HomeMy WebLinkAboutIKO Shingle Product Approvala
BCIS Home Log In User Registration Hot Topics
Submit Surcharge Stats & Facts
Publications
Contact Us BCIS Site Map
Links Search
Product Approval
USER: Public User
ui
Product Approval Menu > Application Detail
FL #
FL30310-R1
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
IKO Industries Ltd
40 Hansen Road South
Brampton, NON -US L6W 3H4
(905)457-2880 Ext4581
william.liu@iko.com
William Liu
william.liu@iko.com
William Liu
40
Hansen Road South
Brampton, FL L6W 3H4
j416)525-3740
william.liu@iko.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence F 0 1 _U_C01_IKO19002.2 2020 FBC Eva] Shingles final.pd
Referenced Standard and Year (of Standard) Standard Year
ASTM D 3018 1990
ASTM D 3161 2016
ASTM D 3462 2010
ASTM E 108 2016
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...%2bffZfjpUCSn6k71pZ96MbxnNUZe3Q76B4ygcSbcEBw%3d%3d 2/18121, 3:47 PM
Page 1 of 2
TAS 100 1995
TAS 107 2020
Equivalence of Product Standards
Certified By
Sections from the Code
u
Product Approval Method Method 1 Option D
Date Submitted 10/16/2019
Date Validated 10/23/2020
Date Pending FBC Approval 10/28/2020
Date Approved 12/16/2020
Summary_of Products
FL # Model, Number or Name ? Description
30310.1 IKO Shingles ASTM D 3161, Class F asphalt shingles, hip and ridge shingles,
starter strip & shingle strip
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL3031G_R1_II_IK019002.2 2020 FBC Eval Shingles final.Ddf
Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest PE-74021
Impact Resistant: N/A ` Created by Independent Third Party: Yes
Design Pressure: N/A j Evaluation Reports
Other: See evaluation report for limits of use. FL30310_fi1_AE_IKO19002.2 2020 FBC Eval Shin
final pgff
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850,487,1395, *Pursuant to Section
455.275(t), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S, must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
Credit Carts
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV...%2bffZfjpUCSn6k71pZ96MbxnNUZe3Q76B4ygcSbcE8w%3d%3d 2/18/21, 3:47 PM
Page 2 of 2
i_ ° TECHNICAL., SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Plants:
Quality Assurance:
SCOPE
IKO INDUSTRIES, LTD
40 Hansen Rd S
Brampton, ON L6W 3H4
Canada
(905) 457-2880
www. iko.corn
Calgary, Alberta
Hawkesbury, Ontario
Hillsboro, TX
Kankakee, IL
Sumas, WA
Sylacauga, AL
Toronto, Ontario
Wilmington, DE
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 7.. EDITION (2020)
PRI Construction Materials Technologies (QUA9110)
Issued October 22, 2020
Category: Roofing
Subcategory: Asphalt Shingles
Code Edition: Florida Building Code, 7"' Edition (2020) including High -Velocity Hurricane Zones (HVHZ)
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.5.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
FM Approvals (TST1867)
3036971
FM 4475
2010
FM Approvals (TST1867)
3040947
FM 4475
2010
ASTM E 108
2016
FM Approvals (TST1867)
3041689
FM 4475
2010
FM Approvals (TST1867)
3044376
FM 4475
2010
FM Approvals (TST1867)
3045254
FM 4475
2010
FM Approvals (TST1867)
3046191
FM 4475
2010
PRI Construction Materials Technologies (TST5878)
IKO-050-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-051-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-053-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-067-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-071-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-072-02-02
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-076-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-077-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-088-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-095-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-096-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-099-02-01
TAS 100
.1995
PRI Construction Materials Technologies (TST5878)
IKO-100-02-01
TAS 107
2020
PRI Construction Materials Technologies (TST5878)
IKO-114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-115-02-01
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-120-02-01
ASTM D 3462
2010A
IK019002.2 FL30310-R2 Page 1 of 15
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
REEK
TECHNICAL SERVICES, LLC
IKO INDUSTRIES, LTD
Asphalt Shingles
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
IKO-121-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-123-02-01
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-125-02-01
TAS 107
2020
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-126-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-127-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
1KO-128-02-01
TAS 107
2020
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-129-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-130-02-01
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-131-02-01
TAS 107
2020
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-140-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-148-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-153-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-171-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-171-02-02
TAS 107
2020
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-171-02-03
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-198-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-198-02-02
TAS 100
2020
PRI Construction Materials Technologies (TST5878)
IKO-198-02-03
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-199-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-199-02-02
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-199-02-03
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-201-02-01
ASTM D 3462
2010A
ASTM E 108
2016
ASTM D 3018
1990(R94)E1
PRI Construction Materials Technologies (TST5878)
IKO-201-02-02
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-201-02-07
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-202-02-01
ASTM D 3462
2010A
ASTM E 108
2011
ASTM D 3018
1990(R94)E1
PRI Construction Materials Technologies (TST5878)
IKO-202-02-02
TAS 107
2020
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-202-02-07
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-203-02-01
ASTM D 3462
2010A
ASTM E 108
2011
ASTM D 3018
1990(R94)E1
PRI Construction Materials Technologies (TST5878)
IKO-203-02-02
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-203-02-07
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-205-02-01
ASTM D 3462
2010A
ASTM E 108
2016
ASTM D 3018
1990(R94)E1
PRI Construction Materials Technologies (TST5878)
IKO-205-02-02
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-205-02-07
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-206-02-01
ASTM D 3462
2010A
ASTM E 108
2016
ASTM D 3018
1990(R94)E1
PRI Construction Materials Technologies (TST5878)
IKO-206-02-02
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
IKO-206-02-07
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
IKO-208-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-217-02-01
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
IKO-218-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
476C0017.1
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
476C0017.2
ASTM D 3161
2016
PRI Construction Materials Technologies (TST5878)
476C0017.3
ASTM E 108
2016
PRI Construction Materials Technologies (TST5878)
476C0020.1
ASTM D 3462
2010A
PRI Construction Materials Technologies (TST5878)
476C0020.2
ASTM D 3161
2016
IKO19002.2 FL30310-R2 Page 2 of 15
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LI_C
Entity
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
Resort No.
