HomeMy WebLinkAboutREVISION, 01) 1st floor plan, 2.22.21EXIST POOL WALL
1
no ♦ 1
EXIST, RD. WIN, -
NEW F,G. RD, WIN,
(MATCH EXIST, SIZE)
D Elul
♦ REMOVE EXIST,
FIR, DR, 8 S,L. -
NEW SL. GL, DR,
19,
o,,
O v
NEW PRE- F B. MTL,
FIREPL E - VERIFY NEW
FINIS W/ OWNER
I
A�
I
NEW ROLL-DN
I SCREEN FOR
I OPN'G, (4 PLACES)
I
I
I
I
AHU ON SHELF - REMOVE
EXIST, W.H. (BELOW) - ADD
TANKLESS (GAS) W.H. TO
OUTSIDE
LIVING ROOM
FLAT CLG,
GENERAL ADDITION NOTES:
*THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE
EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION
BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR),
*OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING
CONSTRUCTION.
*EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE
VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR)
EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM
MATERIALS, ROOFING MATERIALS, FASCIAS, ETC,
-OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE
FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND
RESTRICTIONS PER SUBDIVISIONS ARCHITECTURAL REVIEW BOARD.
*M,A, CORSON d ,4550C, INC, SHALL NOT BE LIABLE FOR ANY LOSS,
DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES,
*CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR
LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS
OR EASEMENTS ARE ENCROACHED, (OWNER, d OR
— — — — — — — — ` CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS,
EASEMENTS, LOT COVERAGES, ETC,)
\
S, \
+ \ \
o,, \ \
O \ \
c0 \
x \
<>\\
21 x a o coy'r \
+8' ENTRY \ \ \ \
O,, \ \
\
0
/REMMVE EXIST, \
g, p,, / CAST STONE TRIM - \
N TP +� ADD STUCCO TRIM \
OYER \
■ REPLACE (2) S,H,\ \
WIN, W/ NEW \
F.G. - VERIFY \
+8, SIZE (a PLACES)
co,,
\ 0o� I I
\ \ co I I
\ \ x I I
\ 2'
RD, GONG,
COL,
+& irT�
I I kn
I I
I I 0
I I Q
IV IV DINING ROOM
I 144
I I
--- I 10-
1 �
q
* I I
I I �
I I
EXIST, SOFFIT ABV, - - _.TO REMAIN
REMOVE EXIST,
SUMMER KIT, �~
25' 4" SUMMER
& SINK)
REMOVE EXIST,
N,R. WIN, - NEW
LARGER II'O"x5'O"
F.G. WIN, - VERIFY
DTH
EXIST, CONC.IWALL COLS.)
<1
SCREENED
I '
�O�C1"f
\ 9'O" CLG, HT, \
2 \ \ / / - \\\
NEW STUCCO ON Q
BLK, RETAINING p
WALL - MATCH LL
EXIST, SEE DETAIL W ON SI-IT, 6 >\ �W;
9' I I/16" a' IIS%"
00
o+
°j REMOVE EXIST,
FR. DR. d S,L, -
NEW FOLDING GL, DR,
l' 11 5/16"
REMOVE EXIST,
S,H, WIN, - NEW
S'O"x6'O" F,G. WIN,
VERIFY SIZE
TF - L----�
0
------ j u MIR o 0
---�- O
1
1
1
1 '
1 '
1 '
1
1
° KITCHEN
REOEE EXIST, 6cFFi r6
1 1
1 1
3
REVEE EXIST,
NON-BRG, WALLS
-; -----,
-z.--------------------
`TRA44
MORNING RM.
9'O" CLG, HT,
3' 1"x6'4"
SH 26
E. o"
5 411
3' 1"x6'4"
SH 26
5' O"
A
(K T
x6IOil
F,G,
TANKLESS
W.H, (GAS)
NEW - VERIFY
LOCATION
T' 6
WALL LEGEND
F.S.C. 201-1 (&TH EDITION) FOi�
EXISTING 5ULDING5
SUMMARY:
