HomeMy WebLinkAboutTrussI!
A=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that should be read
given special attention by all persons installing trusses.
The Architect's or Architect's representaYlvo's
shop drawing approval is NOT a
"double check"
The contractor, hell rithMaeten responsible
ntractor. -
�'1 T for checking field hoaasurenlants and
® ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 17' 23' IN L_NG 1 fl other oftrusuttro,oneralrArchitect's
approval covers general roof shop®,
review of tru s strapping, and loading on
® Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hap ers — 5=`°°turefram T� �n
' their rE.ape i o c ens.
Approved By .,
Date: va .1.
SPACING NOTE
ALL TRUSSES ARE TO DE SET
AT 2' C: ON CENTER
j EXCEPT AS NOTED
L
MULTIPLE PLY TRUSSES MUST BE
ASTENED TOGETHER PER ENGINEERING
BEFORE SETTING. REFER TO
ENGINEERING DRAWING TO DETERMINE
LA IF MULTIPLE PLY.-
7
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Span or less A 30' to 60' Span
60 degrees Spree er Bar
or less
Tag Line span /approx.
REFER TO BCSI
Truss must be set this way if crone used.
Truss Is on .example, your truss may not rn. cn.
Insist crone operator sets truss this way,
I. g �__ Approx 2/3 to
Line 1/2 of. Span
REFER TO BCSI
iss must be set this way if crane used..
This is on example, truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams & lintels must be in place
at indicated height before trusses
A are installed. A
AIR HANpLIllR NOTIE=
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT
WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR,
U REPRESENTS A HANGER
For Truss to Truss
Connections see
hanger/connector
schedule in engineering
package.
Carying Girder
Nails must be as
shown. Guide tabs of
Dome angle nails.
Truss
INDICATES LOAD BEARING WALL
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-1"
ABOVE FINISHED FLOOR
12
4.00
M
upset=1/4" heel=315/16"
PLUMB CUT END
1'
2 x 4 Top Chord
WALL HEIGHT 8'-1"
TYPICAL END DETAIL
12
4.00 l
2 2.00
sue_
`� upset=1/4" heel=315116"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8,_1„
END DETAIL: A
L.
a .-
GARAGE LEFT
34'
20'
14'
ii/////i%I////1V"'I.ii///PAi
I////// 1
ii;//,I
VA.
�i
ii/////IWE=I%////ii,///i//////1%////,ii//�/.i
✓//i/
ON
��/
------------'----- ---------------------------
%
------------------
10
100
70,0N
®®�0101
0
I
1_�I
0100001,
I%'
%
,
01
_
pp■IlI■111�11��
wimimi
I
l�,�
FA9ffi A 1f105N 1kGR6EMENT°'
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description of the property where the trusses will be Installed Is:
The undmulgned acknowledges and agrees:
t: Trusses will be made In strict accordance with this truss placement diagram layout,
which Is the sole authority, for detennlning.suecessful fabrication of the trusses.
2. All dimensions In this layout have been verified by the undersigned.
.3. Unless written notice Is provided by cerefied mall to Chambers Truss within tan (10)
days of delivery the undersigned agrees that no backcharges will be allowed.. In the event
such written notice Is famished Chambers Truss shall have three (3) buness days In which
to begin repalre required, or to substli other trusses, at Chambers opd n.'
4. The undersigned acknowledges receipt of "BCSI 1.03" summary sheet by'TPI & WTCA.
6. Delivery Is to job site. It Is the buyere'responelbility to make the job site suitable for
delivery. Chambers Truss has the sole authority to determine the suitability of the job alto or a
portion of the job site for delivery. Chambers Truss will be responsible for dump delivery only.
The buyer is responsible for additional delivery expenses If Chambers Truss has to redeliver
because job she Is not prepared for delivery or buyer Is not prepared for delivery of trusses.
Buyer Is responsible to Chambers Trues for towing coats duo to site conditions.
e. Price as shown Iq paragraph 7 below Is subject to change H any changes are, made In
this. layout A $60 per hour fee for revisions may be charged by Chambers Truss..'
,7. This is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If nil
,agreement a reasonable price. Invoice wlll be made on delivery and paid within terms of not
on delivery. Invoice may be made at scheduled date of delivery If buyer cannot accept
delivery of fabricated trusses
The undersigned agrees to pay Chambers.Truss reasonable
ationn"i tea for collecilons In event of payment not timely made. 1-12 °h, per month servjce
charge will be added for all cuss not paid -within terms.
