SHALL CONSIST OF CONCRETE PLACED AFTER BEING DRILLED BY A CONTINUOUS FLIGHT AUGER. 4. 3. 1. 2. THIS STRUCTURE IS DESIGNED IN ACCORDANCE WITH ASCE 24. THE PILE & COLUMN FOUNDATION AND THE STRUCTURE TO BE ATTACHED THERETO HAVE BEEN DESIGNED TO BE ANCHORED TO RESIST FLOTATION, COLLAPSE AND LATERAL MOVEMENT DUE TO THE EFFECTS OF WIND AND FLOOD LOADS ACTING SIMULTANEOUSLY ON ALL BUILDING COMPONENTS, IN ADDITION TO OTHER LOAD REQUIREMENTS AS DEFINED IN CHAPTER 16 OF THE FBC. 7. ALL FRANGIBLE (BREAKAWAY) WALLS HAVE BEEN DESIGNED IN ACCORDANCE WITH ASCE 24.11. THE WALLS AND PARTITIONS BELOW THE DESIGN FLOOD ELEVATION HAVE BEEN DESIGNED TO COLLAPSE FROM A WATER LOAD LESS THAN THAT WHICH WOULD OCCUR DURING THE BASE FLOOD. 11. THE ELEVATED PORTION OF THE BUILDING AND SUPPORTING FOUNDATION SYSTEM HAVE BEEN DESIGNED TO WITHSTAND THE EFFECTS OF WIND AND FLOOD LOADS ACTING SIMULTANEOUSLY ON STRUCTURAL AND NONSTRUCTURAL BUILDING COMPONENTS. 12. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. 20-1131 C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK AS NOTED 01/19/21 AUGER CAST PILING LAYOUT S-1PILING SCHEDULE & DETAIL DATE:DATE: AUGER-CAST PILE LAYOUT P1 P2 P3 P4 P9 P8P5P7 P12 P6 P10 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 P24 5'-4"8'-4"10'-4"9'-0"18'-0"10'-6"10'-6"10'-6"10'-6" P11 9'-0"7'-0"7'-0" 7'-0"7'-0" 5'-4"1'-4"8'-4"6'-8"9'-0"3'-9"27'-8"8'-0"13'-0"3'-6"15'-6"3'-9" 12'-8"1'-6"13'-0"13'-0"14'-0" SCALE: 1/4" = 1'-0" TYPICAL PILING @ ELEVATOR PIT - REFER TO DETAIL SHEET S-9 TYPICAL PILING @ PATIO w/ TRANSITION CAPTYPICAL PILING & TRANSITION CAP CRITICAL BEARING PILING 19.0 kips COMPRESSION LOAD 53.2kips MAX. LOAD (COMPRESSION)TYPICAL PILING & TRANSITION CAP 53.2kips MAX. LOAD (COMPRESSION) TYPICAL PILING & TRANSITION CAP CRITICAL BEARING PILE 57.2kips COMPRESSION LOAD TYPICAL PILING & TRANSITION CAP @ GARAGE PILING & TRANSITION CAP @ ENTRY CRITICAL BEARING PILE 57.2kips COMPRESSION LOAD CRITICAL BEARING PILE 28.8kips COMPRESSION LOAD TRANSITION CAP or GRADE BEAM REFER TO TRANSITION CAP DETAIL (sheet S-3) FOR REINF. REFER TO GRADE BEAM DETAILS sheet S-9 EL.=SEE SCHEDULE TOP OF TRANS. CAP 18"24"PILE/CAP/COLUMN DETAIL SCALE: NOT TO SCALE 16" dia. AUGER CAST PILE w/ (6) #6 BARS only (3) bars shown #3 STIRRUPS SPACED 4" O.C. @ TOP OF PILE THEN 10" O.C. FOR REMAINDER AS SHOWN POURED-IN-PLACE or PILATER BLOCK CONCRETE COLUMN - REFER TO PLANS FOR LOCATIONS - REFER TO COLUMN SCHEDULE FOR SPECIFICATIONS & REINFORCEMENT - TYPE "C-1" COLUMN ILLUSTRATED (6) #3 BARS TAPERED TO POINT & TIED TO PILE CAGE AS SHOWN WIRE TIES 3" MIN. PILE EMBEDMENT per FBC 1810.3.11 EL.=SEE SCHEDULE BOTTOM OF PILE CAGE4"12"12"12"CLEAN OUT 6" BELOW TOP OF PILE PRIOR TO CAP CONSTRUCTION 24"16"3"6"3"10"HOOK ALL PILE REINF TOWARDS CENTER OF TRANSITION CAP or GRADE BEAM - REFER TO DETAILS (sheet S-3) PILE SHALL BE DRILLED w/ A CONTINUOUS FLIGHT AUGER AND CAST w/ 5,000 PSI GROUT PILE CAPACITY IS RELATIVE TO PILE DEPTH BELOW THE SCOUR LINE. REFER TO DEEP FOUNDATION NOTES FOR DETAILS. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. CONSTRUCTION SET C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m PILING SCHEDULE INSTALLATION NOTE: TOP OF PILE STEEL SHALL NOT EXCEED 3" (0.25 feet) BELOW THE CAP ELEVATION 24.67'7.42 navd 24.25'7.00 navd 25.25'8.00 navd 6.00 navd -19.00 navd -19.00 navd4.25 navd 23.25' -19.00 navd6.25 navd -19.00 navd5.25 navd 16" AUGER-CASTP9 5.67 navd 16" AUGER-CASTP16 16" AUGER-CASTP12-P15 16" AUGER-CASTP17 16" AUGER-CAST 16" AUGER-CASTP21-22 P10-P11 16" AUGER-CASTP2-P6 16" AUGER-CASTP23-P24 16" AUGER-CASTP1 CAP eleationPILE lengthPILE DEPTHTOP OF PILETYPEDESIGNATION 20-1131 C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/4" = 1'-0" 01/19/21 AUGER CAST PILING LAYOUT S-2PILING SCHEDULE & DETAIL 24.08'6.83 navd-19.00 navd5.08 navd16" AUGER-CASTP7-P8 24.08'6.83 navd-19.00 navd5.08 navd 24.08'6.83 navd-19.00 navd5.08 navd 24.08'7.00 navd-19.00 navd5.08 navd 16" AUGER-CASTP18-20 24.25'7.00 navd-19.00 navd5.25 navd 24.08'6.83 navd-19.00 navd5.08 navd 25.25'8.00 navd-19.00 navd6.25 navd typ. saw cut typ. saw cut60"±60"± SCALE: 1/4" = 1'-0" TRANSITION CAP LAYOUTFRANGIBLE FOOTINGS & SLABS 12" THICKENED EDGEw/ (2) #5's cont.(typ. patio slab perimeter)ALL STEEL DISCONTINUOUSAT TRANSITION CAPS similar TOP OF CAP@ 7.0 NAVD TOP OF BEAM@ 6.0 NAVD(-2'-0" B.F.F.) TOP OF CAP @6.83 NAVD(1'-2" B.F.F.) SLOPE 2" F-6 MONOLITHIC FOOTER w/RECESS FOR GARAGE DOOR(typ.) - refer to details F-4 typical (3) sides F-2 4" thick FRANGIBLE SLAB (A/C equipment pad - refer to architecturals for locations) ELEVATION +0'-0" F.F. (8.0 NAVD) CONC. SPREAD FOOTING(typical at all masonry walls)refer to details sheet S-9ALL STEEL DISCONTINUOUSAT TRANSITION CAPS 4" THICK **FRANGIBLE** CONCRETE SLAB (MINIMUM 3000 PSI @ 28 DAYS) FIBERMESH REINFORCED - SAW CUT AS SHOWN OVER 6 MIL. VISQUEEN VAPOR BARRIER OVER CLEAN COMPACTED TERMITE TREATED FILL (COMPACTED TO 95% DENSITY) typical for all GROUND FLOOR slabs ELEVATION -1'-0" B.F.F. (7.0 NAVD) 5'-0"5'-4"2'-0"8'-0"21'-7" 6"4'-2"5'-8"3'-10"6" 6"6"6"6"6"~8"~13"flat slo p e flat slo p e 4'-0"5'-9"12'-8"ELEVATOR PITrefer to detailsTOP OF CAP @7.00 NAVD(1'-0" B.F.F.) F-3 ELEVATION -1'-2" B.F.F. (6.83 NAVD) ELEVATION -0'-7" B.F.F. (7.42 NAVD) CONC. SPREAD FOOTING(typical at all masonry walls)refer to details sheet S-9ALL STEEL DISCONTINUOUSAT TRANSITION CAPS 12" THICKENED EDGEw/ (2) #5's cont.(typ. patio slab perimeter) ELEVATION +0'-0" F.F. (8.0 NAVD) ELEVATION +0'-0" F.F. (8.0 NAVD) ELEVATION -1'-0" B.F.F. (7.0 NAVD) SLOPE 2" ELEVATION -1'-2" B.F.F. (6.83 NAVD)2'-0"11'-0"2'-0"11'-0"2'-0"28'-0"4" THICK CONCRETE SLAB (FRANGIBLE) 4" THICK CONCRETE SLAB (FRANGIBLE) ELEVATION -1'-0" B.F.F. (7.0 NAVD) ELEVATION -0'-6" B.F.F. (7.5 NAVD) ELEVATION -0'-6" B.F.F. (7.5 NAVD)ELEVATION -0'-6" B.F.F. (7.5 NAVD) F-3 F-3 F-5 F-1 F-1 F-3 F-3 F-3 F-3 5'-0"2'-0"2'-0" 5'-0"2'-0"5'-0"2'-0"2'-0" F-3 TOP OF CAP@ 8.0 NAVD 8'-4"2'-0"7'-0"2'-0"7'-0"2'-0"6'-4"2'-0" F-1 F-1 F-5 similar F-5 8'-6"2'-0"8'-6"2'-0"8'-6"2'-0"8'-6"2'-0" F-1 F-1F-1 F-1 F-7 2'-0"11'-0"ELEVATION -1'-0" B.F.F. (7.0 NAVD) 4" THICK CONCRETE SLAB (FRANGIBLE)2'-0"4'-2"F-5 similar typ. saw cut typ. saw cut60"±60"± TOP OF CAP@ 8.0 NAVD TOP OF CAP@ 6.83 NAVD 5'-8"6" 6" S-8 2 TYPICAL #6 IN AUGER CAST PILE exterior edge of grade beam interior edge of grade beam exterior edge of grade beam interior edge of grade beam PILE CAP see detail 16" AUGER CAST PILE (6) #6Ø IN AUGER CAST PILE #3 STIRRUPS MFR'd w/ 914 " INSIDE DIA. exterior edge of cap/footer interior edge top of pile edge of pile16" AUGER CAST PILE edge of pile16" 16" AUGER CAST PILE (6) #6Ø IN AUGER CAST PILE #3 STIRRUPS MFR'd w/ 914 " INSIDE DIA. 16" AUGER CAST PILE (6) #6Ø IN AUGER CAST PILE #3 STIRRUPS MFR'd w/ 914 " INSIDE DIA.3" typ.PILE REINFORCEMENT DETAILS SCALE: NOT TO SCALE TYPICAL PILE @ GRADE BEAM TYPICAL PILE @ TRANSITION CAP (w/ adjacent continuous footing) TYPICAL PILE @ GRADE BEAM (CORNER) TYPICAL PILE PROFILE CONTINUOUS FOOTER @ EXTERIOR PERIMETER w/ (2) #5's cont. (TYP.) DISCONTINUE STEEL for FRANGIBLE FOOTINGS refer to plans for locations bottom of transition cap TRANSITION CAP DETAILS SCALE: NOT TO SCALE (3) #3 STIRRUPS @ 9" O.C. (7) #6x18" @ 9" O.C. AS SHOWN 18"18"R 1 " t y p . 