Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED Engineering Design Pressure CalcsMelchor Consultation Services, LLC,
MelchorCS.com
PG#
4140 SW 110th Ave, Miami, FL 33165
305-343-3622
DESCRIPTION
CLIENT:
Paradise Exteriors
PROJECT NAME:
Unit 106
PROJECT ADDRESS:
16 Lake Vista Trail, Unit 106, Port St. Lucie, FL 34952
FILE NUMBER:
20-289
ENGINEERED BY: SM
WIND LOADS -
CLADDING COMPOMENTS - ASCE 7-10 ASD
LOCATION
SAINT LUCIE
RISK CATEGROTY: li
Directionality Factor
ICd =
0.85
Exposure: C
Mean Roof Building height
H =
21.25 FT
V =
165 MPH
Building Least Horizontal
L =
55 FT
Exposure Factor
KZ =
0.91
Roof Slope
0 =
SLOPED 0 > 10
Topografic Factor
KZT =
1
building type: Table 26.11-1
enclosed
G =
0.85
Building Geometry Loading
sloped
Velocity Pressure
qh - qZ
= 0.00256 * KZT * KZ * Kd * V2 =
53.9 PSF
SQFT
GCp +
GCp - (z4)
GCp - (Z5)
Gcpi
Z4 & Z5 (PSF)
Z4 (PSF) Z5 (PSF)
10
1.00
-1.10
-1.40
0.18
38.2
-41.4
-51.1
15
0.98
-1.07
-1.35
0.18
37.5
-40.5
-49.5
20
0.96
-1.05
-1.30
0.18
36.9
-39.6
-47.9
25
0.95
-1.03
-1.27
0.18
36.6
-39.1
-47.0
30
0.94
-1.01
-1.25
0.18
36,2
-38.6
-46.1
35
0.94
-1.00
-1.23
0.18
36.1
-38.0
-45.4
40
0.93
-0.98
-1.20
0.18
35.9
-37.5
-44.9
45
0.93
-0.97
-1.19
0.18
35.7
-37.3
-44.3
50
0.92
-0.97
-1.18
0.18
35.6
-37.1
-43.9
55
0.92
-0.96
-1.16
0.18
35.4
-36.8
-43.2
60
0.91
-0.95
-1.13
0.18
35.3
-36.4
-42.5
65
0.91
-0.94
-1.12
0.18
35.1
-36.2
-42.0
70
0.90
-0.94
-1.11
0.18
34.9
-36.1
-41.6
75
0.90
-0.93
-1.11
0.18
34.8
-35.9
-41.6
80
0.89
-0.92
-1.09
0.18
34.6
-35.7
-41.1
85
0.89
-0.92
-1.09
0.18
34.6
-35.5
-41.1
90
0.89
-0.91
-1.08
0.18
34.6
-35.4
-40.7
95
0.89
-0.91
-1.08
0.18
34.4
-35.2
-40.7
100
0.88
-0.90
-1.06
0.18
34.3
-35.0
-40.2
150
0.86
-0.88
-1.02
0.18
33.6
-34.3
-38.9
200
0.84
-0.85
-0.87
0.18
33.0
-33.2
-33.9
SHEET NOTES:
Engineer Carlos Melchor
FL. P.E.# 81344
C.A.N.# 32186
This item has been digitally signed and sealed by
Carlos Melchor on the date adjacent to the seal.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies
Digitally signed
by Carlos E
Melchor
Date: 2021.02.08
17:56:30-05'00'