Loading...
HomeMy WebLinkAboutProduct Approval - HR Window File COPY M IAM I•DADE MIAMI-DADE COUNTY e PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 - BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) w - www.miamidade.sov/economy '- PGT Industries,Inc. 1070 Technology Drive North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami—Dade County Product Control Section (In Miami—Dade County)and/or the AHJ(in areas other than Miami—Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code,including the High Velocity Hurricane Zone. DESCRIPTION: Series"1111-710"Aluminum Horizontal Rolling Window-L.M.I. APPROVAL DOCUMENT: Drawing No. 4127-10, titled "Alum. Horizontal Roller Window, Impact", sheets 1 through 1 I of 11,dated 02/28/06,with revision G dated'05/05/16,prepared by manufacturer, signed f _ and sealed by Anthony Lynn Miller,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. t This NOA revises NOAH 15-0519.09 and consists of this page 1 and evidence pages E-1,E-2 and E-3,as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez,P.E. NOA No.16-0714.13 MIAMI-DADE COUNTYIE .Expiration Date: December 21,2021 Approval Date: September 01,2016 Page 1 s i• PGT Industries,Inc. j NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer`s die drawings and sections. (Submitted under NOA Is No. 07-081 S.09 and 06-0409.06) 2. Drawing No.4127-10,titled"Alum.Horizontal Roller Window,Impact", sheets 1 through 11 of 11,dated 02/28/06,with revision G dated 05/05/16,prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC, TAS 202-94 2)Large Missile Impact Test per FBC,TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of a PVC sliding-glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system,Duraseal®spacer system, Super Spacer®NXTTM spacer system and XL EdgeTM spacer system at insulated glass,prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11/16/15, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega,P.E. 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2)Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory,Inc., Test Report No. FTL-5330, dated 07/18/07, signed and sealed by Carlos S.Rionda,P.E. -- (Submitted under NOA No. 07-081 S.09) 3. Test reports on: 1)Air Infiltration Test,per FBC, TAS 202-94 2)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC, TAS 202-94 ..4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1,TAS 202-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc., Test Report No.FTL-4858, dated 03/08/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No.06-0405.06) Manuel Per .E. Product Control E er NOA No.16-0714.13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-1 