Loading...
HomeMy WebLinkAboutProduct Approval 9/20/20'17 Florida Building Code Online BCIS Home ! Log In i, User Registration ! Hot Topics ( Submit Surcharge j Stats&Facts ! Publications FBC Staff 1 BCIS Site Map Lir Florida 3� �Product Approval oft& ., USER:Public User _ � r � . Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL19621 Application Type New Code Version' 2014 Application Status Approved THESE PLANS AND ALL PROPOSED WORK Comments ARE SUBJECT TO ANY CORRECTIONS Archived REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE COOSS, Product Manufacturer Sunlast Metal Address/Phone/Email 2120 SW Poma Drive Palm City, FL 34990 (772) 223-4055 CONCEALED FASTENERS®o-A ATTACHMENTS flvalidation@yahoo.com ARE THE RESPONSIBUTY OF THE Authorized Signature Terry Kapron COW3 OF RECORD flvalidation@yahoo.com Technical Representative Address/Phone/Email / 0f;ssd.?Z5— ST.LUCTE COUNTY BLTLDLIG DP'ISION Quality Assurance Representative REVIEWED FOR C \CE R WIEWED BY i Address/Phone/Email DATE PLANS E1R- nT MUST BE KEPT®\'JOB Category Roofing OR NO INSPECTION WILL BE'MADE. Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licer Professional Engineer j Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 03/02/2026 Validated By Zachary R. Priest, P.E. a: ValidV'gpeh@'cltl�t�i rdcopy Received Certificate of Independence FL19621j6'COI FL 17701 Sunlast Metal ssr.pdf Referenced Standard and Year(of Standard) Standard Year. TAS 100 1995 TAS 125 2000 TAS 125 2003 i Equivalence of Product Standards https:/Avww.floridabuilding.org/pr/pr appi dtl.aspx?param=wGEVXQwtDgtA%2fGGFsMxvHNQgk6GRNt8kduX9Ye74PcXH17%2bti8c9lg%3d%3d 1/2 9/20/2617 Florida Building Code Online Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/18/2015 Date Validated 12/18/2015 Date Pending FBC Approval 12/21/2015 Date Approved 02/10/2016 Summary of Products FL# Model,Number or Name Description 19621.1 "Key West Series" 5-V Crimp -HVHZ 26 GA. HVHZ 24" Width Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL19621 RO II FL 17701 Sunlast Metal ssr.odf Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. # 49704 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +n/a/-189.25 Evaluation Reports Other: -78:5psf @ 16" o.c. -189.25psf @ 8" o.c. Install per FL19621 RO AE FL 17701 Sunlast Metal ssr.Ddf manufacturer instructions and PAS 133 in compliance with FBC Created by Independent Third Party: Yes 2014 For HVHZ use FEE, Alezt Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility statement::Refund Sty Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email addreE one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to su address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Che please click here. Product Approval Accepts: t ® eCteck Credi-t Card' ' Safe https/Awm.floridabuilding.org/pr/pr app Idu.aspx?param=wGEVXQwtDgtA%2fGGFsMxvHNQgk6GRNt8kduX9Ye74PcXH17%2bti8c9lg%3d%3d 2/2 Locke Bowden,P.E. 94SO Alysbury Place. Montgomery,AL 36117 Manufacturer:Sunlast Metal,Inc. FL 17702 2120 SW Poma Drive Palm City,FL 34990 Code Compliance: Florida Building Code 2014 Rule#61G20-3 Category: Roofing Sub-Category Metal Roofing HVHZ "Key West Series" , Product:5V Crimp Metal Roof Panel Support Substrate: 15/32"APA Wood Deck min.over supports at 24"spacing maximum Material 26GA steel Yield Strength 55ksi min. Corrosion resistant: Material to comply with FBC section 1517.6 for HVHZ (Design of support system not included in this report) Panel Dimensions:Thickness-26GA steel Width: 24" Rib Height: 5/8"High rib: 12"o.c Slope:2/12 min. or greater in compliance with FBC 2014;Section 1515.2 Underlayment: In conformance to FBC 2014. Fire Classification: Not within the scope of this report. Fastener:Corrosion.resistant#10-1-1/2" (3/16"min. penetration through support;Wood-Zac XG Fastener, Hex Head w/Neoprene washer-fastener or equivalent In compliance with-FBC Section 1506.6 and 1507.4.4 Insulation: Optional-Rigid insulation board,3" max thickness compliant with FBC 2014 Section 1508.2 Installation: Install per manufactures details and RAS 133 Design,Uplift Pressure:Table A Roof Areas Field Perimeters and.Corners Max. Design Pressure 48.5 psf 189.25 psf Fastener Spacing 16"o.c. 8"O.C. Fastener Size #10 #10 *Maximum Design Pressures include 2:1 Safety Factor Quality Assurance: In accordance with FBC 2014 and Rule#61G20-3: Keystone Certification, Inc.QUA 1824 Code Compliance demonstrated: Florida Building Code 2014 Section 1523.6.5.2.4.1 This report is limited to compliance with the structural wind load requirements of the FBC 2014. Required.wind loads shall be determined per project per FBC 2014 and any rational analysis computation shall be prepared by a licensed design professional. Reference Data: Architectural Testing Inc(TST 1527) #F0755.01-450-18 TAS 125-2003 Architectural Testing Inc(TST 1527) #0412-1017-05 TAS 125-2003 t Architectural.Testing Inc. (TST 1527) #SFMS-001-02-01 TAS 100-1995 PRI Construction Material Technologies(TST5878)AKZC-001-02-01/05 TAS 110-2000 PRI Construction Material Technologies(TST5878)AKZC-001-02-01/05 ASTM B 117-2002 AKZO Nobel Coatings, Inc. Lab Form ASTM G 153 i Locke Bowden,P.E. 9450 Alysbury Place Montgomery,AL 36117 Manufacturer:Sunlast Metal,Inc. FL 17701 2120 SW Poma Drive Palm City,FL 34990 Certificate of independence Locke Bowden,P.E.does not have,not will acquire financial interest in any company manufacturing or distributing products under this evaluation. Locke Bowden,P.E.is not owned,operated or controlled by any company manufacturing or distributing products under this report. Install Detail TYPICAL ASSEMBLY PROFILE VIEW Fastener:#10-1-1/2"WoodZac XG Perimeter/corner fastener spacing 8"o.c Field fastener spacing 16"o.c. sm • Sfe Tafbilm'A" 60 .. eitC/17 R:Ilirpr I ° No. 49704 L&ke gowden,P.E. FL 704 STATE.OF ° s. ' C? <ti