HomeMy WebLinkAboutAPPROVED FIX 400 LMI FL 37319.11/29/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquC8B43VWiHTZXdTQ9gd3VMoe7SKYLYlb75ddE%2b69VIuw%3d%3d 1/2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL37319
Application Type New
Code Version 2020
Application Status Validated
Comments
Archived
Product Manufacturer Mr-Glass Doors & Windows Manufacturing, LLC
Address/Phone/Email 8051 NW 79th Place
Medley, FL 33166
(305) 470-8284
ulises@mrglasswindows.com
Authorized Signature Ulises Senaris
ulises@mrglasswindows.com
Technical Representative Augusto Arias
Address/Phone/Email 8120 NW 84th St
Medley, FL 33166
(305) 470-8284
aarias@mrglasswindows.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Fixed
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Jalal Farooq
Florida License PE-81223
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 08/27/2025
Validated By JAVAD AHMAD PE, INC.
Validation Checklist - Hardcopy Received
Certificate of Independence FL37319_R0_COI_SS - Certificate of Independence.pdf
Referenced Standard and Year (of Standard)Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
1/29/2021 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquC8B43VWiHTZXdTQ9gd3VMoe7SKYLYlb75ddE%2b69VIuw%3d%3d 2/2
Product Approval Method Method 1 Option D
Date Submitted 01/27/2021
Date Validated 01/27/2021
Summary of Products
FL #Model, Number or Name Description
37319.1 MRG-400 Aluminum Fixed Window Large missile impact resistant aluminum fixed window.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +100/-100
Other: See drawings 21-02F for span vs load combination and
installation details.
Installation Instructions
FL37319_R0_II_SS - MG400 FIXED (LMI) DWG 21-02F
(2020).pdf
Verified By: Jalal Farooq PE #81223
Created by Independent Third Party: Yes
Evaluation Reports
FL37319_R0_AE_SS - MG400 FIXED (LMI) - PAE 2020.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
9360 Sunset Drive, Ste 220 | Miami, FL 33173 | T: 305.264.8100 | F: 305.262.6978 | www.afceng.com | alfarooq@afceng.com
PRODUCT APPROVAL EVALUATION
RULE CHAPTER #61G20-3 • METHOD 1 OPTION D
FL 37319
Date: 01/15/2021
Detailed Product Description:
Manufacturer: MR-GLASS DOORS & WINDOWS MANUFACTURING LLC.
Manufacturer Address: 8051 NW 79th PLACE, MEDLEY, FL 33166
Model Name: SERIES MRG-400 ALUMINUM FIXED WINDOW
Maximum Load: +100 PSF, -100 PSF (Large Missile Impact)
Installation Drawings # 21-02F
This product complies with the High Velocity Hurricane Zone (HVHZ) testing requirements.
For maximum sizes, combination of span vs loads and anchor type refer to installation drawings.
Comparative analysis used X Yes No
Mandatory Tests (Tested in accordance with AAMA 101/I.S.2/NAFS/TAS-202)
TEST DESCRIPTION TEST LOCATION TEST REPORT
DATE
TEST
REPORT #
Test Sealed by
ASTM E283 Air Infiltration
Leakage
Fenestration Testing
Laboratory, Inc.
01/24/2017 FTL-9147 Idalmis Ortega, P.E.
ASTM E331 OR ASTM
547 & TAS 202
Water
Penetration
Fenestration Testing
Laboratory, Inc.
01/24/2017 FTL-9147 Idalmis Ortega, P.E.
ASTM E330
& TAS 202
Uniform Static
Air Press.
Fenestration Testing
Laboratory, Inc.
01/24/2017 FTL-9147 Idalmis Ortega, P.E.
Supplemental Tests (Tested in accordance with TAS-201 and TAS-203)
TEST DESCRIPTION TEST LOCATION TEST REPORT
DATE
TEST
REPORT #
Test Sealed by
FBC 1626.2
(TAS 201 & 203)
Large Missile
Impact & Cyclic
Fenestration Testing
Laboratory, Inc.
01/24/2017 FTL-9147 Idalmis Ortega, P.E.
Under the limitations of the attached installation drawings, to the best of my knowledge and ability, the
above product conforms to the requirements of the 2020 Florida Building Code.
Evaluation Report Engineer:
Jalal Farooq PE # 81223
Al-Farooq Corporation EB # 3538
Sealed: 1/26/2021
Sealed: 1/27/2021
Sealed: 1/27/2021
Sealed: 1/27/2021
Sealed: 1/27/2021
Sealed: 1/27/2021
Sealed: 1/27/2021
Sealed: 1/27/2021