. e. Signature or Initials arrywhere on this sheet constitutes agreement to all terms herein.
9an consideration of Chambers Truss extending credit for this materiel the undersigned
unconditionally guarantees payment when due of any and all Indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including attorneys fees. If default In payment for material be made by the
recipient.
1.
10. In the event of any litigation concerning this agreement, the Items famished hereunder
or payments referred to herein, the. parties agree that the sole venue for any such action will.
be Saint bticle County, Florida.
11. Design responsibilities are per -National Standard And Recommended Guidelines On
Ra'sponsibllltles For Construction Using Metal Plate Connected Wood Trusses
ANSVrplWTCA 4-2002"
DATED
SIGNED -.
FOR TITLE.�-�
A. spreader bar may be required per"BCSI I-W' Io prevent injury & damage. .
Multiple ply trusses must be fastened tog®thar per engineering
before they are set; failure to do so can result In roof COISpE0.
Temporary and permanent bracing are required and can save life
and property and Is the responsibility of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
Trustees must be setand braced per design to prevent injury & darnago.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
Other concentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS LAYOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Plerdej Florida 34982-6423
800-551-5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772-569-2012 Stuart '172-2863302 "
l,EfIE EIS FOR
tom,_ E d FL.I,A.NCE
'T LUCIE, ti 1%,I TV
92.0/93.2 MITE"Rs2
DESIGN CRItRIA
County SAINT LUCIE
Building Department SAINT LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MWFIRS/C-C hybrid Wind ASCE 7-1
Roofing Material Shingle or Shake
0 :5 N Loading in PSF Roof R.D.L.
N o Top Chord Live F1LEOcoPv,
Top Chord Dead 14.2
c , c �? Bottom Chord Live 10 Non -Concurrent
w d Bottom Chord Dead 10i 3
m TOTAL Load 37 7.2
M 0 Duration Factor 1.25
v Wind Speed 165mph
y N Top Chord C.B. Sheeting by builder.
�� .� Bottom Chord C.B. Sheeting by builder.
Highest Mean Height 14'-0
Building Type ENCLOSED
Building Category IINon Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: M11323
Scale: 1 /4 = 1'
72 total trusses, 13 different trusses.
MI 4: SAE ACAD: SAE Reviewed By:
n Date: 04/24/12 Revised: 02/21/18
FOR Revised:3/05/2020
WYNNE BUILDING CORP.
DESCRIPTION: _-7-1 a05
CARLTON
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
13 TRUSS DRAWINGS ARE AZFACHED TO LA)(OUT M 11323
MiTeko
RE: M11323 MiTek USA, Inc.
M11323 6904 Parke East Blvd.
Tampa, FL 33610-4115
Site Information:
Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323
Lot/Block: Model: CARLTON
Address: N/A Subdivision:
City: PORT ST LUCIE , State: FL
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
1
T19884596
A
12/17/2020
2
T19884597
A5
12/17/2020
3
T19884598
A6
12/17/2020
4
T19884599
A7
12/17/2020
5
T19884600
A8
12/17/2020
6
T19884601
A9
12/17/2020
7
T19884602
GRA
12/17/2020
8
T19884603
GRB
12/17/2020
9
T19884604
J2
12/17/2020
10
T19884605
J4
12/17/2020
11
T19884606
J6
12/17/2020
12
T19884607
J8
12/17/2020
13
T19884608
KJ8
12/17/2020
This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision
bsed on te parameters
by Chambers
Truss Deshgn Engineer's Nramee Velez, Joaquin Truss. ���`%�OP'aC•E NV �<�
My license renewal date for the state of Florida is February 28, 2021. ��` •• �� SF•'•. ���
Florida COA: 6634 No 68182
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
I of I
3 STATE OF .:�V✓
;0 N A; E %%%'
Joaquin Velez PE No.68182
MRek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 December 17, 2020
Velez, Joaquin
Job
Truss
Truss Type
City
Ply
M11323
`
T19884596
M11323
A
COMMON
9
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 Page 1
ID:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k_1 Hpv5SDpc_pEKrtnVLQuvtwTtLrJWzUUjw
