HomeMy WebLinkAboutPA FL10758-R8, F
, usiness
s Professional Regulation
8CiS Home i � Log in user Registration Hat Topics ; Submit Surcharge stars & Facts Publications contact Vs 6CIS Site Map Links Search
b
��
Product Approval pr
' USER! public User
Product Annroval Menu > Pmdurt or Amlication Search > Aoolication List > Annlication Detail
FL # FL10758-RS
..... .... ....... ....... ......i Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
9reg. keel er@owenscernIn9.corn
Greg Keeler
g reg . kee le r@awe ns tarn i ng . tom
Greg Keeler
2790 Columbus Road
Granville, OH 4302-3
(740) 321-634S
greg.keeter@owenscorning.com
Roofing
Roofing Accessories that are an Integral Part of the Roofing System
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Prafessianal Engineer
Evaluation Report - Hardcopy Received
Zachary R. Priest
PE-74021
PRI Construction Materials Technologies, LLC
12/31/2024
Steven M. Urich, PE
,, Validation Checklist - Hardcopy Received
FL10758 R8 I_OCR14003.4 2020 FRC EVAI Vents find[^odf
https!//www.floridabuilding.ors/pr/pr_app_dti.aspx?pararn=wGEVXQwt0gvidAvite0Y012bc3zFirydg9fPiig LAC VmFHfXgo03A5JQ%3d%3d Page 1 of 3
Certified By
Sections frorn the Code
17D8.2
Product Approval Method Method 2 Option B
Date Submitted 09/10/2020
Date Validated 12/16/2020
Date Pending FBC Approval 09/18/2020
Date Approved 12/17/2020
Summary of Products
FL*
Model, Number or Flame
Description
10758.1
VentSure 4-Foot Strip Heat and
Copolymer plastic low profile attic ridge vents for installation
Moisture Ridge Vents
in shingle roof systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1075$ R8 It OCR14003.4 ZD20 FBC Eva] Vents final .odf
Approved for use outside HVHZ: Yes
Verified By: Zachary R. Priest 74021
Impact Resistant: N/A
Created by independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to evaluation report
FL1 758 R8 AE R140 3.4 202n FB Eval Vents final �df
Created by Independent Third Party: Yes
10758.2
VentSure Low Profile Slant Back
Galvanized metal roof vent
Roof Vent With Exterior Louver
I
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
L1E 075a_R8 II OCRI4003.4 2020 FBC. Eyal Vents final pdf
Verified By: Zachary R. Priest 74021
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other! Refer to evaluation report.
FL10758 R8 AE OCR14001.4FK-Eval Vents final .pdf
Created by I ndepende nt Th i rd Party: Yes
1D758.3 VentSnre Rigid Roll Ridge Vent
Ridge Ventilation System
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
L7 Q7—U_g8 II OCRI4003.4 2020 PSC LWi p,. final ,pdf
Verified By: Zachary R. Priest 74021
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to evaluation report.
FLI0758 R8 AE OCR14003,4 2o20 FBC Eval Vents final IPdf
Created by Independent Third Party: Yes
Sack fifaxt
Contact Us ::.2601 Blair stone Road_ Tallahassee FL 32399 phone: l350-4&7-187.4
The State of Florida i5 an AA/EEO errlployer right 207-2013 State of Florida.:: Pri vacv Statement :: psi billty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic
mail to this entity instead, contact the office by Phone or by traditional mail Ir you have any questions, please contact 850.487.1395.-Pursuantto section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for offlclal oommunlcation with the licensee. However email addresses are public record. if you d❑ not wish to supply a
personal address, please provlde the Department with an emall address which can be made available to the publlcTo determine if you are a licensee under Chapter
455, F.S_, please dick here .
product A pprova l Accepts:
M No ®-
https:llwww.floridabuilding.org/pr/pr_app_dfl.aspx?pa ram=wGEVXQwtDgv1dAvlteOY0%2bC3zFtrydggfphgLACiVmFHfXgoD3ASJQ%3d%3d Page 2 of 3
Credit Card
Safe
htfps:J/wwwfloridabuilding.org/pr/pr app_dtl.aspx7param=nvGEVXQwtDgvIclAvlteCYO%2bC3zFtrydg9fPhgLACiVMFHfXgUD3ASJQ%3d%3d Page 3 of 3
CREEK
Certificate of Authorization No. 29524
1752Q Edinburgh Dr
°tI• Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7"i EDITION (2020)
Manufacturer:
OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7435
www. owe n s corn i n p, co m
Quality Assurance:
PRI Construction Materials Technologies (QUA9110)
SCOPE
Category:
Roofing
Subcategory:
Roofing Accessories that are an Integral Part of the Roofing System
Code Sections:
1708.2
Properties:
Roof Ventilation
REFERENCES
EaLty
Report No.
