HomeMy WebLinkAboutRevisionOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # 2007-0465 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 308 Palm Breezes Drive Fort Pierce, FL 34945 DETAILED DESCRIPTION OF PROJECT REVISIONS: Revise Enegry Calc to correct ACH v Change from 4 to 7 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC1261228 BUSINESS NAME: Renar Builders LLC QUALIFIERS NAME: Glenn A Davis II ADDRESS: 3725 S East Ocean Blvd Suite 101 CITY: Stuart STATE: FL PHONE (DAYTIME): (772) 692-7800 OWNER/BUILDER INFORMATION: NAME: ADDRESS: ST. LUCIE CO CERT. #: ZIP: 34996 FAX: (772) 692-9155 CITY: STATE: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAMF- Michael C Anderson ADDRESS: 3725 S East Ocean Blvd Suite 101 CITY: Stuart PHONE (DAYTIME): (772) 692-7800 SLCCC: 9123109 Revised 06130117 ZIP: STATE: FL ZIP: 34996 FAX: (772) 692-9155 FORM R405-2017 Pfi R• �. I", " Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: This checklist A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (one page) and an input summary checklist that can be used for Held verification (usually four pages/may be greater). Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO for the Performance Method. ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report (usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report (usually one page) 6/26/2020 3:22:26 PM EnergyGaugeig) USA 6.0.04 (Rev. 1) - PlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY" CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RENAR BERMUDA 1674 Builder Name: RENAR HOMES Street: 308 PALM BREEZE DRIVE Permit Office: FT PIERCE City, State, Zip: FT PIERCE, FL, Permit Number: Jurisdiction: 661100 Owner: APONTE RESIDENCE County: St. Lucie (Florida Climate Zone 2 } Design Location: FL, Fort Pierce 1. New, construction or existing New (From Plans) 9. Wall Types (1736.0 sgft.) a. Concrete Block - Int Insul, Exterior Insulation Area R=4.2 1488.00 ft2 2. Single family or multiple family Single-family b. Frame - Wood, Adjacent R=11.0 248.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 3 d. NIA R= ft2 4. Number of Bedrooms 10_ Ceiling Types (1674.0 sgft.) Insulation Area 5. is this a worst case? No a. Under Attic (Vented) R=30.0 1674.00 ft2 6. Conditioned floor area above grade (ft2) 1674 b. N/A R= ft2 R= ft2 c. N/A Conditioned floor area below grade (ft2) 0 11 Ducts R ft2 7. Windows(231.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 131 a. U-Factor: Sgl, U=0.54 178.50 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency b. U-Factor: Sgl, U=0.61 53.33 ft2 a. Central Unit 34.2 SEER:14.50 SHGC: SHGC=0.23 c. U-Factor: N/A f12 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 33.8 HSPF:8.20 , SHGC: Area Weighted Average Overhang Depth: 4.045 ft. 14. Hot water systems Area Weighted Average SHGC: 0.245 a. Electric p� Ca 40 gallons 8. Floor Types (1674.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1674.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 54.54 PASS Glass/Floor Area: 0.138 Total Baseline Loads: 58.04 1 hereby certify that the plans and specifications covered by Review of the plans and jjir- STA3�, this calculation are in compliance with the Florida Energy specifications covered by this q- ��,,•. �_ , rs Code. calculation indicates compliance . ve a* with the Florida Energy Code. ,F�r'v:H"''- PREPARED BY: � Before construction is completed c�J } : �,; � Y ,. ` DATE: this building will be inspected for "" i,':! 3 compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. CCi3 with the Florida Energy C e. OWNER/AGENT: ---- BUILDING OFFICIAL: "- DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). . 6/26/2020 3:22 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 _ INPUT SUMMARY CHECKLIST REPORT Title: "RENAR BERMUDA 1674 Building Type: User Owner Name: APONTE RESIDENCE # of Units: 1 Builder Name: RENAR HOMES Permit Office: FT PIERCE Jurisdiction: 661100 Family Type: Single-family New/Existing: New (From Plans) Comment: PROJECT Bedrooms: 3 Conditioned Area: 1674 Total Stories: 1 Worst Case: No Rotate Angle: 270 Cross Ventilation: Whole House Fan: CLIMATE Address Type: Street Address Lot # 13 Block/Subdivision., MORNING SIDE PlatBook: Street: 308 PALM BREEZE DR County: St. Lucie City, State, Zip: FT PIERCE , FL, Design Temp Int Design Temp Heating Design Daily emp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1674 13392 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1674 13392 Yes 8 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 162 ft 0 1674 ft2 _r 0 0 1 HOOF Roof