Sht 06 Elec Plan 2021-02-22 Sealed
EL EC T R I CA L L EG EN D PLUMBING PLAN LEGEND LP GAS PLAN LEGEND ELECTRICAL NOTES ONE WAYSWITCH (l LOCATION) 3 THREE WAY SWITCH (2 LOCATIONS) $4 FOUR WAY SWITCH (3 LOCATIONS) $° ONE WAY3WITCH w/DIMMER $F ONE WAY SWITCH TO FAN $A3 THREE WAY SWITCH TO ATTIC (ILLUMINATED WHEN ATTIC LIGHT lS ON) ® PUSH BUTTON FOR DOOR BELL OR GARAGE DOOR OPENER +4211 HEIGHT ABOVE FIN. FLOOR AS NOTED ------------------------ CONNECTIONS FROM SWITCH TO FIXTURE CENTERLINES INDICATE FIXTURE ALIGNMENT �@+42/° DUPLEX RECEPTACLE CLG DUPLEX RECEPTACLE CEILING MOUNTED =@ USB DUPLEX RECEPTACLE COMBO l 20V OUTLET * USB CHARGER 220V RECEPTACLE DUPLEX RECEPTACLE - GROUND FAULT �GFa CIRCUIT INTERRUPTER (SEE NOTES) wRc DUPLEX RECEPTACLE w/WEATHER RESISTANT COVER ® LOW -PROFILE PLUGMOLD SYSTEM (UNDER -CABINET) RH DUPLEX FLOOR OUTLET DIMENSIONS SHOWN E TO SLAB EDGE ® SPECIAL PURPOSE RECEPTACLE GDo F GARAGE DOOR OPENER EQUIPPED w/AUTOMATIC SENSOR (TO COMPLY WITH UL 325 SAFETYAND CONSTRUCTION CODES) EXTERIOR SWITCHED GFCI RECEPTACLE IN wRc SOFFIT (FOR CHRISTMAS LIGHTING) CEILING MOUNT LIGHT FIXTURE CEILING MOUNT PENDANT LIGHT FIXTURE BEVOLO ELECTRIC CEILING PENDANT LIGHT CEILING RECESSED LIGHT FIXTURE CEILING RECESSED LIGHT FIXTURE WITH N ADJUSTABLE ELBOW WALL WASHER TRIM (ARROW DENOTES DIRECTION OF ILLUMINATION) CEILING RECESSED LIGHT FIXTURE @ vP SHOWERS ( VP = VAPOR PROOF) W CEILING RECESSED LIGHT FIXTURE WITH R WEATHER RESISTANT SEAL (EXTERIOR) sc WALL MOUNT SCONCE LIGHT FIXTURE LED STRIP/ RIBBON LIGHTS (BELOW OH CABINET) RLTK RECESSED LIGHTING (_O VANITY TOE KICK (MASTER BATH, BATHS 2 3) EXTERIOR SECURITY LIGHT os EXTERIOR POST LIGHT FIXTURE CEILING RECESSED EXHAUST FAN w/LIGHT vP ( VP = VAPOR PROOF) VENT TO EXTERIOR CEILING RECESSED EXHAUST FAN VENT TO EXTERIOR 2" WIDE FLUSH MOUNT SQUARE Ell LED FIXTURE WITH DIFFUSER LENS 36" WIDE FLUSH MOUNT SQUARE LED FIXTURE WITH DIFFUSER LENS s oP HANGING SHOP LIGHT - 36" WIDE LED FIXTURE WITH DIFFUSER LENS * ADJACENT SWITCHED RECEPTACLE WALL MOUNT CLOSET LIGHT FIXTURE �oR (DOOR = DOOR ACTIVATED SWITCH) 52" DIAMETER EXTERIOR CEILING FAN O (MOUTE CARLO MAVERICK) C==)00 52" DIAMETER INTERIOR CEILING FAN O Rc REMOTE CONTROL D ® DOOR BELL CHIMES MC MEDICINE CABINET ' 1 ON DEMAND WATER HEATER T� PROGRAMABLE THERMOSTAT DUAL SENSOR SMOKE HEAT s"D DETECTOR (CEILING MOUNTED) sco SMOKE * CARBON MONOXIDE DETECTOR UNDERGROUND ELECTRICAL El SERVICE ENTRY POINT DISCONNECT SWITCH 0 ELECTRICAL PANEL BOX GD GARBAGE DISPOSAL - LOCATE SWITCH IN CABINET BELOW SINK A/V SECURITY LEGEND © TELEVISION JACK / COAXIAL CABLE CONNECTION TEL >TELEPHONE JACK CONNECTION ou DATA ROUTER (CAT 5e CABLE) DATA + 42" DATA JACK (CAT 5e CABLE) WALL MOUNT DATA ® DATA JACK (CAT 5e CABLE) FLOOR MOUNT DATA DATA JACK (CAT 