HomeMy WebLinkAboutCompaction reportUES Project No: Workorder No: Report Date: 3360.1800067.0000 224745-1 02/16/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Mark Rogers 1430 Culver Drive, NE Palm Bay, FL 32907 Date Tested:02/10/2021 Project:18-5043.03 CREEKSIDE Yorktown Drive & Okeechobee Road, Fort Pierce, County, FL Type of Test: Area Tested:Lot 81: 3341 Trinity Circle Permit # 2011- 0170 Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of lot 0-1 ft 118.6 10.8 116.2 10.5 98 Pass 2 Southwest corner of lot 0-1 ft 118.6 10.8 115.4 10.9 97 Pass 3 Center of lot 0-1 ft 118.6 10.8 115.2 10.3 97 Pass Remarks:Above stripped surface 1-2, 2-3’ HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil. Permit # 2011-0170 Reviewed By GFA International, Inc Certificate of Authorization No. 4930 John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1