2" #6x18" EACH SIDE AS SHOWN PROVIDE A MINIMUM 3" CONCRETE COVER FOR ALL REINFORCING STEEL. ALL TRANSITION CAPS ARE CENTERED OVER CORRESPONDING AUGER PILE. SCALE: NOT TO SCALE THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. FRANGIBLE SLAB DETAIL SCALE: not to scale 60"60"112" min.4"3 16 " max.nominalclean compacted fill SAW-CUT 4" conc. SLAB4" conc. SLAB induced crack SAW-CUT SAW-CUT4" THICK CONCRETE SLAB (MIN. 3000 PSI @ 28 DAYS) FIBERMESH REINFORCED - SAW CUT AS SHOWN - OVER 6 MIL. VISQUEEN VAPOR BARRIER OVER CLEAN COMPACTED TERMITE TREATED FILL (COMPACTED TO 95% DENSITY) typical for all GROUND FLOOR slabs CONSTRUCTION SET ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS ALL CONCRETE SLABS BELOW THE LOWEST HORIZONTAL SUPPORTING MEMBER ELEVATION (16.41 N.A.V.D.) SHALL BE FRANGILBE DESIGN. ALL CONCRETE SLABS BELOW THE LOWEST ALLOWED HORIZONTAL SUPPORTING MEMBER ELEVATION (16.41 N.A.V.D.) SHALL BE FRANGILBE DESIGN. TYPICAL SLAB TRANSITION SCALE: 3/4" = 1'-0" 8"8"4" STEP VAPOR BARRIER clean termite treated granular fill 8"x8" THICKENED EDGE *FRANGIBLE* 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations 20-1131 C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/4" = 1'-0" 01/19/21 AUGER CAST PILING LAYOUT S-3PILING SCHEDULE & DETAIL SIMPSON HETA20 AT EACH TRUSS (typical) BEAM & COLUMN LAYOUT SCALE: 1/4" = 1'-0" 1st FLOOR FRAMING PLAN ALL ROOF TRUSSES SHALL BE ANCHORED with SIMPSON HETA20 EMBEDDED TRUSS STRAPS, UNLESS NOTED OTHERWISE 6" ALL MASONRY CONSTRUCTION ORIGINATING BELOW THE LOWEST ALLOWED HORIZONTAL SUPPORTING MEMBER @ 15.50' N.A.V.D. (FIRST FLOOR)SHALL BE FRANGIBLE CONSTRUCTION, UNLESS NOTED OTHERWISE. REFER TO SHEET S-10 FOR FRANGIBLE WALL CONSTRUCTION DETAILS. ALL WALLS DENOTED "MASONRY SHEARWALL" (ILLUSTRATED AS ) ARE NOT FRANGIBLE AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE METHODS PRESCRIBED IN THE "BUILDING SECTION" ON THE DETAILS SHEET S-8. ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS CTB-1 #4's @ 12" o.c. SLOPE 1" CANTILEVER 4'-4" 677# B DROP BEAM FORM AS NECESSARY FOR GARAGE DOOR or USE PRECAST LINTEL COMPOSITE BEAM - REFER TO SECTION FOR DETAILS C-1 13'-4"15'-8"6'-0"6'-0"8'-0"12'-0"14'-4"F01GZ H J 5 ZCJ1 ZCJ3 ZCJ5 ZEJ5 ZCJ1ZCJ3ZCJ5ZEJ5 2'-0"5'-4"2'-0"8'-0"2'-0"2'-0" CTB-1 CTB-1 CTB-1 CTB-1 CTB-4 CTB-1a8'-8"C-1 C-1 C-2 C-2 C-1 CTB-1 13'-4"CTB-1CTB-1 CTB-1 C-1 CTB-1 C-1 CTB-1 C-1 CTB-1 C-2 C-1 C-4 C-1 3'-6"CTB-1C-3 C-3 18'-8"CTB-29'-2"4'-6"C-4 C-5 5'-9" CTB-1 HYBRID CONCRETE-STEEL JOIST FLOOR SYSTEM by others - REFER TO SHOP DRAWINGS FOR DETAILS S-7 1 MASONRY SHEARWALLtypical @ elevator shaft 13'-8"CTB-5C-4 CTB-5C-4 CTB-1 CTB-4 ELEVATION SLOPE 1" ELEVATION ELEVATION ELEVATION 11'-4" A.F.F. OPEN TO BELOW POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB ELEVATION 10'-10" A.F.F.ELEVATION 10'-9" A.F.F.28'-0"6" 11'-4" A.F.F. 11'-4" A.F.F. 11'-4" A.F.F. ELEVATION 10'-10" A.F.F.ELEVATION 10'-9" A.F.F. #4's @ 12" o.c. POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB #5's @ 8" o.c.C ↓678# ↑ 724# 5'-9" S-8 3 S-8 1 CANTILEVER 4'-4" LHSM MAIN BEAM SHALL BE CONCRETE (8"x24") TIE BEAM w/ (2) #5"s TOP & BOTTOM U.N.O. TOP OF LHSM MAIN BEAM SHALL BE 11'-4" A.F.F. 4'-8" 4'-8" ALL NON LOAD-BEARING MASONRY WALLS SHALL BE CAPPED WITH A SINGLE COURSE GROUT FILLED BOND BEAM (8"x8") w/ (1) #5 CONTINUOUS #4's @ 12" o.c.#5's @ 8" o.c.#4's @ 12" o.c.#5's @ 8" o.c. POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB 6'-0"8'-0" 8'-0"10'-6"10'-6"11'-6"11'-6"6'-0" 11'-4"9'-1"8'-11"9'-5" 11'-7"5'-5" 8'-9"6'-0"14'-0"14'-0"13'-10"14'-0"14'-0"CTB-3CTB-3 CTB-6CTB-7 CTB-1a CTB-1a CTB-1aCTB-1a CTB-1a CTB-1CTB-1803# B S-8 2 312"x312x38" TUBE STEEL COLIMN 28'-0"CTB-1aCTB-1aCONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO CONSTRUCTION CONTRACTOR TO COORDINATE CLEARANCES AT STAIRWAYS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION. REMARKS 16" 24" SEE PLAN FOR ORIENTATION H 8"C2 C3 8"BC-1 HB #3 @ 12" O.C. (8) #5 C-4BH C-2 16" H PLAN SIZE CONCRETE COLUMN SCHEDULE C1 B 8" MARK #3 @ 12" O.C. TIES REINFORCEMENT VERTICAL (4) #5 12"C4 12"(4) #5 #3 @ 12" O.C. C-3 C5 (6) #5 H BTYPICAL FORM-POURED COLUMN TYPICAL CORNER FORM-POURED COLUMN FORM-POURED COLUMN - GARAGE CORNERS C-6 12" sq. PILASTER BLOCK COLUMN - see note below C-6 MAY BE USED IN PLACE OF C-4 N/A 18"8"(6) #5 #3 @ 12" O.C.FORM-POURED COLUMN - PATIO CENTER C-5 C6 12"12"(6) #5 #3 @ 12" O.C.OPTIONAL 12"x12" COLUMN - FORM-POUR H BHB REMARKS 12" CTB-2 CTB-3 #3 @ 12" O.C. #3 @ 12" O.C. 8" W PLAN SIZE FIRST FLOOR CONCRETE TIE BEAM SCHEDULE CTB-1 D 24" MARK #3 @ 12" O.C. STIRRUPS REINFORCEMENT TOP (2) #5 12" CTB-4 #3 @ 12" O.C. CTB-1DW M.BOT. TOP of BEAM (3) #5 (3) #5 CTB-2 n/a (2) #5 TYPICAL 1st FLOOR BEAM exterior 8"21" (3) #5 (3) #5n/a CTB-3 CTB-4DW CTB-5 12"CTB-5 17"#3 @ 12" O.C.12" BEAM - REAR PATIO EXTERIOR MIN. 16"CTB-6 24"#3 @ 10" O.C.16" BEAM - EXTERIOR WALL BEARING(3) #5 (3) #5n/a 12"CTB-7 #3 @ 12" O.C.(3) #5 (3) #5n/a varies CTB-6DW CTB-7DW 12"CTB-5a #3 @ 12" O.C. +11'-1" varies STEP BEAM - Refer to details this sheet (3) #5 (3) #5n/a (3) #5 (3) #5n/a (2) #5 (2) #5 n/a 12" BEAM - PATIO BEAM per ARCHITECT 24" 23" 12" BEAM - ROOF BEARING #3 @ 12" O.C.8"24"n/a 8" BEAM OVER GARAGE DOOR(2) #5 (2) #5 +11'-4" varies 12" BEAM - BOTTOM @ +9'-4" A.F.F.sloped DW TOP SLOPED 1" (patio) DEPTH VARIES FROM 18" MAX. to 17" MIN. +11'-4" +11'-4" +10'-9"DW DW +10'-9" +11'-4" CTB-1a n/a TYPICAL 1st FLOOR BEAM interior CTB-1a SIMILAR CTB-5a SIMILAR INCREASE STIRRUPS TO 6"o.c. FOR 36" FROM ENDS & ADD (2) #5x36" BARS AS SHOWN (2) #5x36" 6"o.c. @ ENDS @10"o.c. w/ EACH END RECESS BEAM FOR S.G.D.AS SHOWN ON PLANS (right) CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONSTRUCTION SET FLOOR FRAMING PLAN COLUMN & BEAM SCHD. 20-1131 C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/4" = 1'-0" 01/19/21 S-4 CTB-1a +11'-1" A.F.F. +10'-9" A.F.F. bottom steel top steel CANTILEVER BEAM DETAIL SCALE: not to scale 21" 16" 6" INSURE A MINIMUM TWO-INCH (2") CONCRETE COVER (PROTECTION) FOR ALL BEAM REINFORCEMENT STEEL. CT B - 1 a CT B - 2 4'-8"4'-0" 24" CANTILEVER +10'-10" A.F.F. 3" SLOPE 1" 5" CTB-6@ recess RECESS BEAM FOR SLIDING GLASS DOOR FRAME - REFER TO ARCHITECUTRALS FOR REQUIREMENTS - ADJUST STEEL PER DETAIL AT LEFT... RECESS per ARCHITECT ADJUST STEEL REINF. CTB-7 +11'-1" A.F.F.