HomeMy WebLinkAboutproject infoACCEPTABLE ALTERNATE EXTEND THIRD TO SHEATHING BELOW ADD SEALENT AT CONNECTION PROVIDE TAPCON SCREWS OF ADEQUATE LENGTH TO SECURE BRACKET TO CEMENT TILE, DRILL HOLE THIRD GONG, TILE AND INSTALL TAPCON SO AS NOT TO BREAK TILES. 1/4" LAG ACCEPTABLE ALTERNATE OR #14 PHIL PAN OR HEX HEAD ACCEPTABLE ALTERNATE NOTE: THE MOUNTING BRACKET BY IRONRIDGE IS ACCEPTABLE FOR INSTALLATION OF THE PANELS PRVIDE 3/8"x 2 1/2" LAGS 4FT & 6 FT O.C. MAX TO EXISTING TRUSSES BELOW S-5 CLAMP PANELS S-5 CLAMP 3" PANEL HIT .032 THICK STANDING SEAM C❑NNECTI❑N Pll XPRDWME $IPINLE55 OR WLV PANELS SHALL NOT BE INSTALLED IN CORNER ZONES OF ROOF ASSEMBLIES. y�A w RIDGE Q PANEL ROOF CORNER ZONE SHALL BE 10 PERCENT OF SHORT DIMENSION OF BUILDING OR 40 PERCENT OF MEAN HEIGHT, OR 3 FT. WHICH EVER IS SMALLER. upper hold down clamp see detail A or optional detail A-1 4'x8'. 10' or 19' ;Dior panels �LljX F E STRAP Bf A KET DETAIL C X C E NOTE: EAGLE CLAW PLASTIC ALUMINUM TOP CLAMP HEADER BRACKET ACCEPTABLE ALTERNAIc 1/4"-20x3 /4" La S.S. DR PAN HEAD "PAN HEAD EAD SCREW IOFING MIN. 1/2" IT OR PLYWOOD SHEATHING STRAP SPACING upper clomp asseml`i y retail A-1 48" O.C. MAX sirap'u V"' LowER/RET LOWER hold down clamp see detail B PLEASE NOTE: LOWER CLAMP/SPRING ASSEMBLY MAYBE OMITTED PROVIDED A CONTINUOUS CROSS STRAP 15 INSTALLED NO MORE THAN 12" ABOVE LOWER/RETURN ASSEMBLY 0 PANEL z w a RIDGE � R❑❑E TAY❑UT GENERAL C❑NDITI❑NS 1. THE SOLAR COLLECTOR INSTALLATION AS DETAILED IN THE DRAWINGS IS FOR THE INSTALLATION OF POTABLE WATER HEATING SYSTEMS ON STRUCTURES UP TO 35 FEET IN HEIGHT WITH ROOF' SLOPES BETWEEN 0 AND 30 DEGREES, ROOF AREAS 1 AND 2 BUT NOT CORNERS. 2. THE DESIGN OF THIS INSTALLATION IS BASED ON ASCE7-10 FOR SURFACE AREAS BETWEEN 20 AND 48 SQUARE FEET RESULTING IN A MAXIMUM WIND PRESSURE OF <= 67 PSF. THE INSTALLATION SHALL UTILIZE HARD- WARE PROVIDED BY THE MANUFACTURER AS DETAILED IN THE INSTALATION MANUAL OR AS SHOWN ON PLAN. P, -# 14Y 1 1/2"PAN HEAD �R HEX HEAD SCREW. )FING MIN. 1/2" O.S.B. OR PLYWOOD SHEATHING upper ClaOmp assembly detail A SPRING ASSEMBLY ._ ----------- ---ION 1/2 -PAN HEAD iEAD SCREW. lower clamiD assem)b ROOFING — MIN. 112" O.S.B, OR PLYWOOD SHEATHING detail B Ch E � O � V Q InnLUJ M U W �W W Q BID LP WQ - z W W i Y i D' fy DO to Qo .N W z d W Z 3 W y W 00 X Z Y iU CD W WQ 0 z U JW OT Q Q rn r BE Y = 0 N Q N 0 - Z W Z W DOCE OJ Q ED — UU CC W r` J W N O > GO 0 W sE Z H E7 z O WJ _z DID w O z Y CD z w J DOQ N LLJZD U 0 NOTE: LOWER CLAMP/SPRING ASSEMBLY MAY BE DELETED PROVIDED BOTTOM CONTINUOUS STRAP IS LOCATED WITHIN 12" OF BASE REVISION GATE MOUNTING BRACKET # 14X 1 1/2"PAN HEAD STRAPPING OR HEX HEAD SCREW. i ROOFING ENSURE TILE CAVITY IS FILLED COMPLETLY WITH DOW TILE BOND ROOF TILE ADHESIVE OR EQUAL. APPLY ADHESIVE TO TILE AQUA THERM MOUNTING BRACKET 15 ATTACHING TO PLUS ALL PROVIDE #12 SCREWS W/CONICAL TILES AROUND IT (5) MINIMUM, ADEQUATE LENGTH TO SECURE BRACKET TO CEMENT TILE, DRILL HOLE THRU CONC. TILE / AND INSTALL SCREW SO AS NOT TO BREAK TILES, 112" O.S.B OR PLYWOOD_ ROOF DECKING STRAP BRACKET TILE R❑❑TOTE PANEL RISER SYSTEM GONG. BARREL/FLAT TILE 011 LMQ ppgg yry97 RAFTER APR 10 20 PERY0ITTiPIG St. LNGie C7': ' . FL MIN, 1/2" OR PLYWOOD E /' FLORIDA BUILDING CODE 2014, 5TH EDITION TO INCLUDE THE EXISTING CODE ULTIMATE DESIGN WIND SPEED: 180 MPH NOMINAL DESIGN WIND SPEED: 140 MPH RISK CATAGORY: I IMPORTANCE FACTOR: 0.87 EXPOSURE CATAGORY: B INTERNAL PRESSURE COEF: +-0.18 ENCLOSED STRUCTURE STRUCTURAL COMPONENTS OF THIS PLAN ARE IN COMPLIANCE WITH THE 2014 FLORIDA BUILDING CODE, WIND LOAD COMPLIANCS AND ITS RESISTANCE TO W H Z DATE 01-10-17 BY JCK SHEET %e