HomeMy WebLinkAboutCompaction testmw'uArdamanln-Place Density Report
& Associates, Inc. Permit # 2011-0259
Report Date: 2/11/2021
Port St. Lucie Branch Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie,
Phone:772-878-0072
Client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
Test Results
Maximum
In Place
In Place
Optimum
Dry
In Place
Dry
Wet
Probe
Retest
Soil
Moisture
Density (pcf)
Moisture
Density
Density
Depth
Percent
Min Comp.
Test #
Of
Test Date
Proctor ID
Method
Classification
(%
(%
(pcf)
pcf)
(in)
Compaction
%
Remark
418
1/29/21
21-033
A
--
10.5
116.5
9.8
111.9
122.9
12
96
95
Pass
(Modified)
419
1/29/21
21-033
A
--
10.5
116.5
10.8
110.9
122.9
12
95
95
Pass
Modified
420
1/29/21
21-033
A
--
10.5
116.5
8.7
111.1
120.8
12
95
95
Pass
(Modified)
421
1/29/21
21-033
A
--
10.5
116.5
10.3
113.2
124.9
12
97
95
Pass
(Modified)
422
1/29/21
21-033
A
-
10.5
116.5
11.4
112.2
125.0
12
96
95
Pass
(Modified)
423
1/29/21
1 21-033
A
-
10.5
1 116.5
9.3
111.4
121.8
12
96
95
Pass
Modified
Test
Information
Gauge
Test #
Test Location
Elevation
Reference
Make / Model / SN / Calibrated
Field Technician
418
Building Pad Fill: House Pad at 9558 Seaspray Drive, Lot 46. NW End of Pad
-1.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
419
Building Pad Fill: House Pad at 9558 Seaspray Drive, Lot 46. NE End of Pad
-1.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
420
Building Pad Fill: House Pad at 9558 Seaspray Drive, Lot 46. SE End of Pad
-1.0
Top of pad
CPN / MC-3 I M340507395 /
Tech, Port St. Lucie
421
Building - Continuous Footing: Footings at 9558 Seaspray Drive, Lot 46. SE End of
-2.0
Top of pad
CPN / MC-3 I M340507795 /
Tech, Port St. Lucie
Footings
422
Building - Continuous Footing: Footings at 9558 Seaspray Drive, Lot 46. SW End of
-2.0
Top of pad
CPN / MC-3/ M340507395 /
Tech, Port St. Lucie
Footings
423
Building - Continuous Footing: Footings at 9558 Seaspray Drive, Lot 46. NW End of
-2.0
Top of pad
CPN / MC-3 / M340507395 /
Tech, Port St. Lucie
Footings
Remarks
Comments
Pass: Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
1"Backscatter".
Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
Ardaman In -Place Density Report
& Associates, Inc. Permit # 2011-0259
Report Date: 2/11/2021
Port St. Lucie Branch Test Method: ASTM D6938
Florida Registration No. 5950
460 NW Concourse Place, Unit 1
Port St. Lucie,
Phone:772-878.0072
Client: Project:
Renar Development Corp. 113-15-66-5434B
3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Stuart, FL 34996 Fort Pierce
Fort Pierce, FL
t
No. 63911 ' 7A'
iA OF 4r
�f `• pP % t>�'
EIIIIIt
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Feb 11, 2021 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.