+10'-9" A.F.F.bottom steel top steel PATIO STEP BEAM DETAIL SCALE: not to scale 21" 17" 6" INSURE A MINIMUM TWO-INCH (2") CONCRETE COVER (PROTECTION) FOR ALL BEAM REINFORCEMENT STEEL.CTB-1aCTB-65'-4"7'-4" 24" BALCONY +10'-10" A.F.F. 3" SLOPE 1"CTB-517" 16" BEAM CTB-7 +11'-4" A.F.F.bottom steel top steel+11'-1" A.F.F. 2nd FLOOR FRAMING PLANLOWER ROOF FRAMING PLAN C-4 SCALE: 1/4" = 1'-0"E01ZHJ4ZCJ1 ZCJ1Z H J 4 ZCJ1 ZCJ1ZCJ3 ZEJ4 ZCJ3 ZEJ4 S-7 1 C-4 #4's @ 12" o.c.CTB-9CTB-8 CTB-811'-7"5'-5" CTB-8 9'-2"OPEN TO BELOW HYBRID CONCRETE-STEEL JOIST FLOOR SYSTEM by others - REFER TO SHOP DRAWINGS FOR DETAILSSIMPSON MTS12 AT EACH TRUSS (typical) 915# D LOWER ROOF FRAMING REFER TO SHEET S-4 FOR DEATILS 312"x312x38" TUBE STEEL COLIMN C-4 13'-8"INTERMEDIATE BEAM SHALL BE CONCRETE (8"x24") TIE BEAM w/ (2) #5"s TOP & BOTTOM U.N.O. TOP OF INTERMEDIATE BEAM SHALL BE 23'-4" A.F.F. S-8 3 S-8 1 GIRDER TRUSSCTB-8 "INTERMEDIATE BEAM" 45'-4" 3'-4"3'-2"19'-0"3'-2"16'-8" CONTRACTOR SHALL VERIFY ALL WINDOW & DOOR OPENING DIMENSIONS WITH THE ARCHITECTURAL PLANS AND THE MANUFACTURER SHOP DRAWINGS PRIOR EXTERIOR MASONRY WALL CONSTRUCTION 8'-8"19'-4"24'-0"CTB-8 "INTERMEDIATE BEAM" 50'-8" 19'-5"1'-8"4'-8"1'-8"9'-9"9'-3"4'-4" 7'-4" 7'-4" ELEVATION +11'-4" A.F.F. ELEVATION +11'-4" A.F.F. ELEVATION +11'-4" A.F.F. ELEVATION +11'-4" A.F.F.8'-0"3'-2"2'-4"2'-6"5'-4"1'-0"2'-4"4'-6"3'-0"4'-4"2'-4"1'-2"915# D 6'-0"8'-0"2'-0"20'-0"CTB-8ELEVATION +11'-0" A.F.F. POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB ELEVATION +10'-10" A.F.F. POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB FLUSH DOUBLE (2) 2x12 P.T. BEAM (w/ 1/2" PLYWOOD SPACER) TYPICAL @ BALCONY ROOF SIMPSON MBHU3.56-SS TYPICAL TWO (2) LOCATIONS CONSTRUCT FILLED CELL COLUMN @ CONNECTOR LOCATION 6x6 P.T. POST - TWO LOCATIONS SIMPSON CBS66 at BASE (4) 1/2" SS BOLTS at CAP 4" SHOWER RECESS TRANSITION BEAM ELEVATION +11'-0" A.F.F. POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB POURED-IN-PLACE 6" THICK (nominal) 3000psi CONCRETE STRUCTURAL SLAB 3'-2"5'-9"8'-0"STEP BEAM 7" 6" 6"6"SIMPSON HETA20 AT EACH TRUSS (typical)CTB-12CTB-8CTB-10 CTB-11 CTB-12aCTB-13CTB-14 CTB-15 CTB-8 SLOPE 1" #5's @ 12" o.c.#4's @ 12" o.c.#5's @ 12" o.c.#4's @ 12" o.c.S-8 2 E02GZCJ3ZCJ32'-3" 2'-0"4'-0" 1077# F 1077# F G ↓1444# ↑ 1843# G ↓2629# ↑ 2594# SECURE VALLEY SET TRUSSES TO COMMONS w/ SIMPSON VTCR @ 48" O.C. (min. 2 per truss) CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO CONSTRUCTION CONTRACTOR TO COORDINATE CLEARANCES AT STAIRWAYS WITH ARCHITECTURAL DRAWINGS PRIOR TO CONSTRUCTION.DW CTB-10 REMARKS CTB-10 #3 @ 12" O.C. W PLAN SIZE SECOND FLOOR CONCRETE TIE BEAM SCHEDULE D MARK STIRRUPS REINFORCEMENT TOP 8"#3 @ 12" O.C. M.BOT. TOP of BEAM 8" n/a 16" CTB-12 CTB-13 CTB-14 #3 @ 12" O.C.8" BEAM - PATIO SLABsloped8" 12"#3 @ 12" O.C.12" BEAM - REAR PATIO EXTERIOR BEAM DW DW CTB-11 BEAM n/a n/a CTB-11 8"CTB-9 #3 @ 12" O.C.(2) #5 +23'-1"n/a (2) #5n/a 8"CTB-8 #3 @ 12" O.C.(2) #5 +23'-4"n/a (2) #5n/a 8" BEAM - TYPICAL 2nd FLOOR INTERIOR DW CTB-8DW DW CTB-9DW DW CTB-12DW DW CTB-13 DW CTB-14 +22'-10" 12" BEAM - TYPICAL 2nd FLOOR EXTERIOR 16" BEAM - RECESS FOR SLIDING GLASS DOOR+13'-0" (3) #5 (3) #5 #3 @ 12" O.C.(3) #5 (3) #5 24" varies 36" 24" 48" 21" 24" (2) #5 (2) #5 8" BEAM - TYPICAL 2nd FLOOR EXTERIOR W CTB-15DTRANSITION BEAM @ REAR PATIO (3) #5 CTB-12a 12"#3 @ 12" O.C.+23'-4"(3) #5 (3) #542" (3) #5 12" BEAM - SHOWER RECESS EXTERIOR BEAM n/a 8"CTB-15 #3 @ 12" O.C.(2) #5 +23'-4"(2) #5n/a12"8" BEAM - SHOWER RECESS TRANSITION (2) #5 (2) #5 (2) #5 (2) #5 +23'-4" +23'-4" CTB-12a SIMILAR (3) #5 JOIST LEDGERED PERPENDICULAR TO TIE BEAM L 4"X6"X3/8" W/ 1/4" STIFFENER W/ (2)3/4"∅X7" LONG WEDGE ANCHOR BOLTS. 5" MIN. EDGE DIST. LOCATED AT JOIST SHOE, 4'-0" O.C. (TYP.) COMPOSITE STEEL JOIST PRE-CAST CONCRETE SLAB AERIAL FLOOR SYSTEM 3" SE E P L A N 2"3/16" CONCRETE BEAM (BY OTHERS)6"4" PLATE 8"X12"X 3 4" W/(4)3/4"∅X5-1/4" LONG HEADED STUDS 8"11 2"SLAB LEDGERED TO UPTURNED BEAM (2) 1/2"∅ X 3" WEDGE ANCHORS NOTE: BOLTS AT HORIZ. LEG OF ANGLE IS ONLY REQUIRED IF THE EMBED IN SLAB IS MISSING AT TOP LEG PROVIDE CH-100 EMBED PLATE TO BE PLACED ON THE SIDE OF TIE BEAM 3/16"2" COMPOSITE STEEL BAR JOIST PRE-CAST CONCRETE SLAB AERIAL FLOOR SYSTEM CH-300 INSERT @ 4'-0" O.C. CONCRETE BEAM (BY OTHERS)3"SE E P L A N GROUT STEEL ROUND BAR5"x APC-x x APC-x CONNECTION CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONSTRUCTION SET 20-1131 C:\Users\PHILIP~1\AppData\Local\Temp\BricsCAD\bp_0\REED STRUCTURAL_1.0.dwg by PhilipPepe on Jan 20, 2021 - 11:51amMARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/4" = 1'-0" 01/19/21 SECOND FLOOR FRAMING PLAN S-5BEAM SCHEDULE & DETAILS CTB-12 CTB-12a +23'-4" A.F.F. +22'-9" A.F.F. bottom steel top steel 7" STEP BEAM TRANSITION DETAIL SCALE: not to scale middle steel 42" 35" 7" 8'-8" INSURE A MINIMUM TWO-INCH (2") CONCRETE COVER (PROTECTION) FOR ALL BEAM REINFORCEMENT STEEL. CT B - 1 1 CT B - 1 0 by others (REFER TO SHOP DRAWINGS) SCALE: not to scale PRECAST FLOOR SYSTEM CONNECTION DETAILS CTB-13@ recess RECESS BEAM FOR SLIDING GLASS DOOR FRAME - REFER TO ARCHITECUTRALS FOR REQUIREMENTS - ADJUST STEEL PER DETAIL AT LEFT... RECESS per ARCHITECT ADJUST STEEL REINF. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO CONSTRUCTION top steel bottom steel SECURE VALLEY SET TRUSSES TO COMMONS w/ SIMPSON VTCR @ 48" O.C. (min. 2 per truss) SCALE: 1/4" = 1'-0" MAIN ROOF FRAMING PLAN ALL MASONRY WALL TOP OF BEAM (main roof bearing) @ +23'-0" A.F.F unless noted otherwise ALL MAIN ROOF BEARING SHALL BE ON 8"x16" CONCRETE TIE BEAM, UNLESS NOTED OTHERWISE refer to sections and details GIRDER TRUSSZMG7 Z H J 7 ZCJ1 ZCJ3 ZCJ5 ZCJ1ZCJ3ZCJ5ZEJ7 D03GD02D01Z H J 7 ZCJ1 ZCJ3 ZCJ5 ZCJ1ZCJ3ZCJ5ZEJ7 ZHJ7ZCJ1 ZCJ3 ZCJ5 ZCJ1ZCJ3ZCJ5ZEJ7 ZEJ7S ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZHJ7ZCJ1 ZCJ3 ZCJ5ZCJ1ZCJ3ZCJ5 ZEJ7 Z H J 7 ZCJ1 ZCJ3 ZCJ5 ZCJ1ZCJ3ZCJ5ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZEJ7 MV2 MV4 S-7 1 2349# E LOWER ROOF FRAMING REFER TO SHEET S-4 FOR DEATILS S-8 3 S-8 1 L1 L2 L3 L4 L5GIRDER TRUSS5'-5"4'-6"4'-6"4'-6"3'-8"5'-10"3'-8"4'-6"3'-8"3'-8"7'-3"20'-0"13'-4"5'-5"L3 L3 L1 L6L7L7 L7 L7 L8 B03GB02B01A03A02A06GA05A04A03A02A01A01A01A01A01A01A01A01A01A01A01A01A01PRE ENGINEERED WOOD TRUSSES @ 24" o.c. SIMPSON HETA20 AT EACH TRUSS (typical) GIRDER TRUSS 2310# E 677# B 677# B 2310# E 1408# B 1556# B 677# B 600# B 1380# B 677# B 677# B GIRDER TRUSS5'-0" 5'-0" 5'-0" 2'-0"2'-0"2'-0"2'-0"52'-8"28'-0"2'-0"2'-0"2'-0"2'-0"58'-0" 2'-0"2'-0"5'-4"8'-0"20'-0"S-8 2 QUANITY OF #5 REBAR AT TOP QUANITY OF #5 REBAR AT BOTTOM OF LINTEL CAVITY NOMINAL HEIGHT NOMINAL WIDTH F=FILLED w/ GROUT U=UNFILLED 8F16-1B/1T NOTE: USE CASTCRETE NOTE: ALL GABLES & JACKS = <250PLF NOTE: R=RECESS LINTEL DEPTHS MAY BE INCREASED, BUT NOT REDUCED SCHEDULE TO BE FILLED IN BY ENGINEER REMARKS APPLIED LOADS ON ALL PRECAST LINTELS HAVE BEEN REVIEWED TO INSURE THEY ARE WITHIN ALLOWABLE LIMITS. APPLIED UPLIFT LOAD L1 L2 LINTEL NO. LENGTH UPPER BEAM CONCRETE LINTEL SCHEDULE APPLIED GRAVITY LOAD SAFE GRAVITY LOAD SAFE UPLIFT LOAD COMPOSITE BEAM L3 L4 L5 L6 L7 (TYP. VARIES) 8F248F20 8F328F28 8" NOMINAL WIDTH OF LINTEL CAVITY ACTUAL BOTTOM REINFORCING PROVIDED IN LINTEL #5 REBAR AT BOTTOM MIN.