March 22,2017
To: Building Department
RE: Palm Harbor Home, Serial Number#20741, Model 340TL40443A
Savanna Club, Site 7505
Dear Plans Examiner,
The site-beam,which was installed by Palm Harbor Homes, and is approved by HUD,
Manufactured Home Construction &Safety Standards, is constructed to receive on-site
additions that are built and designed by others to accommodate such amenities as
carports, sheds, and screen rooms. The on-site structure must be designed by a Florida,
registered, engineer,to the Florida Building Code and all local codes. This plant-
installed site beam is of adequate design for this purpose as long as tie downs and piering
are per page 1 of Section 11, Misc. &Final Inspection section of the installation manual
(attached). The attached details, EW-216.2 and PA69-EW-31, are approved by the
Manufactured Home Construction&'Safety Standards. And,the design loads for the
plant-installed site beam, as well as the supporting structure and anchorage are from the
FBC and ASCE 7.
I can be of further assistance at the above contact information.
Sincerely yours,
i
i
I,
�I
Bruce Bussell
Engineering Manager
Palm Harbor Homes
LE �iirr
y r i
1 T
I
option 9: using 2x4 let-in into dadoed 2x6 wall stud
Metal Fist Typ.TMW
2x4#3 S-P-F LAWn
Fasten into each wall stud
with a as.0.13b0"naU%.
Roof Panel or 5-as 711W IW5ga
Sewre,Roof Panel Header staples.AIL-4-*8�X3'acrewvg�
Into Z 4 ens approved by
the menulacwrees
Installation Irons:
she6�thing
i.e.:The►nmoy,Tlwniosheath
Roof Panel Head oSs or Plywood.
Lap Race
Lap siding loons Caulk
donne C.Doeden,P'.E:
K2 Enolnesfkny. lrtc.
option 2: using 2x4 installed on top of sheathing
and exterior-wall studs
Aluminum fmt stock
Typ.Tru shaped around 2x4
and steed Into soffit
and vilwafi*g;wJ metal
acre w.
Roof Panel 2�c+t tY3.S=P-F
Fasten k to each wal!'atpo
Secure Root Panel Header with 4 ea.#8X3'screws.
Into 2x4 as apprroved by
the manufmWre's
inetallatfan Irishudions.
Root Panel Header approved sheathing
Sllkxure Caulk I:e,:Thermoply,Themroshim t
p R,eaetve OSB or Plywood.
Lap Siding
APPROVED PFS Corporation PALM HARBOR HOMES, INC.
Madison, WI 1 15303 €fALLAS PARKWAY, .SUITE 860. ADDISON. TX 7500,1
mtr- DAM 09/18/40
O C T 0 3 2000 Screen room and Carport adschment
Fadtaly prep options,
HUD Manufaettired Home em;F-Ma.
Gonstru'ptaon-& EW — 216.2
Standard WIND ZONE 7&3 I
tot!—r12