I i s PGT Industries,Inc. K t NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (coNTINUED) 4. Test.reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 ..4)Large Missile Impact Test per FBC,TAS 201-94 5)Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC 2411.3.2.1, TAS 202-94 along with marked-up drawings and installation diagram of an XOX aluminum horizontal sliding window,prepared by Fenestration Testing Laboratory, Inc.,Test Report No.FTL-4859, dated 03/08/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under NOA No. 06-0405.06) C. CALCULATIONS 1. Anchor verification calculations and structural analysis,complying with FBC-51h Edition (2014),dated 05/14/15,prepared by manufacturer,signed and sealed by Anthony Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company(MA) for their"Sallex Clear and Color Glass Interlayers"dated 06/19/14, expiring on 05/21/16. 2. Notice of Acceptance No. 14-0916.10 issued to Kuraray America,Inc.for their "Kuraray Butacite®PVB GIass Interlayer"dated 04/25/15, expiring on 12/11/16. / Manuel PeIP4 Product Control Ekaminyr NOA No. 16- .13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-2 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBAUTTED y V•• F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5=h Edition (2014), dated May 16,2015,issued by manufacturer,signed and sealed by A. Lynn Miller, P.E. (Submitted under previous NOA No.15-0519.09) 2. Statement letter of no financial interest, dated May 16, 2015, issued by manufacturer, signed and sealed by A.Lynn Miller,P.E. (Submitted under previous NOA No. 15-0519.09) 3. Laboratory compliance letter for Test Report No:FTL-5330, issued by Fenestration Testing Laboratory, Inc., dated 07/18/07, signed and sealed by Carlos S. Rionda, P.E. (Submitted under NOA No. 07-0815.09) 4. Laboratory compliance letter for Test Reports No. FTL-4858 and FTL-4859, issued by Fenestration Testing Laboratory, Inc., dated 03/08/06, signed and sealed by Edmundo Largaespada,P.E. (Submitted under NOA No. 06-0405.06) 5. Proposal No. 16-0125 issued by the Product Control Section, dated March 09,2016, signed by Ishaq Chanda, P.E. G. OTHERS - 1. Notice of Acceptance No. 15-0519.09,issued to PGT Industries for their Series "HR-710"Aluminum Horizontal Rolling Window-L.M.I., approved on 07/09/15 and expiring on 12/21/21. ` Manuel Pere .! Product Control Exa ' r NOA No.16-0714.13 Expiration Date: December 21,2021 Approval Date: September 01,2016 E-3 GENERAL NOTES: IMPACT HORIZONTAL ROLLER FLANGED AND INTEGRAL FIN WINDOW STANDARDS USED: •2014 FLORIDA BUILDING CODE(FBC),STH EDITION 1.GLAZING OPTIONS:(SEE