HomeMy WebLinkAboutRevisions , chg impact windows, add slab off rear of home OFFICE USE ONLY:
I
DA'fE•FILED: � 1 - EERMIT:#.._17-09-028:7...
REVISION_FEE: '1-5•_dd. RECEIPT#
PLANNING&DEVELOPMENT SERVICES
0 BUILDING&CODE REGULATION DIVISION
2360 VIRGINIA AVENUE
a FORT PIERCE,FL 34982-5652
(772)462-1553 FAX(772)462-1578
i
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/1
F�63 Dalia
ADDRESS:
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Changing to Impact Windows and Adding a 6x10 Slab Off Rear of Home
- i
-3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: ST.Lt,ICIE COUNTY CERT.#: 8898
BUSINESS NAME: orpora ion
QUALIFIERS N
ADDRESS: 0 South US Trw—y. 1 Suffe.402
CTTy; Port St. Lucie STATE: FE ZIP: 34
PHONE(DAYTIME): (7 72) 8 78-5513FAX: 772 878-7 56
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building C*ftg
ADDRESS: 8000 Southul .
CITY: r. ZIP: 34952
ti
PHONE: 2 - 878-7656
5. ARCHITECT/ENGINEER INFO I �
NAME: BRA EN&B1, A `
ADDRESS: y E!
CITY: STUART STATE: FE4V U k ZIP: 34996
PHONE(DAYTIME): (772)287-8258 FAX:
Revised07/22/2014 FH]e Copy
i �i ,
HEV1r%10N
i
7-1 ,
R5.CEIVED
Not Includ �� Tha Permit
MAR 2 718
ST, Lucie County, Permitting
33
G�
d•
. ` Can�� :• � �, �
e-7- h{
• � ... � tee.
i
A 0
Imo . �.
fl., Z``V
Ara„¢'
f
0.
-- 3 �f
File COO �� ���
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE, FL, Permit Number:
Owner: ` k\�0 1 p Jurisdiction:
Design Location: FL, Fort Pierce \ County:: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1432.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 1224.00 ftz
b.Frame-Wood,Adjacent R=11.0 208.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1753.00 ft2
6. Conditioned floor area above grade(ft2) 1753 b.N/A R= 1 ft2
Conditioned floor area below grade(ft2) 0 c. N/A R= ! ft2
11. Ducts R ft2
7. Windows(151.4 sgft.) Description Area a.Sup:Attic, Ret:Attic,AH:Attic 6 225
a. U-Factor: Sgl,U=0.63 111.36 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl,U=0.65 40.00 st kBtu/hr EfficiencySHGC: SHGC=0.21 n I 34.8 SEER:1i5.00
c. U-Factor: N/A
SHGC: 3, a ms kBtu/hr Efficiency
d. U-Factor: N/A 2 le` i t P 34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.85 ft. ,
Area Weighted Average SHGC: 0.239 1 •H t' s s
8. Floor Types (1753.0 sgft.) a.Electric Cap:40 gallons
I Insulation Area EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 53.83
Glass/Floor Area: 0.086 Total Baseline Loads: 53.85 PASS
i
I hereby certify that the plans and specifications covered by Review of the plans and O�THE ST,gT�
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance �,,,r =s; V0
with the Florida Energy Code. ti rnn a,�;,•,,'";,�O
PREPAR BY: Before construction is completed r�
DATE: `' this building will be inspected for �',II a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. COD WE Lev
OWNER/A BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
File COPY
4/16/2018 9:09 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE WINDSOR IM Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1753 Lot#
Owner Name: Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR
P.ermit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1753 14024
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes I Yes
2 WIC 63 504 No 0 1 No Yes Yes
3 MASTER BATH 56 448 No 0 1 Yes Yes Yes
4 M.BATH 61 488 No 0 1 Yes Yes Yes
5 LAUDRY 36 288 No 0 1 No Yes Yes
6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes
7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes
8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes
9 BATH 50 400 No 0 1 Yes Yes Yes
10 HALL 25 200 No 0 1 No Yes i Yes
11 FOYER 92 736 No 0 1 Yes Yes Yes
12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 _—_ 0 1 0
2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1' 0
3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ____ 0 1 0
4 Slab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 _—_ 0 1 0
5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 0 1 0
4/16/2018 9:09 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
i
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0
• i
7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0
i
8 Slab-On-Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ____ 0 1 0
9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft2 0 1 0
10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ____ 0 1 I 0
11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ____ 0 1 1 0
12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ____ 0 1 0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. de
Yp (deg)
i
1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1753 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood
2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood
3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood
4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood
5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood
6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood
7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood
8 Under Attic(Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood
9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood
10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood
11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood
