HomeMy WebLinkAboutPrestige Step Plan STARKIE CLIENT / ADDRESS: DATE: 2.17.2021 Donald Starkie 501 Barb Anne Lane Port St. Lucie, FL 34952 PROJECT: STEP PLAN DETAIL PRINCIPAL OFFICE 7211 Hiawatha Pkwy Spring Hill, FL 34606 (352) 799-1500 1’-0” 4” X 4” PT POST UNIVERSAL SWIVEL STRAP CONNECTOR BY TIE DOWN ENGINEERING OR APPROVED EQUAL (SEE STRAP CONNECTOR DETAIL) 6” X ½” GALVANIZED STEEL NUT, BOLT WASHER 1-¼” GALVANIZED STEEL MFG. HOME ANCHOR FRAME TIE EARTH ANCHOR BY TIE DOWN ENGINEERING OR APPROVED EQUAL (SEE NOTE #1) 2X2 PT HANRAIL FASTENED TO 2X4 USING #10 X 3 ½ SCREW AT NEWELL POST 2X2 TOENAILED TO 4X4 AT LANDING AND 2X4 AT LANDING STAIR RISER 34” – 40” 5/4 DECKING FACE MOUNTED TO RISER 7 ¾” MAX HEIGHT 10” MIN. WIDTH 2X6 FASTENED WITH #8 3 ½” SCREWS LANDING MEASURMENT 40”X40” 36” MINIMUM GUARD 2X4 FASTENED TO 4X4 WITH #8X3 SCREWS LESS THAN 4” SPACE BETWEEN 2X2 LESS THAN 4.375” GENERAL NOTES: Pertinent 2017 Florida Building Code Residential Section R311 and 312 (R311.7.2 Headroom, R311.7.5.1 Riser Height, R311 .7.5.2 Tread Depth, R311.7.8 Handrails, R311.7.8.2 Continuity, R311.7.8.3 Handrail Grip Size, R312.1.2 Guards, R312 Guard Opening Limits) All lumber in the design is pressure treated All support posts for exterior stairway and landing structures shall rest on a minimum 8” X 16” X 4” thick concrete masonry or 8” X 16” X 6” thick poured in place concrete footing. The bottom of such footings shall be below the frost line or a minimum of 4” below grade, whichever is greater. CMU PADS STEP ANCHOR DETAIL