Gable Roof Rad Solar Absor. SA Emitt Tested Emitt Deck Tested Insul. Pitch (deg) # Type Materials Area Area Color Barr 1 Gable or shed Composition shingles 1813 ft2 348 ft2 Light N 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 1 Full attic Vented 150 1674 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1674 ft2 0.11 Wood 6/26/2020 3:22 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBG 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405--2017 INIOU I zu IVIRVIAKY c1,r1r-%0r®e_I0 I ME:r1%-1M I WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below r all STypepace a i 1 N=>W Exterior Concrete Block - Int Insul Main 4.2 38 10 380.0 ft2 0 0.3 0 2 E=>N Exterior Concrete Block - Int Insul Main 4.2 44 10 440.0 ft2 0 0.3 0 3 SE=>NE Exterior Concrete Block - Int Insul Main 4.2 5 10 50.0 ft2 0 0.3 0 _ 4 S=>E Exterior Concrete Block - Int Insul Main 4.2 12 10 120.0 ft' 0 O 0.3 0 5 SW=>SE Exterior Concrete Block - Int Insul Main 4.2 5 10 50.0 ft2 0 0.3 0 _ 6 W=>S Exterior Concrete Block - Int Insul Main 4.2 56 8 448.0 ft2 0 0 0.3 0 7 S=>E Garage Frame - Wood Main 11 20 8 160.0 ft2 0 0.5 0.3 0 8 W=>S Garage Frame - Wood Main 11 11 8 88.0 ft2 0 0.5 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>N Insulated Main None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to As Built rotated 270 de reel . Wail Overhang \j # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W 1 Metal Single (Tinted) Yes 0.61 0.23 N 53.3 ft2 12 ft 4 in Oft 1 in None None 2 N=>W 1 Metal Single (Tinted) Yes 0.54 0.25 N 30.0 ft2 1 ft 4 in 1 ft 0 in None None 3 E=>N 2 Metal Single (Tinted) Yes 0.54 0.25 N 30.0 ft' 1 ft 4 in 1 ft 0 in None None 4 S=>E 4 Metal Single (Tinted) Yes 0.54 0.25 N 6.0 ft2 8 ft 4 in 0 ft 3 in None None 5 SE=>NE 3 Metal Single (Tinted) Yes 0.54 0.25 N 24.0 ft2 1 ft 4 in 1 ft 0 in None None 6 S=>E 4 Metal Single (Tinted) Yes 0.54 0.25 N 24.0 ft2 1 ft 4 in 1 ft 0 in None None 7 SW=>SE 5 Metal Single (Tinted) Yes 0.54 0.25 N 24.0 ft2 1 ft 4 in 1 ft 0 in None None 8 W=>S 6 Metal Single (Tinted) Yes 0.54 0.25 N 22.5 fie 1 ft 4 in 1 ft 0 in None None 9 SW=>SE 5 Metal Single (Tinted) Yes 0.54 0.25 N 18.0 ft2 1 ft 4 in 1 ft 0 in None None GARAGE # FfoorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SEA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1562.4 85.77 161.31 .1233 7 6/26/2020 3:22 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Sing[ HSPF:8.2 33.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 14.534.2 kBtu/hr 1026 cfm 0.75 1 sys#1 HOT WATER SYSTEM i # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- — Return - -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic 6 131 ft2 Attic 54 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin jj jj Jan [[ I� Feb [[ ]] Mar Heating [X] Jan (Xj Feb IX] Mar E j Apr ] AAppr u May Jun ] Jul u Ma Jun �}Cj Ju! Mug Se j Sep [ Oct Oct Nov Nov Dec XDec Ventin [[ JJ Jan [[ ii Feb IIXXI Mar IX] r Ma Jun j Ju1 E 3 E _ ( Se [X 3 Oct Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1- Electric Heat Pum 0%u 1- Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/s .ft. 0 ft2 0 ft 0.3 Main 6/26/2020 3:22 PM EnergyGauge42) USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6,0 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 6.0 Garage 3. No. of units (f multiple -family) 3. 1 4_ Number of bedrooms 4. 3 13. Cooling system: Capacity 34.2 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1674 d) Room unit/PTAC EER e) Other 14.5 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.556. b) Solar Heat Gain Coefficient (SHGC) 7b. 0.245 c) Area 7c. 231.8 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (insulation R-value) 2. Masonry (Insulation R-value) B_ Adjacent: 1. Wood frame (insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.2 111 11.0 10132. 11 a. 30.0 11 b. 11 c. 11 d. No 14. Heating system: Capacity 33.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 8.20 15. Water heating system a) Electric resistance EF 0.92 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatReC% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 308 PALM BREEZE DRIVE City/FL Zip: FT PIERCE FL 6/26/2020 3:22:29 PM EnergyGauge(D USA 6.0.04 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Florida wilding Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential: Performance, Prescriptive and ER.I Methods ADDRESS: 308 PALM BREEZE DRIVE Permit Number: FT PIERCE, FL, MANDATORY REQUIREMENTS See individual code sections for full details. F- R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ® R402.4.1 