_ Planning&Development Services J _ v Building&Code Regulation Division � 2300 Virginia Ave,Rm 201 RECEIVED Fort Pierce,FL 34982 Phone:772-462-2165 Fax:772-462-6443 NOV - 1 2018 BLOWER DOOR TEST FORM House Infiltration Test Certification Permitting Department Prescriptive and Performance Method St. Lucie County, FL Date: 1 i l R Permit#: 51-C l -1 I o •- 0 1 3 Contractor: Wy e^4 Job Address: 3 9 '�-3 C+. j a 'rF�C-' J-L L� QSI Construction: " New Construction-Complete ( ) Existing-After Addition House Infiltration Test Results SLC Climate Zone 2 ( CFM (50)= 12_a 1- Test Date: l I Volume= —3 -7 0 ACH(50)=CFM(50)x 60/Volume= Z Mechanical Ventilation required less than 3 ACH Passing results must be&ACH(50)or less Pass ( )Fail FBC,Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g)or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC,Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w.c.(50 Pa)in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro-Duct Services Address: 1915 Rio Vista Dr., Ft Fierce 34949 1 hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Martin Klein License/Certification#: 5061633 RFC p BOG `Fo. SC 90 Planning &Development Services 41e °pd J Building &Code Regulation Division °�')4 ® 2300 Virginia Ave a Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: 1710-0113 JOB ADDRESS: 13953 GERANIO FORT PIERCE,FL 34951-4214 BUILDER/CONTRACTOR: WYNNE DEVELOPMENT PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 200 LF Chemicals used: DOMINION 2L Percentage of solution: .05% Total gallons used: 115 Date of Treatment: 05-17-2018 Time of Treatment: 1:00 Footing Slab 1st Treatment 1st Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-Treat Other xxxxx Perimeter for Final Inspection 1st Treatment signedRe-Treat PAUL C LUGARA JR Datto Diglinl018.1101Y14 18 06-04'00'' 11/02/2018 Signature of Exterminator Date Note. There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment,site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 fir,'' j� r Orr ti Ij W ti+iOriA�' egaa�IW '�ll/�Slddt <U��depa . .��,��',>.�.:.• . e co �ear ./� � ~L`ir4 ii• Fax 77C-462- 3 Pmject Addis: THE UND,8RSIGNED HEREBY REQulgT MLEASE OF El..ECfRM POWER TO THE ABOVE DESCRIBED _ PROPERTY,FOR A.PERIOD NOT'TO MEW fif-lI TY(30)DAYS, FOP,THE PURPOSE OFTEMNG,SYSTEMS AND EQUIPMENT IN P1 ARATION.l*OR iA.FIN;<L.INSPEMO - IN CONSIDWTION OF APPROVAL.QF THE REQUEST ti -HE f ACI ' •EbGE AND AGM-AS FOLLCM 3. 1bis.*PiaiY power r elease is jtq*tt.W£or#,z=aS ve sled pose only,and hn 41 be no ocWpancy of any Wpe,qffier than-that permitted by corj Lion dLiring this time period. 2. As witria%by.our signatui*,*.hey.a9r1e U?abide by aft terms and-conditions of this agreement, indediiig Building' Division Policy,which is incorporated hiar n by reference. 3. All condMons:and tequkemdnts(is�i'in the atfa hed document ent�led"R,equU menu for 30 Day Power for'Teftg-havelab n fulfilled End th6 premise is ready for-compliarice-inspeocn. 4. All ri CquesM for anti exlensiori beWpd 3-0 days must b.i.�;made in wri#rag to ifie Building a Baal stating fhe-repAor orthe re-v Power maybe rqrpoved'frvrrt the site andjor a Stop 1YVoricOrder issued.tf the Final TnspdWdn has riot seen-approved within 30dad s. A€ee 6f$100.00 will be regiared to lift the Slap Worts Order. WE HERESY REi.ME•AND AGREE TEt HOLD HA.P ,S7 L.:U COUNTY,Agin THFIR EMOLOYEM 1 M ALL BEM- ES AN()C. 0F�ANY TYRE-.(3KM- TURF ItlWCH KAY ARISE NOW OR IN THE FUTURE OUT O>✓TH ri,$,TRMSA�ON,INCLUDING ANY�©AMAG5W,,HlCpi'MAY BE INCURRED'OUE TO THE D l��M d aECTRIr'.AL,Fo*&M Ti-IF EVENt 6F V16 ATION OF THIS AGREEMENT. �VNitVtIGl11 ' DATE CAVE �t3t11TRA"J DATE ELtCM,CAL COMMC.M. Sid_NA-ME 17A�E' 08£-A ti000/ti000d 669-1 999L8LKLL -W0dj 0 L=£L K 8 H L RECEIVED � - - C Permitting Department St.Lucie County Professional Insulators of South Florida FTC Insulation Installation Certificate To: St Lucie County Date: July 2,2018 Re: Lot/Block.