HomeMy WebLinkAboutElectrical shop drawings$GFCI
VP
VPVPVP $$GFCI
GFCI
LOCATION OF WORK
GENERAL NOTES
PIT - 1ST FLOOR
MACHINE ROOM -1ST FLOOR
DRAWINGS ARE PROVIDED TO
REFERENCE LOCATIONS OF WORK
SITES AND SURROUNDING AREAS. ALL
MEASUREMENTS AND DISTANCES
MUST BE VERIFIED AT THE WORK SITE.
#
NOTE
CONSTRUCTION NOTES
KEY PLAN
G E N E R A L E L E C T R I C A L N O T E
PLANS SUBMITTED FOR REVIEW
AFTER DECEMBER 31, 2017 ARE
DESIGNED IN ACCORDANCE WITH
THE 2014 NATIONAL ELECTRICAL
CODE.
DRAWING SCALE
PROJECT NO.
DRAWING NO.
SHEET OF
DATEDRAWN BY
T H I S D O C U M E N T C O N T A I N S
I N F O R M A T I O N T H A T C A N N O T B E
R E P R O D U C E D O R D I V U L G E D , I N
W H O L E O R I N P A R T , W I T H O U T
W R I T T E N A U T H O R I Z A T I O N F R O M
N I C H O L S C O N T R A C T I N G , I N C .
3 0 1 -9 2 4 -5 2 5 8
FREDERICK NICHOLS - CGC1522915
GREGORY JOHN GRESETH - EC13009689
GREGORY JOHN GRESETH - CAC1820514
5 0 8 O L N E Y S A N D Y S P R I N G R O A D
S U I T E #2 0 0
S A N D Y S P R I N G , M D 2 0 8 6 0
PHONE:3 0 1 -9 2 4 -5 2 5 8
FAX:3 0 1 -9 2 4 -5 2 4 5
W W W .N I C H O L S C O N T R A C T I N G .C O M
JMoñizaCONTRACT LICENSE INFORMATIONSHEET C O N T E N T
NO.BY REVISION DATE
1
2
3
2 13456
2 13456
C
D
B
A
C
D
B
A
ANSI E[SaQG C (11.00 X 17.00 IQcKHV)
APPLICABLE BUILDING CODESAPPLICABLE BUILDING CODES
GENERAL NOTES
01-20-20216 7/9/2020
ISLAND CREST CONDOMINIUM
1 OF 1
E1
MACHINE ROOM
FBC, NFPA 101, NFPA 70
HOISTWAY
3/8" = 1'
SCALE
1 MACHINE ROOM - ROOF LEVEL
3/8" = 1'
ISLAND CREST CONDOMINIUM
10680 S. OCEAN DR
JENSEN BEACH, FL 34957
1.NO STRUCTURAL WORK, DESIGN CHANGES, OR ADDITIONS ARE PERFORMED UNDER THIS
PERMIT THEREFORE ARCHITECTURAL DRAWINGS ARE NOT PROVIDED OR REQUIRED.
a.ALL NEW WORK AND EXISTING CONSTRUCTION ARE CLEARLY IDENTIFY. DRAWINGS
ARE OF SUFFICIENT CLARITY AND QUALITY TO EFFECTIVELY CONVEY THE NATURE AND
SCOPE OF THE PROPOSED WORK.
b.THE CLASS OF REHAB IS “RENOVATION” PER CHAPTER 43, SECTION 43.4… “THE
REPLACEMENT IN KIND, STRENGTHENING OR UPGRADING OF BUILDING ELEMENTS,
MATERIALS, EQUIPMENT OR FIXTURES THAT DOES NOT RESULT IN THE
RECONFIGURATION OF THE BUILDING SPACES WITHIN”.
c.WORK UNDER THIS PERMIT MEETS THE DEFINITION FROM FBC, EXISTING AS
“ALTERATION - LEVEL 1” AND IS COVERED BY THE PROVISIONS OF CHAPTER 7. IAW
CHAPTER 7, THE “ALTERATIONS” MADE BY THIS PERMIT MEET THE STANDARDS OF
CONFORMANCE FOR ALL AREA WORK.
3.NO NEW DESIGN FEATURES OR ENGINEERING CHANGES ARE MADE UNDER THIS PERMIT.
MECHANICAL AND ELECTRICAL DRAWINGS ARE BASED SOLELY ON THE SCOPE OF THE
WORK TO BE PERFORMED; ALL WORK IS DIRECT REPLACEMENT OF EXISTING COMPONENTS.
4.ELECTRICAL CIRCUITS FOR THE ELEVATOR CAB LIGHTING, PIT LIGHTING, MACHINE ROOM
(MR) LIGHTING AND MR GFCI CIRCUITS ARE ALL PRE-EXISTING CIRCUITS VERIFIED TO BE
POWERED FROM SEPARATE SOURCES. REPLACEMENT OF THESE COMPONENTS AND
FIXTURE ARE ALL DIRECT REPLACEMENT OF EXISTING EQUIPMENT; THE ONLY NEW
CIRCUITS ADDED IS MACHINE ROOM AC GFCI.
10680 S. OCEAN DR
JENSEN BEACH, FL 34957
1.DIRECT REPLACEMENT OF ELEVATOR
MAIN LINE DISCONNECTS.
2.DIRECT REPLACEMENT OF ALL
NECESSARY LOAD SIDE CONDUIT
AND WIRE FROM THE MAIN LINE
POWER AND CAB LIGHT
DISCONNECTS TO THE NEW
ELEVATOR CONTROLLER.
3.DIRECT REPLACEMENT OF LIGHT
FIXTURES IN THE ELEVATOR MACHINE
ROOM.
4.DIRECT REPLACEMENT OF EXISTING
NON-GFCI OUTLET WITH GFCI
RECEPTACLE IN THE ELEVATOR
MACHINE ROOM.
5.DIRECT REPLACEMENT OF LIGHT
FIXTURES IN THE ELEVATOR PITS.
6.DIRECT REPLACEMENT OF EXISTING
NON-GFCI OUTLET WITH GFCI
RECEPTACLE IN THE ELEVATOR PITS.
CONTROLLER
2
CONTROLLER
1
ML
ML
CL
CL
RETAIN
SCALE
2 ELEVATOR PITS - 1ST FLOOR
3/8" = 1'
1
1
2
3
3
3
4
5
5
6
6
MACHINE
2
MACHINE
1
LOBBY