HomeMy WebLinkAboutbuilding permitGulf Coast Supply and MFG 5v Crimp Metal roofing FL WIL51.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1,25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
b/ts LhICK cuL coral
finished stucco bands RIGHT ELEVATION
SCALE: 1/4' = 1'-0'
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
4 1 SLOPE
9oor
ELL\/A7lCN N07ES:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11151.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM ID(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two sta gered rows 12" o.c. in field. Attach
�/ U t.rllt & I.UL t.vl al SLUGGo on typicai concrete
Finished stucco bands block construction
REAR ELEVATION
- Overhangs at 1'-0" unless otherwise noted on Roof Plan
- Roof pitch at 4:12 unless otherwise noted
- Ang changes to this plan shall be submitted to the architect
for approval In writing prior to starting construction.
- Return ALL Stucco Bands Into Window or Door.
SCALE: 1/4" = 1'-0"
4T�D -off/(
LUC U`.Ty n -TI.nTNf. p1`'fgrn-'j
;VIEWED FOR LA. CE
;VILIJEDBY >Lvcy
NE
ANS AND PERMIT ATUST BE KEP {ON JOB
1 NO INSPECTION WILL BE MADE.
/8" thick x 8"w cut
)ral finished stucco bands
ALL MANUFACTURES LQ81 ES SHOWING
U FACTORS AND SHGC COMPLIANCE
WRH F8C ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
71pNS ARE APPROVED
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c, max spacing over ASTM 0
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails�Y
spaced 6" a.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
4 [SLOPE_��
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12" 12„
8'-1" T.O.B. H ®®®® F
12" `
o.H 5/8" thick x 8"w cut
coral finished stucco bandH. 5/8" thick x 8"W cut ®®®
®' s ® coral finished stucco bands � ❑ �a IU
3 3 ®®ICI
5/8" thick light textured
stucco on typical concrete
= /ick light textureblock construction yara a Finished- Finished Floor ---------------
--------------------------------- - - - - -- -0-4 A.F.F. 8" thick
stucco on typical concrete
block construction
LEFT ELEVATION FRONT ELE\✓ATION
SCALE: 1/4" = 1'-0' SCALE: 1/4" = 1'-0'
Product Approval Submittal Affidavit
Opening Schedule Swing Doors. Overhead Doors, Sliding Doors,
Windows & Skylights
Opening
Type
NUMBER
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
TEST
t
Da a
Design Pressure
of Approved Tests
1,2,3
t4
FLU 11499.2
Single Hung
Series 185
MI Windows
and doors
i x tlyfcona uIyI mlrI p n ton at mnx
on eac� corner end L o.c. ChereaPter through PT �uck Into wild
Poled CMU wall mairmaeimg min 2.5" edge distance m strict adherence
to the product approvaL
+ 60 psf
A
IG-0330.02
Overhead
Garage Door
Model 824/811
9'-4" max Width
IL'-O" max height
DAB
mats % aC to coricrab ac wall, , a ce sit
n s5 biz varc song s/e• x L• Hilo HLC sleeve snahars et a e.c.
eh L225' yy h sic. a edge dutanea. Install treek to buck
np (I) 5/G' x Sfa�t/utl th sad ley wrew m each bracket mel tteimny
min or IS• ad" dmtenca - GC to atrmty adhere to product atairma
pproval
rovda l/IL' weir an idler theirs.
10-9-21
+ 50.0/-6o.0 Sf
p
B
FLU 16414.1
Fiberglass
Pro/
Smooth Pro
Jeld-Wen
Elco 1/4" dia. tapcon with min 1.25" embedment at 3" max
from corners and 11.5" o.c. max thereafter in head and jambs.
+ 50.0 PSF
C
FLU 15332.2
Sliding Glass
Door
Series 420
Mi Windows
and doors
om eac% corner end 'F2 3poa all �ou�Is row tfiereefter«through max.
PT Buck Into solid filled CMU wall maintaining min 2.5' edge distance
in strict adherence to the product approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
Ea spuction
Date
Design Pressure
of Approved Tests
Mullions
FLU 15353.8
CM-18531
Vertical mullion
j (1 Windows
and doors
For CMU use (2) I/4° x 2 3/4" Leptons with min I I/4" embedment
pen
etration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25" lF tapping scrswa per clip as shown in product approval.
se
+
_ 118.9 PSF
Roof
FLU 11651.12
SV Crimp
Metal Roofing
Gulf Coast Supply
and manufacturing
2! ja. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
w screws with self sealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" and
laps fastened with corrosion resistant tin caps and with 1.29" ring shank nails
spaced V o.c. at all laps and two staggered rows 12" c.c. in field. Attach
deck to trusses using attachment detail on roof plan
- IOB.S PSF
Siding
Stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vin I Soffit
y
Kagcan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
.12' die. x 1.5" Iona rina shank nil /dia. head -
+55.0/-35.0 PSF
Hurricane 24 Gauge Global Protection
Fin 15016.2 Products LLC
Panels Storm Panels
Install using 1/2" die. solid set lead anchors with 114" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
± 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record
2" x 4" top plate
base -board
Interior Norl-Bearin
1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at W' o.c.