5e CABLE) CEILING MOUNT CLG OS CEILING MOUNTED SPEAKER cP� SECURITYSYSTEM CONTROL PANEL C� EXTERIOR (WEATHER PROOF) SECURITY CAMERA METER (SUPPLIED BY UTILITY COMPANY) UNDERGROUND CONDUIT TO UTILITY COMPANY (SUPPLIED BY OWNER) S WATER HEATER (SEE LP GAS LEGEND) HB HOSE BIBS w/NON-REMOVABLE BACKFLOW PREVENTER cw WATER VALVE FOR ICE MAKER WASHER SANITARYSEWER VENT LOCATION O (PLAN VIEW) 4" VTR JIL VENT THROUGH ROOF (SEE RISER SHEET 11 A-5), FLASH AS REQUIRED WALL MOUNT SHOWER HEAD * VALVES CEILING MOUNT RAINHEAD (MASTER BATH ONLY) TILED TROUGH DRAIN (MASTER BATH ONLY) CONCRETE APRON PROVIDE TRANSFER SWITCH TO GENERATOR #4 CU. GROUND TIED TO CW PIPE/ BUILDING STEEL DRIVEN TO GROUND ROD ELECTRICAL RISER DIAGRAM POOL EQUIP POOL EQUIP I. ALL INFORMATION SHOWN WITHIN THIS ELECTRICAL PLAN lS SCHEMATIC IN NATURE. ELECTRICAL MATERIALS AND INSTALLATION SHOULD BE VERIFIED WITH THE CONTRACTOR AND MUST COMPLY WITH THE 201 7 FLORIDA I BUILDING CODE [FBC, 201 7 FLORIDA BUILDING CODE RESIDENTIAL [FBCRI, THE 20 17 NATIONAL ELECTRICAL CODE (NFPA 70), AND THE FLORIDA ADMINISTRATIVE CODE. 2. SMOKE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH [FBCRI SECTION 3 14 AND FBC SECTION 907.2.11. 3. HARD -WIRED COMBINATION CARBON MONOXIDE AND SMOKE ALARMS SHALL BE INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSES IN ACCORDANCE WITH [FBCR3 15. l .] 4. ALL NON-GF( OUTLETS TO BE ON ARC FAULT INTERRUPTERS. 5. ALL l 5A AND 20A, 125V RECEPTACLES THAT SERVE KITCHEN, BATHROOMS, LAUNDRY ROOM, AND GARAGE AND COUNTERTOP SURFACES AND RECEPTACLES INSTALLED WITHIN 6 FT OF THE OUTSIDE EDGE OF A WET BAR SINK AS WELL AS OUTDOOR LOCATIONS SHALL BE GFCI-PROTECTED IN ACCORDANCE WITH [NFPA 70 210.B(A)(l -10)], P OL 6. A WEATHERPROOF DUPLEX RECEPTACLE WITH GFCI PROTECTION SHALL BE INSTALLED ADJACENT TO EACH AIR BEACH ENTRY CONDITIONING UNIT. DISCONNECTING MEANS SHALL BE LOCATED WITHIN SIGHT FROM AND READILY ACCESSIBLE FROM THE AIR-CONDITIONING EQUIPMENT. REFER TO PLAN FOR LOCATION OF AIR CONDITIONER UNIT. CONTRACTOR lS TO VERIFY THAT A/C AIR HANDLERS COME SUPPLIED WITH FACTORY INSTALLED DISCONNECT [NFPA 70, 440,141 7. ALL SPECIAL PURPOSE OUTLETS SHALL BE PROVIDED AS PER EQUIPMENT MANUFACTURERS' SPECIFICATIONS. -------------- ----------------------------__ 6. RECEPTACLES FOR PERMANEIVTLYINSTALLED POOL MOTORS, OR OTHER LOADS DIRECTLY RELATED TO THE CIRCULATION SYSTEM MUST BE LOCATED AT LEAST 6 FT FROM THE INSIDE WALLS OF THE POOL, BE GFCI __ _----- _ PROTECTED, AND BE OF THE GROUNDING TYPE. [FBCR 660.220)(2). ALL I5A AND 20A, 125V RECEPTACLES -- LOCATED WITHIN 20 FT FROM THE INSIDE WALLS OF THE POOL MUST BE GFCI PROTECTED. 