DETAILS ON SHEET 2).FOR INSTALLATION ABOVE 30 FT,GLASS TYPES G THRU L MUST HAVE A TEMPERED GLASS CAP. •ASTM E1300-09 •ANSI/AF&PA NDS•2012 FOR WOOD CONSTRUCTION A.5116'LAMI CONSISTING OF(2)LITES OF 1/8"ANNEALED GLASS WITH A.09D""PVB"INTERLAYER. •AL -810 DESIGN MANUAL,ADM-2010 •AISIS700-071S2-2010 B.5116'LAMI CONSISTING OF(1)LITE OF 1/8"ANNEALED GLASS AND(1)LITE OF V8"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. C.5/16"LAMI CONSISTING OF(2)LITES OF 1/8"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. D.7/16'LAMI CONSISTING OF(2)LITES OF 3116"ANNEALED GLASS WITH A.090""PVB"INTERLAYER. E.7/16"LAMI CONSISTING OF(1)LITE OF 3/16"ANNEALED GLASS AND(1)LITE OF 3/16"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. NOA DRAWING MAP F.7/16"LAMI CONSISTING OF(2)LITES OF 3/16"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. SHEET G.13/16"LAMI IG:(1)LITE OF 118"OR 3/16"ANNEALED(MIN.)GLASS,5116"OR 3/8'AIR SPACE AND 5116"LAMI GENERAL NOTES.............1 CONSISTING OF(2)LITES OF 1/8"ANNEALED GLASS WITH A.090""PVB"INTERLAYER. GLAZING DETAILS............2 DESIGN PRESSURES.......3 H.13116"LAMI IG:(1)LITE OF 1/8'OR 3/16"ANNEALED(MIN.)GLASS,5116'OR 3/8"AIR SPACE AND 5116"LAMI CONSISTING OF(1)LITE OF 1l8"ANNEALED GLASS AND(1)LITE ELEVATIONS.....................4 OF 1/8"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. VERT.SECTIONS.............5 HORIZ.SECTIONS............5 1.13116"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,5116"OR 3/8"AIR SPACE AND 5/16"LAMI PARTS LIST.......................6 CONSISTING OF(2)LITES OF 1/8"HEAT STRENGTHENED GLASS WITH A.090"'PVB"INTERLAYER. EXTRUSIONS....................7 CORNER DETAIL..............5 J.13116"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,3/16"OR 1/4"AIR SPACE AND 7/16"LAMI ANCHORAGE....................8-11 CONSISTING OF(2)LITES OF 3/16'ANNEALED GLASS WITH A.090""PVB"INTERLAYER. K.13/16"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,3/16"OR 1/4"AIR SPACE AND 716"LAMI CONSISTING OF(1)LITE OF 3/16"ANNEALED GLASS AND(1)LITE OF 3/16"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. L.13116"LAMI IG:(1)LITE OF 1/8"OR 3/16"ANNEALED(MIN.)GLASS,3/16"OR 1/4"AIR SPACE AND 7/16"LAMI CONSISTING OF(2)LITES OF 3/16"HEAT STRENGTHENED GLASS WITH A.090""PVB"INTERLAYER. 2.CONFIGURATIONS:OX,XO,XOX 3.DESIGN PRESSURES:(SEE TABLES,SHEET 3) A.NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300. B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300. 4.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 8 THROUGH 11 FOR ANCHORAGE DETAILS. 