2" x 4" P.T. bottom plate
4" concrete slab with fibermesh OR
CxC #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Partition
nts
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
5/8" thick x 8"w cut
coral finished stucco bands
Finish Columns with
5/8" thick cut coral
finished stucco bands
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Categorg: II Wind Velocity: IL5 mph ultimate
Mean Roof Height: II'-p" Roof Pitch: 4.12
Internal Pressure Coefficient: ±OJB
SubJectabilitg to damage from: Weathering: Negligible Termites: VerLl HeavLl
Width of hoof End Zone: 3'-4" Wind Speed: 165 mph ultimate
Wind Exposure Classification: C 1.21 x O.L = 0.12L
Ad,lustrmnt factor for Exposure Height: ASO design
Load C,,,ibination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.1.DL+O.613L
Components t Cladding Wind Pressure (NET) Roof Zone. I. +20.4/-32.4 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.4/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 psf
Components t Cladding Wind Pressure (NET) on Garage Door. +32.0/-40.3psf
Shear Walls Considered for Structure? Yes
Continucts Load Path Provided? es
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X Bg Test: psi
This Building Shall Have the Following.
APfROV£D SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: _3'1 pal' ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: --ifi- oaf FLOOR DEAD LOAD: 10 oaf
JOB ADDRESS:
ITCH
E-] = Roof Zone I
Walls Zone 4
En = Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
Braden it Braden AIA, FA
Architects - Planners
Wginne Building p COr .
CLT E
Date Drawn
8_9-11
Revisions
Sheet
Comm #
411 S.E. Coconut Avenue
BTel (l-12) 281-8258
T h e G� r a n d Carlton
EF
Drawn by:
1
2 2
:
C.C.U.
•
Fax : (112) 28�1-8283
Spanish Lakes
Checked by:
E-mail: bradenaia comcast. net
Stuart. FL 34994 #AAC000032
St. Lucre Countg Florida
OF 5
FLOOR FLAN IHI
CRASH POST DETAIL
TYPICAL MOTES: SCALE. I/4" = I'-O" N.T.S.
I. Contractor to verify ALL notes and dimensions prior to 36" high by 4" diameter
steel crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts Into
3. ALL Lumber to be used as Beam, Rafters, etc.,. to have slab (3/8"t 50 ksi steel plate)
a minimum 1,400 P.S.I. fiber stress. C
4. No dissimilar metals to touch. 2y2" 2r2"
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete,
ALL Concrete used for vertical filled cells, coat. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix " ,3/e" 0 2'r;'
6. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R-102.3.5. 2r2"
-1 Al w d in c t t th t h If b t t d 0 0
00on ac wl contra e s a e pressure rea e .
8. ALL wall dimensions are nominal and not finished Wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10. Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
2/"
2r2"
12. Lowest finished floor to be set by Governing Building Department
6"
surveyor to set in field.
13. Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min, rated door
w.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 per
FBC R302.9.1
16. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450
per FBC R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
I" x 0 P.T. Buck nailed to
block with case hardened
materials exposed on the underside of the roof deck or on the attic walls shall comply
nails
prior to door attachment
with F.B.C. R316 - see permit info box of code edition
18. Gyypsum board material shall conform to ASTM C36, C�19, C4-15, C514, C630, C931
C'%0, C1002, C1047,C1111, Ci118, C1218, C1395, or C13% and shall be installed
according to the following: (FBC R-T02.3.5)
Drywall
Thickness
Location
Orientation
Member
Max. spacing
fasteners
Nall sizing options for
Spacing
of
installation of dr wall into
g
Maximum
wood framing members
2" x min. thickness
Nails
Screws
Ceiling
Perpendicular
24"
1"
12°
13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
OR
Walls
16
g^
I6"
0.080" dia. x 1 5/8" long with
Direction
15/64" head
OR
Gypsum board nail 0.086" dia.
x 15/8" with 9/32" head.
Ceiling
Perpendicular
24"
1„
12a
13ga 1 5/8" long with 19/64" head
OR
0.098' diameter x 1 3/8" long
annular -ringed or 6d cooler nail
e
OR
Walls
Either
I6"
8,
I6"
0.092" dia. xx 1 1/8" Ion 9 with
Direction
1/4" head
OR
Ggpsum board nail 0.0915" dia.
x I/8" with 19/64" head.
Install SGD thru buck Into
block with 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product a�prc
19. ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling a§semblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanyln smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with sell' sealing washer at 12" o.c. max spacing over ASTM 1)(type 2) 30 lb felt underlagment installed with min. 4' side laps and C end
laps fastened with corrosion resistant tin caps and with 1.29" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c, in field. Attach
deck to trusses us
rng attachment at on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss 12
with (10) IOd x I I/2" nails PRE-ENGINEERED TRUSSES
( 24" o.c.) supporting Max. 4 at 24"o.c. TYPICAL
181016s. uplift �\ (shop drawings by manufacturer)
Aluminum Drip;
Edge 4 Fascia
" \R-30 blown fiberglass
in bottom chord of trusses
2" x 6" Sub -Fascia
Kaycan full o vent vinyl sorrit installed
using 1/8" die shank x 15" long gals.
roofing nails with 3/8" dia. head per
product approval - see chart sheet #1
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (l) #5 bar cont, in each row. Substitute
precast lintel filled with concrete and (1) #S
bar cont. for bottom row over openings
1/2" drgwall over 1" x furring
strips at 16" o.c. with R4.1 Pi -toll
insulation on typical 8" Block walls
5/8" thick light textured
stucco on typical concrete
block construction
=
I
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" onl proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC RLO1.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
45 bar vert, w/
30" overlap
Fill cell with concrete and
at each filled cell
Wood
Base
(D #5 bar vert. (typical).