Building thermal enveldj5he building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ® R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed In Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNETIICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. ®R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.21A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 6/26/2020 3:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel -burning appliances. in Climate Zones 3 through 8, where open combustion air ducts provide combustion air to Ej open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated appliances, inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall e i fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through oonditioned space to a minimum of R-8. Exceptions; ipes installed continuous to the outside. 1. Direct vent appliances with both intake and exhaust p 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ®R402.4.5 Recessed fighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not luminairesmore than 2.0 shall be( sealed with a gasket or caulk between hin accordance e housing and the interior wall orPceillingssure cove covering. All recessed SECTION R403 SYSTEMS R403.1 Controls. ED R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. © R403.3.2 Sealing (Mandatory) Ali ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/1CC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (9) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. ® R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. Q R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report, of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory), Mechanical system piping capable of carrying fluids above 105'F (41°C) LJ or below 55°F (13'C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. ® R403.6A.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5A.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input' o the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 6/2612020 122 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ®R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). ® R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140'F (38°C to 60°0). ® R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be tumed off. R403.6.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. ❑ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1 _ Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. O R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3- If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of RA 9, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 drn/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room I 90 2.8 cfm/watt Any For Sl: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916 6f26f2024 3:22 PM EnergyGaugeO USA 6.0.02 (Rev.1) - FIsRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS _ (Continued) ElR403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. e and shale not be used for equipment sizing. Manufacturers The published value forAHRi total capacity is a nominal, rating -test valu expanded performance data shall be used to select cooling -only equipment. This selection shah be based on the outdoor design dry. -bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is Tess than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and seated by aFlorida-registered engineer, in attached single- and multiple -family units, the capacity o equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. �-] R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section ven if L R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load e the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ® R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. El intermittent Residences requiring excess cooling or heating equipment capacity on an R403.7.1.3 Extra capacity required for special intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections Cl 0403 and C404 of the iECC---Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or extemai to and within 3 feet (914 mm) of the heater, Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule !—f shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health Standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heats or computedother over reran arda operation means shalon, i from site-recovered energy, such as from a heat pump or solar energy R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ® efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSi Z 21.56, pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 6/26/2020 3:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 Rovo.