INSTALLATION & OPERATION
MANUAL
Read all the instructions before installing your solar heating system.
How does a solar heating system work?
1. Connect your existing pool pump to the solar panel. Your pool pump
sends cold water to the solar panel.
2. The sun heats the water in the solar panel.
3. Warm water is then returned to your swimming pool.
How well does solariheating work?
A solar heating system if sized and installed properly will raise your pool water
temperature up to 100 F / 60 C and extend your swimming season. In order to maximize
the heat, the solar panel must be exposed to sunlight as long as possible. On rainy
days and at night the solar panel must be turned off so your pool water doesn't cool.
You can purchase an optional diverter kit to accomplish this. On cloudy days, the solar
panel won't work as well. It is recommended to use a solar blanket or a Liquid Solar
Blanket. This will help maintain the heat generated by the solar panel in your pool.
Is a special pump required?
If your panel is on the ground beside your pool, you can use your existing pool pump as long as it is in good working
condition. A 1 HP pump will handle a panel placed up to 9 meters (30 ft) away from your pool and one story up.
Where can the solar'panel be placed?
The solar panel can be placed on the ground.
Avoid placing in high traffic areas, as it is not
recommended to walk on the solar panel. The solar
panel can also be mounted on a rack or a roof. When
mounted, the panel should preferably be facing south
and be inclined at a 300to 450 degree angle. Don't
face the oanel North, because it will not heat A
mounting kit (part#SQ-RMK5) is required for placing
the solar panel on a rack or roof.
How many panels do I need?
C
m 12 M-I
M
Above -Ground
Above -Ground
No. of Systems
In -Ground Pool
No. of Systems
Round Pool
Oval Pool
.
i
Up to 16'x .
Up to 20'x i
# of Panels is
the minimum recommended.
More panels
will give you more
heat, faster.
Part # »scr :«_
_,�
Part # m«HAm
ay Para ma%kn � my Part # Description
Optional parts (cont.)
_Add -on Kit (SQ-ADDON)
1 SQ-ADDON required per SQ-2220 system added
Qty Part # Description
1 SK-FTGJ Rubber hose 7.5"
2 SK-FTG-L Metal collar (Hose clamp)
Diverter Kit (SO-DK)
Used to turn your system ON & OFF
Oty
Part #
SKFTG-A
Description
Threaded 2 way valve
SK-FTG-B
Threaded nipple
11SK--FTG-E
SK-FTG-C
Threaded tee
SK-FTG-D
Threaded combination hose
ada ter
Roll of Teflon tape
Vaccum relief Kit (SO-VRK)
Facilitates drainage for winterizing roof mounted systems
Qty Part# Description
1 SK-VRV Vacuum Relief Valve
1 SK-FTG-M Reducer Adapter 1.5'to
System Kit (SO-SK)
Everything needed to connect 3 SQ-2220 systems
Includes add -on kits, vacuum relief kit, high wind kits & diverter kit
Qty
4
Part #
SK-FTG-K
Description
Rubber hose 3.75"
8
SK-FTG-L
Metal collar (Hose clamp)
1
SK-VRV
Vacuum Relief Valve
1
SK-FTG-M
Reducer Adapter 1.5'to 0.75"
2
SK-FTG-N
PVC Adapter
4
SK-RMK-ST-N32
Nylon strap 32"
4
SK-RMK-ST-V32
Vinyl strap 32"
8
SK-RMK-BASE
Mounting base
8
SK-RMK-CAP
Mounting Cap
1
VALVE-3WAY-S
3 Way Diverter Valve
1
SK-FTG-O
PVC Tee
INSTALLATION
Additional parts required
• Flexible pool hose or rigid PVC pipe. Length dependent on distance from pool pump to solar panels.
• Metal collars (Hose clamps) - Quantity dependant on installation.
• For rack or roof placement a mounting kit (part # SO-RMKS) is required
Tools required
• Flat head screwdriver.
• For rack or roof placement: a utility knife, a power drill and silicone sealant.
PANEL ASSEMBLY
1. Choose placement for your solar panel(s). Make sure that it will be in the sun for most of the day. The area should be
clear of sharp objects.
2. Take the panel out of the box, remove the strap from panel and let the panel sit in the sun for approximately 30
minutes so it will become flexible.
3. a) Installation: one system on ground.