r1-0-Q 6-7-13 12-4-13 17-0-0 21-7-3 27.4-3 34-0-0 $5-0-Q
1-0-0 6-7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 1-0-0
6
0
3x6 =
6-7-13
4.00 12 4x5 =
27
17 "- 15 -- -' 14 '- 12
2x3 II 4x6 = 3x8 =
3x8 = 4x6 = 2x3 II
Scale = 1:57.8
3x6 =
1 �
IA
6
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.39
BC 0.58
VVB 0.65
Matrix -MS
DEFL. in (loc) I/dell Ud
Vert(LL) 0.32 14-15 >999 360
Vert(CT) -0.61 14-15 >670 240
Horz(CT) 0.12 10 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 163 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-12 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 8)
Max Uplift 2=-832(LC 10), 10=-832(LC 10)
Max Grav 2=1362(LC 1). 10=1362(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3419/2395, 3-5=-2771/2031, 5-6=2770/2152, 6-7=2770/2152, 7-9=2771/2031,
9-10=-3419/2395
BOT CHORD 2-17=-2132/3213, 15-17=-2132/3213, 14-15=-1269/2000, 12-14=2132/3213,
10-12=-2132/3213
WEBS 6-14=-635/983, 7-14=-313/362, 9-14=689/499, 6-15=-635/983, 5-15=-313/362,
3-15=-689/499
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3
to 20-4-13, Interior(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
Will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
electronically signed and
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) except (jt=lb)
sealed by Velez, Joaquin, PE
2=832, 10=832.
using a Digital Signature.
6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at
Printed copies of this
15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility
of others.
document are not considered
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B),
signed and Sealed and the
signature must be verified
LOAD CASE(S) Standard
on any electronic copies.
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Joaquin Velez PE No.68182
Vert: 1-6=54, 6-11=54, 18-21=-20
MiTek USA, Inc. FL Cart 8634
Concentrated Loads (lb)
8904 Parke East Blvd. Tampa FL 33610
Vert: 26=-50(F) 27=50(17)
Data:
April 3,2020
® WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see AMSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
•
T19884597
M11323
A5
SPECIAL
9
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1
ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzUUjv
T1-0•Q 7-8-5 10-6-4 17-0-0 20-4-8 26-4-0 34-0-0 35.0-Q
'1 0-0' 7-8-5 2-9-15 6-5-12 34-8 1 5-11-8 7.8-0 -0-0
�1
Sx8 MT18HS 11
4.00 F12
Scale = 1:59.8
13 12
5x12 = 2x3 11 3x6 =
3x12 = 2.00 F12
10-6-4
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017rrP12014
CSI.
TC 0.85
BC 0.90
WB 0.60
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) 0.76 14 >539 360
Vert(CT) -1.18 13-14 >344 240
Horz(CT) 0.36 10 n/a n/a
PLATES
MT20
MT18HS
Weight: 155 lb
GRIP
244/190
244/190
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 1-7-8 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 3-9-12 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-14
6-14: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0,-
Max Horz 2=-179(LC 8)
Max Uplift 2=-803(LC 10), 10=803(LC 10)
Max Grav 2=1312(LC 1). 10=1312(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5529/3776, 3-5=-5164/3538, 5-6=5209/3667, 6-7=2424/1902, 7-9=2462/1813,
9-1 0=-3195/221 0
BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995
WEBS 3-14=-355/314, 5-14=-293/354, 6-14=2175/3326, 6-13=279/534, 7-13=-237/277,
9-13=-786/560, 9-12=0/269
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3
to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
This item has been
4) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
electronically Signed and
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Velez, Joaquin, PE
will fit between the bottom chord and any other members.
using a Digital Signature.
6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
Printed copies of this
p
rapacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
document are not considered
2=803,10=803.