(1)#5∅ REBAR 1-1/2" CLEAR REQ'D AT TOP W/ 8F128F16 8U88F8 GROUT C.M.U. 7-5/8"16" NOMINAL HEIGHT15-5/8" ACTUAL13.ADDITIONAL LATERAL LOAD CAPACITY CAN BE OBTAINED BY THE DESIGNER BY PROVIDING ADDITIONAL REINFORCED CONCRETE MASONRY ABOVE THE LINTEL. SEE DETAIL AT RIGHT. 12.ALL RACEWAYS AND PIPES PLACED IN OR THROUGH ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF THREE DIAMETERS OF THE LARGEST CONDUIT OR PIPE FROM ANY OTHER SERVICE. 11.THE EXTERIOR SURFACE OF LINTELS INSTALLED IN EXTERIOR CONCRETE MASONRY WALLS SHALL HAVE A COATING OF STUCCO APPLIED IN ACCORDANCE WITH ASTM C-296 OR OTHER APPROVED COATING.. 10.PRODUCT APPROVALS: MIAMI-DADE COUNTY, FLORIDA NOS. 03-0606.05 & 03-0605.04. FLORIDA CERTIFICATE OF PRODUCT APPROVAL NUMBER FL158. 9.SAFE LOAD RATING BASED ON RATIONAL DESIGN ANALYSIS PER ACI 318 AND ACI 530. 8. 6. 5. 4. 3. 2. 1.PROVIDE FULL MORTOR BED AND HEAD JOINTS. SHORE FILLED LINTELS AS REQUIRED. INSTALLATION OF ALL LINTELS MUST COMPLY WITH THE ARCHITECTURAL and/or STRUCTURAL DOCUMENTS. U-LINTELS ARE MANUFACTURED WITH 5 1/2" LONG NOTCHES AT THE ENDS TO ACCOMODATE VERTICAL CELL REINFORCING AND GROUTING. REFERENCE THE CAST-CRETE LOAD DEFLECTION GRAPH ROCHURE FOR LINTEL DEFLECTION INFORMATION. BOTTOM FIELD ADDED REBAR TO BE LOCATED AT THE BOTTOM OF THE LINTEL CAVITY. CAST-IN-PLACE CONCRETE MAY BE PROVIDED IN COMPOSITE LINTEL IN LIEU OF CONCRETE MASONRY UNITS. PRECAST LINTEL NOTES 7. 7/32" DIAMETER WIRE STIRRUPS ARE WELDED TO THE BOTTOM STEEL FOR MECHANICAL ANCHORAGE Applied vertical load Safe vertical load Safe horizontal load Applied horizontal load+ 1.0 8F16-1B/1T L8 3'-6" 5'-4" 7'-6" 21'-4" 5'-10" 5365 2290 6113 4569 2661 1634 598 369 250 350 850 1000 250 350 no load no load 700 950 no load no load 4'-6"6113 2724200 300 6756 2093 13'-4"1075 606 8F16-1B/1T 8F16-1B/1T 8F16-1B/1T 8F16-1B/2T 8F16-1B/1T 8F16-1B/1T 8F16-1B/1T 4'-6"6113 2724 850 1000 CONDITION #1: STRAP IS O" TO 3/8" AWAY FROM REPAIR: NO REPAIR NECESSARY. CONDITION #2: STRAP IS 3/8" TO 1-1/2" AWAY FROM EDGE OF TRUSS. REPAIR: PLACE MAXIMUM 2x4 AND MAY BE USED ON EITHER SIDE OF WALL. DETAIL AND NAIL 7-10d. CONDITION #3: STRAP IS MORE THAN 1-1/2" AWAY FROM EDGE OF TRUSS. REPAIR: PER DETAIL SHOWN USING USP RT18112 ANCHORED TO WALL WITH (3) 1/4"x2-1/4" (MIN.) TAP-CONS AND NAILED TO TRUSS WITH 7-10d. MAXIMUM 1200 LBS. UPLIFT. APPLIES TO MULTIPLES AND CONSECUTIVE TRUSSES, BLOCK BETWEEN TRUSS AND STRAP. BEND PER EVENLY AT LEAST 2" FROM TOP (3) 1/4" X 2-1/4" TAPCONS SPACED RT18112 EDGE OF TRUSS. BLOCK TRUSS STRAP STRAP MISALIGNMENT REPAIR SCALE: not to scale NOTE: USP-RT18112 MAY BE SUBSTITUTED WITH SIMPSON HTSM16 AT ANY LOCATION CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONSTRUCTION SET C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m 10d x 1 1 2 " NAILS TYPE MAIN ROOF CONNECTOR SPECIFICATION CHART ALL WOOD TO CONC. CONNECTIONS, UNLESS NOTED BELOW. CONNECTOR MARK & DESCRIPTION ALL WOOD TO WOOD CONNECTIONS, UNLESS NOTED BELOW. REACTIONS HETA20 SIMPSON MANUFACTURER CONNECTOR NUMBER MTS12 SIMPSON 9 FASTENERS REQUIRED per MFR's SPECIFICATIONS 14 <xxxx A <xxxx B 10d x 1 1 2 " NAILS SINGLE PLY GIRDER TO CONCRETE TIE BEAM <xxxx C QUANTITY <xxxx D HU28-SS 2-PLY GIRDER TRUSS TO CONCRETE BEAM <xxxx E SIMPSON 4 (CONC) 1 4 " x 1 3 4 " TAPCONS SINGLE PLY HIP GIRDER TO (2) 2x12 HEADER ALLOWABLE LOAD TRUSS LABEL(s) UPLIFT↑ GRAVITY↓ ↑1000 UPLIFT↑GRAVITY↓ ↑ 1562 max. ↑ 950 max. ↑ 915 ↑1810 <xxxx F <xxxx G H16 SIMPSON ↑1470 ↑ 1077 max. GIRDER TRUSS TO (2) 2x12 HEADER F01G A06G B03G MBHU3.56 (9 1 4 " depth) SIMPSON (2) 2x12 HEADER TO CONCRETE BEAM <xxxx H 2 (truss) 10 (header) ↓ 2400 ↑ 760 2 (truss)10d x 1 1 2 " NAILS 20-1131 C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/4" = 1'-0" 01/19/21 UPPER ROOF FRAMING PLAN S-6 CONNECTOR & LINTEL SCHD. ↓ 678 ↑ 724 SIMPSON 18 (truss)10d x 1 1 2 " NAILS DETAL20 ↑2480 ↑ 2349 max. ZHJ4 MTS12 SIMPSON 14 10d x 1 1 2 " NAILS↑1000 E02G 10d x 1 1 2 " NAILS ↓ 4005 ↑ 2210 ↓ 1444 ↑ 1843 2 (CONC) 12 (header) 3 4 " x 5" TITEN HD 1 4 " x 2 1 2 " SDS ALLOWED LHSM 15.50' NAVD 30" LAP min.30" LAP min.30" LAP min.30" LAP min.30" LAP min.30" LAP min.30" LAP min.30" LAP min.30" LAP min.LONGITUDINAL BUILDING SECTION SCALE: 1/2" = 1'-0"S-7 111'-4"12'-0"9'-4"1'-4"8'-0"2'-0"10'-0"2'-0"9'-4"23'-4" A.F.F.11'-4" A.F.F.32'-8" A.F.F.3'-6"2'-11"LHSM 17.33' NAVD beam top steel slab bottom steel top steel bottom steel coincide w/ slab steel beam bottom steel slab bottom (beyond) STRUCTURAL SLABrefer to plans for specs 2.5" 3" 2.5"2"2.25"3.5"2.25"2"WELD PLATE DETAIL 8"12"3/4" NELSON STUDS (typical) TUBE STEEL COLUMN 30" LAP min.30" LAP min.6"6"16" AUGER-CAST PILE AND 24" TRANSITION CAP (beyond) REFER TO DETAILS slope 16" AUGER-CAST PILE & 24"sq. TRANSITION CAP refer to plans & details 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations 16"x24" CONCRETE TIE BEAM w/ (3) #5's TOP & BOTTOM and #3 STIRRUPS @ 10" O.C. TOP @ +11'-4" Above Finish Floor See RECESS DETAIL sheet S-4 for reinforcement configuration - Refer to BEAM SCHEDULE sheet S-4 FOR additional steel reinforcement required at ends... **CTB-6** 16" AUGER-CAST PILE AND 24" TRANSITION CAP (beyond) REFER TO DETAILS 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations REFER TO ARCHITECTURAL PLANS FOR FASCIA, SOFFIT & DRIP EDGE DETAILS REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING & UNDERLAYMENT... 