HomeMy WebLinkAboutConcrete Pad InfoPI: r[;`' II APR iail ]\ ` GENERATOR O I PAD THICKNESS PAD DIMENSIONS: CONCRETE PM GENERATOR GENERATOR UNIT BY o SEPARATE SUBMITTAL (SEE SCHEDULE FOR n I MINIMUM WEIGHT REQUIRED) -- 54" LENGTH PLAN VIEW AMr--RICAST GENERATOR CONCRETE P ".D F�L� �O 4rorti (ON -GRADE APPLICATIONS ONLY) WIND DESIGN REQUIREMENTS ry AMERICAST NnWy,l+it®61To mn •NAD3E 12 AM&R1GI• FEO TAXp 921'imoto Ave.LI Pie=% R. 34N250163 5303 Polmnlo vPon Pierta F. 36982 Tel.112=11 9se Pee: n3J66-0So9 ems: ww.c....=a..m..�.. a..�wm36A.boo.. HVHZ OR NON-HVHZ COUNTY RISK EXPOSURE EXP) RISK EXPOS URE(EXP RISK EXPOSURE EXP I C D II C z D;',. - III, IV C D P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47A4 Psf 180 MPH 43.83 Psf 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 P.sT -180'MPH 43.83 PSP 53,19 Psf MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 1186 MPH 146.80 Psf 156.80 Psf ISOMETRIC VIEW CONCRETE PAD ROAD MESH ASTERFIBER 3" MIN MAC100 --,F-4" MIN GENERATOR TABLE: BRAND & MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.00 i 48.00" 29.00" 387 lbs 54.00 Psf EXP C 186 MPH & D 180 MPH Generac 005872 & 005884 14 KW 25.00 48.00" 29.00" 439lbs 56.80 Psf UP TO EXPOSURE D 186 MPH Generac 6459,6461,6462 16 KW 25.06 48.00" 29.00" 513 lbs 56.80 Psf GenencOO6721 16 KW 25.00" 48.00" 29.00" 448lbs 56.80 Psf Generac 005873 & 005885 17 KW 25.00" 48.00" 29.00" 455lbs 56.80 Psf Generac 005874 & 005886 17 KW 25.00" 48.00" 29.00" 4211bs 56.80 Psf Generac 005875 & 005887 20 KW 1 25.00" 48.00" ' 29.00" 451 lbs 56.B0 Psf Generac 006729 & 006730 20 KW 25.00" 48.00" 29.00" 516lbs 56.80 Psf to Generac 006551 & 006552 22 KW 25.00" 48.00" 29.00" 526lbs 56.80 Kohler 14RES&20RES 14.20 KW 26.00" 48.00" 29.00" 500lbs 56.80 Psf GE 40323GE & 40324GE 13 KW 35.00" 39AO " 39.00" 540lbs 49.50 Psf EXP C 186 MPH & D 170 MPH GE 04038215KW 15 KW 33.00" 48.00" 30.50" 484 lbs 1 56.80 Psf UP TO EXPOSURE D 186 MPH GE 04037817KW GE 40330GE & 40331GE 17 KW 20 KW 33.00" 33,00" 48.00" 48.OD" 30.50" 30.50" 484lbs 600lbs 56.80 Psf 56.80 Psi Briggs & Stratton 040243-0 10 KW 31.00" 32.00" 34.00" 430 lbs 56.80 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00" 31.60" 507 lbs 54.00 Psf EXP C 186 MPH & D 180 MPH Brlggs&Stratton 040303-1 15 KW 33.75" 49.00" 31.60" 562 lbs 56.80 Psf UPTO EXPOSURE D 186 MPH Briggs& Stratton 040304.1 18 KW 33.75" 49.00" 31.60" 568lbs 56.80 Psf Brlggs & Stratton D403OS-1 20 KW 33.75 " 49.00" 31.60 " 570lbs 56.80 Psf 16 KW 25.00 " 48.00 " 29.00 " 406 lbs 47.44 Psf EXP C 186 MPH & D 170 MPH tGenerac 007038 & 007039 20 KW 25.00" 48.00" 29.00 " 448lbs 47.44 Psf rierac007042&7043 22 KW 25.00" 48.00" 29.00" 4661bs 47.44 Psf GENERATOR MOUNTING CONFIGURATION: TGENEI�1� 0 I I I (SEE CONCRETE PAD SCHEDULE FOR = I = II DIMENSIONS & WEIGHT REQUIRE4° I � I 7-32" WIDTH ---� }-54" LENGTH SIDE NEW FRONT VIEW GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING TO GENEW (SEE GENERATOR SP THICK GALVANIZED WASHER& RUBBER VIBRATION PAD (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH ED N (2014)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult - 186 mph NOMINAL DESIGN WIND SPEED Vasd - 144 mph RISK CATEGORY - III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/R2 FORCE COEFFICIENT Cf = 1.44 WIND PRESSURE: P = qh G Of = 56.80 Ib/ft2 (ASD) ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE, 6' MIN. SPACING TO ANY ADJACENT ANCHOR NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE "EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS: NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. 5. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS 3V SIMPSON TITEN HI SEE ANCHOR SCHEDUL 2"x3"x3/b" GALV. STEEL WASHER RUBBER VIBRATION PAD �- CONCRETE PAD - 6,000 PSI LIGHTWEIGHT CONCRETE PAD X CONCRETE MIX 6,000 PSI LIGHTWEIGHT MASTERFIBER MAC 100 J CONCRETE MIX & ROAD MESH NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS t- 2" -t GENERAL NOTES 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE (Sth EDITION). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A 308-SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. S. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. 6. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. 7. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. 8. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATERTIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 11. THIS DOCUMENT 15 GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS, ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY `v VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. l.J 0 N rZ LU M s LL® -h "'$O rr303 N W VJ i thJ ' o' a ZUl O imt2cW Lga g<uj Z X_ zc IIJW O, �w� ISO"Ze 3 V E 2 0 V)d dwz W w •i Cl Nr I/1 Q LL m Q O w C U W n fNf QO IL Q F• N K J 0 ". Q N ds ID I3 dS IL W S M"$ S ' z N y c' 4 Bap � W Q m FF O Q ' r O W Ijl LL 3 1 17-3961.1 b w U' PAD THICKNESS AMERICAST GENERATOR CONCRETE PAD (ON -GRADE APPLICATIONS ONLY) AMERICAS ■ HVHZ OR NON-HVHZ COUNTY RISK EXPOSURE (EXP) I RISKr EXPOSURE (EXP RISK E%POSURE (EXP) I C I D 1 II 1 C I D IIII, IV I D P. BEACH 150 MPH 30.44 Psf I 36.94 Psf 170 MPH }9.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47:44 Psf 180 MPH 43.83 Psf 53.19 Psf MIAMI-DADS 165 MPH 136.83 Psf 144.69 Psf 1175 MPH 141.43 Psf 150.28 Psf 1186 MPH 146.80 Psf 156.80 Psf ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENERATOR x GENERATOR UNIT BY o SEPARATE SUBMITTAL (SEE SCHEDULE FOR ry MINIMUM WEIGHT REQUIRED) 54" LENGTH -� PLAN VIEW CONCRETE PAD ROAD MESH MASTERFIBER 3 MIN MAC300 - 4" MIN GROUND L v/ I I So 2"/MIN' 544" " GENERATOR TABLE: BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 00S871&005883 10 KW 25.00" 48.00 29.00" 3876s 54.00 Psf EXP E186 MPH &D180 MPH Generac 005872 & 005884 14 KW 25.00" 48.00" 29.00" 4391bs 56.80 Psf UP TO EXPOSURE D 186 MPH Generac 6459, 6461, 6462 16 KW 25.00" 48.00" 29.00" 513 lbs 56.80 Psf Generac 006721 16 KNV 25.00" 48.00' 29.00" 448lbs 56,80 Psf Generac 005873 & 005885 17 KW 25.00" 48.00" 29.00" 455 lbs 56.80 Psf Generac 005874 & 005886 17 KW 25.00" 48.00." .. 