660.220)(4). ` --_ 9. SECURITY, CATV AND DATA STRUCTURED WIRING SYSTEM IS TO BE DESIGNED BYAN INDEPENDENT CONSULTANT WHO IS TO COORDINATE AND VERIFY ALL LOCATIONS OF ALL SUCH EQUIPMENT SHOWN ON THIS ___--- SOFFIT LIGHTINGDLEEN0) I PLAN WITH THE CONTRACTOR PRIOR TO INSTALLATION. ---- _ h'l BL I=ND / '-- l 0. ALL SWITCH, RECEPTACLE, JACK AND WALLCOVER PLATE COLOR SHALL BE CONSISTENT THROUGHOUT. l I. PRIOR TO INSTALLATION, CONTRACTOR IS TO VERIFY (VIA WALK-THROUGH WITH OWNER.) we Q j Q wR / 2. POOL EQUIPMENT AND LIGHTING CONTROL IS NOT INCLUDED IN THIS PLAN. CONTRACTOR SHALL COORDINATE / ---------------------- z------- �''�---------------------- CAMERAO ------------ - \ #2 I__ I Digitally signed by _1_j E ` Kathleen S Yancy ------------------------\ --- � III � DN: cn=Kathleen S Yancy, I TITTTIT I . -. T�TTIT�trj�j \ _ o, ou, EQUAL EQUAL HB�h \ I \ email=ksy-architect@bells "� \ I / outh.net, c=US EQUAL \ i iELL, III ll r li\I li L li ll Date: 2021.02.22 07:40:01 '-05'00 1, O 1 I'I O TT 1 ------ I 1� iJmfi&u� ------------ ;1 011 L r =__- ________;_— T� UTOFF - ;/ ec(NCA ERA II wec W4 44-4 \\ \\ 1 j I PENDANT BY D \` 4 / OWNER I I qg DATA-'� ---- 1 1 - - I I / MASER AlI CLG , ��� `\ III 1 I L BEDR(POM I \\ -- HBI -- 1 ---� --\-- \\ 1 II FLAT ILL, I 11 WALL n AC #/ Lp DEN ® \\ \ T TT I / II '42" v FLAT CLG vv I { - e `\ L MOUNT V r V - +42" I / 1 DATA -- I ---------\— —� CAANA I /' /' / I \ $D / _ , � / I \III I _/ _ __ _ - I FLIT CLG ,_-- ----_, R I ,,,__-_ � / -- �\ � 2 i CAMERA� T �,'_ i +32„I \ // �i' I\ I L-------L----- SHOWER 1 llli% D D `\ `\ I �`\ \ / I II II -- c\\ % `vII -\ FC CP1 3 1 --- i +so° + o„ 4z Q +421' USB l \\ i; +�2"I ---_____ \I _ I ------- -------- T NTERIOR CA�3INeT1 II II ER CA E TRIP HTING �___� �---- \ -- — ----- -------LGHIING�IYP�— RO LOAD FRONT LOAD \ � \ »JJCC � I \I I GENERATOR \ I I DR R WASHER I +42" \ / 24" UNDER- --- - I I II - TRANSFER LAUNDRY`\ +42j' usB I ` / � — I II III O / I MOUNT SINK I \ / _ _ _ _ _ _ _ II / SWITCHES FLAT CLG 1 L===� J \ - - - --r / -- / OH CABINETS / DW+4,.'USB �j IN NG A E 1 I 1 GREA ROOM •- F=== GD _5wTCHBffLowCATNEORAL IIi iyt 1\ m I CATHELIRAL CLG / OH -CAB CUBBY / / r = , ------ — - --- +4USB —O G O`�AB/NETSHANG/NG RBROOM UN 42" 4I, USMOUNYS/NK- +4-- I — 11I r _ ,�,__ 3 , KI7�CHEN ! I I I ALL MOUNT TV + I42' ow ELEC PANELS __ y''.' / \ 1-42"4 — I I I \ FAT CLG I I 4 DROP \ i II O I\\ ------- TANK[yES5 WATER \ UNDER CABINET / HEATERS LOCATED \\ +42" \ STRIP LIGHTING (7YP) L o �C / \ I / I, \ ------ I I` o I IN ATTIC TO A � \ / +321 I WALL MOUNT ---, ' �IIh� _-'�� -,\ / I I O-- /---------------- III ; - III/ 2' i OHONAL WALL MOUNT i 1 / III III \\ I LOCATION FOR GARAGE i i 1\ III III \\ /Q +42" i I - \ l DO R OPENER (VERIFY 1/ \ I I -----i 1------- I'- \ I I------,�- ��� i �'�/ BEVERAGE �'_---- �---- ---------- � II II / WlT OWNER PRIOR TO �� _�� ---- __ I �I, I �'_�AR 1-------- '--------------- II li l / I \ L J--____ OH CABINETS l ELE TRICAL ROUGH IN) / I 1�•` +42° I r------r 1 C I II \ I I I I \ _ UNDER APA#T GHT G FLAT CLG D D \ U � CAMERA #7 J - 1 30" RH 30" LH I KITCHENAIDE KITCHENAIDE i WINE ICE 1 + 2" Mll R R I 1 ' SLQPE SLAB t +4 cw +42° cw , // I I W GFa - ' �-------------------- I CL // 1 /1\ 1_ DATACL 2„ 1 ` +4 DATA ON CABINETS +42" /1`" F-- ��y'Of�WDE / !