HomeMy WebLinkAboutPA FL32344-R1BuIsiness &Professional Regulation
R
r ISCIs Hame ! Log In I User Registration iiotTopfcs Submit Sureharpe srar� s ❑a—
100% r
Product Approval
USER: Public User
FMIUII A proval Menu > ro r ti r rc ,API
-11cation Ust > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Emall
Authorized Signature
Technical Representative
Add ress/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Late
Validated By
FL32344-RI
Revision
2020
Pending FBC Approval
�r.
Pu6liratior's contact Us BCiS Site Map i Links , 'Search
Owens Corning Roofing and Asphaft, LLC
One Owens Corning Parkway
Toledo, OH 43645
(740)321-6345
Greg. Keeler@owenscorning,com
Keefer Greg
Greg. Keeler�7a owenscorning.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nierninen
PE-59166
PRI Construction Materials Technologies, LLC
05/05/2021
John W. Kne2evfch, PE
1. Validation Checklist - Hardcopy Received
Certificate of Independence F32344 RI CQi_7t] 0� iV1EMiNEN.11cif
Referenced Standard and Year (of Standard) Standard
Year
ASTM ❑1970 2015
Equivalence of Product Standards
Certified By
https://www.florfdabuiIding.org/pt/pr_app_dtJ-aspx?param=WGEVXQWtDqu06fur%2fZNOOIYVp06mrKPjUPVCvnB6jKEZZSo8%2fRaQFvv%Sd%3d Page 1 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Produ
FL # Model, Number or Name
32344.1 RhinoRoof GRN _�
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
other: Refer to ER Section 5 for Limits of Use.
Method 1 Option D
12/11/2020
12/15/2-020
12/17/2020
Description
Granule-surfaoed, self -adhering roof underlayment
Installation Instructions
l L32344. 1 F 2D20 _1D F„NAB RNINCRQ
GRN FL 2344-R1. f
Verified By: Robert Nfeminen PE-59165
Created by Independent Third Party: Yes
Evaluation Reports
P 3,234--RI—?E_ZQZD 17RF N L ER_Rti�Q
RN F 2344-R1 Ldf
Created by Independent Third Party: Yes
;g [6e:xk
n act Us :: 2501 51air Stone Road, T I[Ahassae ct 323P9 Phon-4 7- 4
The State of Florida is an AAJEEO employer. Cooydyht 2�n7-�Qt Sty*� F Rarida.:: P j t m
�i[ :: A c -Ili eta me :: gefund Statement
under Florida law, email addresses are public records. if you do not want your a -mail address released In response to a pub[I,-remrds requesC, do not send electronic
mail to this entity, Instead, contact the pace by phone or by traditional mall. If you have any questions, please Contact 850-487.1395. *Pursuant to Section
455.275(1}, Florida Statutes, effective October 1, 2012, licensees 11rensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for Offldal Communication with the licensee- However email addresses are public record. if you do not wish to supply a
personal address, please provide the Department with an email address which can ]>e made available to the public. To determine if you are a licensee under CJiapter
455, F.S., please click re .
Prod Ct Approval Accepts:
tzn MW
J 'Gi - im
stetlritr°:�'f3'rltic��
http5:11Wvuw.florid abui€ding,arglpr/pr-app-dt€.aspx?param =wGEVXQwtaqu08fur% 2f2NO0lyVp06mrKFj V PV6vn66jKEzzS08% 2fRa4Fw%3d%3d
Page 2 of 2
NEM® I etc.
Certificate afAi.thorization ii3245s
353 Christian Street, Unit #13
0 Oxford, CT 06478
ENGINEER EVALUATE
TEST(2Q3) 252-9245
CONfSULT
Owens Corning Roofing and Asphalt, LLC
one Owens Corning Parkway Evaluation Report 3m-DC-20-FBCER.01-RI
Toledo, OH 43659 FL32344-RI
(740) 321-6345 Date of Issuance: 06/04/2020
5C4PE: Revision 1: 12/10/2020
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 71h Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: RhinoRoof® GRN
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FSC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named Product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the produc(s} change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s), NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
Robert J.M. Nieminen, P.E.
