HomeMy WebLinkAboutAPPROVED WINDOW AND DOOR SCHEDULEA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone - 10% of least horizontal dimension or 40% of the mean roof height, whichever is smaller, but not less than 4% of least horizontal dimension or 3 ft. OPENING LOCATION NUMBER (Location) Corner Zone or Interior IS THIS A WINDOW OR DOOR GLAZING TYPE PRODUCT ACCEPTANCE NUMBER PRODUCT APPROVAL APPROVED PRESSURE RATING REQUIRED OPENING DESIGN PRESSURE MAXIMU M TESTED SIZE ROUGH OPENING DIMENSIONS MULTIPLE WINDOW ARE SHUTTERS REQ Y/N + ( ) PSF (-) PSF (+) PSF (-) PSF MULLION REQ Y/N/NA 1 Int Door I" Lami IG FL20470.9 50 50 34.3 -37.5 74 X 81 74x80 No No 2 Int Window V Lami IG FL13010.4 55 55 37.0 -40.2 48 X 72 63x31 No No 3 End Window I° Lami IG FL13010.4 55 55 37.8 -50.6 48 X 72 36x17 YES No 4 End Window 7/8"La"'"G FL16177.1 70 70 37.4 -49.8 52 x 62 36x47 YES No 5 Int Window I° Lami IG FL13010.4 55 55 37.7 -40.9 48 X 77 25x61 No No 6 Int Window I° Lami IG FL13010.4 55 55 37.8 -41.0 48 X 72 36x17 YES No 7 Int Window 7/8Lami IG FL16177.1 70 70 36.8 -40.0 52 x 62 36x60 YES No 8 Int Window I° Lami IG FL13010.4 55 55 37.7 -40.9 48 X 72 25x61 No No