-- G O I I AHU UNDER CA(NET STRIP \ + TA i t &OOOp CLOSET I CEILING MOUNT i I I I LIGHTANG I D TA coU yl777 I I / F16 �OLG (SEE OPTIONAL I I O I (THROUGHOUT ANTRY) + ----' ` I+42" 1 f4� Z j ,' SHELVES I I I 1 I / I PANrI��' I\ UNDER CABINET \ \ I z I, I / %�, LOCATION ABOVE) I I \ +4�„ I FLAT CLG` 1 42" STRIP LIGHTING \ i O I I I \ I I __----' I 42' 1 I I OVER I I GARAGE \\ I I t I L o \ I HANG I / FLAT CLG �� 1 I I / �I --''1 I ;> > \ j � AHU SHELVES y I / \ COUNTER TOP / fl42„ I I I / ___---- L--------J II / =Q I ----LINEN------ / DATA / / I Z #2 + 2° CLOSET \ +42° / ' CLOSET 42" +2" / \ 0rl DooR i / vvv i Rc vv "DROP + �\ ___------_� I vvvv 0 ' // ' --------------------- O +42" Q I ti ------ --- ww 0 _ z o \\ II GARAGE o ° ' �\ OFFICE /j LT _ ----------------- SIC\__ we UTILITY SINK STORAGE I / \\ REVERSE rile CL // ��'' / vv GFCI ALLOW FOR SLOPE j \II I +42° I DATA x / 1 \ \ I FM\ �f% - 1 \ \ 1 1 1 1 11 I 1 1 1 \ HDHD \`♦ t C WRC \\\ �HD SCO I ^^�`\ j 11 �-1 v wRc 1v 6'-314 ° \\ WACL =- ,-:' i I I CAMERA -`.---- #/ L \\ %/ \� MOUNT I _ / 1 DATA I i i " BEDROOM I I / FLAT CLG `\ / I _ \\\ IC RCY II 2, 6„ \\ OVER 1 /---------------------\ \\ HANG 1 FLR TO CLG CAB BURIED LP TANK WINDOW 1\ I \\ SEAT "f"--- + / --- \\----------------------'/ \\\�\ _..._----------------------------------L-------------- _..._. -------------I - / I HB WR TO LANDSCAPE \\ LIGHTING L' 3 PO" I 0 MOLrINT II ITV CL::�D0� I I D D I+ EXERC1 E 1 ROOM 1 FLAT CLG ,\ R O / / / I I I J T---- I ------------- - �� CLOSET i� ~UI MASTER BATH ;-_�_�_\ � FLAT CLG 11 JET i PENDANT BY OWNER I\ I ''GLASS SHOWER WAJL cEip\ G w COVER 60" HIGH TILED W LL Q' WA, f 7777 RLTK - ' MC EAP, \ N SHC GEC/ MIRRORGFci LkO +42" +42" _ j Z FLOOR DRAIN VIE / / / I 1 I I I I 1 1 1 BEDROOM \\ 4 FLAT CLG sho i BEDROOM 3 FLAT CLG / / 1 1 I 1 I I I I I I I 1 I I 1 1 / 1 1 NICHE CESSED OwE \ VP ♦`I wRC AC #2 SHUTOFF fc I zj+30 - V-2„ -OVER I= HANG / 3 F GFCI+42" BATHROOM 2 \I FLAT CLG 1 \y I I I I \ 1 MIRROR -7 1 RLTK \ 5HOwE y' RLTK M/R,�OR \\� RECESSED LIGHTING @ VANITY TOE KICK (TYP) I r J„ D P��' +42" MC ,\ MC / wRC NICH F61I < C \ O f"— —CAMERA / PHB F 0 O FC OROo0��0 00000 � o S. yq y mo G> °1 1 ' o� AR94272 ° °: L 0��00o o� 0 tlRED°°P�G000 LQ L z v� LQ v J 4� L " J C) �IYI I U O Q N O Q O O O z O � O v O O O N 0 a O O II � O B, O m W � 0 0 N.T.S. ELECTRICAL PLAN 11411 _ 1 1-011 SHT. NO, A-6 OF / /