Outlet
'v
P
d
�
eU
u7 as
W
arz U
C
O
.O
Fri
O'
U
Inlet
ti. �' i'��a..-s:F_ •* .z_Kvs:.-......:...�.� "-�T....e....."�._..5�3's'.:�:
Diagram Step 3a
• Apply Teflon tape to threads of all 4 caps (SK-FTG-F )
See Fig 3a-1
• Thread all 4 caps into the panels as per Diagram Step 3a.
Do not over tighten. See Fig 3a-2
• Put "O" rings (SK-FTG-I) on both combination adapters (SK-
FTG-D) See Fig 3a-3
• Thread both combination adapters into the panels as per
Diagram Step 3a. Do not over tighten. See Fig 3a-4
• Push the rubber hose (SK-FTG-J ) over the panel header as per
Diagram Step 3a. Slide a metal collar (SK-FTG-L) onto the
rubber hose. Place metal collar'/4' from edge and tighten collar
with screwdriver. See Fig 3a-5.
• Slide another metal collar onto the rubber hose. Connect the 2
panels together by pushing the rubber hose over the second
panel header. Tighten metal collar to secure assembly.
See Fig 3a-6
3 b) Installation: one system on rack or roof. (Horizontal only)
1 - Mounting kit (part # SQ-RMK5) is required
tab
U
O
.0 '
d
u r —►
a
o�
c4
0
m
C
U
A Minimum of 2 inch fall per 10 feet
Outlet A
a ':, g-.'�.c�-e .-�rc•- �a w tc a -:.T- �S`•'TFa..�..a-'i«'4Y!45'
Inlet
Diagram Step 3b
• Using a utility knife or a hand saw, cut rubber hose (SK-FTG-J) in half. Make sure
you cut it as straight as possible. See Fig 3b-1. You should now have two rubbers
3 3/4" long.
• Apply Teflon on two of the caps (SK-FTG-F). See Fig 3a-1.You only need 2 of the 4
caps for this type of installation.
• Thread the 2 caps into the panels as per Diagram Step 3b. Do not over tighten.
See Fig 3a-2
• Put "O" rings (SK-FTG-1) on both combination adapters (SK-FTG-D). See Fig 3a-3
• Thread both combination adapters into the panels as per Diagram Step 3b.
Do not over tighten. See Fig 3a-4
• Push the rubber hose you cut in half previously over the panel header as per Diagram
Step 3b. Slide a metal collar (SK-FTG-L) onto the rubber hose. Place metal collar'/4"
from edge and tighten collar with screwdriver. See Fig 3a-5. Repeat for other end of panel.
• Slide another metal collar onto the rubber hose. Connect the 2 panels together by pushing
the rubber hose over the second panel header. Tighten metal collar to secure assembly.
See Fig 3a-6. Repeat for other end of panel.
• Install mounting kits as per instructions included with them. Panels must be installed with a slight
slope (minimum 2 inch per 10 feet) toward the inlet. This will allow the panel to drain properly.
Note: The inlet must always be at the lower end of the panel and the outlet at the higher end of the panel.
3. c) Installation: two systems on ground.
Add -on kit (part # SQ-ADDON) is required.
Outlet
lu
ea
m
b
h
C
d
Y rn
03
Ci
U
.r�
U
U
~
O
s -
�•'
Diagram Step 3c
• Apply Teflon tape to threads of all the caps (SK-FTG-F ) See Fig 3a-1
• Thread all the caps into the panels as per Diagram Step 3c. Do not over tighten. See Fig 3a-2
• Put "O" rings (SK-FTG-I) on two combination adapters (SK-FTG-D) See Fig 3a-3. You will only need
2 combination adapters for this type of installation.
• Thread both combination adapters into the panels as per diagram Step 3c. Do not over tighten. See Fig 3a-4
• Push the rubber hose (SK-FTG-J) over the panel header as per diagram Step 3c. Slide a metal collar
(SK-FTG-L) onto the rubber hose. Place metal collar'/4" from edge and tighten collar with screwdriver.
See Fig 3a-5. Repeat for 2"d system.
• Slide another metal collar onto the rubber hose. Connect the 2 panels together by pushing the rubber hose
over the second,panel header. Tighten metal collar to secure assembly. See Fig 3a-6. Repeat for 2nd system.
