Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
jb_349238_00_b_acad_b_01
ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A BUILDING CONC CONCRETE DC DIRECT CURRENT UL—LISTED POWER—CONDITIONING INVERTER. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY—RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL STEEL STC STANDARD TESTING CONDITIONS TYP COMPLY WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. VICINITY MAP INDEX r Sheet 1 COVER SHEET • Sheet 2 SITE PLAN Sheet 3 THREE LINE DIAGRAM Sheet 4 THREE LINE DIAGRAM LICENSE GENERAL NOTES Sheet 5 SITE PLAN PLACARD Cutsheets Attached 1. ALL WORK SHALL COMPLY WITH THE 2020 FLORIDA BUILDING CODE (7TH EDITION), FLORIDA FIRE # t PREVENTION CODE (7TH EDITION). 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE. • AHJ: St. Lucie County + REV BY DATE COMMENTS REV A NAME DATE COMMENTS s UTILITY: Florida Power and Light J B-3 4 9 2 3 8 O O CUSTOMER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: JOven Villaman 10.46613 KW PV ARRAY T = S L n CONTAINED SHALL NOT BE USED FOR THE Alex Webster BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 426 SE Gasparilla Ave 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34983 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (179) TESLA # SR60T1 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. MULTIPLE INVERTERS 5616672896 COVER SHEET 1 7/30/2020 PITCH: 9 ARRAY PITCH:9 IVP2 AZIMUTH: 146 ARRAY AZIMUTH: 146 MATERIAL: Solar Roof STORY: 2 Stories PITCH: 18 ARRAY PITCH:18 IVP4 AZIMUTH:326 ARRAY AZIMUTH: 326 MATERIAL: Solar Roof STORY: 2 Stories PITCH: 18 ARRAY PITCH:18 MP7 AZIMUTH: 146 ARRAY AZIMUTH: 146 MATERIAL: Solar Roof STORY: 2 Stories S d W 9dW a r, r, r, r, r, r, r, i f l f lL r, rl flL `i fl Pth F fl I l Fl El I Fl El F� iLJI-1F1E1I-� Ilflflll W LJ L ® F1 F1 E1I � Vl LEGEND U,ll I I r, Fl F1 E1 I-� Ziz 1 I r l f l+r l y`� l l+r i F L J L J O (E) UTILITY METER & WARNING LABEL 11 + l l + L J L J L J Front Of House F 1 11 1 l 11 i i i INVERTER W/ INTEGRATED DC DISCO I [1 [l [1 [i L J & WARNING LABELS F l E 1 F l EliDC I DC DISCONNECT & WARNING LABELS F 1 E l 1 J ® AC DISCONNECT & WARNING LABELS L i 4i 1 I lL J� �! i DC JUNCTION/COMBINER BOX & LABELS r, r' " [I lri ® B F L J `J f i i �D DISTRIBUTION PANEL & LABELS Q' r l I I�r I�r ® F Lc LOAD CENTER & WARNING LABELS E1 Fl Fl El 4/12 r, Fl F1 El 1 a I f lI I lI lI f lI �3 III I I I M DEDICATED PV SYSTEM METER (E)DRIVEWAY F1 El F1 F1 E1 I� I l fi F1 E1 El I O N E 1 I 1 F 1 E 1 I f lL I lL J�l! f lL I RSD RAPID SHUTDOWN n F 1 L! LJ LJ LJ I 1F 11 1E 11 1F 11 1E 11 11 LA LJ LJ L� LJ E 11 1I STANDOFF LOCATIONS L S CONDUIT RUN ON EXTERIOR J CONDUIT RUN ON INTERIOR I, �I �� mP1 I � D GATE/FENCE`J% O HEAT PRODUCING VENTS ARE RED ORE© S Inv Lc ESS Ik-J INTERIOR EQUIPMENT IS DASHED ESS SITE PLAN Scale: 3/32" = 1' 01, 10, 21' J B-3 4 9 2 3 8 O O CUSTOMER: DESCRIPTION: DESIGN: CONTAINEDAL A THE INFORMATION HEREIN JOB NUMBER: ,JOven Villaman 10.46613 KW PV ARRAY Alex Webster T 5 L n CONTAINED SHALL NOT BE USED FOR THE � � BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 426 SE Gasparilla Ave 