Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
REVISION WITH PLANS
W4� vis;a� WE USE OL: .'E FILED: PERMIT# 1710-0113 ISION FE RECEIPT# a PLANNING&DEVELOPMENT SERVICES PUNTY BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE • R FORT PIERCE,FL 34982-5652 (772)462-1553 FAX(772)462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION L10 'O"IN53 Geranio ADDRESS: DETAII:ED DESCRIPTION OF PROJEC T REVISIONS: Changing to Impact Windows and Adding a 6x10 Slab Off Rear of Home I CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#: 8898 BUSINESS NAME: Wynne orpora ion QUALIFIERS NAMED South UMTT MEWui e ADDRESS: S00 wy 402 CITY: Port St. Lucie STATE: ZIP:. PHONE(DAYTIME): (773) 878-5513 FAX: 772 878-7 56 OWNER/BUILDER INFORMATION: Nam: Wynne Building Corporation ADDRESS: 8000 SouthHwy. I Suite 402 CITY: rULL 3L. JUU1U STATE: FL ZIP: 34952 ,j PHONE: (772.) 878-5513 FAX: (772)878-7656 ARCHITECT/ENGINEER INFORMATION: NAME: BRADEN&BRADENskill 'Ift ADDRESS: 417 COCONUTAVE. CITY: STUART STATE: FL PHONE(DAYTIME): (772)287-8258 FAX: 1 Revised 07/22/2014r MEMO` Permit _- �- : _. ; � :.. . •. . •: _. - .,.:��-mot a � ......� � . �'0. r./ ,.. .. .A6 .. • '•3 S iL �! pl. -i J. File Co ' 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Str A t: WYNNE DEV. Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE FL Permit Permit Number: �Owner: \ j3, cnaxzn�--z,, Jurisdiction: Design Location: FL,Fort Pierce County:: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1688.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1448.70 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. II this a worst case? Yes 10.Ceiling Types (1720.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1720.00 ft2 6. Conditioned floor area above grade(ft2) 1720 b.N/A R= ft2 1 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(155.4 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 250 a. U-Factor: Sgl,U=0.63 115.42 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted�Average SHGC: 0.240 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (1720.0 sqft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1720.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 55.37 PASS Total Baseline Loads: 56.24 1 hereby certify that the plans and specifications covered by Review of the plans and -T%E S-P this calculation are in compliance with the Florida Energy specifications covered by this O = per Code. calculation indicates compliance with the Florida Energy Code. PREPA D Y: Before construction is completed DATE: this building will be inspected for d -7 y i compliance with Section 553.908 - Q ¢ I hereby certify that this building, as designed, is in compliance Florida t 05� with the Florida Energy Code. OD y T4 OWNER/ BUILD . DATE: DATE:'_ I - Compliance requires certification by the air handler unit manufacturer a ' h d r u a i as certified factory-sealed in accordance with R403.3.2.1. r -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). File Copy 4/17/2018 8:47 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE ROYALE IMPA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: i CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS (Number Name Area Volume 1 Entire House 1720 13760 SPACES (Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes' 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 343 ftZ ---- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ftZ ---- 0 1 0 3 Slab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ftz ---- 0 1 0 4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ftz ---- 0 1 0 5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ftz ---- 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ftz ---- 0 1 0 I 7 Slab-On-Grade Edge Insulatio ENTRY 6.3 ft 0 98 ftZ ---- 0 1 0 i 4/,I 17/2018 8:47 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 I ■14 FORM R4105-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab-On-Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft2 ---- 0 1 0 I 10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft 0 169 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul: (deg) 1 Gable or Shed Metal 1813 ft2 286 ft2 Light 0.6 No 0.9 No 0 18.4 I ATTIC VI # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic(Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 98 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 528 ft2 0.1 Wood 10 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent CavR_Vaity Width Height Sheathing Framing Solar Below Space 1 N=>SE Exterior Concrete Block-Ext InsdHEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block-Ext InsiHEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block-Ext InsiBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block-Ext InsuM.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 5 N=>SE Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block-Ext InfiEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 7 NE=>S Exterior Concrete Block-Ext InOEDROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block-Ext ImUDROOM 2 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 9 SE=>W E 2 Exterior Concrete Block-Ext In�DROOM 2 4.1 2 10 8 0 22.7 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block-Ext InREDROOM 2 4.1 14 0 8 0 112.0 ft20 0 0.5 0 11 NE=>S Exterior Concrete Block-Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft2 0 0 0.5 0 I 1 12 E=>SW Exterior Concrete Block-Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 4%17/2018 8:47 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 I I T FORM R405-2017 WALLS Adjacent Cavity ity Width Height Sheathing Framing Solar Below Ornt In JA1,q11 Type 13 S=>NW Exterior Concrete Block-Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 1 14 N=>SE Exterior Concrete Block-Ext Ins9REAT/DINI 4.1 28 0 8 0 224.0 ft2 0 0 0.5 0 1.15 W=>NE Exterior Concrete Block-Ext Ins©REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 16 N=>SE Exterior Concrete Block-Ext InQEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 17 N=>SE Garage Frame-Wood BEDROOM 3 11 30 8 240.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2 I WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 4 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>SW 8 Metal Low-E Single Yes 0.63 0.25 N 23.2 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 14 Metal Low-E Single Yes 0.63 0.25 N 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 15 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft2 10 ft 0 in 1 ft 4 in None None 6 N=>SE 16 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None I GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 300 ft2 300 ft2 30 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 I COOLING SYSTEM V # System Type Sub y yp type Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 I I 4/I 7/2018 8:47 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 i i FORM R405-2017 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I DUCTS --Supply— ----Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Pri gramable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May ri Jun X Jul ri Aug rI Se [ ]Oct Nov Dec Heatin HJan HFeb Mar f Apr I May Jun Jul Au Sep [ ]Oct Nov H Dec Ventin Jan Feb X Mar [X]A r May Jun Jul Aug Se [X]Oct X Nov Dec TheImmostat Schedule: HERS 2006 Reference Hours Sche dule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i • I I i I I I 4/17/2018 8:47 AM EnergyGauge@)USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 i i 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE ROYALE IMPACT Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST.LUCIE COUNTY City,State,Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Fort Pierce I COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Irequirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic y pp g The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. (Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. (Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation land cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing j members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. !Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to i exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. (Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring j and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind poping and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be I prinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinWg rover lates and walls orceil ai In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 4'/17/2018 8:47 AM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. i J WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. ILingle family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1448.70 ft2 b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1720.00 ft2 6. IConditioned floor area(ft2) 1720 b. N/A R= ft2 7. Windows'* Description Area c.N/A R= ft2 . U-Factor: Sgl, U=0.63 115.42 ft2 11.Ducts R ft2 SHGC: SHGC=0.25 a.Sup:Attic, Ret:Attic,AH:Attic 6 250 b. U-Factor: Sgl, U=0.65 40.00 ft2 SHGC: SHGC=0.21 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.240 8. Floor Types Insulation Area 14. Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1720.00 ft2 EF:0.97 Ib.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat i I certify that this home has complied with the Florida Energy Efficiency Code for Building 'TUESr Construction through the above energy saving features which will be installed (or exceeded) .yO4 = A��o in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. tv Builder Signature: Date: -i �T Address of New Home:� 52j �gQ�� � City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 8:47 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1