476C0020.3
476C0033.1
476C0033.2
476C0033.3
476T0002
476T0003
476T0004
476T0012
476T0013
476T0021
476T0022
476T0023
476T0034
476T0039
476T0040
476T0041
476T0042
476T0043
476T0044
PRI Construction Materials Technologies (TST5878)
476T0045
PRI Construction Materials Technologies (TST5878)
476T0046
PRI Construction Materials Technologies (TST5878)
476T0057
PRI Construction Materials Technologies (TST5878)
476T0058
PRI Construction Materials Technologies (TST5878)
476T0059
PRI Construction Materials Technologies (TST5878)
476T0061
PRODUCT DESCRIPTION
Standard
ASTM E 108
ASTM D 3462
ASTM D 3161
ASTM E 108
ASTM D 3462
TAS 100
ASTM D 3161
ASTM D 3462
ASTM D 3018
ASTM D 3161
TAS 107
ASTM D 3462
ASTM D 3018
ASTM D 3161
TAS 107
ASTM E 108
ASTM D 3462
ASTM D 3462
ASTM D 3018
ASTM D 3161
TAS 100
ASTM D 3462
ASTM D 3018
TAS 100
ASTM D 3462
ASTM D 3018
ASTM D 3161
TAS 100
ASTM D 3462
ASTM E 108
ASTM D 3161
ASTM D 7158
IKO INDUSTRIES, LTD
Asphalt Shingles
Year
2016
2010A
2016
2016
2010A
1995
2016
2010A
1990(R94)E1
2016
2020
2010A
1990(R94)E1
2016
2020
2016
2010A
2010A
1990(R94)Ei
2016
1995
2010A
1990(R94)E1
1995
2010A
1990(R94)E1
2016
1995
2010A
2016
2016
2019ael
RoofshakeTm HW
13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Sumas)
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Shingles shall be used in the non-HVHZ only.
ArmourshakeTM
18-1/2" x 37-3/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Sumas)
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Royal EstateTm
13-1/4" x 40", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Toronto)
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Crowne Slate
13-1/4" x 39-1/2", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Toronto)
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Shingles shall be used in the non-HVHZ only.
DynastyTm
13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary, Hawkesbury,
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Hillsboro, Kankakee &
Shingles manufactured in Calgary and Sumas shall be used in the non-HVHZ only.
Sumas)
NordicTm
13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Hillsboro & Kankakee)
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
IKO19002.2 FL30310-R2 Page 3 of 15
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
IKO INDUSTRIES, LTD
Asphalt Shingles
iCAL SERVICES. LLC
CambridgeTA° �\
13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary, Hawkesbury,
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Hillsboro, Kankakee, �'
Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only.
Sumas, Sylacauga,
t\-TO\ ronto & Wilmington)
i
CRC Btttrrrore®-__� �'
13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary, Hawkesbury,
architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Sumas & Toronto)
Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only.
CRC Regency® 13-3/4" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated
(Calgary & Hawkesbury) architectural asphalt shingle surfaced with granules complying with ASTM D 3462.
Shingles manufactured in Calgary shall be used in the non-HVHZ only.
CRC Superglass® 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with
(Calgary, Hawkesbury & fiberglass mat coated on both sides with asphalt and surfaced with granules complying
Toronto) with ASTM D 3462. Shingles manufactured in Calgary and Toronto shall be used in the
non-HVHZ only.
Marathon""" Plus AR 13-1/4" x 39-3/8", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with
(Calgary, Hawkesbury, fiberglass mat coated on both sides with asphalt and surfaced with granules complying
Hillsboro, Kankakee, with ASTM D 3462_ Shingles manufactured in Calgary, Sumas and Toronto shall be
Sumas, Sylacauga & used in the non-HVHZ only.
