Loading...
HomeMy WebLinkAboutCompaction testmw'uArdamanln-Place Density Report & Associates, Inc. Permit # 2011-0259 Report Date: 2/11/2021 Port St. Lucie Branch Test Method: ASTM D6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone:772-878-0072 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL Test Results Maximum In Place In Place Optimum Dry In Place Dry Wet Probe Retest Soil Moisture Density (pcf) Moisture Density Density Depth Percent Min Comp. Test # Of Test Date Proctor ID Method Classification (% (% (pcf) pcf) (in) Compaction % Remark 418 1/29/21 21-033 A -- 10.5 116.5 9.8 111.9 122.9 12 96 95 Pass (Modified) 419 1/29/21 21-033 A -- 10.5 116.5 10.8 110.9 122.9 12 95 95 Pass Modified 420 1/29/21 21-033 A -- 10.5 116.5 8.7 111.1 120.8 12 95 95 Pass (Modified) 421 1/29/21 21-033 A -- 10.5 116.5 10.3 113.2 124.9 12 97 95 Pass (Modified) 422 1/29/21 21-033 A - 10.5 116.5 11.4 112.2 125.0 12 96 95 Pass (Modified) 423 1/29/21 1 21-033 A - 10.5 1 116.5 9.3 111.4 121.8 12 96 95 Pass Modified Test Information Gauge Test # Test Location Elevation Reference Make / Model / SN / Calibrated Field Technician 418 Building Pad Fill: House Pad at 9558 Seaspray Drive, Lot 46. NW End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 419 Building Pad Fill: House Pad at 9558 Seaspray Drive, Lot 46. NE End of Pad -1.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie 420 Building Pad Fill: House Pad at 9558 Seaspray Drive, Lot 46. SE End of Pad -1.0 Top of pad CPN / MC-3 I M340507395 / Tech, Port St. Lucie 421 Building - Continuous Footing: Footings at 9558 Seaspray Drive, Lot 46. SE End of -2.0 Top of pad CPN / MC-3 I M340507795 / Tech, Port St. Lucie Footings 422 Building - Continuous Footing: Footings at 9558 Seaspray Drive, Lot 46. SW End of -2.0 Top of pad CPN / MC-3/ M340507395 / Tech, Port St. Lucie Footings 423 Building - Continuous Footing: Footings at 9558 Seaspray Drive, Lot 46. NW End of -2.0 Top of pad CPN / MC-3 / M340507395 / Tech, Port St. Lucie Footings Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as 1"Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. Ardaman In -Place Density Report & Associates, Inc. Permit # 2011-0259 Report Date: 2/11/2021 Port St. Lucie Branch Test Method: ASTM D6938 Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, Phone:772-878.0072 Client: Project: Renar Development Corp. 113-15-66-5434B 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Stuart, FL 34996 Fort Pierce Fort Pierce, FL t No. 63911 ' 7A' iA OF 4r �f `• pP % t>�' EIIIIIt This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Feb 11, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.