19/32" CDX PLYWOOD SHEATHING w/ 8d RING SHANK NAILS @ 6" o.c. EDGE & FIELD. TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to typical wall section sheet S-8 TYPICAL 8" CMU MASONRY CONSTRUCTION - refer to typical wall section sheet S-8 8"x24" CONCRETE BEAM (INTERMEDIATE BEAM) w/ (2) #5's TOP & BOTTOM & #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor HYBRIB CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS HYBRIB CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings FRANGIBLE 8" CMU MASONRY CONSTRUCTION refer to sheet S-10 for details & specifications POURED CONCRETE COLUMN (beyond) 8"x21" CONCRETE TIE BEAM w/ (2) #5's TOP, MIDDLE & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-1" Above Finish Floor **BEYOND** TYPICAL 8" CMU MASONRY CONSTRUCTION **SHEARWALL** refer to typical wall section sheet S-8 TYPICAL 8" CMU MASONRY CONSTRUCTION **SHEARWALL** refer to typical wall section sheet S-8 SHEARWALL FOUNDATION @ ELEVATOR PIT refer to FOUNDATION section sheet S-9 for details 16" AUGER-CAST PILE & 24"sq. TRANSITION CAP refer to plans & details 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations POURED CONCRETE COLUMN (beyond) 12"x18" (nominal) CONCRETE BEAM w/ (3) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ -0'-6" Below Finish Floor **CTB-7** 12"x17" CONCRETE TIE BEAM w/ (3) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ -0'-7" Below Finish Floor REFER TO ARCHITECTURAL PLANS FOR RUNOFF CONTROL & REQUIRED RAILING 12" PILASTER BLOCK COLUMN w/ (4) #5 vert. FILLED w/ GROUT REFER TO DETAIL SHEET S-10 16" AUGER-CAST PILE AND 24" TRANSITION CAP REFER TO DETAILS TYPICAL MASONRY CONSTRUCTION w/ S.G.D. POCKET (beyond) S.G.D. per ARCHITECTURALS 8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor **CTB-11** 12"x35" CONCRETE BEAM w/ (3) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +22'-9" Above Finish Floor **CBT-12** BEAM STEPS TO 42" DEPTH BEYOND (CBT-12a) 6" (nominal) STEP (beyond) TYPICAL MASONRY CONSTRUCTION (beyond) REFER TO ARCHITECTURAL PLANS FOR SOFFIT & FASCIA DETAILS PRE-ENGINEERED ROOF TRUSSES by others COMPOSITE PRECAST CONCRETE LINTEL refer to schedule SHEET S-6 for specifications TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section sheet S-8 #5 REBAR in FILLED CELL COLUMN refer to plans for locations (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE (PRECAST LINTELS @ OPENINGS refer to schedule sheet S-6 for specifications) REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE #5x75" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL 16"x48" CONCRETE BEAM (INTERMEDIATE BEAM) w/ (3) #5's TOP, MIDDLE & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor - RECESS BEAM @ S.G.D. OPENING - see recess detail sheet S-5 **CTB-13** TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section sheet S-8 #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section sheet S-8 #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS HYBRID CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS CONCRETE BEAM (beyond) CONCRETE BEAM (beyond) CONCRETE BEAM (beyond) CONCRETE BEAM (beyond)8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP & BOTTOM & #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section sheet S-8 #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL 8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP & BOTTOM & #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section sheet S-8 #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN refer to plans for locations 8"x24" CONCRETE BEAM w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor 8"x24" CONCRETE TIE BEAM w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor POURED CONCRETE COLUMN (beyond) 8"x21" CONCRETE BEAM (CANTILEVER SUPPORT BEAM) w/ (2) #5's TOP, MIDDLE & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-1" Above Finish Floor #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL POURED CONCRETE COLUMN w/ (4) #5 vert. REFER TO SCHEDULE SHEET S-4 8"x21" CONCRETE BEAM (LOWEST HORIZONTAL BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL 312"x312x38" TUBE STEEL COLIMN 3/4" STEEL WELD PLATE REFER TO DETAIL AT LEFT 3/4" STEEL WELD PLATE REFER TO DETAIL ABOVE #5 REBAR LAP 30" w/ COLUMN STEEL #5 REBAR LAP 30" w/ COLUMN STEEL STANDARD HOOK (typ.) STANDARD HOOK (typ.) STANDARD HOOK (typ.) slope slope FINISH FLOOR 8.00 NAVD PRE-ENGINEERED ROOF TRUSSES @ 24" o.c.GIRDER TRUSSGIRDER TRUSSEM B E D M E N T L I N E SIMPSON HETA 20 typical at all trusses unless noted otherwise EM B E D M E N T L I N E SIMPSON HETA20 typical at all trusses unless noted otherwise 8"x24" CONCRETE TIE BEAM (LOWEST HORIZONTAL BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor 12" HOOK in STRUCTURAL SLAB #5 TOP STEEL (typical)16" LAP max.#5 REBAR LAP 16" w/ FILLED CELL COLUMN STEEL 6" MAX. EMBED. #5 REBAR in FILLED CELL COLUMN typical at ends and center of all frangible masonry walls & AT ALL OPENINGS (5'-0" o.c. MAXIMUM) STUB VERT. STEEL into LHSM BEAM 6" MAX. EMBED. REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING & UNDERLAYMENT... 19/32" CDX PLYWOOD SHEATHING w/ 8d RING SHANK NAILS @ 6" o.c. EDGE & FIELD.8'-0"RECESS BEAM FOR S.G.D. as necessaryREFER TO ARCHITECTURAL DRAWINGS4'-0"STEP-UP CONCRETE BEAM TO 21" depth TO COINCIDE w/ FLOOR SYSTEM refer to detail sheet S-4 REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL PLANS FOR RUNOFF CONTROL & REQUIRED RAILING CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONSTRUCTION SET C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS 20-1131 C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION DATE: David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY DATE: Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/2" = 1'-0" 01/19/21 BUILDING SECTION DETAIL S-7 6" step30" LAP min.ALLOWED LHSM 15.50' NAVD 30" LAP min.WALL SECTION @ ENTRY SCALE: 1/2" = 1'-0"S-8 1 ALLOWED LHSM 15.50' NAVD30" LAP min.WALL SECTION @ STAIRS SCALE: 1/2" = 1'-0"S-8 2 ALLOWED LHSM 15.50' NAVD WALL SECTION @ GARAGE SCALE: 1/2" = 1'-0"S-8 3 30" LAP min.16" LAP max.23'-4"3'-2"10" min.30" LAP min.4'-4" TOP VIEW 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations 16" AUGER-CAST PILE & 24" TRANSITION CAP (beyond) - REFER TO DETAILS sheet S-2 & S-3 DRIVEWAY per FDEP PERMIT DROP INTERMEDIATE BEAM 24" @ CANTIVELERED BALCONY ADD (2) #5's AT BOTTOM OF DROP BEAM w/ #3 STIRRUPS @ 12" o.c. 16" AUGER-CAST PILE & 24"sq. TRANSITION CAP refer to plans & details 4" thick 3000psi CONCRETE SLAB FIBERMESH REINF. - FRANGIBLE SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations 16" AUGER-CAST PILE & 24"sq. TRANSITION CAP refer to plans & details2x122x12 2x12 2x126x6 POST NOTCH FOR BEAMS WOOD TO REAMIN slope slope slope (2) 2x12 P.T. HEADER 11'-4"12'-0"9'-4"2'-0"10'-6"FINISH FLOOR 8.00 NAVD FINISH FLOOR 8.00 NAVD 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations1'-2"11'-4"12'-0"9'-4"6x6 P.T. POST SIMPSON CBS66 3" min CLEARANCE (4) 1/2" SS CARRIAGE BOLTSSIMPSON MTS12 TYPICAL AT EACH TRUSS (not shown) REFER TO ARCHITECTURAL PLANS FOR SOFFIT & FASCIA DETAILS 12" HOOK in STRUCTURAL SLAB #5 TOP STEEL #5 TOP STEEL in CANTILEVER BEAM #5 BOTTOM STEEL in CANTILEVER BEAM 8"x21" CONCRETE TIE BEAM w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-1" Above Finish Floor 8" wide CANTILEVERED HAUNCH BEAM (depth varies) w/ (2) #5's TOP & BOTTOM & #3 STIRRUPS @ 12" o.c. 6" STRUCTURAL SLAB (3000psi MINIMUM) w/ #5's @ 10" o.c. TOP STEEL & #4's @ 12" o.c. TEMP. STEEL (beyond) HYBRID CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section sheet S-8 #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL SIMPSON MTS12 TYPICAL AT EACH TRUSS (not shown) REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING & UNDERLAYMENT 19/32" CDX PLYWOOD SHEATHING w/ 8d RING SHANK NAILS @ 6" o.c. EDGE & FIELD. TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section AT RIGHT #5 REBAR LAP 30" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN refer to plans for locations EM B E D M E N T L I N E (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE (PRECAST LINTELS @ OPENINGS refer to schedule sheet S-6 for specs)refer t o main r o ofin g n ot e... REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS HYBRIB CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS SIMPSON HETA 20 typical at all trusses unless noted otherwise PRE-ENGINEERED ROOF TRUSSES @ 24" o.c.GIRDER TRUSSPRE-ENGINEERED ROOF TRUSSES @ 24" o.c.GIRDER TRUSSPRE-ENGINEERED ROOF TRUSSES @ 24" o.c.EMBEDMENT LINE SIMPSON HETA 20 typical at all trusses unless noted otherwise EM B E D M E N T L I N E SIMPSON HETA 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING & UNDERLAYMENT 19/32" CDX PLYWOOD SHEATHING w/ 8d RING SHANK NAILS @ 6" o.c. EDGE & FIELD. (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE (PRECAST LINTELS @ OPENINGS refer to schedule sheet S-6 for specs) REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING & UNDERLAYMENT 19/32" CDX PLYWOOD SHEATHING w/ 8d RING SHANK NAILS @ 6" o.c. EDGE & FIELD. (2) COURSE 8" BOND BEAM (8"x16" nominal dimensions) w/ (1) #5 cont. EACH COURSE (PRECAST LINTELS @ OPENINGS refer to schedule sheet S-6 for specs) REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL PLANS FOR SOFFIT & FASCIA DETAILS REFER TO ARCHITECTURAL PLANS FOR SOFFIT & FASCIA DETAILS REFER TO ARCHITECTURAL PLANS FOR SOFFIT & FASCIA DETAILS FRANGIBLE CONCRETE FOOTER w/ GARAGE DOOR RECESS - REFER TO DETAILS SHEET S-9 HYBRIB CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS 8"x24" CONCRETE TIE BEAM (LOWEST HORIZONTAL BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor 8"x24" CONCRETE BEAM w/ (2) #5's TOP & BOTTOM & #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor 8"x24" CONCRETE TIE BEAM (LOWEST HORIZONTAL BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor DROP BEAM 16" OVER FRONT ENTRY DOORWAY - ADD (2) #5's AT BOTTOM OF DROP BEAM w/ #3 STIRRUPS @ 12" o.c.1'-4"CONCRETE BEAM (beyond)30" LAP min.TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section AT LEFT #5 REBAR in FILLED CELL COLUMN refer to plans for locations #5x52" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL 8"x24" CONCRETE BEAM (INTERMEDIATE BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor 2'-0"REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS TYPICAL 8" CMU MASONRY CONSTRUCTION ALL NON-FRANGIBLE MASONRY WALLS USE 9ga. LADDER TYPE HORIZONTAL REINFORCEMENT AT EVERY OTHER COURSE (16" O.C.) FILLED CELL COLUMNS SHALL BE LOCATED MAX. 4'-0" O.C. & ... a) EACH SIDE OF ANY OPENING b) AT ALL CORNERS c) AT ALL WALL ELEVATION CHANGES d) AS INDICATED ON PLAN #5x52" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN refer to plans for locations 8"x24" CONCRETE TIE BEAM (LOWEST HORIZONTAL BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor HYBRID CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS HYBRIB CONCRETE-STEEL JOIST FLOOR SYSTEM DESIGNED BY OTHERS refer to shop drawings REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS 8"x24" CONCRETE BEAM (INTERMEDIATE BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor #5x52" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN refer to plans for locations 8"x24" CONCRETE BEAM (INTERMEDIATE BEAM) w/ (2) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +23'-4" Above Finish Floor TYPICAL 8" CMU MASONRY CONSTRUCTION refer to typical wall section AT LEFT ENTRY DOOR REFER TO ARCHITECTURAL DRAWINGS 16" AUGER-CAST PILE & 24"sq. TRANSITION CAP refer to plans & details FRONT ENTRY GARAGE 12"x24" CONCRETE TIE BEAM (LOWEST HORIZONTAL BEAM) w/ (3) #5's TOP & BOTTOM and #3 STIRRUPS @ 12" O.C. TOP @ +11'-4" Above Finish Floor FRANGIBLE GARAGE DOOR HEADER 8" CMU MASONRY CONSTRUCTION w/ FILLED CELLS @ CENTER & ENDS (w/ (1) #5 vert. STUB into LHSM BEAM ABOVE w/ MAXIMUM 6" EMBEDDMENT) PRECAST CONCRETE LINTEL (GROUT FILLED) w/ (1) #5 cont. BEARING ON CONCRETE COLUMNS - NOTCH COLUMNS TO RECEIVE LINTEL & FRANGIBLE BLOCK HEADER STUB LINTEL REINFORCEMENT INTO CONCRETE COLUMNS MAXIMUM 6" GARAGE DOOR REFER TO ARCHITECTURAL DRAWINGS #5x52" REBAR LAP 30" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN refer to plans for locations TYPICAL 8" CMU MASONRY CONSTRUCTION refer to specifications above #5 REBAR LAP 16" w/ FILLED CELL COLUMN STEEL FRANGIBLE 8" CMU MASONRY CONSTRUCTION refer to sheet S-10 for details & specifications 6" MAX. EMBED. STUB VERT. STEEL into LHSM BEAM 6" MAX. EMBED. FLOOR SYSTEM CONNECT per MFR - refer to shop drawings FRANGIBLE 8" CMU MASONRY CONSTRUCTION refer to sheet S-10 for details & specifications FRANGIBLE CONCRETE FOOTER REFER TO DETAILS SHEET S-916" LAP max.6" MAX. EMBED. #5 REBAR LAP 16" w/ FILLED CELL COLUMN STEEL #5 REBAR in FILLED CELL COLUMN typical at ends and center of all frangible masonry walls & AT ALL OPENINGS (5'-0" o.c. MAXIMUM) #5 REBAR in FILLED CELL COLUMN typical at ends and center of all frangible masonry walls & AT ALL OPENINGS (5'-0" o.c. MAXIMUM) TYPICAL FRANGIBLE MASONRY CONSTRUCTION (beyond) REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHT AND FINISH MATERIALS REFER TO ARCHITECTURAL DRAWINGS FOR ROOFING & UNDERLAYMENT 19/32" CDX PLYWOOD SHEATHING w/ 8d RING SHANK NAILS @ 6" o.c. EDGE & FIELD. PRE-ENGINEERED ROOF TRUSSES @ 24" o.c. EM B E D M E N T L I N E SIMPSON HETA 20 typical at all trusses unless noted otherwise REFER TO ARCHITECTURAL PLANS FOR SOFFIT & FASCIA DETAILS REFER TO ARCHITECTURAL PLANS FOR RUNOFF CONTROL & REQUIRED RAILING CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONSTRUCTION SET C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS 6mil VISQUEEN (or equivalent) VAPOR BARRIER & TERMITE TREATMENT REQUIRED UNDER ALL INTERIOR SLABS & FOUNDATIONS ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS 20-1131 MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 1/2" = 1'-0" 01/19/21 S-8WALL SECTION DETAILS DATE:DATE: 6mil VISQUEEN (or equivalent) VAPOR BARRIER & TERMITE TREATMENT REQUIRED UNDER ALL INTERIOR SLABS & FOUNDATIONS ELEVATOR PIT DETAIL SCALE: 3/4" = 1'-0"2'-0"F2 FOUNDATION SECTION SCALE: 3/4" = 1'-0" F1 FOUNDATION SECTION SCALE: 3/4" = 1'-0"18"12" 10"112"SCALE: 3/4" = 1'-0" FOUNDATION SECTION SCALE: 3/4" = 1'-0"18"12" F312"FOUNDATION SECTION SCALE: 