- Address: 13953 Gerrnio Court Project: The rsigned herek certifies that insulation has been installed in the above described p2Mrty as follows: 1. Exterior CBS walls have been insulated with: Spray-on Cellulose Thickness in inches: Fiberglass Blankets Manufacturer: Fi Foil Rock Wool Blankets Density: X Aluminum Foil R-Value: R 4.1 Rigid Board Polystyrene Other 2. Ceilings(level)have been insulated with: Spray-on Cellulose Thickness in inches: 11.1" X Fiberglass Blown Manufacturer. Climatepro Rock Wool Blankets Density: Aluminum Foil R Value: R-30 Polyurethane Open Cell SPF Ceilings(Inaccessible)insulated with: Spray-on Cellulose Thickness in Inches: 9.5" X Fiberglass Blankets Manufacturer: Johns Manville Ignition Barrier Density: Fiberglass Blown R-Value: R-30 Cellulose Loose Fill Open Cell SPF 3. Interior kneewalls have been insulated with: Fiberglass Blankets Thickness in inches: Fiberglass Lo . IV Manufacturer. Rock Wool • Density: Fiberglass twn R-Value: Cellulose Loose Eill Open Cell S F 4. Garage partition walls of A/C living area have X IFiberglass B ak is C" been insulated with: ARock Wool Thickness in inches: 3.5" Polyuretban Manufacturer: Johns Manville Spray-on C Density: j0penCellSyr R-Value: R-11 5. The following have been insulated: m f1pN f f f t���I WYKM BUILDIKG CORP. ��'�►'••��^'ip .Oi.� '��_. General Contract/Builder SEAL 4%9 2003 CBC1254041 �ir;W. .!tios<ti�• c� Competency# �.,�j •.... �� Professional Insulators of South Florida,Inc. •►. BOA*��• Insulation Contractor 1494 By: By: �, ' Planning &Devepop pent Services BuiQding a Code ReguQetQon Division / - - 2300 Virginia Ave • Fort Pierce,FL 34982 772-462-2172 Fax 77 2-462-6443 C ER79MME OF TERNRTE TREATMENT PERMIT #: f 7 D -U'I13 JO ADDRESS: 3 BUILDER/CONTRACTOR: Atv Phil PEST CONTROL CONTRACTOR: EVICT-A-B G TERMITE&PEST CONTROL INC. PEST CONTROL LICENSE #:JB176775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. sz Square feet if area treated: Chemicals used: DOMINION 2L Percentage of solution: .05% _ Total gallons used: Date of Treatment: Time of Treatment: o ' Footing Slab ~-- - - =-- _- ----- -, -. — - - 15t Treatment 15t Treatment Re-Treat Re-Treat Driveway Pools Ist Treatment 1st Treatment Re- reat Re-Treat Other 411 Pe:meter for Final I ction —1st Treatment Re-Treat 711� Signature of Exterminator Date Note., There must be a completed form for each required treatment or re-treatment and this form must be on th&job site to be picked up by the Inspector at time of each inspection or the scheduled Inspection will fall and a re-Inspectlon fee charged. IFBIC104.2.6 Certificate of Protective Treatment for preventlon of termite.. A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit Is Issued to and another copy for the building permit flies The Treatment Certificate shall provide the product used, idendly of the applicator, time and date of the treatment,site location, area treated, chemical used,percent concentration and number ofgallons used, to establish a venflable record of protective treatment If the soil chemical barrier method for termite prevention Is used, final exterlor treatment shall be completed prior to Final building approval, St Lucia County requires for the final inspection for CO. a Permanent Sticker to be psiaced on the electrical panel box Icoverr [listing all the treatments and dates of applications. ReYisod 7/2 4/2014 I KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED January 30, 2018 KSM JOB# : 180313-1 