• Install Add -on kit (SO-ADDON) between two sets of panels (sold separately)
Note: A maximum of 6 2ft panels (3 systems) maybe plumbed In series
3 d) Installation: two systems on rack or roof. (Horizontal only)
2 Mounting kit (part # SQ-RMK5) are required.
1 System kit (part # SQ-SK) is required.
A Minimum of 2 inch fall per 10 fee[
Outlet
O
d
d
M
17
t
ed
.�ll -c
o L
UO
w
N
d n
r�
�
a
W
L
Q)
W3
a
ic�'�-'....f....3�?'•.:�..T.^..�Qv'S`�rX-'�S'��€=:Q�'F'. 2£""...3.�
.i�j
s
F
a
py03
o L
U
U
O
Inlet
Diagram Step 3d
• Using a utility knife cut rubber hose (SK-FTG-J) from each system in half. Make
sure you cut them as straight as possible. See Fig 3b-1. You should now have
rubbers that are 3 3/4" long.
• Apply Teflon on one of the caps (SK-FTG-F). See Fig 3a-1.You only need 1 cap
for this type of installation.
• Thread the cap into the panels as per Diagram Step 3d. Do not over tighten.
See Fig 3a-2
• If you are using flexible piping to connect panels to your pump then Put "O" rings
(SK-FTG-1) on both combination adapters (SK-FTG-D) See Fig 3a-3. Thread both
combination adapters into the panels as per Diagram Step 3d. Do not over tighten.
See Fig 3a-4
OR
If you are using rigid piping to connect panels to your pump then apply Teflon on
both PVC adapters (SK-FTG-N). See Fig 3d-1. Thread both adapters into the
panels as per Diagram Step 3d. Do not over tighten. See Fig 3d-2.
3 d) (cont.)
• Apply Teflon on reducer adapter (SK-FTG-M) included in the system kit (SQ-SK) sold
separately. Thread reducer adapter into the panel as per diagram Step 3d.
Do not over tighten. See Fig 3d-3.
• Apply Teflon on vacuum relief valve (SK-VRV). Thread vacuum relief valve into
the reducer adapter. Do not over tighten. See Fig 3d-3.
Note: The vacuum valve assembly must be installed at the top of the panels as per diagram Step 3d.
• Push the rubber hose you cut in half previously over the panel header as per diagram Step 3d. Slide a metal
collar (SK-FTG-L) onto the rubber hose. Place metal collar 114" from edge and tighten collar with screwdriver.
See Fig 3a-5. Repeat for other end of panel.
• Slide another metal collar onto the rubber hose. Connect the 2 panels together by pushing the rubber hose
over the second panel header. Tighten metal collar to secure assembly. See Fig 3a-6. Repeat for other end of
panel.
• Repeat previous 2 steps for other system.
• You should now have two sets of connected panels. You need to use rubbers from the system
kit (SK-FTG-K) to connect the two set together as per Diagram Step3d.
• Install mounting kits as per instructions included with them. Panels must be installed with a slight
slope (minimum 2 inch per 10 feet) toward the inlet. This will allow the panel to drain properly.
Note: The inlet must always be at the lower end of the panel and the outlet at the higher end of the panel.
Note: A maximum of 12 2ft panels (6 systems) may be plumbed in parallel
For high wind areas you can install the Nylon straps and Vinyl straps from System Kit.
Mark a spot 6" to the right of the outlet. Mark spots 6" to the right of every second
rubber hose that are on the same side as the outlet. Mark a spot 6" to the right of the
cap. See Fig 3d-4. Place mounting base (SK-RMK-BASE) on these spots. Drill pilot
holes, apply silicone roof sealant and screw mounting base into roof. See Fig 3d-5.
Wrap a Nylon strap (SK-RMK-ST-N32) around the panel header (see Fig 3d-7) or
around rubber hose (see Fig 3d-6). Lay both ends of strap in the mounting base and
pull tight. See Fig 3d-8. Screw on mounting cap (SK-RMK-CAP). See Fig 3d-9.
Repeat process on the inlet side of the panels but using the Vinyl straps (SK-RMK-ST-V32)
instead.
CONNECTING TO POOL
System with no diverter
To Panel From Panel
Inlet Outlet
Filter
t�v
Pool Outlet Pool Inlet
Swimming Pool
Diagram 61
1. Turn off your pool pump. Block the inlet and outlet of your pool so that the water won't empty
when you are connecting your panel(s).
2. Remove the hose from the pool inlet ( hose between the filter and the pool ) and connect the
hose to the panel inlet. If hose is too short, you need to purchase a new one. Make sure
you purchase the appropriate size that is compatible with your existing pool equipment.
For 1114' hose, it will only slide over the small end of the combination adapter. See Fig C1-1.