Max. spacing shall not exceed
48" unless otherwise noted
see Foundation plan notes for
spacing at openings
4" concrete slab with Fibermesh OR
6"xb" 410/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
Grade
TYPICAL SECTiON
14" x 14" Concrete footing
with (2) 05 bars cont. and 45
transverse bars at 48" o.c.
Scale : 1/2" = 1'-0"
Masonry Beam
Head
fixed door
sliding door
1 1/2"
BottomTrack t•�1
Sill
Sliding Door Deta11
At Masonry Wall NTS
AREA CALCULATIONS
Living A/C =
1-446
sq.
ft.
Front Porch =
141
sq,
ft.
Rear Porch =
200
sq.
ft.
Garage =
321
sq.
f t.
Total Under Roof=
2108
sq.
ft.
Total Cubic Ft =
11,568
2" VTR
JAL
I
I
I
2l' VTR
-'i
Masterr�Jib
Bath
I 2.
I
Lev. I
z I
Lay.
1' 2" VTR
W. AL
I I
2" I
shwr.
Kit. Sink
I
Kitchen 2 I
I
Lay.,4
3'
W.C.
Bath #2 shwr.
3„
C.O. To Septic
PLUNS NG RISER
I" x 6" P.T. Buck nailed to
block with case hardened malls
prior to door attachment ,
Masonry Wall
cal Flooring
Install SGD thru buck Into
block with 3/I6" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval Jamb
r
Window
Schedule
Mark
Size
Rough Open.
Window Description
PRESSURE ZONE
I.
4'-5%s"x 5'-3%'
54%s"x 63i,"
Single Hung
ZONE 4
2.
6'-23/e"x 5'-3 %"
15" x 63 %4"
Single Hung
ZONE 4
3.
2'-2" x V-2 1/2"
2"1%2"x 38%"
Single Hung
ZONE 4
4.
4'-5/a'x 4'-2%" 1
54/a'x 54Ys"
Single Hung
ZONE 4
ALL
Windows to be aluminum
windows w/ tint
and mullions per
elevations.
ALL
windows to withstand
pressures in permit info box on
sheet I
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturers
specs prior to construction
Door Schedule
Mark
EA
Size
Rough opening
Door Description
PRESSURE ZONE
9'-O" X 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X 6'-8"
41 %4"x 83%,"
Fiberglass Panel - Inswing
ZONE 4
C
6'-O" X 6'-8"
14" x 81 Frw 2" of rvav" "
Sliding Glass Door
ZONE 4
D
2'-0" X 6'-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81 %2"
E
2'-6" X C-8"
Solid Core - Wood
- 6-Panel
F
5'-0" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x 6'-8" x 1 %"
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X C-8"
Solid Core - Wood
- 6-Panel
2'-6" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
2'-8" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 91
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified by contractor
With manufacturers Specs prior to construction
Install windows thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at ambs and 20" o.c. max.
Exterior face at head and aid per product approval
of wall ---\ \ Buck to be 1" x 4" PT
I"x4" P.T. Buck nailed to
lock with case hardened nails
D e t a l l at w 1 n d ow S prior to window attachment
Braden i Braden AIA, FA
Architects - Planners
411 S.E. Coconut Avenue
Tel (112) 281-8268
Fax ; ('112) 281-8283
E-mail: bradenaia°comcast.net
Stuart, FL 3.4996 #AACOOOOS2
NTS
Wgnne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
34'-O"
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
12"
Exterior race
or wall -\
,12,E
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
1 1/4" penetration at 12" O.C. max
and 4" max from each corner thru
2" x 6" PT Buck
UeLall at L)OOr
41,
m
crews thru jamb into buck
ige and I5" o.cmax and
prior to door attachment
NTS
Date Drawn Revisions Sheet Comm it
5-9-11
GARAGE Drawn raven
LEFT by:
2. 12-2�
Checked by: File Copy
D.R.B. OF 6 _ _-
34-0"
STRUCTURAL MOTES.
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL 9.
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS 10. DESIGN LOADS ARE As FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI ROOF ( = .4-1 PSF
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS WIND VELLOCIOCI TY =PER PERMIT INFO BOX ON SHEET #I
EXPOSURE ="C"
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
II.
4
GROUND FLOOR SLAB TO BE A MINIMUM 4 THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
13
MACHINE COMPACTED TO A MINIMUM OF 2500 PSi IN AREA OF
BUILDING CONSTRUCTION
6-
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14
7-
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15
ATTENTION OF THE ARCHITECT.
16
8-
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
17
FCLAD/470N FLAN
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, t
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE iN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified In writing for revision
-4. Verify all recess thickness at showers, tile, etc.—
S. Contractor to provide filled cell with concrete and 1 45 bar Vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings upp to 5'—I1" wide.