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iw iTek`
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884598
M11323
A6
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1
ID:2GIScwwyY5hnGhXVARzUkuyu FU M-YYr6a4 B_WeYX90cbw00H Jlx7i IyPMm 6DxBgy00zU Uj u
8-11-11 16-0-0 18-0-0 , 204-8 2%11-15 34-0-0 35-01
8-11-11 ' 7-0-5 2-0-0 2-4-8 5-7-7 8-0-1 -0-0
6
3x12 =
2.00 12
4.00 12
6x10 MT18HS =
Sx6 =
Scale = 1:61.9
0�2 I I�, I
0
1Z 11
5x6 = 2x3 11 3x6 =
25-11-15 34-0-0 ,
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) Vdefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.81
Vert(LL)
0.69 14 >590 360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.93
Vert(CT) -0.92 14-17 >443 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB 0.86
Horz(CT)
0.34 9 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 157 lb
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30 *Except*
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
3-5,6-7: 2x4 SP M 31
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 *Except*
5-14: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-169(LC 8)
Max Uplift 2=-803(LC 10), 9=803(LC 10)
Max Grav 2=1312(LC 1).9=1312(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=-2314/1551, 6-8=2398/1533, 8-9=3199/1981
BOT CHORD 2-14=-3040/5224, 13-14=-1195/2361, 12-13=-1123/2199, 11-12=-1731/3001,
9-11=-1731 /3001
WEBS 4-14=-492/513, 5-14=-1707/2959, 5-13=-405/196, 6-13=179/522, 8-12=-893/660,
8-11=0/303
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=803, 9=803.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall r
building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing M iTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPll quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Satety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qly
Ply
M11323
T19884599
M11323
A7
SPECIAL
1
1
Job Reference a tional
Chambers Truss, Inc., Fort Pierce, FL
6
5x8 =
e nn
5x6 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1
eur6hk9UjG5yuFUL-OIPUnQCcHygOmYBnUkXWryTIFi l45CtN9gaVwrcUUjt
25-11-15 34-0-0 35-04
5-11-15 8-0-1 0-0
Scale = 1:60.8
5x12 = 2x3 II 3x6 =
3x12 = 2.00 F12
LOADING (psi)
SPACING-
2-0-0
TCLL 20.0
Plate Grip DOL
1.25
TCDL 7.0
Lumber DOL
1.25
BCLL 0.0
Rep Stress Incr
YES
BCDL 10.0
Code FBC2017rrP12014
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
*Except*
4-11: 2x4 SP
M 30
REACTIONS. (size) 2=0-8-0, 7=0-8-0
Max Horz 2=-149(LC 8)
Max Uplift 2=-803(LC 10), 7=-803(LC 10)
Max Grav 2=1312(LC 1),7=1312(LC 1)
34-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATES GRIP
TC 0.83
Vert(LL) 0.66 11 >616 360
MT20 244/190
BC 0.90
Vert(CT) -1.10 10-11 >369 240
MT18HS 2441190
WB 0.95
Horz(CT) 0.34 7 n/a n/a
Matrix -MS
Weight: 147 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=2229/1544, 5-6=2448/1599, 6-7=3169/1993
BOT CHORD 2-11=-3071/5219, 10-11 =-1 590/2874, 9-1 0=-1 738/2968, 7-9=-1738/2968
WEBS 3-11=-419/443, 4-11 =-1 466/2647, 4-1 0=-81 21448, 5-10=-205/487, 6-10=-785/575,
6-9=0/272
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify
rapacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=803,7=803.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verlfy the applicability of design parameters and properly Incorporate this design into the overall i
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k•
Is
always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rPI1 Duality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884600
M11323
A8
SPECIAL
1
1
"
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1
ID:WSJgpGwalPpeur6hk9UjG5yuFUL-Uxzs mCE2FoFOil_2R210AOTj6eKgEWOUJ2SHzUUjs
�1-0-q 8-8-4 12-0-0 15-8-4 20-4-8 , 22-0-0 , 24.8-12 34-0-0 35-0-q
i-0-0' 8-8-4 3-3 12 3-8 4 4-8-4 1-7-8 2 8-12 9-3-4 -0-0
5x6 =
4.00 12
3x4 = 2x3 11 5x8 =
21 5 6 22 7 o.z
12 11
5x12 = 3x4 = 4x5 =
3x12 = 2.00 12
10-6-4
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.78
TCDL 7.0
Lumber DOL 1.25
BC 0.90
BCLL 0.0
Rep Stress Incr YES
WB 0.69
BCDL 10.0
Code FBC2017rrPI2014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-129(LC 8)
Max Uplift 2=-803(LC 10), 9=803(LC 10)
Max Grav 2=1312(LC 1).9=1312(LC 1)
Scale = 1:60.6
DEFL.