5.SHUTTERS ARE NOT REQUIRED. PRODUCT REVISED .rnmplyiog withth.Fb" BoBdmg Coda 6.FRAME AND PANEL CORNERS SEALED WITH NARROW JOINT SEALANT OR GASKET. Accepte,moI.b v-O Ex Imtion Dale� 2� 7.REFERENCES:TEST REPORTS FTL4858,FTL-4859 AND FTL-5330. B ELCO TEXTRON NOA'S y ANSIIAF&PA NDS FOR WOOD CONSTRUCTION Mioni eProdact ALUMINUM DESIGN MANUAL 8.THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ), ".7 y;diV t✓ !� 9.FOR INSTALLATION IN THE HVHZ ABOVE 30 FT,GLASS TYPES G-L SHALL HAVE A TEMPERED I.G.GLASS CAP,BOTH THE DP AND ANCHOR QUANTITY REMAIN UNCHANGED. ��;<+c-',�'; /!/�•' "PVB"=.090'BUTACITEQ PVB INTERLAYER BY KURARAY AMERICA,INC. � - rmrmey. JR o5'osr7B c ADDED SPA GENERAL NOTES ;.'�';.'••. ' J •'• '`�� 1070TECHNOLOGY DRIVE _ ..' `� ••.',COii1'`'C'',�;J••• N.VENICE,FL 34275 !IC T ALUM.HORIZONTAL ROLLER WINDOW,IMPACT J �',��t' E� c�,!.•`�'`� P.O.BOX 1629 —,fit B — ...v- p' !!+1 +1 �..o� caedaa t>ax NOKOMI5,FL 34274 Vlsibl�•Betfir d 11 4127-10 G A.LYN B.p60705 P P.E. RX 22&U6 J.J. 3113NB HR7f0 NT$ 1 111/2 50 21 50 Part# Description Material 75 Kommeding 4SG TPS Spacer System "NOM. 1/2"NOM. 76 Quanex Super Spacer nXT with Hot Melt ButylSee this LASS BITE 55 GLASS BITE Sheet for 77 Quanex Duraseal Spacer Materials 78 Cardinal XL EdgeSpacer 60,61,62 51 83,64,65 REFER C REPORTS:FTL-8717,8968 8 8970 18'ANNEALEDOR HEAT STRENGTHENED GLASS 3116'ANNEALED OR HEAT STRENGTHENED GLASS 090 PVB INTERIAYER 090 PVB INTERLAYER VS'ANNEALED OR HEAT STRENGTHENED GLASS- 3116'ANNEALED OR HEAT STRENGTHENED GLASS 6116'NDM. 7116'LAMINATED LAMINATED GLASS 7/16".LAMINATED GLASS FOR INSTALLATION IN THE HVHZ ABOVE 30 FT,GLASS TYPES G-L SHALL HAVE A 1 TEMPERED I.G.GLASS CAP. EXTERIOR INTERIOR _ BOTH THE DP AND ANCHOR (ALL SECTIONS) " �" QUANTITY TO REMAIN KPVBINT RLAYETE UNCHANGED. or PVBINTERLAYER P1 LBITE 13/16'ANNEALED 50 SAFLEXOPVBINTERLAYER BY EASTMAN CHEMICAL COMPANY 75-78 1 M'NOM. 59 G LASS BITE 52 7 72,73,74,75,76,77 A4-111- 118'ANNEALED OR HEAT STRENGTHENED GLASS OR HEAT STRENGTHENED GLASS090 PVB INTERLAYE290 PVB IN ERLAYER 118'ANNEALED OR HEAT STRENGTHENED GLASS116'ANNEALED OR HEAT STRENGTHENED GLASS 5116'LAMINATED7/16'LAMINATED 5116"OR 3f8'AIR SPACE /16'OR114'AIRSPACE W OR 3116'ANNEALED ORTEMPERED GLAS9 /8'or 3/16°ANNEALED OR TEMPERED GLASS 13116'NOM. 3/18'NOM, 13/16"LAMI IG GLASS W/5116"LAM[ 13/16"LAMI IG GLASS W/7/16'LAMI ALUMINUM SILICONE HOT-MELT BUT REINFORCEMENT p0LYISO- DESICCANT FILL AREA PRODUCT REVISED es cemplyiug with the Florid. STRUCTURAL BUTYLENE 5/16°NOM. 8116'NOM. Ampt g code STRUCTURAL SILICONE 3116"NOM. Ste• ACCGpgmee lVo POLYISOBUMEN 1/4'NOM. FOAM BUM& SILICONE SEAL fation Dam WITH DESICCANT WITH DESICCANT ROLL-FORMED / DESICCANT STAINLESS INLESS STEEL By EXT.GLASS EXT.GLASS EXT.GLASS Mhmm edeft°d°M EXT.GLASS INT.GLASS INT.GLASS INT.GLASS INT.GLASS •�;Qil P,itL(,!F��i, 76 KODISPACE 7e SUPER n DURASEALO 7e XL EDGE"' 0 4SG TPS O SPACERDNXT rm OSPACER OSPACER T.o,IO�t U6. tlul' .r JR Oti0SH8 O ADDED SPACERS. OT'•', .., GLAZING DETAILS :;::%, RLOF.. 1070 TECHNOLOGY DRIVE f.