Provide (2) filled cells on each side of openings from l' —O" to 9'-11i'
and Provide (3) filled cells on each side of openings from 10'—O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 2'" o.c. unless otherwise noted (see section)
�. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
I Contractor to provide for soil test prior to construction and provide
a copy of Soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade (0, meeting ASTM A-1� and
A-35 specifications. ALL Anchors to be A-30-1 steel.
`l. Provide a minimum Of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
46 bar vert. w/
30" overlap -
at each filled cell
° TYPICAL
CTIONS
4" concrete slab with fibermesh OR
6"x6" #10/lo wWM on 10 mil Visqueen over
clean compacted termite treated fill
Grade
14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
14"
f 1 TYPICAL FOOTING DETAIL _
SCALE 1/2" = I'-O"
4" concrete slab with fibermesh OR
6 x6 910/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
45 bar cont.
Step per
„o foundation plan
N_
0„ '(2) #5 bars cont. bottom steel
12"
DETAIL AT GARAGE STEPDOWN
12" x 12" concrete column
block filled with concrete
and (2) #'I bars vert. tied
Into lintels above
Top of footer
IV below finished floor
"717
SCALE 1/2" = 1'-0"
Verifg house slab
height in field
10
W A- M I a Ms..
mii —�—il
30" rl
COLUMN FOOTING DETAIL
30"x30"xl6" concrete
column footing with (4)
#5 bars each way
Thicken edge to 8"x8"
with concrete and
one U5 bar continuous
GRADE
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
Inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4" concrete slab with fibermesh OR
VxV 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
PORCH SLAB EDGE DETAIL
SCALE 1/2" = I'-
45 bar vert. w/
30' overlap
at each filled cell
Adjust curb height
based on gar. floor
slope_
#5 bar in curb \
11
Aff
11=
14"
BEE TYPICAL
SECTIONS
4" concrete slab with fibermesh OR
6"xC #10/10 WWM on 10 mil Visqueen over
clean compacted/termite treated fill
i -M
iI 14"w x 14"d concrete monolithic
footing with (2) #S bars cont.
GARAGE CURB DETAIL
2" x 6"
PT wood secured
with \
3/8"dia.
x 6" anchor bolt
at 18" o.c.
overhead door track secured to
wood
jamb per manufacturer's product
approval
Garage
Door Jamb
Detail
GARAGE
DOOR TO WITHSTAND PRESSURES STATED
NTS
IN PERMIT
INFO BOX ON
SHEET U1. SEE PRODUCT
`
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Colunn With One
45 From Footing To Tie Beam
Conc, Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden It Braden AIA, FA
Architects — Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (1712) 281-8283
E-mail: bradenaia8comca5t.net
Stuart. FL 34994 #AAC000032
20'-0"
00
00
y i
001 00
°
F
Filled cell under
FI girder above
I
24"
Rear Patio/Slab r
I
r J
to
be poured separate
from the house slab.
m
I
I
Thicken footing to
I FI
24"w x 14"d x 24"L
under filled cell
I
I
a
I
under girder bearing.
°
0 ,
0
0E
u
U
I
Rear Patio/Slab to
be flush with bottom of
i-N
sliding door recess.
Slope I/2"
I F=
I
h-
I C-
I
I
I F_
Ii.
D
I
FI
o
32'-8"
H.B.
I
I
I ^
D o
4" concrete slab
Cx6" 410/10 WWM on
with fiber nesh OR
6 mil V squeen over
I O
clean compacted
termite tr
ated fill
I
°I
Ic
I
F-
-�
I
I
F-
I
I
(V
I
0
Q
H.B.
� It
Or—
I
Steel Ballard
v
if
#1
F5
4"m
filled w/
Concrete® I
\- Wj YIIVII
m I REW, Nllr. i I fti,:lQUIRCIO
I I
I
ndv i
Ems
.!
to
I
L
�.9 E
FI
I
DI
3r_a
°o
Ito
❑❑�
-,I
ar�
I
m\P
\
O o
��a
\
I
UO °
= I
\
FI
I
goy
F51---_--_---Jo
F5
zx a
W I
O
O 00
n i
Vr Is
l o°
-
I
O
F4
O
recess for
�
r__ I
l
OL
00 00
Garage Door
----�0—1
DD 00
---
o °———
— — — —
-- °
°
o
J
F
6'-2,�
F
inn inn
--111-611
Wgnne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
witIhL conLete VaIn{.dI G(Y2G ) 4.#V1IYbars V1V..ertI.IGtYi qz
into lintels above
A
n
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
1211W
X 12"0
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
F
30"
x 30" x 16"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WITH I #5 BAR CONTINUOUS
FS
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB 9 0'-0"
Date Drawn : Revisions Sheet
5-9-11 Comm #
GARAGE Drawn bg: /
LEFT I2- 2 (
Checked by:
D.R.B_ OF 5
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nail Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" CDX Plgwood
4. Use nails or screws based on pressure for root stated
in permit info box on these pans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone 1
6
6
Sd ring shank
45 psf
Zone 2
.4
6"
8d ring shank
76 psf
Zone 3
14"
41'
Bid ring shank
84 psf
** Zone 3a
6"
6"
#8 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Verify with Plan
12 "x 12"
Column Block
Rebar
Rebar 48 Bar Dia.
Min. Overlap
to Lintel Attachment
NTS
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel. 'iz,-
Provide Cast -Crete .