in floc)
I/deft
Ud
PLATES
GRIP
Vert(LL)
0.65 12-13
>624
360
MT20
2441190
Vert(CT)
-1.08 12-13
>379
240
MT18HS
2441190
Horz(CT)
0.33 9
n/a
n/a
Weight: 154 lb
FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5488/3444, 3-4=-5117/3183, 4-5=3911/2497, 5-6=-2576/1770, 6-7=2586/1779,
7-8=-2663/1762,8-9=-3021/1971
BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11 =-1 70512827
WEBS 3-13=-396/420, 4-13=-1028/1721, 5-13=-300/797, 5-12=-894/601, 6-12=-265/263,
7-12=-294/391, 7-11=-374/691, 8-11=-535/502
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3
to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=803, 9=803.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall A
iTek`
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the A
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Duality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
M11323
T19884601
M11323
A9
HIP
1
1
-
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:32 2020 Page 1
ID:_etC1cxC3ixVV?huls?ypJyuFUK-y7XEC6DspZw6OsKAc9Z xNZ18W4CZ7Mfd83c?jzUUjr
T1-0-q 6-7-15 10-0-0 15-2-14 20-4-0 240 0 27-0-1 34-0.0 5-0-Q
-0-0 6-7-15 3-0-1 5-2-14 5-1-2 3-8-0 3-0-1 6-7-15 1-0-0
4.00 F12
3x5 =
4x4 = 3x4 = 2x3 II 4x8 =
4 24 525 26 6 27 7
14 lL
3x8 = 3x6 =
6x8 = 3x6 = 3x4 =
10-0-0 204-0 2411 I 34-M _
10-0-0 10-4-0 3-8-0 10-M
Scale = 1:58.6
3x5
M
0 �2
IA
6
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.35
Vert(LL)
-0.18 11-21
>917
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.54
Vert(CT)
-0.38 11-21
>432
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.89
Horz(CT)
0.02 13
n/a
n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 156 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0
Max Horz 2=109(LC 9)
Max Uplift 2=-430(LC 10). 9=249(LC 10), 13=-928(LC 10)
Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1)
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1275/1025, 3-4=-913/708, 4-5=829/705, 5-6=-565/807, 6-7=565/807,
7-8=-104/278, 8-9=341/235
BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=124/304
WEBS 3-15=-425/501, 5-15=-444/665, 5-13=-1215/1079, 6-13=-264/300, 7-11=-255/396,
8-11=-461/521, 7-13=-837/703
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to
14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0
zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
2=430,9=249,13=928.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS17rP1f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884602
M11323
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 1
ID:_etC 1 cxC3ixVV?huls?ypJyuFU K-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq
"r1-0-q 8-0-0 11-1-1 17-0-0 18 6-0 22-2-2 26 0.0 34-0-0 $5-0-Q
No 8-0-0 3-1-1 5-10-15 1:6 3-8-2 3-9-14 8-0-0 -0-0
THIS TRUSS IS NOT SYMMETRIC.
PROPER ORIENTATION IS ESSENTIAL.
4x4 =
Scale = 1:60.6
3x6 II
3x6 = 6x8 = 3x6 = 6x8 = 4x4 =
3x5 —_
6x8 =
TRUSS DESIGNED FOR WIND LOADS IN THE PLANE
OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND
(NORMAL TO THE FACE), SEE STANDARD INDUSTRY
GABLE END DETAILS AS APPLICABLE, OR CONSULT
QUALIFIED BUILDING DESIGNER AS PER ANSIrrPI 1.
8-0-0
11-1-1 18-6-0 26-0-0 34-0-0
8-0-0
3-1-1 74-15 7-6-0 8-0-0
Plate_ Offsets (X,Y)— [2:0-2-2,Edge], [3:0-3-8,Edge], [21:0-3-8 Edge], [24:0-3-8,0-3-0] [27:0-3-8,0-3-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Well Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.91
Vert(LL) 0.20 24-35 >914 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.57
Vert(CT) -0.24 29-32 >552 240
BCLL 0.0
Rep Stress Incr NO
WB 0.98
Horz(CT) 0.02 22 n/a n/a
BCDL 10.0
Code FBC2017frPI2014
Matrix -MS
Weight: 194 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc puriins.
