Florida Building Code Toth Edition (201-1) Energy Conservation
C4025,5 Recessed lighting,
Recessed luminaires installed in the building thermal envelope
shall be all of the following:
I, IG-rated,
2,Labeled as having an air leakage rate of not more 2,0 cfm
(O.S44 L/s) when tested in accordance with ASTM E253 at a 1,51
psf (15 Pa) pressure differential,
3,5ealed with a gasket or caulk between the housing and
interior wall or ceiling covering,
(See Section C402,5.9 applicable Building cavities)
C402,5.9,1 Vented dropped ceiling cavities,
C402,5,9,2 Unvented dropped ceiling cavities,
C402,5,9,3 Separate tenancies,
C402,5,9,4 Air distribution system components,
LOAD CALCULATIONS
EXIST. SERVICE FEEDER:
250 AMP
EXIST. PANEL SIZE: (1)
42 CIRCUIT
(VERIFY)
EXISTING LOADS
3113 5 Q, FT, x 3 WATT =
9,33-B Watts
2 SMALL APPLI, a 1500
3000 Watts
1 LAUNDRY
1500 Watts
1 RANGE
8,000 Watts
1 DISHWASHER
1500 Watts
1 DISPOSAL
1500 Watts
1 MICROWAVE
2000 Watts
1 WATER HEATER
4500 Watts
1 DRYER
5000 Watts
OTHER
OTHER
OTHER
SUB TOTAL:
36,339 Watts
NEW LOADS
149 SQ, FT. x 3 WATT =
441 Watts
166 SQ, FT, x 3 WATT =
498 Watts
OTHER
OTHER
OTHER
TOTAL WATTS: 3-1,284 Watts
1ST 10 KW w 100% (x2) 11,500 Watts
REMAINDER Q 40% TB13 Watts
A/C HEAT a 100% 10,000 Watts
TOTAL WATTS 35,413 Watts
DIVIDED BY 240 VOLTS = NEW 114-1.5 Amps
EX15TING 250 AMP
POWER SUPPLY SUFFICIENT.
2014 NEC 210,12 (A)
Arc -Fault Circuit -Interrupter Protection,
Dwelling Units, All 120-volt, single phase, 15- and 20-ampere
branch circuits supplying outlets installed or devices in II
unit kitchens, family rooms, dining rooms, living rooms, pa r ,
libraries, dens, sun rooms, recreation rooms, closets, hallw
laundy areas or similar rooms or areas shall be protected
any of the means described in the NEC 2011 210,12 (A)(1)
through (C )
2014 NEC 406,12
Tamper -resistant receptacles in are required in dwelling I nits in
all areas as specified in 2014 NEC 40�o,12(A) through lC
All 125-volt, 15- and 20-ampere receptacles, 1
ELECTRICAL LEGEND
ELECTRICAL
SYMBOL
Can Light
Disconnect
di6c
Pendant Light
Push Button
PB
4
outlet
outlet 220v
outlet gifi(}i
`
switch
$
switch 3 way
$3
wall light exterior
THIS -
NOT PART Of=
THIS PERMIT
----------------------
Tb exist, garage light circut,
�e
.� NEW PANELS 8 NEW
PANEL LOCATION - a
________ _____�_ ___ VERIFY ON THE JOB `
Panel Panel Ll
0-
CD
OL
DN,
I�
I I I I I I
(0
TANKLESS
NEW - VERIFY
LOCATION
1 1
I I
1 1
I I
1 1
11111� M .
I
- - - \To-Lig� t IAbove
W e
" I I
----------1 I
' W,H, \I I ELEVI I
}El
1 1 1 1 11 I
I I I I I I
disc i , AC
TANKLESS
W,H, (CAA
° F
sc,
i
U
U I O U
z p
� o}
z-C � N z
o o rn O
�Q n
a `32-az'
O".
"'�1� Q�"'9
z�
0
zz
'_„��u��o
�o
717
sQ) N�
iy N V" t
ILO
IL
�
iL
UUIL4
3 O O Q m
m ��
�N
DATE : 10/23/20
DRAWN BY: pig me
CHECKED Mc
REVISIONS
11/30/20 PER B.D
\2/1/21 WORK AREA
�2/15/21 NEW PERMi