3/4" = 1'-0"20"12" F412"F67"18"12"12"SHEAR WALL FOOTING @ INTERIOR VAPOR BARRIER 3" MIN. PILE EMBEDMENT24"22" 16"2'-6"8" VAPOR BARRIER 3" MIN. PILE EMBEDMENT24"22" 16" 4'-6" VAPOR BARRIER 24"VAPOR BARRIER over16" LAP5'-9" VAPOR BARRIER VAPOR BARRIER 16" LAPFOUNDATION SECTION SCALE: 3/4" = 1'-0"18"12" F56"VAPOR BARRIER 16" LAPFOUNDATION SECTION SCALE: 3/4" = 1'-0" 12" F7 VAPOR BARRIER 16" LAP2" MIN COVERAGE typ. for all slab steel 7" STRUCTURAL SLAB (elevator pit base) - #4's 12" O.C.E.W. STANDARD HOOK (typ.) CONCRETE COLUMN or MASONRY WALL (beyond) PAVER DRIVE 112" RECESS 18"deep x 12" 3000psi CONCRETE MONOLITHIC FOOTER **FRANGIBLE** 6mil VISQUEEN VAPOR BARRIER over TERMITE TREATED COMPACTED FILL (98% max. density) AUGER CAST PILE (beyond) TRANSITION CAP (beyond) 18"deep x 12" 3000psi CONCRETE FOOTING **FRANGIBLE** FINISH GRADE AUGER CAST PILE (beyond) TRANSITION CAP (beyond) 20"deep x 12" 3000psi CONCRETE MONOLITHIC FOOTER **FRANGIBLE** #5 in GROUT FILLED CELL 6" MAX. EMBEDMENT 6mil VISQUEEN VAPOR BARRIER over TERMITE TREATED COMPACTED FILL (98% max. density) AUGER CAST PILE (beyond) TRANSITION CAP (beyond) (2) #5's CONT. 3" MIN. PROTECTION - DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer to TYPICAL PILE @ PILE CAP detail sheet S-3 (similar) (2) #5's CONT. w/ 3" MIN. PROTECTION - DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer to TYPICAL PILE @ PILE CAP detail sheet S-3 (similar) (2) #5's (3" MIN. PROTECTION) DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer to TYPICAL PILE @ PILE CAP detail sheet S-3 (similar) (2) #5's SHALL BE CONTINUOUS AT ALL SHEARWALL FOOTINGS - refer to plans for locations 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations TYPICAL FOR ALL FRANGIBLE SLABS FINISH GRADE AUGER CAST PILE (beyond) TRANSITION CAP (beyond) 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations refer to FRANGIBLR WALL DETAILS (sheet S-10) for masonry construction specifications (2) #5's (3" MIN. PROTECTION) DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer to TYPICAL PILE @ PILE CAP detail sheet S-3 (similar) (2) #5's SHALL BE CONTINUOUS AT ALL SHEARWALL FOOTINGS - refer to plans for locations clean termite treated compacted granular fill 4" frangible SLAB @ -1'-0" B.F.F. 22" x 24" deep FOOTING w/ (3) #5's CONT. (top & bottom) & #3 STIRRUPS @ 16" O.C. - TYPICAL at ALL SHEAR WALLS & ELEVATOR WALLS TYPICAL AUGER CAST PILE REFER TO DETAILS clean termite treated compacted granular fill STANDARD HOOK MASONRY SHEARWALL refer to BUILDING SECTION (sheet S-8) for masonry construction specifications 4" frangible SLAB @ -11'-0" B.F.F. EXPANSION JOINT per contractor 8" THICKENED EDGE w/ (1) #5 cont. EXPANSION JOINT per contractor 22" x 24" deep FOOTING w/ (3) #5's CONT. (top & bottom) & #3 STIRRUPS @ 16" O.C. - TYPICAL at ALL SHEAR WALLS & ELEVATOR WALLS TYPICAL AUGER CAST PILE REFER TO DETAILS HOOK SLAB BOTTOM STEEL INTO GRADE BEAM AS SHOWN clean termite treated compacted granular fill 4" frangible SLAB @ -0'-6" B.F.F. 8" THICKENED EDGE w/ (1) #5 cont. (typ.) 22" x 24" deep FOOTING w/ (3) #5's CONT. (top & bottom) & #3 STIRRUPS @ 16" O.C. - TYPICAL at ALL SHEAR WALLS & ELEVATOR WALLS clean termite treated compacted granular fill 18"deep x 12" 3000psi CONCRETE MONOLITHIC FOOTING **FRANGIBLE** 6mil VISQUEEN VAPOR BARRIER over TERMITE TREATED COMPACTED FILL (98% max. density) #5 LAP STEEL 6" MAX. EMBEDMENT 4" thick FRANGIBLE SLAB (GARAGE - SLOPED - refer to plan for details) 4" thick FRANGIBLE SLAB @ FINISH FLOOR clean termite treated granular fill **FRANGIBLE WALL** EXPANSION JOINT per contractor APPLY WATERPROOFING TO MASONRY WALL PRIOR TO BACKFILLING MASONRY SHEARWALL refer to BUILDING SECTION (sheet S-8) for masonry construction specifications MASONRY SHEARWALL refer to BUILDING SECTION (sheet S-8) for masonry construction specifications MAXIMUN LAP @ FRANGIBLE MASONRY WALL CONSTRUCTION clean termite treated compacted granular fill 4" frangible SLAB @ -0'-6" B.F.F. SLAB ELEVATION MAY VARY - REFER TO SHEET S-3 FINISH FLOOR 4" frangible SLAB @ -1'-0" B.F.F. refer to FRANGIBLR WALL DETAILS (sheet S-10) for masonry construction specifications MAXIMUN LAP @ FRANGIBLE MASONRY WALL CONSTRUCTION 6" MAX. EMBEDMENT 18"deep x 12" 3000psi CONCRETE MONOLITHIC FOOTER **FRANGIBLE** #5 in GROUT FILLED CELL 6" MAX. EMBEDMENT 6mil VISQUEEN VAPOR BARRIER over TERMITE TREATED COMPACTED FILL (98% max. density) AUGER CAST PILE (beyond) TRANSITION CAP (beyond) (2) #5's CONT. w/ 3" MIN. PROTECTION - DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer to TYPICAL PILE @ PILE CAP detail sheet S-3 (similar) 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations TYPICAL FOR ALL FRANGIBLE SLABS4" thick FRANGIBLE SLAB clean termite treated granular fill **FRANGIBLE WALL** 4" frangible SLAB refer to FRANGIBLR WALL DETAILS (sheet S-10) for masonry construction specifications MAXIMUN LAP @ FRANGIBLE MASONRY WALL CONSTRUCTION 6" MAX. EMBEDMENT CONCRETE COLUMN (beyond) REFER TO SHEET S-3 FOR SLAB ELEVATIONS 18"deep x 12" 3000psi CONCRETE MONOLITHIC FOOTER **FRANGIBLE** #5 in GROUT FILLED CELL 6" MAX. EMBEDMENT 6mil VISQUEEN VAPOR BARRIER over TERMITE TREATED COMPACTED FILL (98% max. density) AUGER CAST PILE (beyond) TRANSITION CAP (beyond) (2) #5's CONT. w/ 3" MIN. PROTECTION - DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - refer to TYPICAL PILE @ PILE CAP detail sheet S-3 (similar) 4" thick FRANGIBLE SLAB clean termite treated granular fill **FRANGIBLE WALL** 4" frangible SLAB refer to FRANGIBLR WALL DETAILS (sheet S-10) for masonry construction specifications MAXIMUN LAP @ FRANGIBLE MASONRY WALL CONSTRUCTION 6" MAX. EMBEDMENT GARAGE SLAB @ -1'-0" B.F.F. clean termite treated granular fill GARAGE SLAB @ -1'-0" B.F.F. SLAB TRANSITION SECTION SCALE: NOT TO SCLAE EQUIPMENT PAD @ FINISH FLOOR HALLWAY (ACCESS) @ FINISH FLOOR LAUNDRY AREA @ -0'-6" B.F.F. GARAGE AREA @ -1'-0" B.F.F. 4" thick 3000psi CONCRETE SLAB - FIBERMESH REINF. - FRANGIBLE - SAW CUT into 5'x5' max. SECTIONS - refer to plans for cut locations TYPICAL FOR ALL FRANGIBLE SLABS 18"deep x 12" 3000psi CONCRETE MONOLITHIC FOOTER **FRANGIBLE** w/ (2) #5's CONT. w/ 3" MIN. PROTECTION - DISCONTINUE STEEL MIN. 3" FROM TRANSITION CAP - TYPICAL FOR ALL FRANGIBLE FOUNDATIONS UNLESS NOTEDFRANGIBLE MASONRY WALLFRANGIBLE MASONRY WALLFRANGIBLE MASONRY WALL (BEYOND)FRANGIBLE MASONRY WALLFRANGIBLE SLAB FRANGIBLE SLAB FRANGIBLE SLAB VAPOR BARRIER typical THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. CONSTRUCTION SET C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m "VAPOR BARRIER" SHALL BE 6mil VISQUEEN (or equivalent), UNLESS NOTED OTHERWISE. "VAPOR BARRIER" SHALL BE 6mil VISQUEEN (or equivalent), UNLESS NOTED OTHERWISE. 