HomeMy WebLinkAboutCompaction Test (2)G���Ntni • cEorFcti
2 Universal Z&xg Sciences
• • •--
02
G
9(S TFSiING'�N�e�
•
UES Project No: 3310.1500002.0000
Workorder No: 221173-1
Report Date: 02/22/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: GHO HOMES CORPORATION UES Technician: Sean Hayes
590 NW Mercantile Place Date Tested: 12/24/2020
Port St. Lucie, FL 34986
Project: MEADOWOOD SUBDIVISION (FDC)
Meadowood Dr. Various Lots,Fort Pierce, County, FL 34951
Type of Test:
Area Tested: Lot 63 - 2646 Conifer Drive Field: ASTM D-6938 Nuclear Gauge Method
Material: Native Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Native
The tests below meet the 95% minimum compaction requirement.
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
SE Corner
0-1 ft
117.8
11.1
114.8
10.6
97
Pass
2
NW Corner
0-1 ft
117.8
11.1
115.5
11.1
98
Pass
3
Center
0-1 ft
117.8
11.1
113.9
10.2
97
Pass
Remarks: Permit 1912-0236
Reviewed By
GFA International, Inc
Certificate of Authorization No. 4930
Digitally signed
John by John Kent
Date:
Kent2021.02.22
11:54:12-05'00'
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1