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34983 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (179) TESLA # SR60T1 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION of TESLA INC. MULTIPLE INVERTERS 5616672896 SITE PLAN 2 7/30/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND N #6 GEC TO N GROUND ROD Panel Number NoLobel 17v 1, DC UngroundedINV I —(1)Delta Electronics #M4—TL—US [24OV] —(70Tesla #SR60T1 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number.ACD1600 Inv 2: DC Ungrounded Inverter; 3840W, 240V, 97.5%Inverter; 3840W, 240V/208V, 97.57, Zigbee Solar Roof PV Module; 58.47W, 52.11W PTC, Textured Underground Service Entrance Tie—In: Supply Side Connection INV 2 —(1)Delta Electronics M8—TL—US [24OV] Inverter; 7680W, 40V, 97.5%Inverter; 7680W, 240V/208V, 97.57, Zigbee Vac: 13,34 vpmax; 10.99 INV 3 1 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL Inverter I E� 20OA/2P MAIN CIRCUIT BREAKER Delta Electronics 13 M4—TL—US [240V] $ B 1 zaov DC+ DC+ DC- Dc- MP2: 28 TO MAIN PANEL L1 AND POINT OF L2 INTERCONNECTION N MP4: 21 EG_G DC+GEC 1 N - MP4: 21_ 'Inverter 29qg Delta Electronics (1 AWG #10, THWN 2, Green EGC 14 M8—TL—US [240V] 77v DC+ � DC+ DC- °c- MP7: 30 DC+ TO MAIN PANEL L1 °C MP7: 30 AND POINT OF L2 DC+ D(;+ INTERCONNECTION N DC- DC- MP7: 19 EGCI DC+ y DC! GEC N DC- °C- MP7: 30 GND __ EGC_ ' — 11 1 4 5 (1)AWG #10, THWN 2, Green EGC CONDUIT MATERIAL TYPE TBD IN FIELD TO CURRRENT NEC STANDARDS DC Conduit Reference Chart CONDUIT MATERIAL TYPE TBD IN FIELD TO CURRENT NEC Qty Conductors Raceway if THWN-2 Raceway if PV Wire STANDARDS <=(5)AWG#10 r EMT or LFMC <=(7)AWG 110 I"EMT or LFMC 1"EMT or LFMC <=(9)AWG#10 1—r EMT or LFMC Voc* = MAX VOC AT MIN TEMP AC B (5)Junction Qox PV (14)Delta #GPI00010114 D V Metal; 6 x6"x4" , Box w/cover; Nema 1 MCI Rapid Shutdown, 60OV, 12A, NEMA 4X, MC4, for Solar Roof A (2)MULTI—CONTACT PV—AZB4 32.0018; Branch Socket; MC4 U—Joint Connector, Female —(2)MULTI—CONTACT PV—AZS4 32.0019; Branch Plug; MC4 U—Joint Connector, Male PT B (5)1 PASS THROUGH BOX, TWO STRING, REWORKED (1)AWG #10, THWN-2, Black Voc* =404.47 VDC Isc =5.65 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =404.47 VDC Isc =5.65 ADC ® (1)AWG #10, THWN-2, Red Vmp =307.72VDC Imp=5.32 ADC O[T Vmp =307.72VDC Imp=5.32 ADC (1)AWG© #10, THWN-2, Black (1)AWG #10, THWN-2, Black Voc* =303.36VDC Isc =11.3 ADC 2 AWG #10, PV Wire, 60OV, Black Voc* =303.36VDC Isc =11.3 ADC 4 AWG #10, PV Wire, 60OV, Black Voc* =303.36VDC Isc =5.65 ADC� L(1)AWG #10, THWN-2, Red O (1)AWG #10, THWN-2, Red Vmp =230.79 VDC Imp=10.64 ADC ©� Vmp =230.79 VDC Imp=10.64 ADC O[F Vmp =230.79 VDC Imp=5.32 ADC IIIL LLLL(1)AWG #10, THWN-2, White Vmp =240 VAC Imp=16 AAC 1 AWG #10, THWN-2, Green EGC —(1)Conduit Kit; 3/4" EMT (1)AWG #10, THWN-2, Black Voc* =433.37 VDC Isc =11.3 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =433.37 VDC Isc —11.3 ADC (4)AWG #10, PV Wire, 60OV, Black Voc* =433.37 VDC Isc =5.65 ADC k1)AWG ®�(1)AWG 10, THWN-2, Red Vmp =329.70VDC Im 10.64 ADC O Vmp =329.70VDC Im 10.64 ADC O Vmp =329.70VDC Im 5.32 ADC � #8, THWN-2, Block � ( ) # P P= P P= L J P P= ®13�(1)AWG #8, THWN-2, Red II LL(1)AWG #10, THWN-2, White Vmp =240 VAC Imp=32 AAC (1)AWG #10, THWN-2, Black Voc* =274.46 VDC Isc =5.65 ADC ®[F(2)AWG #10, PV Wire, 60OV, Black Voc* =274,46 VDC Isc =5.65 ADC —(l)AWG #10, THWN-2, Green EGC —(1)Conduit Kit; 1" EMT © (1)AWG #10, THWN-2, Red Vmp =208.81 VDC Imp=5.32 ADC Vmp =208.81 VDC Imp=5.32 ADC (1)AWG #10, THWN-2, Black Voc* =433.37 VDC Isc =5.65 ADC (2)AWG #10, PV Wire, 60OV, Black Voc* =433.37 VDC Isc =5.65 ADC ® (1)AWG #10, THWN-2, Red Vmp =329.70VDC Imp=5.32 ADC O[F Vmp =329.70VDC Imp=5,32 ADC J B-3 4 9 2 3 8 O O CUSTOMER: DESCRIPTION: DESIGN: CONTAINED AL — THE INFORMATION HEREIN JOB NUMBER: ,JOven Villaman 10.46613 KW PV ARRAY Alex Webster T � 5 L n CONTAINED SHALL NOT BE USED FOR THE � BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: � SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 426 SE Gasparilla Ave 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34983 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (179) TESLA # SR60T1 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. MULTIPLE INVERTERS 5616672896 THREE LINE DIAGRAM 3 7/30/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES LICENSE BOND (N) AWG #6 TO (N) GROUND ROD Panel Number: AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:ACD1600 Overhead Service Entrance E 125A MAIN SERVICE PANEL E 125A/2P MAIN CIRCUIT BREAKER (N) 125A LOAD CENTER (E) WIRING AUTOMATIC RELAY 17 Y Z 125A 2P 125A 2P 20Al2P TO NEW SOLAR N G r-- 1 I I J I I I I I I I I OAf2P I I I I I I TO NEW I I I SOLAR I I 15 I I OAl2P I EGC N L2 L1 I Ll I I i L2 X ENERGY I I N STORAGE I Z I ,,,, L———— EGC SYSTEM TO 120/240V i I OAl2PtEGEC SINGLE PHASE I i ENERGY Ll UTILITY SERVICE I 125A 2P i STORAGE SYSTEM I I • I • I (E) LOADS I I I (E) 125A ISTRIBUTION PANEL O1 (1)Gro rLd Rod (1)AWG #2, THWN-2, Black A 5r8 x 8, Copper ©L-L(1)AWG #2, THWN-2, Red H Z (1)Tesla #1 2 321 00-00—E L-L(1)AWG #2, THWN-2, White Back—up Gateway 2.0 NA for AC PW 2.0 _(1)AWG #6 THWN-2, Green —(1)Conduit Kit; 1-1/4" EMT —(1)Eaton CSR2125N (1)AWG #10, THWN-2, Black # 125A B; 2—Pole, 240V, 25kAIC, For Convertible Load Centers ®�(1)AWG #10, THWN-2, Red Y (1)SLLoadRCennteer�25ACon1vertibe,NEMA3R,12sp/24Cir,120v/240v,10kAIC,Surface (1)AWG 10, THWN-2, White —(1)SQUARE D #HOM2125 —(1)AWG #10, THWN-2, Green —(1)Conduit Kit; 1" EMT Breaker; 1 5A 2P, 2 Spaces (1)AWG #2, THWN-2, Black —(1)SQUARE D #HQM220 In��(1)AWG #2, THWN-2, Red Breaker; A 2P, 2 Spaces 6F(1)AWG #2, THWN-2, White —(1)SQUARE D t P, 2 Spaces HQM240 —(1)AWG #6, THWN-2, Green —(1)Conduit Kit; 1-1/4" EMT Breaker; 4 A 2 —(2)SQUARE D #HQM230 Breaker; A 2P, 2 Spaces —(1)SQUARE D tit; Retaining tit; 10OA-125A Convertible LCs, Series S01 & S02 X (2)1092170-05—J TESLA AC POWERWALL 2.0; Home Energy Storage,13.5KWH, Stackable, 5.8kVA J B-3 4 9 2 3 8 O O CUSTOMER: DESCRIPTION: DESIGN: CONTAINED AL — THE INFORMATION HEREIN JOB NUMBER: ,JOven Villaman 10.46613 KW PV ARRAY Alex Webster T 5 L n CONTAINED SHALL NOT BE USED FOR THE � � BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 426 SE Gasparilla Ave 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34983 