81,18-OB/OT precast -
lintel set in mortar
Min. 8" Bearing - -
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
Provide PT Buck
attached per jamb
etals into filled a
4" Pre -cast
Sill
r
Filled Cell
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
'filled cell steel into continuous
footer steel.
Scale: I/2" = I'-o"
CBS WALL
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vert. leg of
truss with IOd x 1.5' nails at 4" o.c.
Install Simpson MGT into wall using
5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
3LOCKING DETAIL
)ER STRAPPING.:
TER BEARING, POINT
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tyype 2 felt paper using 8d Halls. Substrate
to be 19/32' CDX Plywood nailed at G" o.c, in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #1101.12
2( ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlayment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Additional Precast Lintel
#5 bare _
if CLEAR
Lintel
Length
Bar
Length
Clear
Span
"A"
Bars
Bars
'-L"
2,#3
none
2'-0"
2'-8"
3'-C
3'-4"
2'-2"
2,#3
none
BPS-OB/IT 8F8-IB/IT BPS-IB/2T
Additional
3'-10"
2'-8"
2,#3
none
#5 bars •=
r "`!r`
3'-2"
4'-6"
4'-41,
2,#3
none
CLEAR`a'%
•�a^;T One Row of "H"
5'-4"
5'-2"
2,43
none
Block Above f'::
4O"
5'-8"
4'-6"
2,1t4
none
Precast Lintel
5'-4"
2,#4
none
""'.
Additional i
i 35 bars i
-'--' `----"6'-21,
2,45
none
BFIL-IB/IT BFIL-8/2T
2,45
none
NOTES
ALL reinforcing steel Is grade 6O.
L min. coverage of steel=l.5"
2. min. bearing required sea. 1
3. standard for rernf. steel=ASTM ALIS
TYPICAL LINTEL SECTION
l PRECAST CONCRETE )
o
LINTEL SCHEDULE
Mark
Window
or D
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
Bottom
Steel
Size
Top
steel
Sim
May
Gravity
Load
(PLF)
Max
Uplift
Load
(PLF)
Max
Lateral
Load
(PLF)
L22
T-2"
V-L"
8111
1
#5
30L9
1569
1024
L31
T-L"
4'-0"
8FB-OB/IT
1
#S
2561
130
10
L45
4'-5"
5'-10"
are-OB/IT
I
no
1105
909
339
L50
V-O"
V-A"
BFB-OB/IT
1
#5
1238
635
121
LLO
L'-B"
T-L"
8P8-OB/IT
1
#5
1011
121
534
LBO
8'-0"
9'-4"
8F8-IB/2T
I
#5
1 2
#5
152
591
1 512
L90
9'-O"
10'-L'
8F8-IB/2T
1
#5
2
#5
443
530
401
L908
9'-0"
10'-L"
BFIL-IB/2T
ONE
1
#5
2
#5
1533
1193
401
1I00
10'-O"
II'-4"
8F8-IB/2T
1
#5
2
#6
582
494
452
LIOOB
10'-O"
II'-4"
eFIL-IB/2T
ONE
1
#5
2
#5
1366
1028
452
L120
12'-0"
13'-4"
8F8-IB/2T
1
#5
2
#i
1 411
428
324
L120B
12'-0"
IV-4"
BPIL-IB/2T
ONE
1
#5
2
#5
1015
110
324
L140
14'-O"
15'-4"
BFIL-I15/2T
ONE
I
2
#5
1250
409
259
LILO
IC -Ow
i1'-4"
8F8-IB/2T
I
#5
%
2
#5
300
192
194
LILOB
IL'-O"
11'-4"
BFIL-IB/2T
ONE
I
#5
2
#£
950
5o0
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION. HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSF-D.
12
Simpson HETA 20 or equal 4
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails
( 24" o.c.) supporting Max
18101bs. uplift
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd ds
at each web
Aluminum Drip
Edge it Fascia 1/2" thrc stucco on 3/8" hi —rib lath
attached to horizontal and vertical wood
12" framing with nails or staples to provide
no less than 1-3/4" penetration into
2" x L" Sub-Fascl horizontal wood framing and 3/4" penetration
into vertical wood framing members
Kai full o vent vinyyl soffit installed
using 1/8" dia shank x 15" long gale.
rooring nails with 3/8" dia. head per
product approval — see chart sheet #1
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied-�
into lintels above
thicken edge to 8"x8"
with concrete and
one #5 bar continuous
BEYOND
Top of Tooter
It below finished floor
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Poured Cm
concrete b
Poured Concrete
concrete block a
Concrete f
Manufactvai
chore Per
space
lax.
or
J
v
Flush Mounted Shutter Detail
Aluminum Panel
Sizes per manufacturer
— Be. Tgpical Stud Qatar]
7/8' x 3/32' Wing Nut w/
appropriate washer and spacing
per manufacturer's Details
5
OL3'
u
.09x"
ni
oo :
a P-
Stud Detail
Stud w/ Dra Cast Zinc Nra
Nickel Plated Wing Nut
nts
Brace Gable end
with 2" x 4" SYP 3t2
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
s 24"o.c. TYPICAL
( shop drawings by manufacturer )
0
Q
LU
U)
Ul
�
4L
X
a3
�
s
O�
rn
N v
-s
Qs
Z .
a
L
a
�
T
+
U) e)
O to
N
U
oJCL
Er_
°D
O
N u
N
L
L
�
Eulc
Brace Gable end
with 2" x 4" SYP #2 min.
