Loading...
HomeMy WebLinkAboutEngineering Floor PlanSCOPE OF WORK: • GLAZING RENOVATION TABLE OF CONTENT: 5-000- COVER PAGE 5-100. PLAN VIEW- FIRST$ SECOND FLOOR S-300- WINDOW & DOOR ELEVATION UNIT 106 16 LAKE VISTA TRAIL, UNIT 1 PORT ST. LUCIE, FL 34952 1. SCHEDULE: i. DOORS FL #71103.1 SERIES "8900" PVC SLIDING GLASS DOOR 1.1, GLASS: Yls" TEMP. GLASS+%"AIRSPACE +Ys^ANN.GLASS+ 0.105" KURAKAY PVB INTERLAYER+Ys ANN. GLASS 1.2, IMPACT: L.M.I =1 2, WINDOWS FL#15780.8 SERIES "BARCELONA DH301" EXTRUDED PVC DOUBLE HUNG "IMPACT" WINDOW SCOPE OF WORK P k 2.1, GLASS: X* ANN. GLASS+0.090"SANFLEX EVE INTERLAYER+y"ANN,GLASS+AIRSPACE+}p"ANN. GLASS 01 SATELLITE VIEW 2.2. IMPACT. L.M.I. _00 N.T.S. 3. MULLION FL# 17472.2 CLIPPED ALUMINUM BAY/BOW MULLION -L.M.I 1. ALL DIMENSIONS 1. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. 2. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY, 3. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH THE AFFECTED PART OF THE WORK. 4, THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE, 5, IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION, 6. EXISTING WOOD & CONCRETE STRUCTURE BY OTHERS AND MUST BE ADEQUATE TO SUSTAIN THE SUPERIMPOSED LOADS. 7. ALUMINUM IN CONTACT WITH CONCRETE MUSr BE COATED WITH A LAYER OF BITUMINOUS PAIN 8, DRAWINGS ARE CHECKED FOR STRUCTURAL REQUIREMENTS ONLY, CARLOS MELCHOR,P.E. DOES NOT ISSUE ANY WARRANTIES WITH RESPECT TO WATER PROOFING OR ANY OTHER NON STRUCTURAL ITEMS REFERENCED HEREIN, DESIGN W[ND LOADS: THE STRUCTURAL FRAMING WAS DESIGNED USING F.B.C. WITH ANDTHE FOLLOWING SUPERIMPOSED LOADS. DESIGN WIND LOADS WERE DETERMINED IN ACCORDANCE WITH F.B.0 2020 AND ASCE 7-16. WIND VELOCITY: 165 MPH EXPOSURE CATEGORY: C FINISH NOTES: 1. ALL GI WINDOWS SHALL BE BRONZE TINT COLOR. 2, ALL WINDOWS AND DOORS FRAMES SHALL BE BRONZE COLOR. 02 SITE PLAN _oo SCALE 1n8'=1'-0' This item has been digitally signed and sealed by Carlos Melchoron the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verifled on any electronic copies Digitally signed by Carlos E Melchor av % Date: dP 2021,02.08 17:57:11 -05,00' ISSUED FOR PERMIT y C ui �j nor `O n O Pcrc i0 COMMENT CARLOB MELCHOR FL 13" 32186 RENOVATION 28-20B-SHOP OWG PAGE: S-000 O b d BEDROOM LIVING ROOM DINING BEDROOM 1 KITECHEN 1X4X1/4' 2 00 01 PLAN VIEW O CO O Digitally signed by This hem has been digitally signed and sealed by Carlos E Carlos Melchor an the date adjacent to the seal. (D2021.02,08 Melchor Printed copies of this document are not considered Date: signed and sealed and the signature must be verified on any electronic copies 17:57:28 -05'00' PAGE: ISSUED FOR PERMIT Fa� $gig FAw �r5 t�rc tt O K COMMENT CPRLOfi MELCHOR FL 1344 C.A.N.#32106 RENOVATION 20.20B�HI L)U RENOVATION 20.20B�HI L)U rFIFL# 17472.2 .X4X114" 747 d %/ 4 OFL#: 15780.8 O FL#: 15]80.8 ZONE ZONE i ZONES WIND LOADS ZONES WIND LOADS Pd+39.2 PSF Pd+38.2 PSF Pd-51.1 PSF Pd-51.1 PSF OFL #: 15]80.8 ZONE ZONE 4 WIND LOADS Pd +30.2 PSF Pd-41.4 PSF &D WINDOW &DOOR ELEVATION 3 FL#: 11103.1 S QTY.: i ZONE B. WIND LOADS PdPSF .41.4 Pd - 41.4 PSF OFL #: 15780.8 OTV.: 1 ZONE 4 WIND LOADS Pd+33.2 PSF Ptl-41.4 PSF ___ B.O. TIE BEAM OFL #: 11103.1 4 ZONE ZONE 5WIND LOADS Pd .PSF Pd-51.1-51.1 PSF __ B.O. TIE BEAM OFL #: 15]80.8 OTV.:1 ZONE4 WIND LOADS Pd +3B.2 PSF Pd-41.4 PSF This Rem has been digitally signed and sealed try Digitally signed Carlos Melchor on the date adjacent [o the seal. m s` M „loos E Printed copies of this document are not considered Date: signed and sealed and the signature must he 2021.0A06 17:57:42-05000' verifled on any electronic copies ISSUED FOR PERMIT y g�a I a s3 t�V n �� II �w rj t�rc n� 0 p O E C MMENT CARLOS MELCHOR FL P.E.g01344 C.A.N.#32186 ENOVATION PAGE: R 26209�H300 ENOVATION PAGE: R 26209�H300