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (179) TESLA # SR60T1 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. MULTIPLE INVERTERS 5616672896 THREE LINE DIAGRAM 1 4 7/30/2020 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN Battery storage utilized at this facility TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY Address: 426 SE Gasparilla Ave TESLA SOLAR ROOF ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM Front of Hous INVERTER AND DC DISCONNECT UTILITY SERVICE INVERTER AND DC DISCONNECT OPERATING VOLTAGE = 240 JB-349238-00 Note: Used on Delta String Inverters Yellow background on top, white background on card bottom a back text and Images Custom site plan Custom site plan placard J B—3 4 9 2 3 8 0 0 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED AL — THE INFORMATION HEREIN JOB NUMBER: ,JOven Villaman 10.46613 KW PV ARRAY Alex Webster T 5 L n CONTAINED SHALL NOT BE USED FOR THE � � BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN TESLA SOLAR ROOF 426 SE Gasparilla Ave 27 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie FL 34983 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (179) TESLA # SR60T1 TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. MULTIPLE INVERTERS 5616672896 SITE PLAN PLACARD 5 7/30/2020 WARNING:PHOTOVOLTAIC POWER SOURCE Label Location: - ' WARNING Label • 'Location: WARNING Label Location: I ' Code:Per Code: NEC ELECTRIC SHOCK HAZARD • ELECTRIC SHOCK HAZARD 690.31.G.3 NEC 'DO NOT TOUCH TERMINALS 1 13 THE DC CONDUCTORS OF THIS LabelTERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE PHOTOVOLTAIC DC LOADN TH OPEN POS TIONIZED MAY BEOENERG ZED DISCONNECT Per NEC ••1 Location:.113.13 Label LabelLocation: PHOTOVOLTAIC POINT OF MAXIMUM POWER-_ (INV) Per INTERCONNECTION _ POINT CURRENT(Imp) A • Code: WARNING: ELECTRIC SHOCK •� MAXIMUM POWER Per HAZARD. DO NOT TOUCHCEC 690.13.13 POINT VOLTAGE(Vmp)_VNEC 690.53 TERMINALS.TERMINALS ON MAXIMUM SYSTEM BOTH THE LINE AND LOAD SIDE VOLTAGE(Voc)_V MAY BE ENERGIZED IN THE OPEN SHORT-CIRCUIT POSITION. FOR SERVICE CURRENT(Isc)_A DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC A OPERATING CURRENT MAXIMUM AC LabelPer OPERATING VOLTAGE V WARNING ..- ELECTRIC SHOCK HAZARD 690.41.13 IF A GROUND FAULT IS INDICATED NORMALLY GROUNDEDLabel L• • CONDUCTORS MAY BE CAUTION UNGROUNDED AND ENERGIZED DUAL POWER SOURCEPer Code: NEC SECOND SOURCE IS 1 5.12.13.3 PHOTOVOLTAIC SYSTEM Label • • WARNING Per Code:ELECTRICAL SHOCK HAZARD _ DO NOT TOUCH TERMINALS 691 = CAUTION ' '_ •Location: TERMINALS ON BOTH LINE ANDPer Code: NEC LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM 690.64.B.4 IN THE OPEN POSITION CIRCUIT IS BACKFED DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT Label • • Per WARNING ..