Loading...
HomeMy WebLinkAboutCompaction report dated 1.25.21ww"uArdamanin-Place Density Report M& & Associates, Inc. Permit # 2011-0280 Report Date: 1/25/2021 Port St. Lucie Branch Test Method: ASTM D6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone:772-878.0072 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture % In Place Dry Density pc In Place Wet Density (pc Probe Depth (in) Percent Compaction Min Comp. N Remark 406 1/15/21 21-018 (Modified A - 11.0 109.5 7.1 108.4 116.1 12 99 95 Pass 407 1/15/21 21-018 (Modified) A - 11.0 109.5 5.0 108.9 114.3 12 99 95 Pass 408 1/15/21 21-018 (Modified) A 11.0 109.5 6.9 107.0 114.4 12 98 95 Pass 409 1/16/21 21-018 (Modified) A 11.0 109.5 7.6 106.9 115.0 12 98 95 Pass 410 1/16/21 21-018 (Modified) A 11.0 109.5 9.0 108.3 118.0 12 99 95 Pass 411 1/15/21 21-018 Modified A 11.0 109.5 6.4 107.3 114.2 12 98 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 406 Building Pad Fill: Lot 94, 9795 Palm Breezes Drive. NW End of Pad -1.0 Top of pad CPN / MC-3 / M340507396 / Tech, Port St. Lucie 407 Building Pad Fill: Lot 94, 9795 Palm Breezes Drive. NE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 408 Building Pad Fill: Lot 94, 9795 Palm Breezes Drive. SE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 409 Footings: Lot 94, 9795 Palm Breezes Drive. SE End of Footings -2.0 Top of pad CPN / MC-3 / M340507395 / 1 Tech, Port St. Lucie 410 Footings: Lot 94, 9795 Palm Breezes Drive. SW End of Footings 1 -2.0 ITop of pad CPN / MC-3 / M340507395 / JTech, Port St. Lucie 411 Footings: Lot 94, 9795 Palm Breezes Drive. NW End of Footings 1 -2.0 JTop of pad CPN / MC-3 / M340507395 ITech, Port St. Lucie Remarks Comments ; Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. Ardaman In -Place Density Report client: Project: & Associates, Inc. Permit # 2011-0280 Renar Development Corp. 113-15-66-5434B Report Date: 1/25/2021 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce Florida Registration No. 5950 Fort Pierce, FL 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone:772-878-0072 J. * No. 63911 '7A = r t sr�, F t e . a : Ar ©NAL This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Jan 25, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.