---• -= `~- w.
Florida Registration No. 59I66, Florida
The facsimile seai appearing wa5authorizedhyRahert
DCA ANE1983
Nieminen, P.E. on iz/lo/zwo. This does not serve a
�• n .,u
CERTIFICATION OF INDEPENDENCE:- an eleatronicaily signed tlacurnen:. s
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any cornpany manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E_ does not have nor will acquire, a financiaf interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product,
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P,E. are, in any way, the Designer of Record for any
projecton which this Evaluatlon Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMo ETC, LLC
ROOFING COMPONENT EVALUATION: (NNEMOletc.
Product Category: Roofing
Sub -Category: U nderlayment
Compliance Statement: RhinoRoofs GRN, as produced by Owens Corning Roofing and Asphalt, LLC, has
demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/ Conditions of Use setforth herein.
Section
Property
Standard
Year
1507.1.1, 1507.2.4,1507.2.9.2
Material standard
A5TM D1970
2015
/ R905.1.1, R905.2.8.2
Enti
Examination
Reference
Date
PRI(T5T5878)
A5TM D1970
OCF-293-02-03
12/20/2017
PRI(TST5878)
ASTM D1970
OCF-253-02-02
12/21/2017
Owens Corning
Quality Control
Declaration
07/15/2020
PRI (QUA9110)
PRI (QUA911D)
Quality Control
Service Confirmation
05/05/2020
Quality Control
Florida BCis
Current
Product Material Standard Plant(s) Description
RhinoRoof GRN A5TM D1970 (Table I)' Brentwood, NN Granule -surfaced, self -
Houston, Tx adhering, roof underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miarni-
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 RhinoRoof GRN may he used with any prepared roof cover where the product is specifically referenced within FBC
approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based
on this evaluation combined with supporting data forthe prepared roof covering.
2 Agreement between purchaser and seller, as set forth in Section 4.3, Note I of ASTM,D1970-15, shouldhe established as to slip resistance
of RhinoRoof GRN,
NEMO ETC, LLC
Certificate ofAuthorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Evaluation Report 3rn-OC-20413CER.01-111
FL32344-R1
Owens Corning RhinoRoof& GRN Revision 1: 12/10/202o
0- 7 of:a
5_6 Allowable Roof Covers: (NNEMOJetc.
TABLE 1: ROOF COVER OPTIONS
F5CSection_ 1507.2 2507.3 15074 & 1507.5 IS077
I507.8 & 1507.9
Asphalt Clay and Concrete TILE Metal Wood
Underlayment Mechanical Adhesive- Slateor5late-
Shingles Pan Shingles T e5hin les R
Attach Set g Shingles Shakes
RhinoRcof® GRIN Yes N❑ No Yes
1 No No Yes
{joint strips,1507.1.13
R9p5 1.Z.3]
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates (designed to meet wind loads for project)
Type Primer M
aterial(s)
RhinoRoof® GRN self -adhering Deck / sheathing None
5.8 Attachment Limitations:
For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R9C5.1.1.
5.9 Exposure Limitations.
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days)
RhinoRcof® GRIN Mechanically attached
30
6.1 RhinoRoof GRN shaff be installed in accordance with Owens Corning Roofing and Asphalt, LLC published
installation requirements subject to the Urnitatrons set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any ioose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (rf applicable).
6.3 Rhino Roof® GRN:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM U1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
As required by the Building official or Authority Having Jurisdiction to properly evaluate the installation of this
prod u ct.
Contact the named CIA entity for manufacturing facilities covered by F.A.C_ Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
PRI Construction Materials Technologies, LLC— QUA9110; (813) 521-5777; bwils�cmt mom
- END OF EVALUATION REPORT -
NEMO ETC, LLC
L32344
Certificate Of Authorirution#32455 7rH EDMON (2020) FBC NON-tIVHZ EVALUATION Evaluation Report 3m-OC-20-FF-RI
L32344-R1
Owens Corning RhinoRoof® GRN Revision 1: 12/10/2020
0—'1 of :2