�• lam MSMY�c N.VENICE,FL 34275 C;— ALUM.HORIZONTAL ROLLER WINDOW,IMPACT !/ ;; ![ ;;;° ' P.O.BOX 152E /' t 1 N7 taLc acme ne NOKOMIS,FL 34274 VWbly Better FP27f0 FU�I 2 A LYf•1NI AiIIL��R P.E.aea>bel' evge FJL 211 W J.J. 323�8 1! 4127-l0 G P.E.ase7� I TABLE 1. XOX(114,112,114)FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS W/SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE 26" 136" 38 318" 48'. 50 5/8" 54" 60" 63" 84" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 i -60.0 +60.0 1 •60.0 +60.0 -60.0 +60.0 -60.0 +60.0 j -60.0 +60.0 1 -60.0 96" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 i •60.0 +60.0 -60.0 +58.8 -58.8 +56.2 ' -56.2 FOR INSTALLATION IN 106 318" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +55.2 -55.2 +52.3 -52.3 THE HVHZ ABOVE 30 108" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 -60.0 +60.0 •60.0 +60.0 -60.0 +60.0 -60.0 +54.6 -54.6 +51.7 I -51.7 FT GLASS TYPES G- L SHALL HAVE A 111" A,B,G,H +60.0 -60.0 +60.0 -60.0 +60.0 ! -60.0 1 +60.0 -60.0 +60.0 -60.0 +59.5 59.5 +53.6 1 -53.6 +50.9 1 -50.9 TEMPERED I.G.GLASS CAP.BOTH THE DP UP TO 111" C,I +60.0 1 -60.0 AND ANCHOR UP TO 111" D'E'F' QUANTITY REMAIN +75.0 -75.0 UNCHANGED. TABLE 2. XOX(113,113,113)FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS Wl SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE ALL HEIGHTS UP TO 83" TO 86 7/16" A'B'C' +60.0 -60.0 G,H,I TO 86 7116" D'K L +75.0 -75.0 TABLE 3. OX AND XO FLANGE OR INTEGRAL FIN WINDOWS(FLANGED SHOWN.FIN WINDOWS WI SAME DLO ARE 1"SMALLER) WINDOW GLASS WINDOW HEIGHT WIDTH TYPE 26" 36" 38 3/8" 48" 50 b/8" 54" 60" 03" 60" A,B,G,H +75.0 -76.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -76.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 66" A,B,G,H +75.0 -75.0 +75.0 -75.0 +75.0 75.0 +75.0 -75.0 +75.0 ; -76.0 +75.0 -75.0 +74.2 -74.2 +70.2 -70.2 72" A,B,G,H +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +69.6 -69.6 +65.2 -65.2 rs comply PROD uc gwiththo with thoREVISED Florida 74" A,B,G,H +75.0 75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +68.1 -68.1 +63.8 -63.8 nailai�ooae C D,E F, +75.0 -75.0 Accoplaneallo 1 -D I 1��1 rat Date �b UP TO 74" n I,J,K,L rvrao,; ePmdact GLASS TYP;&16A T REPORT FTL-4858(XOX),FTL-4859(OX&XO)AND FTL5330 A.5/16"LAM A,.090,1l8"A) G. 13/i6"LAMI IG 1/8"OR 3/16"A(MIN.),5/16"OR 3/S"AIR SPACE,5/16"LAMI-(1/8"A,.090,1/8"A)B.5/16"LAM "A,.090,1/8"HS) H. 13/16"LAMI IG-1/8"OR 3/16"A(MIN.),5/16"OR 318"AIR SPACE,5/16 LAMI-(1/8"A,.090,1/8"HS)C.5/16"LAM ' HS,.090,1/8'HS) I. 13/16"LAMI IG 1/8"OR 3/16"A(MIN.),5/16'OR 3/B"AIR SPACE,5/16"LAMI-(1/8"HS,.090,1/8"HS)D.7/16"LAM6"A,.090,3/16"A) J.13/16"LAMI IG-1/8"OR 3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A, .090,3/16"A)E.7/16"LAM6"A,.090,3/16"HS) K. 13/16"LAMIIG-1/8"OR3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"A,.090,3/16"HS)F.7/16"LAM "HS,.090,3/16"HS) L.13/16 LAMIIG 1/8"OR3/16"A(MIN.),3/16"OR 1/4"SPACE,7/16"LAMI-(3/16"HS,.090,3/16"HS)1D70TECHNOLOOY DRIVE - - DESIGN PRESSURESN.VENICeLOGY 275P.O,BO%1620 ALUM.HORIZONTAL ROLLER WINDOW,IMPACTOWs o� NOKOMIS.FL34274 Vidbly Berar A.LYP. MILLER P.E. F.K �8/aB . �e s.� NTS 3 d f1 ��4127-10 (j P.E#53705 27 318" 27 27 MAX.DLO 54 5116°MAX.DLO FIXED MAX.OLD DLO MAX.DLO VENT VENT FIXED D D 7-ki,•7t.��1' B B B B X O X — — — j-. 110"MAX.WIDTH I.F.FRAME—� 85 7/16"MAX.WIDTH I.F.FRAME—►� ---111"MAX.WIDTH FLANGE FRAME I �66 7/16"MAX.WIDTH FLANGE FRAME DETAIL B-XOX(1/4-1/2-1/4) DETAIL C-XOX(1/3-1/3-1/3) NOTE: 33 9116"MAX. 33 9116"MAX. 1.SEE SHEET 5 FOR VERTICAL AND HORIZONTAL SECTION DETAILS. DLO FIXED C DLO VENT •1 `I SEALANT OR GASKET `Nit spa , F AT HEAD AND SILL + A I A FRAME ALL 15 57 3/8" 56" CONFIG., / / MAX / / MAX, — PRODUCT REVISED DLO ALL DLO ALL 15 I.F.FRAME as complying wiNthe Florida FIXED VENTS 0ai1dmg cone /LITES 62"MAX. I.F.FRAME ration Deco O I X ALL ny CONFIG. p4,_OedePradoct' I 1 .•i,ullrttrrJ: . 13 FLANGE FRAME C r 73"MAX.WIDTH I.F.FRAME--� VIEW D—D 74"MAX.WIDTH FLANGE FRAME— -1 FRAME CORNER CONSTRUCTION — DETAIL A-OXORXO ( ) 'a'�'6 f"1 Ewa am P T ELEONS cfa 1070 TECHNOLOGY DRIVE VATI 'i,.C;�'•;, %�� N.VENICE,FL 34276 ns •'J ;*'t[,1';Y?�'.:`� P.O.BOX 1528 ALUM.HORIZONTAL ROLLER WINDOW,IMPACT lg yc NOKOMIS,FL 34274 Wilbly Better '""'" �" °� OiibpNi s..: A LYNN MILLER P•E. FK P/ W J•J. 32a XR710 NTS 4 a 11 4127-10 G P.E.05e705 INTERIOR 37 32 35 22 39 1 22 p � q 1s 2 EXTERIOR INTERIOR 13 21 MAX.VENT DLO MAX.FIXED DLO I MAX.VEXT DLO MAX.WIDTH(FLANGE FRAME) EXTERIOR 19 SECTION 13-13 17 (HORIZONTAL SECTION-XOX SHOWN WITH FLANGE FRAME) MAX. INTERIOR 35 32 37 H 17EIGHT 39 FLANGE FRAME MAX VENT DLO q 16 MAX. FIXED DLO MAX.FIXED DLO MAX.VENT DLO 43 I� MAX.WIDTH(I.F.FRAME) 21 EXTERIOR SECTION A-A (HORIZONTAL SECTION-OX SHOWN WITH INTEGRAL FIN FRAME) 24 8 22 21 41 kINTERIOR PRODUCT REVISED zs-mplyfog with the Florida Coll A P / -o Za21 12 24 $ EXTERIORa 'minaD 12 �y wmml ade ProdocY •,•Iir::r,. EXTERIOR INTERIOR 10 6 10 SECTION C-C 42 SILL HEAD (VERTICAL SECTION,FLANGE FRAME) (VERTICAL SECTION, I.F. FRAME) (VERTICAL SECTION, I.F.FRAME) aver. o.rs a 'SECTIONS ••'i•..