BOT CHORD 2x4 SP M 30
Except:
WEBS 2x4 SP No.3
1 Row at midpt 8-21
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-179(LC 6)
Max Uplift All uplift 100 lb or less at joints) except 2=351(LC 8), 27=-1168(LC 8), 26=-1495(LC 8),
22=-625(LC 8)
Max Grav All reactions 250 Ib or less at joints) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14),
22=984(LC 14)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-621/387, 3-5=304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209,
12-13=-588/1209,13-15=-588/1209,15-16=-588/1209,16-18=-588/1209,
18-20=-2230/1280, 20-21=2230/1280, 21-22=2271/1263, 6-9=-126/305, 9-11=-106/363,
11-14=-193/412, 14-17=-94/271, 19-21=-143/272
BOT CHORD 2-29=-247/677, 27-29=-189/540, 26-27=-779/446, 24-26= 411/653, 22-24=1083/2108
WEBS 3-29=-500/1176, 3-27=-1766/911, 5-27=-748/622, 5-26=546/351, 13-26=-946/617,
18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=-608/514, 19-20=335/305,
14-15=-556/407, 11-12=-254/54
NOTES-
1) Unbalanced roof live loads have been considered for this design.
This Item has been
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
electronically signed and
3) Provide adequate drainage to prevent water ponding.
Sealed by Velez, Joaquin, PE
4) All plates are 2x3 MT20 unless otherwise indicated.
using a Digital Signature.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
Printed copies of this
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
document are not considered
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at
signed and sealed and the
joint 27, 1495 Ib uplift at joint 26 and 625 Ib uplift at joint 22.
Signature must be Verified
8) Girder carries hip end with 8-0-0 end setback.
On any eleCtct
C electronic
IC copies.
9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Joaquin Velez No 2
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
MiTek USA, Inc. FL Cert 8 34
26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the
8904 Parke East Blvd. Tampa FL 33810
P
responsibility of others.
Data:
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
April 3,2020
ndard
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPlf quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
PIy
M11323
T19884602
M11323
GRA
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2
ID:_etC1 cxC3ixVV?huls?ypJyuFU K-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=54, 21-23=54, 29-30=-20, 24-29=47(F=-27), 24-33=20, 3-11=-126(F=-72), 11-21 =-1 26(F=-72)
Concentrated Loads (lb)
Vert: 29=-641(F) 24=641(F)
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safetyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
M11323
T19884603
M11323
GRB
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1
ID: SrRaEyyrgD4M78G4raWBLWyuFUJ-uWe?doF7LAApF9UZjacSOce_iJj P 10by4SYi3czUUjp
r1 0 q 8-M 13-8-0 17-0-0 20-4-0 26-0-0 34-0-0 5 0-Q
-0-0 8-0-0 6"
0 3 4 0 3 4-0 5-8-0 8-0-0 1-0-0
N.
d
5x12 MT18HS =
4.00 12
4x10 =
2x3 I I 4x6 =
23 4 5 6
2x3 11
7 24
u iZ
5x12 MT18HS =
Scale = 1:58.6
46 — 3x6 II 5x6 = 6x12 = 6x12 = 5x6 = 3x6 II 4x6 —
8-0-0 13.8-0 208-4-0 26-0-0 34-0-0
8-0-0 5-8-0 6 -0 5-8-0 8.0-0
Plate Offsets (X,Y)—[3:0-9-0,0-2-8),[5:0-3-0,Edge),[8:0-9-0,0-2-8)
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Vdefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.80
Vert(LL)
0.22 16-19 >999 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.68
Vert(CT) -0.30 16-19 >820 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB 0.90
Horz(CT)
0.06 9 n/a n/a
BCDL 10.0
Code FBC20171TPI2014
Matrix -MS
Weight: 153 lb
FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-1-14 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 5-3-14 oc bracing.
WEBS 2x4 SP No.3 "Except'
WEBS
1 Row at micipt 3-14,
8-13, 6-13
4-14,7-13: 2x6 SP No.2
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0
Max Horz 2=90(LC 7)
Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=-345(LC 8)
Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3625/1950, 3-4=-208011236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-1296/2589,
8-9=-751/370
BOT CHORD 2-16=-1729/3460, 14-16=-1753/3525, 11-13=-2621733, 9-11=-241/668
WEBS 3-16=-435/1209, 3-14=-1552/774, 4-14=-837/691, 7-113=878/713, 8-13=-3635/1919,
8-11=-432/1204, 6-14=-145312814, 6-13=-3198/1807
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
This item has been
6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
electronically signed and
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at
sealed by Velez, Joaquin, PE
joint 13 and 345 lb uplift at joint 9.
using a Digital Signature.
