In-Place Density Test Report
Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Mark Rogers
1430 Culver Drive, NE
Palm Bay, FL 32907
Date Tested:02/10/2021
Project:18-5043.03 CREEKSIDE
Yorktown Drive & Okeechobee Road, Fort Pierce, County, FL
Type of Test:
Area Tested:Lot 80: 3337 Trinity Circle Permit # 2011-
0178
Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northeast corner of lot 0-1 ft 118.6 10.8 113.8 10.4 96 Pass
2 Southwest corner of lot 0-1 ft 118.6 10.8 115.0 10.3 97 Pass
3 Center of lot 0-1 ft 118.6 10.8 116.0 10.4 98 Pass
Remarks:Above stripped surface 1-2, 2-3’ HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the
relative density of the soil.
Permit # 2011-0178
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
John Kent
Senior Project Engineer