d/MH/ct PERMIT# 1710-0113 RECEIVED CONTRACTOR Wynne Development JOB LOCATION 13953 Geranio Court FEB 0 7 2018 Spanish Lakes Fairways ST. Lucie County, Permitting - Fort Pierce, Florida - — - - ------ - ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 52 112.7 116.1 97.1 2. S.E. 1151 111.4 1196.0 3. Center it53 113.8 98.0 4. N.W. 54 114.8 98.9 5. S.W. 51 111.9 96.4 Soil Description: Brown Sand with 117.0 i I I I I 1 Shell Fragments W I I I I I I In Place Moisture: E I I I I I I 8.9 Percent 1 I I I I I Optimum Moisture: H 11.0 Percent T I I I I I Max. Dry Density: p 1 116.1 P.C.F. 115.0 • I I I I I C @ Test Locations The Density & Penetrometer F I I I I Readings Indicate the 114.0 Degree of Compaction Meets I I I I 1 Minimum Required D I I I I I I for Sta4,ed0oundation. R I I I I I kVn to Natural Grade. Y 113.0 e ; "'Sr 8 9 10 11 12 13 14 . m + Moisture-%of Dry Weight y bate E. KelleT OF� e APPROVED "'oa5 ,arlIgo �St� acre County Building Department E� �[ ��ott Dig hlakes.com °sEa���3D1tey�,d�bnaId G. Keller, P.E.: 37293/SI Lic. No.:860 / Julie E. Keller, P.E.: 68366 Planning Development Services Building &Code Regulation Division 2300 Virginia Ave • e Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SOIL TREATMENT PERMIT #: 17� D Ott TATDRESS: 1-3- �3 i d C4- , Fos'-+- P't',re e'-, BUILDER/CONTRACTOR: PEST CONTROL CONTRACTOR: EVICT A-BU TERNDTE&PEST CONTROL INC.. PEST CONTROL LICENSE #:JBI75778 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. s Square feet if area treated: Chemicals used: DOMINION 2L Percentage of solution: •05% Total gallons used: Date of Treatment: - Time-of Treatment: _% 0 O Footing -,Z.SI b 1st Treatment ist Treatment Re-Treat Re-Treat Driveway Pools 1st Treatment 1st Treatment Re-Treat Re-Treat Other erimeter for Fi nspection 1st Treatment Re-Treat /')'- Signature of Exterminato Date Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled Inspection will fail and a re-Inspectlon fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment Is completed, providing a copy for the person the permit Is Issued to and another copy for the building permit files The Treatment Certificate shall provide the product used,Identity of the applicator, time and date of the treatment,site location, area treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of protective treatment If the soil chemical barrier method for termite prevention is used,final exterior treatment shall be completed prior to final bullding approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the a➢ectrical panel box coder, listing all the treatments and dates of applications. Revised 7/2 412 0 1 4 01/31/2018 15:46 772 646, KSM ENGINEEW PAGE 01/01 TAP C! . .III17 m KELLER, SCHLEICHER & Mar—WILLIAM ENGINEERING AND TESTING, INC. MARTIN(772)337-7765 PO. BOX 78-1.377, SEBASTIAN FL 32978-1377 SEBASTIAN(7'72)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MEL13OURNE(321)768-8488 FAX(561)845-8876 E-Mail:K5M@KSMEN GIN EERING.NET ST.LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED : January 30, 2018 KSM JOB#: 180313-1 d/MH/ct PERMIT# 1710-0113 CONTRACTOR Wynne Development JOB LOCATION ; 13953 Geranio Court Spanish Lakes Fairways JAN 31 2010 Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N_E. 0"- 121, 52 112.7 116.1 97.1 2. S.E. IT51 111.4 7196.0 3_ Center it53 113.8 IT 98.0 4 N W It 54 114.8 98.9 5. S.W. 51 111.9 96.4 Soil Description: Brown Sand with 117-0 I I I I r Shell Fragments W In Place Moisture: ! 8.9 Percent E I I I 1 I G 116.0 �—.. �..—..�.._... Optimum Moisture: H I I I ! 11.0 Percent T Max. Dry Density: 116,1 P.C.F. P G @ Test Locations The Density& Penetrometer IF I I I I Readings indicate the 114.0 I —.I._••—t._..