HomeMy WebLinkAboutBuilding plans.BUILDINS DATA E DESIGN PRESSURE SCHEDULE PROJECT/NAME SHEARER RESIDENCE M.A. CORSON E ADDRESS: zoos N,w. LAUREL oAK LANE ARCHITECT 11 ASSOCIATES, INC, PALM CITY, FLORIDA ALL PRESSURES CALCULATED WITH THE FOLLOWING: I. WIND LOADS BASED ON FLA. BUILDING CODE 2014 8, WALL ZONE (PSF): 4) +42.4 / -46.0 (5TH EDITION) k ASCE 1-10, AND 2011 N.E.C. 5) +42.4 / -56.1 2. BUILDING DESIGNED AS: ENCLOSED OPEN 9, GARAGE DOOR (PSF): N/A 3, MEAN BUILDING HEIGHT: 13 FT, ROOF PITCH: 5 /12 10, LOADS: FLOOR 60 PSF INTERNAL PRESSURE COEFICIENT +/- : 0.18 ROOF/DEAD 15 PSF ROOF LIVE 30 PSF 4, WIDTH OF END ZONE: 4' II, SHEAR WALLS CONSIDERED FOR STRUCTURE? WIND SPEED: 1-10 MPH 3 SECOND GUST YES X NO 5, RISK CATEGORY I -I. ASCE 1 12. CONTINUOUS LOAD PATH PROVIDED? F.B.C. TABLE 1604.5 II YES X NO 6. EXPOSURE CATEGORY: C ADJUSTMENT FACTOR: 1.45 13, ARE COMPONENT t CLADDING DETAILS PROVIDED? i. COMPONENTS < CLADDINGx WIND PRESSURE ON: YES X NO ROOF ZONE (PSF): U +24.5 / -38.9 14. SOIL BEARING CAPACITY: 2500 PSF 2) +24.5 / -61.8 3) +24.5 / -100.2 PRESUMPTIVE:_BY TEST: X 15, TYPE CONSTRUCTION (TABLE 601) (IS -ALL ZONES CALCULATED FOR WORST CASE SCENARIO, CIO S.F. EFFECTIVE WIND AREA) $TI—I EDITION FL. $UILDING CODE (2014) FOR EXISTING BUILDINGS SUMMARY: THE ALTERATION AREA HAS BEEN DESIGNED TO: LEVEL 2 Section 502 Repairs of the 5th Edition FBC (2014) Existing Building less than 50% of the aggreregate area The lateral -force -resisting system of the existing structure Is adaquate to withstand any new lateral loads of the new addition per Section 801.E of the 5th Edition FBC (2014) Existing Buildings. • The existing residence has hardwired smoke alarms and the new addition shall be hardwired and Interconnected to the exist. system where accessible Per R314.3 5th Edition FBC (2014), THE ADDITION HAS BEEN DESIGNED TO: CHAPTER 8 Chapter 8 of the 5th Edition FBC (2014) Existing Buliding a 2014 FBC 4 CHAPTER 6 OF ASCE 1-14 TOP PLATE OR WOOD BM. - SEE PLANS ui : - I EXIST. -Pressure treated full length stud BLK. WALL against 8" x 16" column block, with precut studs adjacent. Attach all etude to poured column block with 1/2" x 8" H11tT Kwik 8olto, or equal, at 24" o.c.. Use Palm Beach County 3" x 3" x 114" steel washers at each - bolt. Pressure treated full lergth stud EXIST. against 8 x I6 column block, with BLK. WALL precut studs adjacent. Attach all studs to poured columnblock with 1/2" x 8" 1-IIIti KwTk Bolts, or equal, at ti 24" o.c-. Use Palm Beach County 3" x 3" x 1/4" steel ware at each bolt. EXIST. ------------ - °:--------=====7 - 3'0" A.F_F, CLOSED POST TOP 4"x4"xl/4" STEEL POST WELDED TO 10"xl0"xl/2" STEEL BASE PLATE (4) 1/2"x4" REDHEADS W/ 2 1/2" EMBEDMENT INTO CONC. FL. I I"II, 1111I41 i, II CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD ALL MANUFACTURES LABLES SHOWING U FACTORS AND SHGC COMPLIANCE WITH FBC ENERGY CODE MUST REMAIN ON ALL DOORS AND WINDOWS UNTIL INSPECTIONS ARE APPROVED THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ST. LU17 p"L � � Z REVIEWED FOR INC D in>•j DENIES{'ED B?' DATE PLANS