•:,'<,��•,i::A- ••�•.:- P T SECTIONS • 1070 TECHNOLOGY ORNE ' N.VENICE,FL 34275 ; P.O.BOX 1529 ALUM.HORIZONTAL ROLLER WINDOW,IMPACT p.Yney. #Mc _pqp; NOKOMIS,FL34274 Visibly Better 6O1` awt �°� �' A LYNN M81ER P.E. F.)(. ?/2&W J.J. fUi7f0 1ff 5 d 11 4127-10 G P.E.#58705 II'EM V41O2 EV DESCRIPTION MAIL PGT# ITEM DWG# DESCRIPTION MATT PGI# 1 A FLANGE FRAMEHEAD 6063-T6 AL 612237 66 GLASS 13116"LAMI IGl/8"A .,3/8"AIR SPA 5/16'LAMI 1/8"A,.090 PVB,1/8"A2 SASH STOP STD.) ANTI LIFT CLIP) 6063-T5 AL 6127,44 67 13116"LAMI IGll8"A . 318"AIR SPA 5/16'LAMI(1/8"A..090 PVB,1/8"HS) 3 #8 X 3/4 PH.PAN HEAD 7834AA 68 13/16"LAMI IGl/8"A(MIN.),3/8"AIR SPACE',5/16"LAM](1/8"HS,.090 PVB,ll8"HS) 4 4053 SASH STOP COVER(SASH STOP) 6063-T5 AL 69 13/16"LAMI IG3/16"A(MIN.),5/16"AIR SPACE,5/16"LAMI(ll8"A,.090PVB,ll8"A) 6 4136 FLANGE FRAME SILL 6063-T6 AL 64136 70 13/16"LAMI IG3/16"A(MIN.),5/16'AIR SPACE,5/16"LAMI(ll8"A,.090 PVB,ll8"HS) 7 SILL ADAPTOR 6063 T6 AL 64137 71 13/16"LAMI IG3/16"A(MIN.),5/16"AIR SPACE,5116"LAMI(1/8"HS,.090 PVB,1/8"HS) 7 413 6063-T6 AL 6413 72 13/16"LAMI IGU8"A(MIN.),1/4"AIR SPA 7/16'LAMI 3/16"A .090 PVB,3/16"A 8 413 ROLLII TRACKADAPTOR 73 13/16"LAMI IGl/8"A IN. 1/4"AIR SPA 7/16'LAMI 3/16"A .090PVB,3/16"HS 10 71298 WEEP HOLE COVER POLYPROP. 71298 „ 12 1626 ADHESIVE OPEN CELL FOAM PAD 7PAD1626 74 13/16"LAMI IGll8"A(MIN), AIR SPACE,7l16"LAMI /16"HS,.090 PVB,3116"HS) 75 13/16"LAMI IG3/16"A IN),3/16"AIR SPACE,7/16"LAMI(3116"A,.090 PVB,3/161,A) 13 1 4002 1 A IFIANGEFRAME JAMB 6063-T6 AL 612225 76 13/16"LAMI IG3/16"A(MIN.),3/16"AIR SPACE,7/16"LAMI(3/16"A,.090 PVB,3/16"HS) 14 1 4134 1 IGAsKEr FDRMAINFRAME SILL JOINT 74134W/K 77 13/16"LAMI IG3/16"A(MM.,3/16"AIR SPACE,7116'LAMI(3/16"HS,.090 PVB,3/16'HS) 15 1 1155 1 1#8X L000 QUAD TIN.SMS 781P A 90 1014 ISCREENFRAME OR&VE . 3105-H14 AL 16 1 4110 1 G I SCREEN ADAPTOR 6063-T5 AL 6411OG 91 1630 SCREEN CORNER KEY W/RINGS POLYPROP. 17 1 4054 1 B IFDCEDMEEMGRAIL 6063HD-TEAL 64054A 92 1631 SCREEN CORNERKEYW/OUT RINGS POLYPROP. 19 1 4066 1 IWSTP.,.187 X 230,FIN SEAL 64066G 93 1073 SCREEN SPRING ST.ST. 21 4105 1 ISASH TOP&BOTTOM RAIL 6063-T5 AL 612240 94 1624 SCREEN SPLINE-.135 DIA,FOAM EM PVC 22 1683 W STP.,250 X.270 BACK,FIN SEAL 61683G 95 1635 SCREEN SPLINE-.135 DIA.HARD EM PVC 23 225-1 ROLLER HOUSING&GUIDE 42112HD % SCREEN CLOTH 24 226 BRASS ROLLER WHEE S BRASS 7BRWH12 29 4128 HORIZONTALROILER SASH TOP GUIDE POLYPROP, 44128N 32 4006 D SASH MEETINGRAIL 6063HS-T6 AL 64006 z.710 33 1235 WSTP.,.170X.270BACY,FIN SEAL 67S16G 35 1096 1 ISWEEPLATCH DIECAST 71096 36 1 1016 1 1#8X.625PH.FL.SMS 7858 37 1 4126 1 JSASHSIDERAIL 6063-T5 AL 641M 2.624 38 