8) Girder carries hip end with 8-0-0 end setback.
Printed COpleS Of this
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at
document
26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the
are not considered
responsibility of others.
signed and sealed and the
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B),
signature must be Verified
LOAD CASE(S) Standard
on any electronic copies.
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6834
Uniform Loads (plf)
Vert: 1-3=54, 3-8=1 31 (F=77), 8-10=-54, 16-17=-20, 11-16=49(F=-29), 11-20=-20
6904 Parke East Blvd. Tampa FL 33610
Data:
April 3,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE.
Design valid for use only with Mi rek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall MiTek'
�•
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Iyl iTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
'
T79884603
M11323
GRB
HIP
1
1
Job Reference o tional
cnamoers I cuss, Inc., tort Fierce, I-L
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 16=-641(F) 11=641(1`)
8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2
ID:SrRaEyyrg04M7BG4raWBLWyuFUJ-MiCNg7G16U IgtJ31HH7hYOB9Sj3emSr6J6HGb2zUUjo
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Sal'
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrPlf Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884604
M11323
J2
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1
ID:xl?zSlzTbJCDIIrGPH1 QukyuFUI-MiCNg7Gl6UIgtJ31HH7hYOBJ7jCDmgz6J6HGb2zUUjo
1-0 0 2-0-0
1-0-0 2-M
Scale = 1:7.8
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.07
Vert(CT) -0.00
7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Weight: 8 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=67(LC 10)
Max Uplift 3=-28(LC 10), 2=136(LC 10), 4=-3(LC 7)
Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 Ito uplift at joint
2 and 3 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
8904 Parke East Blvd. Tampa FL 33610
Data:
April 3,2020
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
■.Y
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
__A]
Truss
Truss Type
Qty
Ply
M11323
-
T19884605
M11323
J4
MONO TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
3x4 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1
ID:PDYLfd_5MdK4MSQTz?ZfRxyuFUH-qvm 12TGNtoQXUTexr?ew5DjQ W7UmV7DFYm 1 p8UzUUjn
4-0-0
Scale = 1:11.1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Lld
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) 0.02 4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.02 4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a rile
BCDL 10.0
Code FBC2017[TP]2014
Matrix -MP
Weight: 14 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=104(LC 10)
Max Uplift 3=-80(LC 10), 2=-161(LC 10), 4=-7(LC 10)
Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint
2 and 7 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
•
T19884606
M11323
J6
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1
ID:tP6jtz_j7xSx_c fXi4uz9yuFUG-gvml2TGNtoQXUTexr?ew5DjR?7MUV7DFYm1p8UzUUjn
1-0-0 6-0-0
1-0-0 6-M
Scale = 1:14.6
3x4 =
6-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deB L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.36
Vert(LL) 0.11
4-7 >629 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.83
Vert(CT) -0.12
4-7 >617 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MP
Weight: 20 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=142(LC 10)
Max Uplift 3=-131(LC 10), 2=-194(LC 10), 4=-B(LC 10)
Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at
joint 2 and 8 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.66162
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
April 3,2020
WARNING - Vedly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Ouafrry Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884607
M11323
J8
MONO TRUSS
20
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1
ID:tP6jtzJ7xSx_c_fXi4uz9yuFU G-J5K7FpH?d5Y06dD8Oi99eRGYgXquEaTPmQmNgxzUUjm
i -1-0-0 8-0-0
1-0-0 8-0-0
Scale = 1:17.4
3x5 =
8-0-0
8-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
([cc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.62
Vert(LL) 0.26
4-7 >367 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.38
Vert(CT) -0.30
4-7 >319 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MP
Weight: 26 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc purlins.