12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood
I
WALLS
Adjacent S ace Cavity Width Height Sheathing Framing Solar Below
P _ o
1 NE=>W Exterior Concrete Block-Ext InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0 5 0
2 SW=>E Exterior Concrete Block-Ext In4dASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0
3 NW=>S Exterior Concrete Block-Ext InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0
4 NE=>W Exterior Concrete Block-Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
4/16/2018 9:09 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
I
I
FORM R405-2017
i WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
5 NE=>W Exterior Concrete Block-Ext InsuM.BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0
_ 6 NE=>W Exterior Concrete Block-Ext Ind3ffDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0
7 SW=>E Exterior Concrete Block-Ext IndXNING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0
_ 8 NW=>S Exterior Concrete Block-Ext In9INING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0
I
_ 9 SW=>E Exterior Concrete Block-Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0
i
10 NE=>W Exterior Concrete Block-Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0
11 SE=>N Exterior Concrete Block-Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0
12 SW=>E Exterior Concrete Block-Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
13 NE=>W Exterior Concrete Block-Ext InfiffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0
14 SW=>E Exterior Concrete Block-Ext IndMDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0
I
15 N=>SW Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0
i
DOORS
I
# Ornt Door Type Space Storms U-Value Width Height Area
YP P 9 ea
Ft In Ft In
1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 NW=>S 3 Metal Low-E Single Yes 0.63 0.25 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in None i None
3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in None None
4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft2 1 ft 0 in 1 ft 4 in None None
5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in None None
6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 806 ft2 806 ft2 26 ft 8 ft 11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7
, I
I
4/16/2018 9:09 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
HEATING SYSTEM
F;
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
I
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None
I
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
----Supply-- —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool
1 Attic 6 225 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr May X Jun X Jul X Aug Se Oct Nov Dec
Heatin Jan HFeb Mar Apr E May f Jun 4 Jul f Au jXj
Sep Oct Nov DecVentin Jan Feb X Mar [X]A r [ Ma [ Jun [ Jul [ Au Se [X]Oct H
Novi Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 781 78
I
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68, 68
PM 68 68 68 68 68 68 68 68 68 68 66' 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 i 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
I
I
I
I
4/16/2018 9:09 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE.WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT. PIERCE,AFL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with
sealed. a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed. minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, in
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wmr*ng-
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to-the sub-floor or drywall. j
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire ls�r* cover plates and walls or cell
a.In addition,inspection of log walls shall be in accordance with the provisions of[CC-400.
4/16/2018 9:09 PM EnergyGauge(D USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
I '
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The:lower the EnergyPerformance Index, the more efficient the home.
THE WINDSOR, FT. PIERCE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul, Exterior R=4.1 1224.00 ft2
b.Frame-Wood,Adjacent R=11.0 208.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1753.00 ft2
6. Conditioned floor area(ft2) 1753 b.N/A R= ft2
2 '
7. Windows- Description, Area 11. .N/Aucts R_ R ft2
a. U-Factor: Sgl, U=0.63 111.36 ft2 SHGC: SHGC=0.25 a.Sup:Attic, Ret:Attic,AH:Attic 6 225
b. U-Factor: Sgl,U=0.65 40.00 ft2
SHGC: SHGC=0.21 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 .
Area Weighted Average SHGC: 0.239
8. Floor Types Insulation Area 14.Hot water systems
2 a. Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 EF:0.97
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits stat
I certify that this home has complied with the Florida Energy Efficiency Code for Building ES
Construction through the above energy saving features which will be installed (or exceeded) .�,0��H _rA'T�o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �<vQ`,,,`''�j'
based on installed Code compliant features.
Builder Signature: - Date:
Address of New Home:\-�\U '7:5 � City/FL Zip
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
I
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2018 9:09 PM EnergyGauge@ USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
I
I
i