HomeMy WebLinkAboutAPPROVED Extreme Metal 5V Product ApprovalBCIS Home ; Login ) User Registration j Hot Topics Submit Surcharge Stats & Facts
d p Florida
Product Approval
r - USER: Public User
ProductApproval Menu > Product or Application Search > Application List > Application Detail
FL #
FL17022-R8
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
i
Publications I Contact Us I BCIS Site Map I Links I Search i
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17022 R8 COI 269a VMAX piywoo .pdf
Standard
TAS 100
TAS 125
UL 580
Year
1995
2003
2006
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/05/2020
Date Validated
10/12/2020
Date Pending FBC Approval
10/25/2020
Date Approved
12/15/2020
Date Revised
12/16/2020
Summary of Products
FL #
Model, Number or Name
Description
17022.1
01: 26ga VMax on Plywood
26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R8 II 26ga VMAX ply _god.odf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-228
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R8 AE 26ga VMAX plywoo pdf
Created by Independent Third Party: Yes
17022.2
02: 032 Aluminum VMax on Plywood
Nominally 0.032" aluminum (or thicker) VMax 5V panel with
21" coverage on 15/32" (min) plywood or 3/4" (min) thick
j wood plank.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17022 R8 II 032 VMAX 21in pLywood•p�f
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure:
+N/A/-168.5 Evaluation Reports
Other: Refer to evaluation report. I FL17022 R8 AE 032 VMAX 21in plywood.pdf
Created by Independent Third Party: Yes
17022.3 03: 26ga VMax on Plywood 1 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and in the ribs.
Limits of Use Installation Instructions
Approved for use in HVHZ: No I FL17022 R8 II 26ga VMAX plywood flats.p�
Approved for use outside HVHZ: Yes ! Verified By: David Eng, PE 81377
Impact Resistant: N/A j Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.25 Evaluation Reports
Other: Refer to evaluation report. FL17022 R8 AE 26ga VMAX plywood flats.psif
Created by Independent Third Party: Yes
17022.4 04: 26ga CorMax on Plywood
26ga (min) CorMax corrugated panel with 29.5" coverage on
i
15/32" (min) plywood or 3/4" (min) thick wood plank.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL17022 R8 II 26ga CorMax Plywood HVHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R8 AE 26ga CorMax Plywood HVHZ,pd
Created by Independent Third Party: Yes
17022.5 ( 05: 26ga CorMax on Battens
26ga (min) CorMax corrugated panel with 29.5" coverage on
_
2x4 (min) battens,
Limits of Use
Installation Instructions e
Approved for use in HVHZ: No
FL17022 R8 II 26ga CorMax Battens.odf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: NIA
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R8 AE 26ga CorMax Battens.odf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(t),
ejes
Paco 1!Paj:D
cs3da33y lenoaddtl :pnPad
j:)lp aseald '•s A 'Ssb aaadeyo aapun easuaoll a aae noA p aulweaiap oy •oiignd ayl of aigepene apew aq ueo goiym ssaippe pews ue q;im 4uaw:pedao aq4 apinad
aseald 'ssauppe leumad a Aiddns oa gsinn 4ou op no/, dI piooai olIgnd We sassaJppe pews uanamoH •easua3il aq4 pim uopeolunwwoo lelol4o uoj pass aq hew papinad
sgewe ayl •auo aneq Aaya;i ssaippe pma ue glim 4uawljedao 044 apinoid asnw S'd 'SSb jaadey:) japun pasuaall saasuaoll 'ZTOZ IT jagoxoo anlPa}}a 'sa;nae;s epaoij
......oJS�,%.
hit jo 3 LVJ-S w�t�
`0030+M90:00
EL8 'oN a0-0G�0Z0Z
GL— T
6u3 3 Pineo
J �
11111
ua00•an0:)9>!5-!J9gw!1•MMM
tit,£££ VZ) 1d I LL£I8 3d 1d
1d all!nsaulDo 190Z# any nlun M tiZ££
Z)-j-') `ano' a� DI-49qua!1
3d `5u3 pinOa
:Aq pa.� Dn I on3
(Z•b'O 40 '9'S UILU) >IuDId pooh >lol44. (uiLu) «*,/£
Jo poomAld (ulw) KZ£/Si
>joaC]/a.I aJ.�sgnS
•paJ!nbaJ aJayM 9.90SI :)9d u.�!M ..uo!!duao:)
J94SOM SUIIoaS 440m JOU94.SO.. KCu'i X Oi# JO 6#
Jauaa.so3
pe.a!nbaJ aJayM E-t-LOSI :)9.3 Jad �uD.4sisaj uo!soJJoo
1;994s (ulw) DBgZ
IniJa.�OW �onpoJd
'«8/E 30 44Fiay q!J
Iouluaou pua, 96gJ9AOO xOUJ ,tZ 44!M !auDd f9ua4sD4 pasodxa 91Ats clua!JO AS
uoi�diJosa(3 4onpoJd
066VE '1d A-�!:) wlpd I JQ Owod MS OZTZ
sJo.�oopgq-j (p-�aW au 9-1-�X3
pooMAId (u i W) ,Z£/SZ aano XVWA (u i ua) g69Z
5W3tSAS 9lVzj00d 7V13W 30 Sd3 -dVHJ 0377XNS
suoido=aadi
1d.L3w3w3zd.LX3
N
� d
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re -Roofing: This panel may be instal►ed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Method A: #9 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 86 PSF
Method B: #10 x 1.5" fastener in 12"-12" pattern at 16" o.c.: 93.5 PSF
Method C: #10 x 1.5" fastener in 12"-12" pattern at 8" o.c.: 101 PSF
Method D: #10 x 1.5" fastener in 12"-12"pattern at 6" o.c.: 228 PSF
A factor of safety of 2 has been applied.
Technical Documentation:
This product has been tested to the UL 580 standard by Architectural Testing (now Intertek
Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in
FL 17022.01-R7
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A: METHOD B: METHOD C:
#9 AT 16" O.C. #10 AT 16" O.C. #10 AT 8" O.0
J
Ja
i
a
,: 10%OF LEAST HOIZONTAL DIMENSION OR 0 4 . WHICHEVER IS SMALLER, BUT NOT
LESS THAN EITHER 4%OF LEAST HORIZONTAL DIMENSION OR 0FT (O.SM).
OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE.
ROOF ZONES FOR GENERIC BUILDING
METHOD D:
#10 AT 6" O.C.
C-12" (NOM) 12" (NOM)—1 NR: NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26
a 5V Crimp
on 15/32" plywood
FL17022.01: 26cia
5V Crimp on 15/32" 121vwood
Wind 105 110
120
130
140
150
160 170 180 190 200
Wind 105 110
120 130 140 150 160 170 180 190 200
Zone 1: A A
A
A
A
A
A A A A A
Zone 1: A A
A
A A A A C'
Zone 2: A A
A
A
A
A
A A C
Zone 2: A A
A
A C n
Zone 3: A A
A
A
A
A
B C'
Zone 3: A A
A
C
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7", hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less