8rt back nailed to bottoms
of top chords using (2) IOd
nails at each truss
R-30 blown fiberglass
in bottom chord of trusses
I
-1/2" drywall with smooth finish Co
Two rows of beam block filled with concrete
_and lU #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar Cont. for bottom row over openings
1/2" dryywall over I" x furringg
strips at 14" o.c. with R4.1 fi-foil -
-insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar points shall comply with FBC R601.2.1:
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Strap truss to wall
using Simpson MGT with
Simpson
HETA 20
5/8' dia.
threaded
rod with min 12" embedment
hurricane anchor
at each truss
into beam
(22) IOd
truss leg
either wet
nails into
per detail
set or in epoxy with
truss. Add blocking to
on this sheet
( 24I, o.C.)
HETA 20 1810
supporting Max.
pp g
lbs. ut)llft
OAF
IS
For
OVA ARA
M&MAIN. N
AA
FIR
Aje AA
Y
qkm
Nis
WOO
I
Ir/Ald
I
HETA 20
O
F-
O
Q
F-
w
� X
L to
4J1:
r
O � m
CV
Q o
n.
L d
-ic u)
V
to o0
E_ L
N U CV
L
L �
L
O
LU
Fill cell with concrete and
(U #5 bar veil. (typicaU.
O
ROOF
/`
Max. spacing shall not exceed
/4
Wood
48" unless otherwise noted
sseeaecfogunadatio notes for
— OVERHANGS
AT I'—O" UNLESS OTHERWISE
NOTED ON THIS SHEET
elan
opeJ ngs
4" concrete slab with fibermesh OR
— ROOF PITCH
AT 4:12 UNLESS OTHERWISE
NOTED ON THIS SHEET
6"xL" #10/10 WWM on L mil Visqueen over
— TRUSS SHOP
DRAWINGS TO BE PROVIDED
BY MANUFACTURER
clean compacted termite treated fill
— ANY CHANGES TO THIS PLAN SHALL BE
SUBMITTED TO THE
III IIII IIII- 1-llil-iir�
III 1111 I l l i- FI
14"
till ll�1 ���i= 3 T4plcal Section at Front fi orch
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
PANEL
"A"
Pales
BR
Load
Wire
Description
circ#
arc#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
3o
2
3
q
2
30
4.5 kw
#l0
10 gal. water HTR
5
6
Range
#6
12.0 kw
So
2
a
1
20
1.8 kw
#12
Pump
9
10
Orer
410
5.0 kw
30
2
II
12
1
20
LS kw
#12
13
14
1 Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
IS
IL
Refrigerator
412
1.2 kw
20
I
1
20
1.5 kw
#12
Kitchen S.A.C.
n
18
Recepts
412
20
I
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
L2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
I
1
20
0.81 kw
412
Garage Door Opener
23
24
Recepts
412
20
I
1
20
[A kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
I
1
20
#12
General Lighting
29
30
Recepts
#12
-
20
I
1
20
#12
General Lighting
31
32
Recepts
#12
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
20
1
1
20
#12
General Lighting
35
36
Bathroom GFI
#12
-
20
1
1
20
412
Smoke Detectors
31
38
General Lighting
412
-
20
1
1
20
#12
Bathroom GFI
39
40
General Lighting
312
20
1
spare
41
42
share
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (3 watts sq. ft)
Small, ,Appliance, Circuits) ...... .. ................
Range.........................................................
Refrigerator ................................. I .................
.Microwave.
..........v..e.....................................................
D.ish .W..asher.200
............................................................
Clothes Washer ..............................
Clothes..Dryer.................................
Water Heater
.................................... ....................
Water. ,Pump.... ............................
.Garage Door Opener. _ . _ ..