Toronto)
Hip & Ridge TM 12 13-1/4" x 36", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip and
(Kankakee & Sylacauga) ridge shingle surfaced with granules and perforated every 12-inches complying with
ASTM D 3462.
Hip & Ridge PIusTM 13-114: x 39-3/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip
(Calgary) and ridge shingle surfaced with granules and perforated every 13-inches complying with
ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Hip and RidgeTM 13-1/4" x 39-3/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip
(Sumas) and ridge shingle surfaced with granules and perforated every 10-inches complying with
ASTM D 3462. Shingles shall be used in the non-HVHZ only.
Armour StarterTm 13-1/4" x 39-3/8", ASTM D 3161, Class F fiberglass reinforced asphalt strip embedded
(Sumas) with granules complying with ASTM D 3462. For use with Armourshake'rM shingles.
Leading Edge PJUSTM 7-7/8" x 40-7/8", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt
(Hawkesbury) shingle strip surfaced with granules complying with ASTM D 3462.
IKO19002.2 FL30310-R2 Page 4 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEKi
TECHNICAL SERVICES, LLC
Cambridge TM
(Calgary (Non-HVHZ),
Hawkesbury, Hillsboro,
Kankakee, Sumas,
Sylacauga, Toronto (Non-
HVHZ) & Wilmington)
and
CRC BiltmoreTM
(Calgary (Non-HVHZ),
Hawkesbury, Kankakee,
Sumas (Non-HVHZ) &
Toronto (Non-HVHZ))
IKO INDUSTRIES, LTD
Asphalt Shingles
Basic Wind Speed Vwt) Max. 194 MRh
Basic Wind Speed Vag : Max. 150 mph
Deck (HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck (Non-HVHZ): Solidly sheathed in accordance with FBC reauirements.
Min. slope: 1 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
j shingles at slopes greater than 21:12. .
Installation (HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
j Pattem" or "6 Nail Pattern" detailed below.
Nail Line Common Bond
k
Standard Application
Requires 4 Nails/Fasteners
Nail
Line
Figure 9. CambridgeT"" and CRC BiltmoreTm
4 Nail Pattern (non-HVHZ only)
Steep Slope/High Wind Applications
Requires 6 Nails/Fasteners
Nail
Line
Nail Line
Figure 10. CambridgeTm and CRC BiltmoreTm
6 Nail Pattern
A�
\ 5-7/8
Common Bond
5-7/8
IKO19002.2 FL30310-R2 Page 10 of 15
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
IKO INDUSTRIES, LTD
Asphalt Shingles
Hip & RidgeTM 12 Basic Wind Speed (V.1t): j Max. 194 mph
(Kankakee & Sylacauga) Basic Wind Speed (Vasa): Max. 150 mph __
Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed
and ! I min. 19/32 in. plywood or wood plank for new construction;
Min. 15/32 in. plywood existing construction.
Hip & Ridge PlusTm Deck Non-HVHZ : Solidly sheathed in accordance with FBC requirements.
(Calgary) Underla ment: In accordance with FBC requirements.
(non-HVHZ Only) l Min. slo e: 2:12 and in accordance with FBC requirements. _
Installation: Installed with 5-5/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
i prevailing wind.
Perforation Marks
Start Direction of prevailing wind
nere�-
t
s . Nails
1" Taper Cut
Figure 13. Hip & RidgeTm 12 and
Hip & Ridge PIUSTM (non-HVHZ onl
IK019002.2 FL30310-R2 Page 12 of 15
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
IKO INDUSTRIES, LTD
Asphalt Shingles
Hip and Ridge TM I Basic Wind SeeMax. 194 mph
f..�.�..—.—.. _._.._....... _._....__.._.__.._..._..___----_---__—
(Sumas) ; Basic Wind Seed(Vasd} Max. 15_0
Deck Non-HVHZ : Solidi sheathed in accordance with FBC requirements.
Underla ment: In accordance with FBC requirements.
Min slope: 1 2:12 and in accordance with FBC requirements.
Installation: 1 Installed with 5-5/8 inch exposure, in accordance with the
1 FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
jprevailinq wind.
Nails
Start Direction of prevailing wind
here-
_ aj3�
Perforation Marks
re 14_Hip and
i
-1/4" 1
1
1" Optional Taper Cut
7Anon-HVHZ on
1" Taper Cut
IK019002.2 FL30310-112 Page 13 of 15
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
IKO INDUSTRIES, LTD
_4 CREEKAsphalt Shingles
TECHNICAL SERVICES. L.LC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, R.E. have demonstrated compliance with the Florida Building
Code, 71h Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
tee` GAP' • Ri �,,
No 74021
• • � — aPa•Y NBroE W ZxNry R. PMI
�X=
-04'00'
-:0'.. STATE OF : 4/
,�•••,� P .�� uZachary R. Priest, P.E.
'�,��` '• O R 1 �.•' �� ��` Florida Registration No. 74021
�•,SS��NA� ` Organization No. ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
IK019002.2 FL30310-R2 Page 15 of 15
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.