16B W STP.,.250 X.270 BACK,FIN SEAL 61683G 39 7070 BULB W EA1'HIItSTRIP.187 X 275 67070K F 2 40 LIFT RAIL COVER CAP 74078"C"L OR R 41 4139 I.F.FRAME HEAD 6063-TEAL 64139 I.F.FRAME HEAD 42 4140 U.FRAME SILL 6063-T6 AL 64140 41 #4139,6063-T6 43 4141 I.F.FRAMEJAMB 6063-TEAL 64141 50 GLAZINGSILICONE,DOW 899,995 OR UIVALENT PRODUCT REVISED 51 1224 VINYLGLAZINGBEADBULB CK 6TP247W,K w complying with the Florida Building Code 52 1225 VINYL GLAZINGBEAD BULB MW 6TP248K 2.784 Acceptance M0 I�-O 4y..��,• 53 4039 B GLAZINGBEAD-5116' 6063-TSAL 64039B pimtiDnDato 7L0z1 54 4044 B GLAZINGBEAD-5/16"W/GRILL K1T 6063-T5 AL 644703 L�F.062 3.162 By ! 55 4222 A GLAZING BEAD-7/16" 6063-T5 AL 64222 �' pal 56 985 C GLAZINGBEAD-7/16'W/GR11LKTT 6063TSAL 6985 0� 1.988 59 4067 GLAZINGBEAD-13116' 6063-T5AL 64067 60 GLASS 5/16 LAMI(1/B A .090PVB 1/B A) I.F.FRAME JAMB ..' 61 " 5/16"LAMI 1/8"A,.090PVB,1/8"HS #4141,6063-T6 62 5/16'LAMI 1/8"HS,.090 PVB,1/8"HS) IdU.&i;f:ri 63 7/16'LAMI 3/16'A .090 PVB 3/16'A 2.710 64 7/16"LAMI 3/16"A .090PVB 3/16"HS I.F.FRAME SILL V .f 65 7/16'LAMI(3/16"HS,.090PVB 3/16"HS 42 #4140,6063-TO '• ' �<.�.; P -�- 1::::•„''; 1070 TECHNOLOGY DRIVE LIST NE 1� /; ";•.1,IlY}"`,,• N.VENP.O.BQ, 129 ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 1529 a p tl1 py NOKOMIS,FL 34274 Virtb[y Beitr HR710 A LYP EN P.E. FJC 228 J.J. 313 aNS d1 774127-1 G 58705 174-, 062 1.187 040 738 3.152 (�1.443+� 1. 73Lil f 1 .062 P COVER :1173 .062 3.(90 O SAS#40 3 6063-TS 1E22 O FLANGE FRAME HEAD O FLANGE FRAME SILL O FRAME SILL ADAPTER TIC-2.784--{ #4102A,6063 } T6 #4136,6083T6 #4137,6063-T6 1.363 1 -�II•�—.062 � .062 7e 062 FLANGE FRAM E JAMB '061 #4002A,8083T6 �Fl4 I , SAS O 5H 063 606 � STOP OS HORIZ ROLLER 6 RACK 17 FIXED S BE6063HD-Ts ETING AIL #402 .062 2. 79 062 � 2. 26 050 3 1.187 .OB j ,678 {►1.349-� 1.081 Imo— 1.291� 1.096 SASH TOP&BOTTOM RAIL 32 SASH MTG.RAIL 37 SASH SIDE RAIL 53 GLAZING BEAD,5/16" FmonUCTgwJ[h d 21 av complY�g with the Florida #4133,6063T5 #4006D,6063HS-T6 #4126,6063T5 #4039B,6063T5 Duitding Cod" /� O / Acceptance No .•LIJG r 2x'reti�x�Uau 050 � 1 Miami NVdactC"ptrol� 6 .63 678 78 678 8 4hh 44�-050 050- .050 - ,•.I:t::1 ,.o9s-�+ —+I 1.096 —SIT ; 54 GLAZING BEAD,5/16" 55 GLAZING BEAD 7/16" 56 GLAZING BEAD,7/16" 59 GLAZING BEAD,13/16" _rl;,, #4044B,6063-T5 #4222A,6063T5 #985C,6083T5 #4067,6063T5 (USED W/GRILL KIT) (USED W/GRILL KIT) +c:.507::.`, aft Cc PT EXTRUSIONS 40, 0 TECHNOLOGY DRIVE ' N.VENICE,R34276 ;— ALUM.HORIZONTAL ROLLER WINDOW,IMPACT P.O.BOX 152a n�er. oee cewo pyc NOKOMIS,FL 34274 1/JsJbly Bcttrr °�bd� �` maK °s�O�' R" A LYNN MILLFJi,Ps F.K 212&W J.J. 823f06 H 7m H ff 7 w 11 4127-10 G P.EA 5570S 1