- INVERTER OUTPUT Label Location: CONNECTIONNEC 1 P H OTOVO LTAI C AC sconnec DISCONNECTPer Code: THIS ODEV CERRENT (C): Conduit NEC •.1 :. Conduit(D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Label AC ' '• OPERATING CURRENT Load "d Per Code: MAXIMUM AC OPERATING VOLTAGE VNEC 690.54 POWERWALL TYPICAL SYSTEM LAYOUTS Tesla Powerwall is a fully-integrated AC battery system for T — 6 L WHOLE HOME BACKUP residential or light commercial use. Its rechargeable lithium-ion rq battery pack provides energy storage for solar self-consumption, optional'' time-based control, and backup. Powerwall's electrical interface provides a simple connection to Solar any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling owners to quickly realize the benefits of reliable, clean power. o Solar inverter --- Main panel Backup Gateway Utility meter Grid including service disconnect T=5 L n PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240 V Dimensions' 1150 mm x 753 mm x 147 mm Feed-In Type Split Phase (45.3 in x 29.6 in x 5.75 in) O^ Weight' 114 kg(251.3 Ibs) Grid Frequency 60 Hz Mounting options Floor or wall mount Total Energy' 14 kWh Powerwall Whole home 'Dimensions and weight differ slightly if manufactured before March 2019. backup Usable Energy' 13.5 kWh Contact Tesla for additional information. 753 mm 147 mm Real Power,max continuous2 5 kW(charge and discharge) (29.6 in) (5.75 in) Real Power,peak(10s,off-grid/backup)' 7 kW(charge and discharge) Apparent Power,max continuous 5.8 kVA(charge and discharge) Apparent Power,peak(10s,off-grid/backup)7.2 kVA(charge and discharge) T o M 1- n PARTIAL HOME BACKUP Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Optional Overcurrent Protection Device 30 A 1150 mm I 45.3 in) Imbalance for Split-Phase Loads 100% � Power Factor Output Range +/-1.0 adjustable Solar Power Factor Range(full-rated power) +/-0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency',3 90% � o 0 o O Warranty 10years ENVIRONMENTAL SPECIFICATIONS O 'Values provided for 250C(770F),3.3 kW charge/discharge power. Solar Inverter In Backup mode,grid charge power is limited to 3.3 kW. Operating Temperature -200C to 500C(-4°F to 122°F) Sub panel Backup Gateway Main panel Utility meter Grid 3AC to battery to AC,at beginning of life. Recommended Temperature 0°C to 300C(320F to 86°F) COMPLIANCE INFORMATION Operating Humidity(RH) Up to 100%,condensing - Storage Conditions -200C to 300C(-4°F to 86°F) Certifications UL 1642,UL 1741,UL 1973, Up to 95%PH,non-condensing UL 9540,IEEE 1547,UN 38.3 State of Energy(SoE):25%initial ^n Grid Connection Worldwide Compatibility Maximum Elevation 3000 m(9843 ft) O fnl�n Emissions FCC Part 15 Class B,ICES 003 Environment Indoor and outdoor rated Enclosure Environmental RoHS Directive 2011/65/EU Type NEMA 3R Powerwall Backup loads Home loads Seismic AC156,IEEE 693-2005(high) Ingress Rating IP67(Battery&Power Electronics) IP56(Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C(86°F) T = 5 L Fi TESLA.COM/ENERGY T NA-BACKUP-2019-06-11 TESLA.COM/ENERGY T - 5 L_ Fi ROOFING SYSTEM SPECIFICATIONS CERTIFICATIONS UL Listed ETL Listed SOLAR ROOF UL 61730 UL 790 Class A UL 9703 TAS100 D A T A S H E E T UL 1741 ASTM D3161 Class F ELECTRICAL CHARACTERISTICS Maximum open circuit voltage rating of connected branch circuits per diode (at STC): 13.34 V Maximum series fuse rating: 10 A Maximum system voltage: 600 V ROOF PITCH RANGE 2:12 -20:12 MODULE SPECIFICATIONS MODEL #SR60T1 14-CELL MODULE Irradiance Temp. Voc Vmp Isc Imp Pmax (W/m2) (Celsius) (V) (V) (A) (A) (W) F Y 1000 25 13.34 10.99 5.65 5.32 58.47 3- �a14` , ' These electrical characteristics are within±5%of the indicated values of Isc,Voc,and Pmax under standard test conditions (irradiance of 1000 W/m2,AM 1.5 spectrum,and a cell temperature of 25°C or 77°F). I -.