HomeMy WebLinkAboutEngineered letter File C;®py
T reasure Harvey E. Koehnen
C oast Professional Engineer #32831
B u i ld i ng Architect #AR0009471
E ngineers, Certified Gene Contractor #CGCO24776
Inc. IV
July 5, 2017 JUL 0 5 2017
To: St.Lucie County Building Department
Ll
Re: Permit# 1765 â0 3 q6 BY. ft
Owner: Jim&Betty Jones
Address: Sneed Road,Fort Pierce,FL.
Contractor: PACE 2000 Inc.
Arch/Eng: TCBE,Harvey Koehnen
To Whom It May Concern:
This letter is to clarify two points on the above referenced plans. First the lower cord support(a.k.a.rat
runs) shall be installed @ 10'-0"o.c. and attached to bot. cord of trusses with minimum 8d nails. Also
the interior none bearing walls will be constructed as per following detail:
J
J
TRUSSES
U_
0
METAL CHANNEL o
tâ
)¢" DRYWALL ON
EA. SIDE OF WALL
2"x3%" 25 GA. o
METAL STUDS @
16" O.C.
METAL CHANNEL
FASTENED TO 2"x4"
W/ MIN 1" LONG
SCREWS @ 24" O.C.
P.T. 2"x4" FASTENED
TO CONC. W/ CUT
NAILS @ 32" O.C.
TYP. CONC.
SLAB
INTERIOR WALL
PARTITION
SCALE: N.T.S._
T C B E,Inc. 7205 Elyse Circle Phone (772)466-5509
Port Saint Lucie Fax (772)489-3035
Florida 34952-8212 E-mail hkoehnen@tcbeweb.COm
Web site http://www.tcbeweb.com
With these changes the above referenced plans are in compliance with the 2014 FBC 5 h Edition and all
local ordinances.If you have any questions,please call our office.
Respectfully Submitted,
o"
Harvey E.Koehnen,PE 32831
President
a
T C B E,Inc. 7205 Elyse Circle Phone (772)466-5509
Port Saint Lucie Fax (772)489-3035
Florida 34952-8212 E-mail hkoehnen@tcbeweb.COm
Web site http://www.tcbeweb.com