20-1131 MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK 3/4" = 1'-0" 01/18/21 S-9FOUNDATION DETAILS DATE:DATE: CONCRETE TIE BEAM 4" MIN FORM-POUR 8"x8" (min.) CONCRETE SILL w/ (1) #5 or PRECAST CAST-CRETE SILL (or equal) @ DROPPED HEADER SCALE: NOT TO SCLAE DOOR /WINDOW OPENING FOUNDATION or CONCRETE BEAM (below) LAP VERT. STEEL & STANDARD HOOK A MINIMUM OF 48 BAR DIAMETERS (30"min.) 8" #5 VERT. IN FILLED CELL COLUMN (typ.) (1) 24"x24"x#5 CORNER each side ADD (1) #5 cont. @ BOTTOM OF DROP BEAM - LAP w/ CORNER BARS 4" MIN varies90" max. WINDOW OPENING DEMONSTRATED - DOOR OPENING IS SIMILAR (no sill, etc.) MASONRY ROUGH OPENING - REFER TO ARCHITECTURALS TYPICAL C.M.U. MASONRY WALL 45 DEG. MITER CUT@ PRECAST LINTELCORNER COLUMN BELOW #5 CORNER BAR w/24" LEG #5 BAR(TYP.) CORNER DETAILPRECAST LINTEL SCALE: 3/4" = 1'-0" COMPOSITE LINTEL or CONCRETE BEAM CONCRETE BLOCK WALL 4" MIN 4" MIN CELL COLUMN (typ.) OPEN FOR WINDOW NOTE: POUR SOLID 8" DEEP (MIN) @ EACH WINDOW SILL PRECAST CAST-CRETE SILLS MAY BE USED IN LIEU OF POURED SILL OPENING DETAIL SCALE: NOT TO SCLAE TYPICAL WINDOW CONCRETE TIE BEAM or FOUNDATION #5 VERT. IN FILLED EXISTING LAP VERT. STEEL & STANDARD HOOK A MINIMUM OF 48 BAR DIAMETERS LAP VERT. STEEL & CORNER BAR A MINIMUM OF 24" 24"24" DOUBLE FILLED CELL MASONRY COLUMN w/ (1) #5 VERT. IN EA. CELL. LAPPED @ FOOTING AND EXTENDED INTO TIE/BOND BEAM. FILL w/ 3000 PSI CONCRETE. (REFER TO PLANS FOR SPECIFIC LOCATIONS) FILLED CELL MASONRY COLUMN w/ (1) #5 VERT. IN CELL. LAPPED @ FOOTING AND EXTENDED INTO TIE/BOND BEAM. FILL w/ 3000 PSI CONCRETE. (REFER TO PLANS FOR SPECIFIC LOCATIONS) COLUMN DETAIL FILLED CELLS SHALL BE LOCATED NO FURTHER APART THAN 48" O.C., UNLESS SPECIFICALLY DIMENSIONED 12" FILLED CELL MASONRY COLUMN w/ (2) #5 VERT. EXTENDED CELL. LAPPED @ FOOTING AND EXTENDED INTO TIE/BOND BEAM. FILL w/ 3000 PSI CONCRETE. (REFER TO PLANS FOR SPECIFIC LOCATIONS) 12" PILASTER BLOCK COLUMN w/ (4) #5 VERT. IN EA. CELL. LAPPED @ FOOTING AND EXTENDED INTO TIE BEAM. FILL w/ 3000 PSI CONCRETE. (REFER TO PLANS FOR SPECIFIC LOCATIONS) SCALE: 3/4" = 1'-0" GLASS 2x P.T. BUCK 14 " x 3" TAPCON WINDOW FRAME HEADER DETAIL LINTEL JAMB DETAIL BUCK/FRAME ATTACHMENT GLASS 2x P.T. BUCK 14 " x 3" TAPCON WINDOW FRAME 2x (MAX.) P.T. WINDOW BUCK FASTEN TO C.B.S. w/ 14 "x2 34" MIN. TAPCONS 6" MAX. FROM ENDS AND 12" O/C MAX. (TYP. THREE SIDES) OPTIONAL FASTENING: 14 "x3" MIN. TAPCONS THRU FRAME, BUCK & INTO C.B.S. (112" MIN. EMBEDMENT). TAPCONS REQ'D AT EACH SCREW LOCATION PROVIDED BYMANUFACTURER **DETAILS ABOVE DEPICT THIS OPTION** REFER TO ARCHITECTURAL PLANS FOR FURTHER DETAILS 1x (MIN.) P.T. WINDOW BUCK FASTEN TO C.B.S. w/ 316 "x214 " MIN. TAPCONS 6" MAX. FROM ENDS AND 12" O/C MAX. (TYP. THREE SIDES) OPTIONAL FASTENING (WINDOW & DOOR) BUCK ATTACHMENT DETAILS SCALE: not to scale Straps may be installed straight or wrapped over to achieve listed loads PRE ENGINEERED WOOD TRUSS SIMPSON DETAL20 (2) 10d x 1 12" NAILS into TRUSS CONNECTOR DETAILS SCALE: NOT TO SCALE SIMPSON HETA20 5 NAILS (OF REQ'D) MUST BE INSTALLED INTO TRUSS SEAT CONCRETE OR BLOCK BEAM PRE ENGINEERED WOOD TRUSS - SINGLE PLY 4" MIN. EMBED SIMPSON HETA20 w/ (9) 10dx112" NAILS4" min.SIMPSON DETAL20 w/ (18) 10d x 1 12" NAILS CONCRETE OR BLOCK BEAM PRE ENGINEERED WOOD TRUSS WOOD HEADER H16 w/ (10) 10d x 1 12" NAILS into HEADER SIMPSON H16 HEADS, SPACED AS REQUIRED BY MANUFACTURER AT EACH SIDE. 7' HIGH DOOR: 5-3/8" X 1-7/8" LAG SCREWS WITH WASHER HEADS, SPACED AS REQUIRED BY MANUFACTURER AT EACH SIDE. 8' HIGH DOOR: 6-3/8" X 1-7/8" LAG SCREWS WITH WASHER TRACK BRACKETS TO PT BUCK 2X6 P.T. AT HEIGHT OF DOOR SET 1/2" INTO OPENING GARAGE DOOR HARDWARE MINIMUM 2"∅ X 1/8" WASHERS AT 12"O.C. AND 6" AT ENDS 1/2" X 6" EXP. ANCHOR WITH STUCCO RETURN EXTERIOR FACE OF WALL WEATHER-PROOFING, AS REQUIRED BY THE FBC, TYPICAL AT ALL OPENINGS - REFER TO ARCHITECHURAL PLANS FOR DETAILS CONSTRUCTION SET C: \ U s e r s \ P H I L I P ~ 1 \ A p p D a t a \ L o c a l \ T e m p \ B r i c s C A D \ b p _ 0 \ R E E D S T R U C T U R A L _ 1 . 0 . d w g b y P h i l i p P e p e o n J a n 2 0 , 2 0 2 1 - 1 1 : 5 1 a m THESE PLANS ARE NOT FOR CONSTRUCTION UNLESS STAMPED "Construction Set", DATED, SIGNED AND SEALED BY THE ENGINEER. ALL CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL JURISDICTIONAL PERMITS, CONDITIONS AND CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ALL DETAILS AND ELEVATIONS WITH ARCHITECT PRIOR TO CONSTRUCTION. 3 2 3 1 2 2 2 1 2 2 2 1 2 2 1 2 2 2 3 3 WIND SPEED UPLIFT REQUIREMENTS. MANUFACTURERS REQUIREMENTS TO MEET THE SPECIFIED DESIGN ROOFING MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ROOF ZONE ROOFING PRESSURE POSITIVE PRESSURE NEGATIVE 1st/2nd FLOOR a = 5.0' (10% of 50' least horz. dimension) & FLOOR Zone 1 - 2nd Floor 29.8 psf 82.4 psf 47.4 psf Zone 2 - 2nd Floor Zone 3 - 2nd Floor 4 5 5 5 5 4 COMPONENTS & CLADDING EXTERIOR WALL COMPONENTS SHALL BE ATTACHED PER MANUFACTURERS' SPECIFICATIONS TO MEET THE WIND PRESSURES SHOWN (FIRST FLOOR ON PLAN AT RIGHT. ALL CLADDING SHALL MEET OR EXCEED THE DESIGN PRESSURES LISTED BELOW. WALL ZONE PRESSURE POSITIVE PRESSURE NEGATIVE Zone 4 - (interior zone) 51.7 psf 69.3 psf 56.1 psf Zone 5 - (end zone) COMPONENT/CLADDING CALCULATIONS BASED ON ASCE 7-10 with 170 MPH Vult, EXPOSURE D ENCLOSED, 30' MEAN HEIGHT, 7:12 PITCH, with Kd=0.85 using the ALLOWABLE STRESS DESIGN method. 3rd FLOOR a = 3.0' (10% of 30' least horz. dimension) 29.8 psf 29.8 psf 82.4 psf 51.7 psfCONC. COLUMNCONC. BEAM w/ STEEL REINFORCEMENT varies16" FRANGIBLE WALL DETAIL SCALE: not to scale TYP. 6" max. embedment TYP. 6" max. embedmentFRANGIBLE 8" C.M.U. MASONRY WALL (NO LADDER TYPE HORIZONTAL REINFORCEMENT ) #5 in FILLED CELL COLUMN @ CENTER & ENDS (COLUMNS) FRANGIBLE FOOTING discontinue steel @ transition caps18"24"TRANSITION CAP & 16" AUGER PILE FLOOD VENT per ARCHITECT UNFILLED PRECAST CONCRETE LINTEL 16"#5 LAP BAR REINFORCEMENT ALL ENCLOSED SPACES BELOW THE BASE FLOOD ELEVATION SHALL BE PROPERLY VENTED IN ACCORDANCE WITH FBC REGULATIONS - USE CAST-CRETE 8U8 PRECAST CONCRETE LINTELS (or equivalent) ABOVE ALL REQUIRED FLOOD VENTS IN MASONRY WALL APPLICATIONS - REFER TO ARCHITECTURAL DRAWINGS FOR VENT LOCATIONS 20-1131 MARK SHEET PROJECT NO.KMA Engineering & Surveying, LLC Phone: (772) 569-5505 Fax: (772) 569-1455 E-Mail: civil@kmafl.com Certificate of Authorization Number: 33705 Consulting Engineers & Surveyors DESIGNED DRAWN CHECKED SCALE DATEDATEREVISION David S. Knight, P.E. Fl. Reg No. 41060 80 Royal Palm Pointe, Suite 401 Vero Beach, Fl. 32960 BY Scott B. McGuire, P.E. Fl. Reg No. 39573 REED RESIDNCE St Lucie County, Florida ENGINEERING & SURVEYING KMA DSK PMP DSK AS NOTED 01/19/21 S-10MISCELLANEOUS DETAILS DATE:DATE: