HomeMy WebLinkAboutEngineered letter File C;®py T reasure Harvey E. Koehnen C oast Professional Engineer #32831 B u i ld i ng Architect #AR0009471 E ngineers, Certified Gene Contractor #CGCO24776 Inc. IV July 5, 2017 JUL 0 5 2017 To: St.Lucie County Building Department Ll Re: Permit# 1765 —0 3 q6 BY. ft Owner: Jim&Betty Jones Address: Sneed Road,Fort Pierce,FL. Contractor: PACE 2000 Inc. Arch/Eng: TCBE,Harvey Koehnen To Whom It May Concern: This letter is to clarify two points on the above referenced plans. First the lower cord support(a.k.a.rat runs) shall be installed @ 10'-0"o.c. and attached to bot. cord of trusses with minimum 8d nails. Also the interior none bearing walls will be constructed as per following detail: J J TRUSSES U_ 0 METAL CHANNEL o t— )¢" DRYWALL ON EA. SIDE OF WALL 2"x3%" 25 GA. o METAL STUDS @ 16" O.C. METAL CHANNEL FASTENED TO 2"x4" W/ MIN 1" LONG SCREWS @ 24" O.C. P.T. 2"x4" FASTENED TO CONC. W/ CUT NAILS @ 32" O.C. TYP. CONC. SLAB INTERIOR WALL PARTITION SCALE: N.T.S._ T C B E,Inc. 7205 Elyse Circle Phone (772)466-5509 Port Saint Lucie Fax (772)489-3035 Florida 34952-8212 E-mail hkoehnen@tcbeweb.COm Web site http://www.tcbeweb.com With these changes the above referenced plans are in compliance with the 2014 FBC 5 h Edition and all local ordinances.If you have any questions,please call our office. Respectfully Submitted, o" Harvey E.Koehnen,PE 32831 President a T C B E,Inc. 7205 Elyse Circle Phone (772)466-5509 Port Saint Lucie Fax (772)489-3035 Florida 34952-8212 E-mail hkoehnen@tcbeweb.COm Web site http://www.tcbeweb.com