For 11/2" hose, it will slide all the way to flange of combination adapter. See Fig C1-2. Place
metal collar'/4" from edge and tighten collar with screwdriver. See Diagram C-1.
3. Connect another hose (not supplied) from the panel outlet to the pool inlet. See Diagram C-1.
4. Make sure that your hoses are all connected the correct way and that all the collars have been
tightened. Unblock the inlet and outlet of your pool.
5. Turn on your pool pump. Check for any leaks. If any of the threaded fittings leak, remove the
fitting and apply more Teflon. If any of the hoses leak at the connection, loosen the collar and
push the hose over the fitting and re -tighten the metal collar. You will see air bubbles coming
from the pool inlet. This is normal and will stop once the air inside the panels has been purged.
Note: Without a diverter, your solar heating system is always ON. At night, your solar panels will cool your swimming pool.
We recommend you close your pump at night to avoid this or purchase a diverter kit (SO-DK)
System with diverter (part # SQ-DK)
Diagram 42
1. Turn off your pool pump. Block the inlet and outlet of your pool so that the water won't empty when you are
connecting your panel(s).
2. Remove the hose from the pool inlet ( hose between the filter and the pool ) Connect the hose to one side of the
diverter kit previously assembled as per instructions included with diverter kit. For 11/4' hose, it will only slide over the
small end of the combination adapter. See Fig C1-1. For 11/2" hose, it will slide all the way to flange of combination
adapter. See Fig C1-2. Place metal collar'/4' from edge and tighten collar with screwdriver. See Diagram C-2.
3. Take a hose (not supplied) long enough to reach the panel and connect one end to the diverter kit (same side of the
two way valve as in step 2) Place metal collar and tighten. Connect other end of the hose to the panel inlet. Place
metal collar and tighten. See Diagram C-2.
4. Take another hose (not supplied) and connect it to the panel outlet. Place metal collar and tighten. Connect other
end of the hose to the diverter kit. Place metal collar and tighten. See Diagram C-2.
5. Take the last hose (not supplied) and connect it to the last open end of the diverter kit. Place metal collar
and tighten. Connect the other end of the hose to your pool inlet. Place metal collar and tighten. See diagram C-2.
6. Make sure the valve on the diverter is on the open position.
Valve in the open position Valve in the closed position
Solar heating is OFF ( not heating) Solar heating Is ON ( heating )
7. Make sure that your hoses are all connected the correct way and that all the collars have been tightened.
Unblock the inlet and outlet of your pool.
8. Turn on your pool pump. Check for any leaks. If any of the threaded fittings leak, remove the fitting and apply more
Teflon. If any of the hoses leak at the connection, loosen the collar and push the hose over the fitting and re -tighten
the metal collar. You will see air bubbles coming from the pool inlet. This is normal, the air in the hoses is being
purged.
9. Turn your solar heating system on by turning the two-way valve in the diverter to the closed position. See Fig C2-2.
Once again you will see air bubbles coming from your pool. The system is now purging the air that is in the
solar panel(s).
11
System with system kit (part # SQ-SK)
To Panel From Panel
Inlet Outlet
Three Way PVC Tee
Valve
Filter
nmm
Pool Outlet Pool Inlet
Swimming Pool
Diagram C-3
1. Turn off your pool pump. Block the inlet and outlet of your pool so that the water won't empty when you are
connecting your panel(s).
2. Install Three Way Diverter Valve (VALVE-3WAY-S) and the PVC Tee (SK-FTG-O) on pool return line after filter. See
Diagram C-3. If you have another pool heater, the three-way valve and tee should be installed before it.
3. You may want to install a check valve between the three-way valve and your filter. This will prevent the water that is in
the panels from flowing backwards into the filter when your pump is turned off. If you install a check valve, make sure
when you winterize your pool that all your piping in drained.
4. Run you feed and return PVC piping from your pool to your solar panels. Make sure piping is installed in such a way
to allow proper drainage.
5. Make sure that your piping is connected the correct way and that all joints have been glued. Unblock the inlet and
outlet of your pool.
6. Turn on your pool pump. Check for any leaks. You will see air bubbles coming from the pool inlet. This is normal, the
air in the hoses is being purged.
7. Turn your solar heating system on by turning the three way diverter valve. Once again you will see air bubbles coming
from your pool. The system is now purging the air that is in the solar panel(s).
Note: A motorized valve and Automatic controls are optional items available from your local pool dealer
12