HomeMy WebLinkAboutBuilding plans.BUILDINS DATA E DESIGN PRESSURE SCHEDULE
PROJECT/NAME
SHEARER RESIDENCE
M.A. CORSON E
ADDRESS:
zoos N,w. LAUREL oAK LANE
ARCHITECT
11
ASSOCIATES, INC,
PALM CITY, FLORIDA
ALL PRESSURES CALCULATED WITH THE FOLLOWING:
I.
WIND LOADS BASED ON FLA. BUILDING CODE 2014
8, WALL ZONE (PSF): 4) +42.4 / -46.0
(5TH EDITION) k ASCE 1-10, AND 2011 N.E.C.
5) +42.4 / -56.1
2.
BUILDING DESIGNED AS: ENCLOSED OPEN
9, GARAGE DOOR (PSF): N/A
3,
MEAN BUILDING HEIGHT: 13 FT, ROOF PITCH: 5 /12
10, LOADS: FLOOR 60 PSF
INTERNAL PRESSURE COEFICIENT +/- : 0.18
ROOF/DEAD 15 PSF ROOF LIVE 30 PSF
4,
WIDTH OF END ZONE: 4'
II, SHEAR WALLS CONSIDERED FOR STRUCTURE?
WIND SPEED: 1-10 MPH 3 SECOND GUST
YES X NO
5,
RISK CATEGORY I -I. ASCE 1
12. CONTINUOUS LOAD PATH PROVIDED?
F.B.C. TABLE 1604.5 II
YES X NO
6.
EXPOSURE CATEGORY: C ADJUSTMENT FACTOR: 1.45
13, ARE COMPONENT t CLADDING DETAILS PROVIDED?
i.
COMPONENTS < CLADDINGx WIND PRESSURE ON:
YES X NO
ROOF ZONE (PSF): U +24.5 / -38.9
14. SOIL BEARING CAPACITY: 2500 PSF
2) +24.5 / -61.8 3) +24.5 / -100.2
PRESUMPTIVE:_BY TEST: X
15, TYPE CONSTRUCTION (TABLE 601) (IS
-ALL ZONES CALCULATED FOR WORST CASE SCENARIO, CIO S.F. EFFECTIVE WIND AREA)
$TI—I EDITION FL. $UILDING CODE (2014) FOR
EXISTING BUILDINGS
SUMMARY:
THE ALTERATION AREA HAS BEEN
DESIGNED TO: LEVEL 2
Section 502 Repairs of the 5th Edition FBC (2014)
Existing Building
less than 50% of the aggreregate area
The lateral -force -resisting system of the existing
structure Is adaquate to withstand any new lateral
loads of the new addition per Section 801.E of the
5th Edition FBC (2014) Existing Buildings.
• The existing residence has hardwired smoke alarms and
the new addition shall be hardwired and Interconnected
to the exist. system where accessible Per R314.3
5th Edition FBC (2014),
THE ADDITION HAS BEEN DESIGNED TO: CHAPTER 8
Chapter 8 of the 5th Edition FBC (2014) Existing Buliding
a 2014 FBC 4 CHAPTER 6 OF ASCE 1-14
TOP PLATE OR WOOD
BM. - SEE PLANS
ui : - I
EXIST. -Pressure treated full length stud
BLK. WALL against 8" x 16" column block, with
precut studs adjacent. Attach all
etude to poured column block with
1/2" x 8" H11tT Kwik 8olto, or equal, at
24" o.c.. Use Palm Beach County
3" x 3" x 114" steel washers at each
- bolt.
Pressure treated full lergth stud
EXIST. against 8 x I6 column block, with
BLK. WALL precut studs adjacent. Attach all
studs to poured columnblock with
1/2" x 8" 1-IIIti KwTk Bolts, or equal, at
ti 24" o.c-. Use Palm Beach County
3" x 3" x 1/4" steel ware at each
bolt.
EXIST.
------------ - °:--------=====7
- 3'0" A.F_F,
CLOSED POST TOP
4"x4"xl/4" STEEL POST WELDED
TO 10"xl0"xl/2" STEEL BASE
PLATE
(4) 1/2"x4" REDHEADS W/ 2 1/2"
EMBEDMENT INTO CONC. FL.
I I"II, 1111I41 i, II
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
ALL MANUFACTURES LABLES SHOWING
U FACTORS AND SHGC COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
ST. LU17 p"L � � Z
REVIEWED FOR INC D in>•j
DENIES{'ED B?'
