Loading...
HomeMy WebLinkAboutPA FL10758-R8, F , usiness s Professional Regulation 8CiS Home i � Log in user Registration Hat Topics ; Submit Surcharge stars & Facts Publications contact Vs 6CIS Site Map Links Search b �� Product Approval pr ' USER! public User Product Annroval Menu > Pmdurt or Amlication Search > Aoolication List > Annlication Detail FL # FL10758-RS ..... .... ....... ....... ......i Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 9reg. keel er@owenscernIn9.corn Greg Keeler g reg . kee le r@awe ns tarn i ng . tom Greg Keeler 2790 Columbus Road Granville, OH 4302-3 (740) 321-634S greg.keeter@owenscorning.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Prafessianal Engineer Evaluation Report - Hardcopy Received Zachary R. Priest PE-74021 PRI Construction Materials Technologies, LLC 12/31/2024 Steven M. Urich, PE ,, Validation Checklist - Hardcopy Received FL10758 R8 I_OCR14003.4 2020 FRC EVAI Vents find[^odf https!//www.floridabuilding.ors/pr/pr_app_dti.aspx?pararn=wGEVXQwt0gvidAvite0Y012bc3zFirydg9fPiig LAC VmFHfXgo03A5JQ%3d%3d Page 1 of 3 Certified By Sections frorn the Code 17D8.2 Product Approval Method Method 2 Option B Date Submitted 09/10/2020 Date Validated 12/16/2020 Date Pending FBC Approval 09/18/2020 Date Approved 12/17/2020 Summary of Products FL* Model, Number or Flame Description 10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation Moisture Ridge Vents in shingle roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1075$ R8 It OCR14003.4 ZD20 FBC Eva] Vents final .odf Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest 74021 Impact Resistant: N/A Created by independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation report FL1 758 R8 AE R140 3.4 202n FB Eval Vents final �df Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent Roof Vent With Exterior Louver I Limits of Use Installation Instructions Approved for use in HVHZ: No L1E 075a_R8 II OCRI4003.4 2020 FBC. Eyal Vents final pdf Verified By: Zachary R. Priest 74021 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other! Refer to evaluation report. FL10758 R8 AE OCR14001.4FK-Eval Vents final .pdf Created by I ndepende nt Th i rd Party: Yes 1D758.3 VentSnre Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No L7 Q7—U_g8 II OCRI4003.4 2020 PSC LWi p,. final ,pdf Verified By: Zachary R. Priest 74021 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation report. FLI0758 R8 AE OCR14003,4 2o20 FBC Eval Vents final IPdf Created by Independent Third Party: Yes Sack fifaxt Contact Us ::.2601 Blair stone Road_ Tallahassee FL 32399 phone: l350-4&7-187.4 The State of Florida i5 an AA/EEO errlployer right 207-2013 State of Florida.:: Pri vacv Statement :: psi billty Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity instead, contact the office by Phone or by traditional mail Ir you have any questions, please contact 850.487.1395.-Pursuantto section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for offlclal oommunlcation with the licensee. However email addresses are public record. if you d❑ not wish to supply a personal address, please provlde the Department with an emall address which can be made available to the publlcTo determine if you are a licensee under Chapter 455, F.S_, please dick here . product A pprova l Accepts: M No ®- https:llwww.floridabuilding.org/pr/pr_app_dfl.aspx?pa ram=wGEVXQwtDgv1dAvlteOY0%2bC3zFtrydggfphgLACiVmFHfXgoD3ASJQ%3d%3d Page 2 of 3 Credit Card Safe htfps:J/wwwfloridabuilding.org/pr/pr app_dtl.aspx7param=nvGEVXQwtDgvIclAvlteCYO%2bC3zFtrydg9fPhgLACiVMFHfXgUD3ASJQ%3d%3d Page 3 of 3 CREEK Certificate of Authorization No. 29524 1752Q Edinburgh Dr °tI• Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7"i EDITION (2020) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020 1 Owens Corning Parkway Toledo, OH 43657 (800) 438-7435 www. owe n s corn i n p, co m Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES EaLty Report No. Standard Year Architecturai Testing, Inc (TST1558) 01-38360.04 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) 01-38860.05 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) C1774.01-109-18 TAS I OO(A) 1995 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2016 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2015 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) OCF-111-02-01 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2016 PRI Construction Materials Technologies (TST5878) OCF-112-02-01 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 10D(A) 1995 PRI Construction Materials Technologies {TST5878] QCF-223-02-01 TAS 1 DD(A) 1995 PRI Construction Materials Technologies (TST5878) 01-1I-007-02-01 TAS 100(A) 1995 QCR14003.4 _ FE_10758-R8 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not cneriFrral[ar arlriraccerl herein 3": CREEK QWEoS CORNING ' ii`! VentSure>�7 Roof Ventilation :'" TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND APPLICATION VentSuW' 4-Foot Strip 1-114" x 14-718" x 48" low -profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. go 1 48" 14-718" Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 to maximum 16112 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (11-inchon each side of the (dge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a l-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2%.-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga 2%-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Allowable Roof Coverings: Asphalt shingles QCR14003.4 FL10758-R8 Paae 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not C R E E K QWEo f CORNING G VentSure�l Roof Ventilation TECHNICAL SERVICES, LLC VentSure Low Profile 18" x 24" x 2-3116" (32" x 23" flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FBC Section 1507.4.3. �............. -� ® I r Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 114-inch thick by 3-inch wide bed of ASTM ❑ 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof- Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBG Section 1506.5), ensuring are -inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in 1 -inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles QCR14003.4 FL10758-RB Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply wananty, installation, recommended use, or other product attributes that are not c ner9Z-1hr.A A.00 4 ]ha !— :ii'' CREEK OWoof CORNING G VentSure® Roof Ventilation TECHNICAL SERVICES? i-LC VentSure' Rigid Roll 5/8' x 11-114" x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun -bond polypropylene fabric. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 50-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire Length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring '/s inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring %-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATIONS 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. 8) Ali products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR14003.4 FL10758-R8 Pape 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product Changes or quality assurance Changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are riot 13.5! C ��{ OWENS CORNING 1 1 Veni Roof Ventilation ll' TECHNICAL. SERVICES, L-LC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E have demonstrated compliance with the Florida Building Cade, 7tr Editian (2020) as evidenced in the referenced documents submitted by the named manufacturer. llft1tI111►If � r No 74021 :* ► •' STATE OF Ir111lilt" CERTIFICATION OF INDEPENDENCE 2020.12.15 1 3:59:34 05'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No- ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a fnanciai interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire. a financial interest in any other entity involved in the approval process of the product. END OF REPORT 0CR14003.9 FL10759-RS Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are rot