+sm i Dimensions 430 mm x 1140 mm Appx. 5 mm module thickness with 35.3 mm maximum height from deck Principal Materials Glass, Polymers, Fiberglass and Silicon Installed System Weight Textured Glass: 16.4 kg/m2 or 3.4 psf Installed weights include all components of system above roof sheathing 1551586-00-E ROOFING MODULES, FULL AND PARTIAL PV MODULE Model#SRNFT1/6,#SRNFT1/3,#SRNFT1/2, Model#SR60T1 #SRNFT2/3,#SRNFT5/6 and#SRNFT1 Listed to UL 61730 Listed to UL 61730 UL 790 Class A Listed to UL 790 Class A ASTM D3161 Class F ASTM D3161 Class F TAS100 TAS100 > 5> FOOT WITH SUPPORT FOOTLAP Model#SR-FOOTSUP Model#SR-FOOTLAP Listed to UL 790 Class A Listed to UL 790 Class A ®® ASTM D3161 Class F ASTM D3161 Class F TAS100 TAS100 ti i 00 Center foot for PV module Edge foot for PV module MCI RAPID SHUTDOWN UNDERLAYMENT Model#EE-002605-003,Delta#GPI00010110 FT Cobalt FR 600V,12A,NEMA4X,MC4 ASTM D1970/ICCAC48 Listed to UL 1741 PVRSE ICCAC188 ASTM E108 Class-A MOM" < DIODE TRUNK HARNESS PASS THROUGH BOX Model#SRDTH Model#SRPTB-4 Listed to UL 9703 Listed to UL 1741 w ROOFING FOOT BRANCH JUMPER Model#SR-FOOT Model#SR-BJ2X,#SR-BJ3X,#SR-BJ4X,and#SR-BJMini Listed to UL 9703 Center foot for Roofing module T = 5 L n 1551586-00-E SOLAR ROOF DATASHEET 3 Ah E LTA Solar Inverter for North America AhELTA Solar Inverter for North America Model M4-TL-US M5-TL-US M6-TL-US I M8-TL-US M10-TL-US M10-4-TL-US Single Phase Solar Inverter for North America INPUT(DC) M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US Max.system voltage I 600V Nominal voltage 380 V Max.operating voltage 540 V Operating MPPT voltage 50 V to 480 V range Max.input current per 12 A 12 A 12 A 12 A 20 A 10 A MPPT Max.short circuit current per MPPT 15 A 15 A 15 A 15 A 30 A 15 A a Max.DC/AC ratio 1.3 DC disconnect Integrated MPP tracker 2 2 3 3 2 4 Input strings available 2-2 2-2 2-2-2 2-2-2 2-2 2-2-2-2 TPUT(AC) Nominal output power 240Vac 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W Max.output power 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W 240Vac Nominal output power 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W 208Vac Max.output power 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W 208Vac AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max.continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating 60 Hz frequency Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption <1.5 W 1) THD @ nominal power <3% Power factor @ nominal >0.99 power Adjustable power factor 0.85i to 0.85c range GENERAL SPECIFICATION Key Features. Max.efficiency 98% CEC efficiency 97.0%@ 208 V 97.5%@ 208 V 97.0%@ 208 V 97.5%@ 208 V 97.5%@ 208 V 97.0%@ 208 V • Smart inverter with BILE, optional WiFi, Ethernet, 3G /4G cellular 97.5%@240V 97.5%@240V 97.5%@240V 97.5%@240V 97.5%@240V 