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1200
11200
1
1,500
1,500
I
1
1,200
I
1200
1,200
1
5,000
5.000
I
4,500
4,500
I
1800
1,800
I
810
1 810
Total Watts
31,415
First 10000 Watts 8100%
1
10,000
10,000
Remainder 21,415 940%
1
O
10,944
Electric Heat or A/C 10,000 1365%
1
10,000
10,000
Calculated Load
Watts
30,944
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
Sy
Double Pole Switch
®
Eyeball Recessed
P1B
Push Button Switch
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
O-
Wall Mounted Light
P rc
ground fault circuit
interrupter
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-M-1
Carbon Monoxide Detector
Flood Light
TO
Thermostat
m
Electrical Panel
®
Central Vac
rJ
Electrical Meter
®
Smoke Detector
Ceiling fan
Fv
Television Jack
1
Telephone Jack
AC oiso
A/C Disconnect
®
1 x 4 Florescent Light
®
2 x 4 Florescent Light
KR
Speaker Hook -Up
El
Intercom
®= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
I. Use copper wire only, no aluminum_
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
5. ALL bath and kitchen receptacles to be GFI protected.
4, ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMIL02
10. A/C Refrigerant lines that are run thru slabs must be
sleeved in PVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed by a licensed electrical
contractor, the completed system shall be fully operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
Ile. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two gears from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
163 CFM
IOXIOX6
MASTER
BEDROOM
143 CFM
IOXIOx6
12xl2x9
B/A
�Lt - - - - - a I
12x12x9
B/A
PATIO/SLAB
I
I
CAR 1AT
ROOM
I
I
I
169 CFM Center Registers
on ceiling fan 149 CFM
IOXIOx I IOXIOxI
H.B. =CLOSE
8x4x4
I I
8X4x4 ----J 12" I
3 CFM -
Vent-thru ____ DINING
Soffit ,ATH ~� I ROOM
I � I
io. °
N
Ihs
ICI a
153 CFM
12x12x1
8x XC4F 1 `f " I _
� R7A1 18 FM
o ,4 T H
- - - 00 T 20K20
I
-- - -
- -
#I
I
I -22" x 54" ,"
r I IIL"
i Attic Access 1
p
L_ with fight- I Q 1 i 232 CFM
J l 12x6x1
iL - -ter_ va• J
150 Am L'=I
Meter Panel p
9X4x4 �`� SECOND
GARAGE 35 � � BEDROOM
12x12x8
�1 B/A
r----------------- i
I �
I j
I �
I i
COVERED
I i
PORCH
1 i
I I
I I
MECH/4NIC,4L L/4YOUT
SCALE: 1/-f" = I' -Oil
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical system shall be completely and effectively
grounded as required by the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected by others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RM1502
A/C disc.
150
42/0 Aluminum feed AMP
I V," Conduit PCB
A EL
��M TE
AHU
2" PVC ( FF`0
2" rigid service FPL Bare #6 copper wire
to #5 cont, hebar in slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
H.B.
Vent thru
Soffit
Braden t
Braden AAA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 281-8258
Fax
: (1-12) 281-8283
E-mail:
bradenaia8comcast.met
Stuart, FL
3499L #AAC000032
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
WP GFi
Install owlet
under disc. �
not shown or O
clarity
0
I
v
ELECTRIC/4L PL,4N
PATIO/SLAB
SOLE: 1/4" = I'-O"
Attic ventiric Calculations EBC 2309.1
Total Attic Space = 212-4 sq. ft.
Venting Ratio VISO = 1-4.16 sq, ft. required
Provide A Continuous Vented Soffit
Wgnne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
Post Light with /4 o
Photo call c
v�
E
w
0
N
a
Exhaust Duct
7hru Soffit
' Wire For
Front Post
Light
Date Drawn Revisions Sheet Comm #
6-9-11
GARAGE Drawn raven
LEFT by:
C.C.U.
Checked by: -_
D.R_B. OF 6
A LIFE SAFETY WARNING
This mbol identifies Life Safety Warnings that should be read
aive oecial attention by all persons installing trusses.
SPAGING NOTE
ALL TRUSSES ARE TO BE SET
AT 2'-0: ON CENTER
EXCEPT AS NOTED
MULTIPLE PLY TRUSSES MUST BE
TENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
GINEERING DRAWING TO DETERMINE
IF MULTIPLE PLY. A
M
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
Spanior less
1� / �6 degrees
i or
less
-- 1 /2 —►
lag !. re SPci approx.
REFER TO BCD
Truss r, u be set 1,, way It crane used -
Truss o,omple, your truss moy not notch.
Insist -e ooerotor sets truss this way-
30' to 60' Span A
Spreader Bar
tra9 , _ Approx 2/3 to
Line 1/2 of Span
REFER TO BCSI
iss must be set this way if crane used.
This is an exomple, truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. AL
R "A" ID I IF= R lV OT E
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
U REPRESENTS A HANGER
Carrying Girder
For Truss to Truss
Connections see
hanger/connectorTNailsbe as
de tabs of
schedule in engineeringe nails.
package.
EAT PLATES BY CHAMBERS
INDICATES LOAD BEARING WALL
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-1"
ABOVE FINISHED FLOOR
12
4.00 F--
/ o,
M
T2�
set=1/4" heel=315116"
LUMB CUT END
x 4 Top Chord
WALL HEIGHT 8'-1"
TYPICAL END DETAIL
12
4.00 F--
6� '-1°
n 12 2.00
M
upset=11/4" heel=315/16"
PLUMB CUT END
1'
2 x 4 Top Chord
WALL HEIGHT 8'-l"
END DETAIL: A
ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 17' - 23' IN LENGTH
Do not stand on trusses until they are braced pe- BCSI & properly nailed to straps & hangers
GARAGE LEFT
GARAGE RIGHT
FABRICATION AGREEMENT' -
1R XMS CAWW 98 aTAMW UWLTM AGM!b lJIT O OMM i RE WOM
T4ie fmWf dsacrlptbn d1M properbwMp tM baeaswa M betaMd to :
TIa mdarawfdsp mlta
7 :1Ywtei we be plods In d aoccacauser
M va lie trap p�o�aeyom
�rltdlUtrlsaol.wOgbic►deYmllrtvauixesdi pk N elfllatrin.p�'�"
: 2AJI tarrenebla 6lrle 1 fotl lore been ewaed bytta Irldelegld
1 IJldeia wrtbrt rtola b prwWed by oelabd and b Ctwrbre Tlw wlOb tan (1�
dmyi d daOvsry ffle andwalard aareae that In bedwhatres M beeyYjlwawad.b trr o d
lapetre eltialage dMcbwpe, dacha d d�ldi�' days It wNt31
4s.p14w wrmryshad byTFl A wreA.