BOT CHORD 2x4 SP M 31
BOT CHORD
Rigid ceiling directly applied or 10-0-0 cc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=180(LC 10)
Max Uplift 3=-175(LC 10), 2=228(LC 10), 4=-15(LC 10)
Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Exterior(2) 3-1-13
to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at
joint 2 and 15 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33810
Date:
April 3,2020
AL WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall r
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
M11323
T19884608
M11323
KJS
MONO TRUSS
4
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1
ID:Lcg54J?LuEancmZr4Qb7 WMyuFUF-nHuVT91dOPgFknoKyPgOAeooawBGzwZY?4WwCNzUUjI
-1-5-0 7-3-4 11-3-0
1-5-0 7-3-4 3-11-12
3x4 =
Scale = 1:20.3
3x4 =
7-34
11-3-0
' 7-34
3-11-12
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.29
Vert(LL) 0.07
7-10 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.30
Vert(CT) -0.12
7-10 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.46
Horz(CT) 0.02
6 n1a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 44 lb FT = O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 8-9-6 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical
Max Horz 2=244(LC 8)
Max Uplift 4=-205(LC 8), 2=305(LC 8), 6=-286(LC 8)
Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1151/523
BOT CHORD 2-7=-687/1126, 6-7=-687/1126
WEBS 3-7=0/330, 3-6=-1236/755
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at
joint 2 and 286 lb uplift at joint 6.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
This item has been
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
electronically signed and
Uniform Loads (plf)
sealed by Velez, Joaquin, PE
Vert: 1-2=-54
Trapezoidal Loads (plf)
using a Digital Signature.
Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10, B=10)-to-5=-56(F=-18, B=18)
Printed copies of this
p
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cent 6834
6904 Parke East Blvd. Tampa FL 33610
Data:
April 3,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall IMF 1•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Cdferla, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols
Numbering System
A General Safety Notes
PLATE LOCATION AND ORIENTATION
� 3/ " Center plate on joint unless x, y
4 offsets are indicated.
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
1
Failure to Follow Could Cause Property
Damage or Personal Injury
Dimensions are in ft-in-sixteenths.
1. Additional stability bracing for truss system, e.g.
Apply plates to both sides of truss
1 2 3
diagonal or X-bracing, is always required. See BCSI.
and fully embed teeth.
TOP CHORDS
2. Truss bracing must be designed by an engineer. For
O-�1fi
c1-2 c2-3
wide truss spacing, individual lateral braces themselves
bracing, Tor I
WEBS
p1
0LCI
may require or alternative
bracing should be considered.
3. Never exceed the design loading shown and never
S �O
UCL
ACS-6
stack materials on inadequately braced trusses.
U
4. Provide copies of this truss design to the building
a0
designer, erection supervisor, property owner and
For 4 x 2 orientation, locate
E
BOTTOM CHORDS
CHORDS
all other interested parties.
plates 0- ''is' from outside
p
5. Cut members to bear tightly against each other.
edge of truss.
8 7 6 5
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
This symbol indicates the
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
locations are regulated by ANSI/TPI 1.
required direction of slots in
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
7. Design assumes trusses will be suitably protected from
connector plates.
the environment in accord with ANSUTPI 1.
' Plate location details available In MiTek 20/20
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
8. Unless otherwise noted, moisture content of lumber
software or upon request.
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
PLATE SIZE
PRODUCT CODE APPROVALS
use with fire retardant, preservative treated, or green lumber.
ICC-ES Reports:
10. Camber is a non-structural consideration and is the
The first dimension is the plate
responsibility of truss fabricator. General practice is to
4 X 4 width measured perpendicular
ESR-1311, ESR-1352, ESR1988
camber for dead load deflection.
to slots. Second dimension is
ER-3907, ESR-2362, ESR-1397, ESR-3282
11. Plate type, size, orientation and location dimensions
the length parallel to slots.
indicated are minimum plating requirements.
LATERAL BRACING LOCATION
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
Indicated by symbol shown and/or
by text in the bracing section of the
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
13. Top chords must be sheathed or pudins provided at
spacing indicated on design.
output. Use T or I bracing
if indicated.
Lumber design values are in accordance with ANSI/TPI 1
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
section 6.3 These truss designs rely on lumber values
BEARING
established by others.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
Indicates location where bearings
approval of an engineer.
(supports) occur. Icons vary but
reaction section indicates joint
© 2012 MiTek@ All Rights Reserved
17. Install and load vertically unless indicated otherwise.
number where bearings occur.
Min size shown is for crushing only.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
Industry Standards'
191
19. Review all portions of this design (front, back, words
ANSI/TP11: National Design Specification for Metal
and pictures) before use. Reviewing pictures alone
is not sufficient.
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
11
20. Design assumes manufacture in accordance with
BCSI: Building Component Safety Information,
ANSIrrPI 1 Quality Criteria.
Guide to Good Practice for Handling,M!Tek
Installing & Bracing of Metal Plate
21.The design does not take into account any dynamic
' Connected Wood Trusses.
MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020
or other loads other than those expressly stated.