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum Cop of 4.0 when tested in accordance 0 with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatorfihe energy consumption of electric -powered portable spas shail be controlled by the requirements ofAPSP-14. SECTION R404 ELECTRICAL. POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be F J high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. Ener Gaugeq) USA 6.0.02 (Rev. 1) - FlaRes2017 FSC 6th Edition (2017) Compliant Software page 5 of 5 612612020 3:22 PM 9Y TABLE f_ i &IT, BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RENAR BERMUDA 1674 Builder Name: RENAR HOMES Street: 308 PALM BREEZE DRIVE Permit Office: FT PIERCE City, State, Zip: FT PIERCE, FL , Permit Number. j Owner. APONTE RESIDENCE Jurisdiction: 661100 W Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as, Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Showedtub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. It, auumvir, i{ioNcvuutI VT ivg waus snau oe In accordance wan the provisions of lcc-4uu. 6/26/2020 3:22 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Builder: RENAR HOMES Community: Address: 308 PALM BREEZE DRIVE City: FT PIERCE State: FL x 60 13392 = CFM(50) Building Volume ACH(50) 1-1 PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Lot: NA Method for calculating build i 2 volume: O Retrieved from architectural plans Code software calculated O Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of rest: Printed Name of Tester: License/Certification #: Issuing Authority: 6/26i2020 3:22:31 PM EnergyGauge(D USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Renar Homes Bermuda 9 674 HVAC Load Calculations for Renar Homes , Prepared By: Preferred Air Conditioning & Mechanical 1643 Donna Road West Palm Beach, Fl. 33409 561-689-1093 Wednesday, August 28, 2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Elite Software Development, Jnc. 'Renar Homes Bermuda 1674 fi1ng4 Mee | ort ~ _ _^_-_' General Project Title: Renar Homes Bermuda 1674 Designed By: Preferred Air Cinditioning & Mechanical Project Date: 07-5-2019 1 Client Name: Company Name: manarnvn*s ` Preferred Air Conditioning & Mechanical Company Address: 1G43Donna Road Company City: West Palm Beach, F|.334O0 Company Phone: 561'689-1083 Company E-Mai|Address: i CompanyVVobsda: GETCOLD.MET | Reference City: Fort Pierce, Florida Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Dry Bulb Difference VVinV*c 42 394 n/a n/a 70 u/a Summer: 90 78 5996 6096 75 61 ! Total Building Supply CFM: 977 Per Square ft.: i 0.622 square ft. of Room Area.- 1,572 uare ft. Per Ton: 613 Building LQads'..: Total Heating Required Including Ventilation Air 25,64U E3tun Total Sensible Gain: Total Cooling Required Including Ventilation Air.- 30,792 Btuh 2.57 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. August VVedn�sdey, 8ugu Rhvae - Residential & Light UO mer i 1, HYAC. Loads Eute Software Development' C, Renar Homes Bermuda 16 Preferred Air Conditioning MeO. Pa e4 l West Palm BeAcH, Cooling System Type: �rS�n���Pump outdoor Model: OH14NBO36`0**B° Indoor Model: F64CNP042L CARRIER AIR CONDITIONING Tnadename: Outdoor Manufacturer: CARRIER AIR CONDITIONING Description: Air Source Heat Pump AMR|Reference No.: 0102515 Capacity: 34.200 Efficiency: 14.6SEER Heating System Type: Air Source Heat Model:CH14NB03S°0°°8° Tradenamo CARRIER AIR CONDITIONING Manufacturer: CARRIER AIR CONDITIONING Description: Air Source Heat Pump Capacity: .8UO Efficiency: 8.2H8PF This ayetem'sequipment was selected (naccordance with AC{AJManual S. 75� 8\�H�5O9& VV|O8�7OF Sen. gain: K8mnuo>8equipment sizing da��: SOO8-Q8F,SUV�8:7GF.VVOD8:4ZF.0 � . � . � . � 203088tuh batgain: 14O4B8tuh.Sen. loss: 30.725Bt h.Enhahngdg.moi|DB:78.1F.Entehngdg.00i|VV8:G59F. Entering htg. coil D13: 51.21F, CIg. coil TD: 20F, Htg- coil TD: 70F, Req. c1g. airflow: 1119 CFM, Req- htg. aiellow: 314 CFkA c,\—\FZswAR8URNUDA1G74rhQ Wednesday, August 28,2019\ 10:18AN FR�i—vao- Residential & Light -Commercial HVA.C1, Loads ... ... Elite Softvvare Development, Inc' Preferred Air Conditioningi.& Me ch Renar Homes Bermuda 1674 Pa e3 Room or Min fmuml Maximum! Rough.! Desig n J sps Duct,: Ducti Htg Cig Act. Duct Duct Name 1 Factori U1 00 Losst Velocity! Length! Flow Flow.._ -Flow Size !System 1 Supply Runouts; Zone 1 146.6 16 Other Ducts in System I Summary !System I !—Cooling Flow., 1119 j C:\...\RENAR8URMUOA1874rhQ VVedneaday, August 28.2U19.1(l1OAM