29.00" 421 lbs 56.80 Psf Generac 005875 & 00588Z 20 KW 25.00" 48.00" 29.00" 451 lbs 56.80 Psf Generac 006729 & 006730 2C KW 25.00" 48.00" 29.00" 516 lbs 56.80 Psf Generac 006551 & 006552 22 KW 25.00 " 4&00" 29.00" 526 lbs 56.80 Psf Kohler 14RE5&20RES 14-20 KW 26.00" 48.00" 29.00" 5001bs 56.80 Psf GE 40323GE & 40324GE 13 KW 35.00" 39.40" 39.00" 540lbs 49.50 Psf EXP C186MPH&D170 MPH GE 04038215KW 15 KW 33.00" 48.00 30.50 4841bs 56.80 Psf UP TO EXPOSURE D 186 MPH GE 04037817KW 17 KW 33.00 48.00' 30.50" 484 lbs 56.80 Psf GE 40330GE & 40331GE 20 KW 33 00 ' 48.00' 30.50" 6001bsU56.80P5f Briggs & Stratton 040243-0 30 KW 31.00 32.00 34 00 4301bs Briggs & Stratton 040302-2 12'KW 33.75 " 50,00 ' 3160 ' 5071bsXP 180 MPH C 1!7R! Briggs & Stratton 040303-1 15 KW 33.75 49.00 ' 31.60 S62 lbs TO E86 MPH Briggs &Stratton 040304-1 18 KW 3375" 49.00 31.60" 568lbsP Briggs & Stratton 040305-1 20 KW 33.75 " 49.00 31.60 " 570 lbs GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENTBASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF DRILLING SCREWS O TO GENERATOR (SEE GENERATOR SPECS) = = GENERATOR .�. .�. (SEE CONCRETE PAD SCHEDULE FOR DIMENSIONS & WEIGHT 4„ �--32" WIDTH 'I 54" LENGTH SIDE VIEW FRONT VIEW GENERATOR WIND D SI N REQIREMENT (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH EDITION (2014)) AT -GRADE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H, = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.44 WIND PRESSURE: P = qh G Cf = 56.80 Ib/ft2 (ASD) GENERAL NOTES 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 FLORIDA BUILDING CODE (5th EDITION). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL. CONFORM TO ANCHOR TO PAD SCHEDULE: SPECIFICATIONS STATED HEREIN SUBSTRATES DESCRIPTION CONCRETE; (2)-3/8"O TITEN HD (6000 PSI OR EQUNALEN E' MIN.) 2-3/4" FULL EMBED O CONCRETE, 3" MIN, EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR, NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. 5. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS Y" SIMPSON TITEN HD, -\ SEE ANCHOR SCHEDULE 2"x3"e." GALV. STEEL WASHER RUBBER VIBRATION PAD 3/" THICK GALVANIZED WASHER& RUBBER VIBRATION RUBBER 7 L CONCRETE PAD - PAD 6,000 PSI LIGHTWEIGHT CONCRETE PAD -� \ X CONCRETE MIX I 6,000 PSI LIGHTWEIGHT � MASTERFIBER MAC 100 CONCRETE MIX & ROAD MESH NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. 5. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS, 6. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. - 7. ELECTRICAL GROUND, WHEN REQUIRED', TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. B. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, &FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR 11, THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN. TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS, ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA M OR MEASUREMENTS DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY L VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY 2" INACCURATE INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION, 12, EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. L. BENNARDO, P.E. BERNARDO, P.E. 0 Io N Z Oa a o T® WMmuF W �MA.o M WED LL�� x�P WED a Zr-Wu�kx- Q F->QL.wa OILKa W �w0 ZZO WW C, 9 ww� U W � 5' 3UL I� U Cazw OW w It V1 0 ti w J < o- m Q O w M o U ti N C Z H w rn M a o _ Q d ED w G Lu awn 7w C o t .-. GQ Y Z 2 VM N t M � a w W co x V) O ^ z U �gZ Z M Y w O Q ad � rr ,J, ��♦P W � f ED f Q L-�FE O 0 EE�fiii 5. <S O O fly �E. J LL aa IS U Wp 0 rc zaFp p H Y E��oq C EE 1 17-3961.1 1 I E