DNery boJob elks. a In the Myeh'nepowbay b ntda tla his atr SUN" for
daMry. Cltalrlbers Tnm hp to mob sualoriybdaWnir Oa auteh/ydaajob ate
The "Etysr fa m�paablia'yrrddllatel delvmry e K T4vRM bm10
�iadeN
beaae job mte b riot pmwlW for deMy ar byet b Int pnpamd br deMay d banns.
QuysrYteepaabbb Tnm lot = ooeb due ball oortdara.'
0. pfke o crown h pelegreph 7 babes b etbJmd b gang r a dtwtpp are.nmde b
11di Ill A f60 perttcrr M for pvtrbrle may W drpd by Chrdtaa
T. TMa'k a PURCHASE ORUR to Chiertbea,Thas d ea wrm agreed ter or r
iMleerpri a rwaisib pfoe. Invcicm wa be nod. on deMy and lint of t lama a
delver modes may, be horde st edidNad dab-bt deNar If Iaryer comet
des wy of febdafed Lapp The urdralpad agree to pay Ctlerdiela.Tpas reoaniw
atlrllillefiebrt>o" -1 ioevertdprolardnot drlayands.142%permon01seydoe
diellp be added ford was not patdwtM Want.
. 0. Slpltahae or go' wywMw on tlrb shod owaauae aWmm t to d tenor farobl.
• a b coraNertglon of awnbmo Taw ederdr g croft for Ihb radedd as raakralpad
mtocrrdaerWY t p.m when due of any and d Mebbdpea owed to
gtanbera Taw br.wy arttlb r.oehele nrslerbl and da undombrod'agreea to pry aft
tla baman frrmrdfrl0 rut rwp bee, r dabd In psyneent for arabdd be alede by to
y'� slo MrR of my IApelpn oaneM. 9Ye apewrteR M Aame tumhhed hereunder
or 0aea fel lafelted b Irerat4 Nor pedb "m Oat a'te sple versa fbr any wrdt aram wa
b BBeatidA ftOde Coulb, Rwlaa
11. Dee4p resWieblalw am per -Nor nel Shndrd And RAVra vended ftdebbam On
Rmipare6aa se rt1r OcrrbCOW Using Me41 Pmb Cmrtecbd WoodTnaeae
ANSOrP" se Fr
'\ "
STONED
roPt nn a
Asproderb.rnmVi>sm"adpar'ECS!WIDpfewntillft,11, 9
IllyMpla ply trusses must be fastened lopether per enginosring
before ttwy am set faqurs to do ao can reiwltln roof cokspil
Ti mp mury and parmansm bmdng are required and can am We
and property and b the reisponslblllty of the truss aeetm
Sfudy the eonbats ofthe �e �on�� Induded on doUnry
•.iM,se.mlrtbsadardbraoeape�dad�rtopralwftUjlayadrnpa.
Thane must be act plumb and egwre
Do octw bunks or stack of plywoo4 molt rrlatwW er and '
algrei concentrated toads on manes. this can 600
DO NOT SET TRUSSES USING THIS LAYOUT
-USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
5105 Oleander Avenue
Ftort'Pleniel Florida 34982-SM
800-551-5932
Fwt Plan 7M"66 M2
Faz 771486"8711
Stuart inns= .
The
ArrhitecYs or Architect's representative's
shop drawing approval Ip NOT a
-119411`te check•• of the contractor.
The cunlractor shall remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from
graty and uplift loads and
their user a five loycatio`ns./
Approved By: / -�j'/
Date:
92-0/93.2 MITEK 4.2 F•r.o d.: „8 rlraden A.LA. P.A. -- --
DESIGN CRITERIA
County
SAINT LUCIE
Building Department
SAINT LUCIE COUNTY
Wind Design Criteria
ASCE 7-2014
Wind Design Method
Main Wind Force Resisting
Roofing Material
Shingle or Shake
'o —
m Loading in PSF
Roof R.D.L.
Top Chord Live
20
Top Chord Dead
7 4.2
:E
o I
Bottom Chord Live
10 Non -Concurrent
o
c
Bottom Chord Dead
10 3
,I TOTAL Load
37 7.2
--
cl
3 Duration Factor
o
1.25
cc m
,, Wind Speed
165mph
Top Chord C.B.
Sheeting by builder.
IA
s
Bottom Chord C.B.
Sheeting by builder.
3
~
Highest Mean Height
14'-0"
v
Building Type
ENCLOSED
Building Category
II:Non Restrictive
Exposure Category
C
Barrier Island
No
Conforms to FBC 2014
13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
DesignCriteria is the responsibility of the
Chambers Truss Inc. Drawing Name: M11323
Scale: 1 /4 = 1'
72 total trusses, 13 different trusses.
MI 4: SAE ACAD: SAE Reviewed By.. XIC /c/y/,j
Date:04/24/12 Revised:10/07/15
FOR
WYNNE BUILDING CORP.
DESCRIPTION:
62' GRAND CARLTON III
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
M 11323
IWoa I�41ia