AA'D P �IIT MUST OR NO EySPECTIOY }Vny BEBEM DE ON dOB 4 99 =s®av 18" LONG '3 DOUELS o 24" O.G. on ea. SIDE STAGGERED x TRENCH WIDTH. DRILL 4 EPDXY rc" INTO EDGE Of EXIST, SLAB MID -DEPTH. I 03 BAR CONT. —J 6 MIL. VAPOR BARRIER ON COMPACTED e TREATED FILL. �B ON GRADE PAiTC H[ 3/4"=19( NOTE: SLAB PATCH FOR MECHANICAL TRENCHES - MATCH EXISTING THICKNESS BUT NOT LESS THAN 4" CUT OUT EXIST. SLAB FOR NEW SHOWER, 5 1/2" RECESS. (2 PLACES) EXIST. SLAB �9" x 9" THK'N, EDGE W/ 1 04 BAR CONT. SHOWER RECESS DETAIL 6'2"x3'S" F G PICTURE W/ (2) 3T'XI'8" PROJECTION BELOW 3' 4" x 3' 2" AWN -MATCH EXIST. 3,1"x5'3" AWN. VIEW - MATCH EXIST. IFLD�I� ]PILE 114H, a 9 (099 GENERAL ADDITION NOTES: -THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR). ,OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION. EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM MATERIALS, ROOFING MATERIALS, FASCIAS, ETC. *OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD. -M.A. CORSON e ASSOC. INC. SHALL NOT BE LIABLE FOR ANY LOSS, DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES. AREA CALCULATIONS EXIST. A/C Space 2480 S.F. EXIST. Garage 592 S.F. Total Under Roof 3012 S.F. • Contractors to verify all footages • All areas are calculated to outside dimensions. WALL LEGEND HOLLOW < HATCHED = EXISTING WALL TO REMAIN SOLID = NEW WALLS DASHED = EXISTING WALL TO BE REMO1w ZLj V m o V r6y N V 0 O E 2 w N m 9 4 m N Q a a p O$ W s 0 9 `UN O� Os a m 0 Q3 OUF m-0 0Q) 3 3 m • U 4 z Ww Uw2 O� a� t/1 F vi a g EA b N PC 00 0 z �N� O °No r U C/1 N r-I • Y�1 • DATE : 09/20/11 DRAWN BY: p. me CHECIM) MC REVISIONS 2�00/30/11 PER B.D. l u Eq11.�Ell.11ll�U1�S.S1llL1C1L�C11llV 114°�vo ELECTRICAL LEGEND ELECTRICAL SYMBOL Can Light} Can Light VP w Exhaust Fan Pendant Ught 0 SWITCH-4-WAY fluorescent light I x 4 outlet lb outlet 220v 6 outlet gfi & switch switch 3 way 3 wall light Interior Q 2011 NEC 210.12 (A) Arc -Fault Circuit -Interrupter Protection. Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed or devices In dwelling unit kitchens, famlly rooms, dining rooms, living rooms, parlors, libraries, dens, sun rooms, recreation rooms, closets, hallways, laundy areas or almilar rooms or areas shall be protected by any of the means described in the NEC 2011 210.12 (A)lU through (6) 2011 NEC 406,12 Tamper -resistant receptacles In are required In dwelling unite in all areas as specified In 2011 NEC 406.12(A) through (C). All 125-volt, 15- and 20-ampere receptacles. Florida Bullding Code 5th Edition (2014) Energy Conservation C402.4.8 Recessed lighting. Recessed Iwminaires Installed In the building thermal envelope shall be eealmd to limit air leakage between conditioned and uncondFtioned spaces, All recessed luminaires shall be IC -rated and labeled as having an air leakage rate of not more than 2.0 cfm (0.344 L//e) when tested In accordance with ASTM E 283 at a 1.51 psf (Ilk Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and interior wall or celling covering, 0 11 File e �vGpY d DATE : 05/20/17 DRAWN BY: ps m� CHECKED : Mc REVISIONS : 4&10/30/I1 PER B.D.