HomeMy WebLinkAboutAPPROVED Engineering Floor PlanSCOPE OF WORK:
. GLAZING RENOVATION
UNIT 105
16 LAKE VISTA TRAIL, UNIT 10
TABLE OF CONTENT:
S 000OVER PAGE PORT ST. LUC I E, FL 34952
S-100- PLAN VIEW - FIRST & SECOND FLOOR
S-300- WINDOW & DOOR ELEVATION
NOA SCHEDULE:
1. DOORS FL #11103.1 SERIES "8900" PVC SLIDING GLASS DOOR
1.1. GLASS: YlB" TEMP. GLASS +%" AIR SPACE + 34e' ANN. GLASS + 0.105" KURAKAY PVB INTERLAYER +%s" ANN.
GLASS
1.2. IMPACT: L.M.I
2. WINDOWS FL#15780.8 SERIES "BARCELONA DH301" EXTRUDED PVC DOUBLE HUNG "IMPACT" WINDOW
2.1. GLASS: )e" ANN. GLASS + 0.090"SANFLEX PVB INTERLAYER +y" ANN. GLASS + AIR SPACE + y8" ANN. GLASS
2.2. IMPACT: L.M.I.
3. MULLION FL# 17472.2 CLIPPED ALUMINUM BAY/BOW MULLION - L.M.I
GENERAL NOTES:
1. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD.
2. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY.
3. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH
THE AFFECTED PART OF THE WORK.
4. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO INSURE
SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION.
6. EXISTING WOOD & CONCRETE STRUCTURE BY OTHERS AND MUST BE ADEQUATE TO SUSTAIN THE
SUPERIMPOSED LOADS,
7. ALUMINUM IN CONTACT WITH CONCRETE MUST BE COATED WITH A LAYER OF BITUMINOUS PAIN
8. DRAWINGS ARE CHECKED FOR STRUCTURAL REQUIREMENTS ONLY. CARLOS MELCHOR, P.E. DOES NOT ISSUE ANY
WARRANTIES WITH RESPECT TO WATER PROOFING OR ANY OTHER NON STRUCTURAL ITEMS REFERENCED
HEREIN.
DESIGN WIN➢ LOADS:
THE STRUCTURAL FRAMING WAS DESIGNED USING F.B.C. 2020 AND THE FOLLOWING SUPERIMPOSED LOADS.
DESIGN WIND LOADS WERE DETERMINED IN ACCORDANCE WITH F.B.0 2020 AND ASCE 7.16.
WIND VELOCITY: 165 MPH
EXPOSURE CATEGORY: C
FINISH NOTES:
1. ALL GLAZING SHALL BE BRONZE TINT COLOR.
2, ALL WINDOWS AND DOORS FRAMES SHALL BE BRONZE COLOR.
v I SA I LLLI I k VILVV
_O� N.T.S.
STAMPS
02 SITE. PLAN V ....,_
-OV SCALE: 1116'=1W
This item has been digitally signed and sealed by
Carlos Melchor on the date adjacent to the seal.
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies
Digitally
signed by
FE"o+
ww
Carlos E
Melchor
Date:
2021.02.08
17:58:27
-05,00'
ISSUED FOR PERMIT
a
O
w
F-
>
T
REVISION
� a
a
# DATE COMMENT
CARLOS MELCHOR
FL P.E. # 81344
C.XN, # 32186
o�
RAWING INFO
OLAZING
RENOVATION
20-289 -SHOP DWG
PAGE: S-000
8
t11�
fr��
§off
�LL
rj
G
F�p
'° 8
�a
O
rc
a
°
#
ATE COMMENT
CARLOS MELCHOft
FL P.E.#01344
C.A.N.#32106
O
a
BEDROOM
STAMPS
O
ADJACENT
UNIT
KITCHEN O
LIVING ROOM DINING
ULLION JX4XI14"
FL# 2
Digitally
O O O signed by
This Item has been digitally signed and sealed by ° Carlos E
Carlos Melchor on the date adjacent to the seal, / ��. �� Melchor a�
Printed copies of this document are not considered Date: °RA °
GLAZING
signed and sealed and the signature must be 2021,02.08 RENOVATION
01 PLAN VIEW verified on any electronic copies
17:58:41 20.20E-SHOP OWG
SCALE:3Ii6'=1'-0' -0510W PAGE: ( ^ 00
ISSUED FOR PERMIT J I
tIV
���
a
K
z &gi
�w
Fgr
ma
rc
O
rc
n
ATE
COMMENT
CARLOB MELCHOR
FL P.E.N01344
C.p.N.N32106
MULLION 1X4X114'
FLA 17472.2 .2910
364n• 36 are• sl vq'
POP
v1s•
to
ze t qq-
(o.L.o.) (o.L.o.) Io.Lo.l
_________________�m�_________—___ 8
B.O. TIE BEAM
b +�B.z In
% 4
Q
N : dl
STAMPS
�11tiG@i8 R ��
3�
4
T.O. GRADE
OZONE 6 WIND LOADS O ZONE 6 WIND LOADS O ZONE 5 WIND LOADS O ZONE 4 WIND LOADS
Pd+3B.2 PSF Pd+3B.2 PSF Pd+38.2 PSF Pd+38.2 PSF
Pd-51.1 PSF Pd-51.1 PSF Pd-51.1 PSF Pd-41.4 PSF
a4• s
0
loM, Io.L.o.l
B.O.TIE BEAM
J.
e
�Z REVISION
This Item has been digitally signed and sealed by
4 5 Carlos Melchor on the date adjacent to the seal.
R'El
Printed copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies
O FL$: 15780.8 O FL#: 15788.8
QTY.: 1 QTYZONE
i
ZONE4 WIND LOADS [ ZON8.2PSF LOADS Digitally
Pd +38.2 PSF Pd +38.2 PSF signed by
Ptl-41.4 PSF Pd-41.4 PSF
os E
MelCarlcho aE
T.O. GRADE Melchor D
Date: ruw NG
1G'4_e� GLAZING
2021.02,08 RENOVATION
&D WINDOW & DOOR ELEVATION 17:58:56 =88-SHOJP DWG
_30 GCALE:3I0•=1'-0' -05,00, PAGE: S�J OO
ISSUED FOR PERMIT
D�RRt'�'
R