Standard
Year
Architecturai Testing, Inc (TST1558)
01-38360.04
TAS 100(A)
1995
Architectural Testing, Inc (TST1558)
01-38860.05
TAS 100(A)
1995
Architectural Testing, Inc (TST1558)
C1774.01-109-18
TAS I OO(A)
1995
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2016
PRI Construction Materials Technologies (TST5878)
AVIG-005-02-01
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2015
PRI Construction Materials Technologies (TST5878)
AVIG-006-02-01
ASTM G 155
2013
PRI Construction Materials Technologies (TST5878)
OCF-111-02-01
ASTM D 635
2014
ASTM D 1929
2016
ASTM D 2843
2016
PRI Construction Materials Technologies (TST5878)
OCF-112-02-01
ASTM G 155
2013
PRI Construction Materials Technologies (TST5878)
OCF-116-02-01
TAS 10D(A)
1995
PRI Construction Materials Technologies {TST5878]
QCF-223-02-01
TAS 1 DD(A)
1995
PRI Construction Materials Technologies (TST5878)
01-1I-007-02-01
TAS 100(A)
1995
QCR14003.4 _ FE_10758-R8 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
cneriFrral[ar arlriraccerl herein
3": CREEK QWEoS CORNING
' ii`! VentSure>�7 Roof Ventilation
:'" TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND APPLICATION
VentSuW' 4-Foot Strip 1-114" x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon -
Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for
Vents: installation in shingle roof systems.
go 1 48"
14-718"
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12 to maximum 16112
Installation Height: Maximum 60-ft
Attachment Method: Cut a 2-inch opening (11-inchon each side of the (dge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 6-inches from the rake
edges. Apply a l-inch wide bead of ASTM D 4586 roofing cement along the entire
length of the outside edges of the vent to seal the vent to the field shingles, taking
care to not completely cover the weep slots in the vent. Center the vent over the
opening and fasten to the deck using the 11 ga. 2%.-inch galvanized ring shank nails
(shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be
installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each
vent piece.
Prepare the adjacent vent section by applying the roofing cement along the edges,
snap together with fixed vent, and fasten to the deck in the same manner as the first
section. Fasten the ridge shingles over the vent to the deck on the marked "shingle
nail line" with two (2) minimum 11 ga 2%-inch galvanized ring shank roofing nails
(shall comply with FBC Section 1506.5) provided with the vent or as directed by the
shingle manufacturer's installation instructions.
Allowable Roof Coverings: Asphalt shingles
QCR14003.4 FL10758-R8 Paae 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
C R E E K QWEo f CORNING
G VentSure�l Roof Ventilation
TECHNICAL SERVICES, LLC
VentSure Low Profile 18" x 24" x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM
Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with
with Exterior Louver: FBC Section 1507.4.3.
�............. -�
® I
r
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 3:12
Installation Height: Maximum 33-ft
Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from
the ridge. Apply 114-inch thick by 3-inch wide bed of ASTM ❑ 4586 roofing cement
around inner and outer flange. Place vent directly over the hole, ensuring the vent
sits flat on the roof- Fasten vent 4-inches o.c. and 1-inch from outside edge of flange
with minimum 12 ga. ring shank roofing nails (shall comply with FBG Section
1506.5), ensuring are -inch penetration through wood deck (Minimum 18 nails per
vent).
Install baffle in 1 -inch bed of ASTM D 4586 roofing cement and secure with
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5)
spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through
wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement.
Allowable Roof Coverings: Asphalt shingles
QCR14003.4 FL10758-RB Page 3 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply wananty, installation, recommended use, or other product attributes that are not
c ner9Z-1hr.A A.00 4 ]ha !—
:ii'' CREEK OWoof CORNING
G VentSure® Roof Ventilation
TECHNICAL SERVICES? i-LC
VentSure' Rigid Roll 5/8' x 11-114" x 20' attic ridge vent composed of high density polypropylene with a
Ridge Vent: spun -bond polypropylene fabric.
Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing
construction. Roof deck shall be designed and installed in accordance with FBC
requirements.
Roof slope: Minimum 2:12 to maximum 20:12
Installation Height: Maximum 50-ft
Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the
ridge for ventilation. The slot shall terminate approximately 12-inches from the rake
edges. Apply a continuous bead of polyurethane adhesive sealant along the entire
Length of the outside edges of the vent to seal the vent to the field shingles. Center
the vent over the opening and fasten the vent 24-inches o.c. to the deck using
minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5),
ensuring '/s inch penetration through wood deck.
Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line"
with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section
1506.5) or as directed by the shingle manufacturer's installation instructions,
ensuring %-inch penetration through wood deck. Outside edges of the shingles shall
be sealed with flashing cement.
Allowable Roof Coverings: Asphalt shingles
LIMITATIONS
1) This report is not for use in the HVHZ.
2) Fire Classification is outside the scope of this evaluation.
3) The roof deck and deck attachment shall be designed by others in accordance with the FBC.
4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the
manufacturer's published installation instructions. In the event of conflict, the more restrictive installation
shall be enforced.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion prior to installation.
6) Installation of the roof assembly is outside the scope of this evaluation.
7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential
construction applications.
8) Ali products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
OCR14003.4 FL10758-R8 Pape 4 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product Changes or quality assurance Changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are riot
13.5! C ��{ OWENS CORNING
1 1 Veni Roof Ventilation
ll' TECHNICAL. SERVICES, L-LC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E have demonstrated compliance with the Florida Building
Cade, 7tr Editian (2020) as evidenced in the referenced documents submitted by the named manufacturer.
llft1tI111►If
� r
No 74021
:* ►
•' STATE OF
Ir111lilt"
CERTIFICATION OF INDEPENDENCE
2020.12.15
1 3:59:34
05'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No- ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a fnanciai interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire. a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
0CR14003.9 FL10759-RS Page 5 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are rot