THE ALTERATION AREA HAS BEEN
DESIGNED TO: LEVEL 2
* Chapter 5 of the FBC 2011 Existing Building
* less than 50% of the aggreregate area
* The lateral -force -resisting system of the existing
structure is adaquate to withstand any new lateral
loads of the new addition per Section 6301,5 of the
2011 FBC Existing Buildings.
* The existing residence has hardwired smoke alarms and
the new addition shall be hardwired and interconnected
to the exist, system where accessible Per R314,3
2011 FBC,
THE ADDITION HAS BEEN DESIGNED TO: CHAPTER 8
*Chapter 5 of the FBC 2011 Existing Building
B 2011 FBC 8 CHAPTER 6 OF ASCE 1-10
HOLLOW d HATCHED =
EXISTING WALL TO REMAIN
SOLID = NEW WALLS
DASHED = EXISTING
- - - - - - - - - - WALL TO BE REMOVED
AREA CALCULATIONS
Exist. let Floor a/c
3,405 S,F,
Exist, 2nd Floor a/c
1,301 S,F,
NEW 2nd Floor a/c
544 S,F,
Total A/C
5,250 S,F,
Garage
1,109 S,F,
Covered Patio
5163 S,F,
Total Non A/C
1,621 S,F,
Total Under Roof
ro,BZI S,F,
* Contractors to verify all
footages
* All areas are calculated to
outside dimensions,
THIS ,4�'E4 -
NOT PART OF
I NS PERMIT
SH 36
4' 5" x 6' 4"
I I
I I
I I
I I
R45
4 O
EXIST
STL.
COLS,
13' O"
5EDROOM 2
5'oil x5,31,
EXIST, H.R. (IMPACT)
(TO BE PAINTED WHITE)
4'0"x6'0"
F.G. W/ TRANS,
VERIFY SIZE
----------------------
i
I
GOLF CAIRT
ro I
1 9'O" CLG, AT,
I'
----------------------
- - - i
I
I
I
-----------------------'
I
1 GARAGE
1 ; 9'10" CLG, HT, 0
5'2" ABV, (O'O' ,F,F) h
I'
o
I '
m
I'
I
I
I
I
I
I
1 '
8" � 24' O"
I
-�'4" FIN, FL. �
VARIES GUT BAG
NEW 8 GONG, STEP a
; RELOCATED
Panel BACK TO _
-------------- --- -
Panel NEW WALL
-- ---- ------ -
,-
00,
_1-,
2' S" a
FIN, FL. RELOCATED
4' 6 3all UP
O
O
- in
Q
REMOVE EXIST, SH 36 , 1 O 6" �n RELOCATED
4' S x 6' 4 2' 6'l
QUAD.WIN. - NEW 7s - - - - - - - - -
a
H r EXIST, p = __________
I I 1 STEPS D,
I > ----------
I I OO FIN -'.FL, O -A --- -
1I,I O 3' 8" 5' Imo"--31,_==-! I 4 6
-.8
I I
N
--- --1 -T- 1 OEI v
1 1 1 1 N
M DIFY FLAT GD 1 1 1 EQUIIF, I I -x z
A 3V, (FL, DEPTH) '' RfiMO1VE I I 6,
2ND FL WALL ABV,
RELOCATE
EXIST, VAC
- - EXIST, - - - - 1
USTL. 1 1 1 11 1 , 0
_ L _ COL,
0 — — — ff
SO z
r m 510 — 4'6" wlu
L.T,
AG 8"
Film
13' O" 5101, dL
' W' 1.0
5EDROOM 3
OMIT SINK s ADD CAB, W/ I
KNEE SPACE I I
I
LINE OF BALCONY COLS, / I I O
[PIERS ABV, TO BE REMOVED
(8 PLACES)
1 �
5'oil x5,31,
EXIST, H.R. (IMPACT)
(TO BE PAINTED WHITE)
BATH 3
TANKLESS
W,H, (G,4Sd.
U
Q
0.
NEW FREE
STANDING N
TUB
w ii
on �-
EXIST, IMPACT
F,G.
EXIST, BLK, PRIVACY WALL
B
13
U
U ID U
z o
O>
z)
0 0 s z O
�Q n
.4 32 0 ID a�'
O„
-U, I Q�m9
z
~ O
Q)
z - Q) Q--)z o
(3— Q)O
3
n'
Q) c Q
N'6 u " -c 13
ILO
`` U
OIL
Q) +'
c u
Q
3 m Q m
•
� C/1
N A
�j M v
�."
C U� rA
N Q
dN 3
Z � �
O W1
TOE W1
r1 F N .PM
po
O
x
• U
DATE 10/23/20
DRAWN BY pig me
CHECKED Mc
REVISIONS
11/30/20 PER 8.D
2/I/21 WORK AREA
2 /15/21 NEW PERMf