DATE
PLANS AA'D P �IIT MUST
OR NO EySPECTIOY }Vny BEBEM DE ON dOB
4 99 =s®av
18" LONG '3 DOUELS o 24" O.G.
on ea. SIDE STAGGERED x
TRENCH WIDTH. DRILL 4 EPDXY
rc" INTO EDGE Of EXIST, SLAB
MID -DEPTH. I
03 BAR CONT. —J 6 MIL. VAPOR BARRIER ON
COMPACTED e TREATED FILL.
�B ON GRADE PAiTC H[ 3/4"=19(
NOTE: SLAB PATCH FOR MECHANICAL TRENCHES - MATCH
EXISTING THICKNESS BUT NOT LESS THAN 4"
CUT OUT EXIST. SLAB
FOR NEW SHOWER,
5 1/2" RECESS.
(2 PLACES)
EXIST. SLAB
�9" x 9" THK'N,
EDGE W/ 1 04
BAR CONT.
SHOWER RECESS DETAIL
6'2"x3'S" F G PICTURE
W/ (2) 3T'XI'8" PROJECTION
BELOW
3' 4" x 3' 2"
AWN -MATCH
EXIST.
3,1"x5'3"
AWN. VIEW -
MATCH EXIST.
IFLD�I� ]PILE 114H, a 9 (099
GENERAL ADDITION NOTES:
-THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE
EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION
BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR).
,OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING
CONSTRUCTION.
EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE
VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR)
EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM
MATERIALS, ROOFING MATERIALS, FASCIAS, ETC.
*OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE
FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND
RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD.
-M.A. CORSON e ASSOC. INC. SHALL NOT BE LIABLE FOR ANY LOSS,
DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES.
AREA CALCULATIONS
EXIST. A/C Space 2480 S.F.
EXIST. Garage 592 S.F.
Total Under Roof 3012 S.F.
• Contractors to verify all
footages
• All areas are calculated to
outside dimensions.
WALL LEGEND
HOLLOW < HATCHED =
EXISTING WALL TO REMAIN
SOLID = NEW WALLS
DASHED = EXISTING
WALL TO BE REMO1w
ZLj V m o V
r6y
N V 0 O E 2
w N m 9 4 m N
Q a a p
O$ W s 0 9
`UN O� Os a m 0
Q3
OUF m-0 0Q) 3 3 m
•
U
4 z
Ww
Uw2
O� a�
t/1 F vi a g
EA b
N PC
00 0
z �N�
O °No
r
U C/1
N
r-I
• Y�1
•
DATE : 09/20/11
DRAWN BY: p. me
CHECIM) MC
REVISIONS
2�00/30/11 PER B.D.
l
u
Eq11.�Ell.11ll�U1�S.S1llL1C1L�C11llV 114°�vo
ELECTRICAL LEGEND
ELECTRICAL
SYMBOL
Can Light}
Can Light VP
w
Exhaust Fan
Pendant Ught
0
SWITCH-4-WAY
fluorescent light I x 4
outlet
lb
outlet 220v
6
outlet gfi
&
switch
switch 3 way
3
wall light Interior
Q
2011 NEC 210.12 (A)
Arc -Fault Circuit -Interrupter Protection.
Dwelling Units. All 120-volt, single phase, 15- and 20-ampere
branch circuits supplying outlets installed or devices In dwelling
unit kitchens, famlly rooms, dining rooms, living rooms, parlors,
libraries, dens, sun rooms, recreation rooms, closets, hallways,
laundy areas or almilar rooms or areas shall be protected by
any of the means described in the NEC 2011 210.12 (A)lU
through (6)
2011 NEC 406,12
Tamper -resistant receptacles In are required In dwelling unite in
all areas as specified In 2011 NEC 406.12(A) through (C).
All 125-volt, 15- and 20-ampere receptacles.
Florida Bullding Code 5th Edition (2014) Energy Conservation
C402.4.8 Recessed lighting.
Recessed Iwminaires Installed In the building thermal envelope
shall be eealmd to limit air leakage between conditioned and
uncondFtioned spaces, All recessed luminaires shall be IC -rated
and labeled as having an air leakage rate of not more than 2.0
cfm (0.344 L//e) when tested In accordance with ASTM E 283 at
a 1.51 psf (Ilk Pa) pressure differential. All recessed luminaires
shall be sealed with a gasket or caulk between the housing and
interior wall or celling covering,
0
11
File
e �vGpY
d
DATE : 05/20/17
DRAWN BY: ps m�
CHECKED : Mc
REVISIONS :
4&10/30/I1 PER B.D.