�.._._ Degree of Compaction Meets Minimum Required D l I I I I for Stsp� wV tion. R I l 1 I I I ^ ti1_� dis [ f n to Natural Grade, y 113.0 - �� 8 9 10 11 12 13 14 r e Moisture-1'Rf�►e" h e E. Kelie . PARTIAL APFMbVA1 8OF 4 �'b �ff�'ie County Building Department r hlakes.com rid°9f �A��Pdl�rtald G. Keller, P.E,:37293/SI Li(:- Na.:860 / Julle E. ICcller. PE-:Eaa8366 Q�'lDPOIS/SO A KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712 PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488 FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093 C.A.:5693 FAX(772)589-6469 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 2922 DATE TESTED January 30, 2018 KSM JOB# : 180313-1 d/MH/ct PERMIT# 1710-0113 CONTRACTOR Wynne Development JOB LOCATION 13953 Geranio Court Spanish Lakes Fairways Fort Pierce, Florida ITEM TESTED Compacted Foundation Fill TEST LOCATION DEPTH * PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 52 112.7 116.1 97.1 2. S.E. 51 111.4 96.0 3. Center 53 113.8 98.0 4. N.W. 54 114.8 98.9 5. S.W. 51 111.9 96.4 Soil Description: Brown Sand with 117.0 i I I I I 1 Shell Fragments W I I I I I I In Place Moisture: E I I I I I I 8.9 Percent Optimum Moisture: H I I I I I 11.0 Percent T I I I I I I MaX. Dry Density: p I I I I I I 116.1 P.C.F. I C I I I I I @ Test Locations The I I I I I I Density & Penetrometer F I I I Readings Indicate the 114.0 Degree of Compaction Meets I I I I I Minimum Required D I I I I for Stakeq jioumd4qn. R I I I I I * Pen,�Aegp _s e 49 Natural Grade. Y 113.0 — Re��+q�q+� ° C` '. 8 9 10 11 12 13 14 Moisture-%of Dry Weight a- J!tjI - eller, a w.. kd�entS7 OF :427 F`:, ibtfkt t u re Bounty Building Department Ema[I, rru�'tty@sq �sh(�i�Ces.com ��OOYeR,.N�y�•R(� f99p0 1�i`rda eG. Keller, RE.:37293/SI Lic. No.:860 / Julie E. Keller, RE.: 68366 AL rt OF SURVEY: BOUNDARY PLOT PLAN U C TIE IN I VFFINAL TOPOGRAPHIC COMPLETED ON: 1-30-18 I DESCRIPTION: SURVEYORS NOTES: BEING ALL OF 13953 GERANIO COURT, 30 1, UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE OF THE UNRECORDED PLAT OF FAIRWAYS SHOWN HEREON. OF ST. LUCIE COUNTY, FLORIDA. 2. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 3. THIS SITE LIES WITHIN FLOOD ZONE 'X ACCORDING TO II THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. ABBREVIATIONS: . 12111 CO065 j, EFFECTIVE DATE 2-16-12. 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE FFE = FINISHED FLOOR ELEVATION 0 N .. SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD R/W = RIGHT—OF—WAY IJ ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. R = RADIUS OF CURVE =V 5. BEARINGS SHOWN HEREON ARE REFERANCED TO THE L = LENGTH OF CURVE CENTERLINE OF GERANIO COURT HAVING AN ASSUMED SF = SQUARE FOOT 15 BEARING OF EAST, ACCORDING TO THE UNRECORDED PLAT A = DELTA OF CURVE OF FAIRWAYS, OF ST. LUCIE COUNY, FLORIDA 6. NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED 30 SEAL OF A FLORIDA LISCENSED SURVEYOR AND MAPPER. 7. THIS IS A SPECIFIC PURPOSE SURVEY FOR THE PURPOSE OF LOCATION AND ELEVATION OF FORMBOARDS. BOUNDARY LINES SHOWN HEREON ARE FOR GRAPHICAL PURPOSES ONLY. Date Approved PERMIT #: ` ' l o 3 EXISTING GERANIO COURT 20' PAVED ROAD o o) 33.78 61.8B' m o AVERAGE TOP 10.03' SITE BENCKMARK 5.19' OF FORMS OPEN ELEVAnON- 24.45 m ELEVATION=26.60 ASSUMED ,� 2.15' ABOVE EDGE Nti 11.14 OF PAVEMENT 61, N ° N `9S• 57.89' 10.03' J v EXISTING FEB 2 2018 LAST FIELD DATE: 1-30-18 Windows & Doors ' (8001876-0643 i West MRet Gratz 17030 rp t i Series 185 Aluminum Windows Insulated 420 Series Aluminum SGD Insulated Glass - RLE5527 Tempered Glass.- HPLOE aW, -# 0.54 0.25' 0.55 0.25 ON 0.44 < = 0.3 0.47 00 '• ''. .wed�asalbtr��at za.� � .i!ne�tel . ,gyp: �R:��r �l1d�DR1g 391of ��' as Js. a