97.5%@240V communication Operating temperature -22°F to 149°F(-30°C to 65°C) • Optional revenue grade meter (compliant with ANSI C12.20, Class 0.5) range with derating above 113°F(45°c) Storage temperature range -40°F to 185°F(-40°C to 85°C) • Support bi-directional cloud communication Humidity 0%to95% • Support remote diagnosis and OTA Max.operating altitude 9,843ft(3,000 m) • Type 4 protection Acoustic noise <45 dB(A)@ 3 ft(1m) • Built-in AFCI & Rapid shutdown controller • CEC efficiency 97.5% • UL 1741 SA, HECO compliant • CA Rule 21 Phase 1 & 2 & 3 compliant Rev 14-02/2020 ©Copyright 2020 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change without prior notice. ANELTA Solar Inverter for North America Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US MECHANICAL DESI Dimensions(W x H x D) 16.7 x 23.2 x 5.9 in(425 x 590 x 150 mm) Display LED indicators Weight 2) 41.9lbs(19.0 kg) 41.9lbs(19.0 kg) 44.3 Ibs(20.1 kg) 45.2 Ibs(20.5 kg) 47.6lbs(21.6 kg) 47.6 Ibs(21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Rapid Shutdown Initiation Loss of AC or DC Disconnect Method Communication interface BILE,optional WiFi,Ethernet,3G/4G cellular communication Enclosure material Die-casting aluminum STAND Enclosure protection rating Type 4 Safety UL 1741,CSA-C22.2 No.107.1-01 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547,IEEE 1547.1 EMC FCC part 15 Class B AFCI UL 1699B(Type 1),NEC 2017 Article 690.11 Rapid shutdown protection NEC 2017 690.12 3) Integrated meter ANSI C12.20,Class 0.5 Grid support regulation UL 1741 SA,California Rule 21 phase 1 &2&3,HECO Compliant Standard warranty 10 years 1) Without consumption of communication card e 2) Without weight of revenue grade meter �7 3) Compliant with Tigo rapid shutdown system or APS rapid shutdown system C US Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont,CA 94538 Sales Email:Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline:+1-877-440-5851 or+1-626-369-8021 Support Hotline:+1-877-442-4832 Support(Intl.): -626-369-8019 AI�E LT�I Monday to Fridayay from Gam to 6pm PST(apart from Holidays) www.Delta-Americas.com Rev 14-02/2020 @ Copyright 2020 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change without prior notice. ANELTA Residential Energy Storage Solution for North America Accessory: MCI (Middle Circuit Interrupter) Features: • Automatic function test upon startup,ensure safety • Enclosure protection Type 4 • Meet 2017 NEC Article 690.12 Rapid Shutdown • No installation needed for every PV Module, make better cost performance for PV system • With PLC,no additional cable needed INPUT RATINQJ Delta part number GPI00010110 GPI00010114 Maximum system voltage 600 Vdc Rated input operating voltage 6 Vdc to 80 Vdc Number of input circuit 1 Startup voltage 22 V Rated input current 12 A PUT RATINGS Rated output current 12 A Control signal method PLC signal Dimensions(W x H x D) 4.6x6.5x3.0in(117x165x76.5mm) 3.8x6.5x1.1 in(97.3 x 165 x 27.3 mm) (without cable) (without cable) Weight 2.0 Ibs(0.9 kg) 1.4 Ibs(0.64 kg) Bracket Groove adapter bracket Without Cooling Natural convection DC input/output connectors MC4 PV connector Cable length with connector Input:5.9 in(150 mm) Input:5.9 in(150 mm) Output:47.2 in(1200 mm) Output: 12 in(305 mm) Enclosure material Plastic Operating temperature -40 T to 185 T(40°C to 85°C) Storage temperature -40 T to 185°F(40°C to 85°C) Humidity 0%to 95% Maximum operating altitude 9,843 ft(3,000 m)above sea level Self power consumption <3.0 W Warranty 10 years ST ARD COMPLIANCE Enclosure protection rating Type 4/IP67 Safety UL 1741,CSA C22.2 No.330-17 Rapid shutdown NEC 2017 Article 690.12 EMC FCC Part 15 Class B Rev 05—09/2019 ©Copyright 2018 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change without prior notice. POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management and monitoring for solar self-consumption,time-based control,and backup. The Backup Gateway 2 controls connection to the grid,automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker,the Backup Gateway 2 can be installed at the service entrance.When the optional internal panelboard is installed,the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall,allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240V Dimensions 660 mm x 411 mm x 149 mm Feed-In Type Split Phase (26 in x 16 in x 6 in) Weight 20.4 kg(45 lb) Grid Frequency 60 Hz Mounting options Wall mount,Semi-flush mount Current Rating 200 A Maximum Input Short Circuit Current 10 kA' Overcurrent Protection Device 100-200A;Service Entrance Rated' Overvoltage Category Category IV AC Meter Revenue accurate(+/-0.2%) Primary Connectivity Ethernet,Wi-Fi 4 e S L R Secondary Connectivity Cellular(3G,LTE/4G)2 User Interface Tesla App Operating Modes Support for solar self-consumption, time-based control,backup,and o off-grid Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space/12 circuit Eaton BR Circuit Breakers Warranty 10 years 'When protected by Class J fuses,Backup Gateway 2 is suitable for use in 411 149 circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2;cellular should not be used as the primary mode of connectivity.Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Certifications UL 67,UL 869A,UL 916,UL 1741 PCS Operating Temperature -200C to 500C(-4°F to 122°F) CSA 22.2 0.19,CSA 22.2 205 Operating Humidity(RH) Up to 100%,condensing Emissions FCC Part 15,ICES 003 Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R T = 5 L Fi NA 2020-05-23 TESLA.COM/ENERGY T = SLM 1 � GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (690.12.B.2.1) C7� • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ DIODE DIODE DIODE DIODE DIODE DIODE DIODE DC- SOLAR ROOF TLES MCI 1 DIODE DIODE DIODE DIODE DIODE DIODE DIODE • MCIS ARE LOCATED AT DECK LEVEL, JUST UNDER THE TILES IN ACCORDANCE WITH 690.12 REQUIREMENTS • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH DIODE DIODE DIODE DIODE DIODE DIODE DIODE — MCI INPUT = 3-5 TILES M�' — NUMBER OF TILES BETWEEN MCI UNITS = 0-10 — MAXIMUM NUMBER OF TILES PER MCI UNIT = 15 — MINIMUM NUMBER MCI UNITS = TILE COUNT/15 DIODE DIODE DIODE DIODE PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR 1 (2)AWG, PV Wire, 600V, Black DC MORE INFORMATION